Search NASA⌕ Search

SEARCH · Search NASA

Results for “Systematics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Systematic uncertainties from halo asphericity in dark matter searches

Although commonly assumed to be spherical, dark matter halos are predicted to be non-spherical by N-body simulations and their asphericity has a potential impact on the systematic uncertainties in dark matter searches. The evaluation of these uncertainties is the main aim of this work, where we study the impact of aspherical dark matter density distributions in Milky-Way-like halos on direct and indirect searches. Using data from the large N-body cosmological simulation Bolshoi, we perform a statistical analysis and quantify the systematic uncertainties on the determination of local dark matter density and the so-called J factors for dark matter annihilations and decays from the galactic center. We find that, due to our ignorance about the extent of the non-sphericity of the Milky Way dark matter halo, systematic uncertainties can be as large as 35%, within the 95% most probable region, for a spherically averaged value for the local density of 0.3-0.4 GeV/cm {sup 3}. Similarly, systematic uncertainties on the J factors evaluated around the galactic center can be as large as 10% and 15%, within the 95% most probable region, for dark matter annihilations and decays, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring cosmic origins with CORE: Mitigation of systematic effects

Here, we present an analysis of the main systematic effects that could impact the measurement of CMB polarization with the proposed CORE space mission. We employ timeline-to-map simulations to verify that the CORE instrumental set-up and scanning strategy allow us to measure sky polarization to a level of accuracy adequate to the mission science goals. We also show how the CORE observations can be processed to mitigate the level of contamination by potentially worrying systematics, including intensity-to-polarization leakage due to bandpass mismatch, asymmetric main beams, pointing errors and correlated noise. We use analysis techniques that are well validated on data from current missions such as Planck to demonstrate how the residual contamination of the measurements by these effects can be brought to a level low enough not to hamper the scientific capability of the mission, nor significantly increase the overall error budget. We also present a prototype of the CORE photometric calibration pipeline, based on that used for Planck, and discuss its robustness to systematics, showing how CORE can achieve its calibration requirements. While a fine-grained assessment of the impact of systematics requires a level of knowledge of the system that can only be achieved in a future study phase, the analysis presented here strongly suggests that the main areas of concern for the CORE mission can be addressed using existing knowledge, techniques and algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

Exploring HOD-dependent systematics for the DESI 2024 Full-Shape galaxy clustering analysis

We analyze the robustness of the DESI 2024 cosmological inference from the full shape of the galaxy power spectrum to uncertainties in the Halo Occupation Distribution (HOD) model of the galaxy-halo connection and the choice of priors on nuisance parameters. We assess variations in the recovered cosmological parameters across a range of mocks populated with different HOD models and find that shifts are often greater than 20% of the expected statistical uncertainties from the DESI data. We encapsulate the effect of such shifts in terms of a systematic covariance term, C HOD , and an additional diagonal contribution quantifying the impact of our choice of nuisance parameter priors on the ability of the effective field theory (EFT) model to correctly recover the cosmological parameters of the simulations. These two covariance contributions are designed to be added to the usual covariance term, C stat , describing the statistical uncertainty in the power spectrum measurement, in order to fairly represent these sources of systematic uncertainty. This novel approach should be more general and robust to the choice of model or additional external datasets used in cosmological fits than the alternative approach of adding systematic uncertainties to the recovered marginalised parameter posteriors. We compare the approaches within the context of a fixed ΛCDM model and demonstrate that our method gives conservative estimates of the systematic uncertainty that nevertheless have little impact on the final posteriors obtained from DESI data.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular systematics-free cosmological analysis of galaxy clustering in configuration space

ABSTRACT Galaxy redshift surveys are subject to incompleteness and inhomogeneous sampling due to the various constraints inherent to spectroscopic observations. This can introduce systematic errors on the summary statistics of interest, which need to be mitigated in cosmological analysis to achieve high accuracy. Standard practices involve applying weighting schemes based on completeness estimates across the survey footprint, possibly supplemented with additional weighting schemes accounting for density-dependent effects. In this work, we concentrate on pure angular systematics and describe an alternative approach consisting in analysing the galaxy two-point correlation function where angular modes are nulled. By construction, this procedure removes all possible known and unknown sources of angular observational systematics, but also part of the cosmological signal. We use a modified Landy–Szalay estimator for the two-point correlation function that relies on an additional random catalogue where angular positions are randomly drawn from the galaxy catalogue, and provide an analytical model to describe this modified statistic. We test the model by performing an analysis of the full anisotropic clustering in mock catalogues of luminous red and emission-line galaxies at 0.43 < z < 1.1. We find that the model fully accounts for the modified correlation function in redshift space, without introducing new nuisance parameters. The derived cosmological parameters from the analysis of baryon acoustic oscillations and redshift-space distortions display slightly larger statistical uncertainties, mostly for the growth rate of structure parameter fσ8 that exhibits a $50{{\ \rm per\ cent}}$ statistical error increase, but free from angular systematic error.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-550: Range Effects in Proton Therapy Caused by Systematic Errors in the Stoichiometric Calibration

Purpose: The procedure for proton treatment planning involves the conversion of the patient's X-ray CT from Hounsfield units into relative stopping powers (RSP), using a stoichiometric calibration curve (Schneider 1996). In clinical practice a 3.5% margin is added to account for the range uncertainty introduced by this process and other errors. RSPs for real tissues are calculated using composition data and the Bethe-Bloch formula (ICRU 1993). The purpose of this work is to investigate the impact that systematic errors in the stoichiometric calibration have on the proton range. Methods: Seven tissue inserts of the Gammex 467 phantom were imaged using our CT scanner. Their known chemical compositions (Watanabe 1999) were then used to calculate the theoretical RSPs, using the same formula as would be used for human tissues in the stoichiometric procedure. The actual RSPs of these inserts were measured using a Bragg peak shift measurement in the proton beam at our institution. Results: The theoretical calculation of the RSP was lower than the measured RSP values, by a mean/max error of - 1.5/-3.6%. For all seven inserts the theoretical approach underestimated the RSP, with errors variable across the range of Hounsfield units. Systematic errors for lung (average of two inserts), adipose and cortical bone were - 3.0/-2.1/-0.5%, respectively. Conclusion: There is a systematic underestimation caused by the theoretical calculation of RSP; a crucial step in the stoichiometric calibration procedure. As such, we propose that proton calibration curves should be based on measured RSPs. Investigations will be made to see if the same systematic errors exist for biological tissues. The impact of these differences on the range of proton beams, for phantoms and patient scenarios, will be investigated. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-03: Determination of Plan Robustness for Systematic Setup Errors Using Trilinear Interpolation

Purpose: Treatment plan evaluations in radiotherapy are currently ignoring the dosimetric impact of setup uncertainties. The determination of the robustness for systematic errors is rather computational intensive. This work investigates interpolation schemes to quantify the robustness of treatment plans for systematic errors in terms of efficiency and accuracy. Methods: The impact of systematic errors on dose distributions for patient treatment plans is determined by using the Swiss Monte Carlo Plan (SMCP). Errors in all translational directions are considered, ranging from −3 to +3 mm in mm steps. For each systematic error a full MC dose calculation is performed leading to 343 dose calculations, used as benchmarks. The interpolation uses only a subset of the 343 calculations, namely 9, 15 or 27, and determines all dose distributions by trilinear interpolation. This procedure is applied for a prostate and a head and neck case using Volumetric Modulated Arc Therapy with 2 arcs. The relative differences of the dose volume histograms (DVHs) of the target and the organs at risks are compared. Finally, the interpolation schemes are used to compare robustness of 4- versus 2-arcs in the head and neck treatment plan. Results: Relative local differences of the DVHs increase for decreasing number of dose calculations used in the interpolation. The mean deviations are <1%, 3.5% and 6.5% for a subset of 27, 15 and 9 used dose calculations, respectively. Thereby the dose computation times are reduced by factors of 13, 25 and 43, respectively. The comparison of the 4- versus 2-arcs plan shows a decrease in robustness; however, this is outweighed by the dosimetric improvements. Conclusion: The results of this study suggest that the use of trilinear interpolation to determine the robustness of treatment plans can remarkably reduce the number of dose calculations. This work was supported by Varian Medical Systems. This work was supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Marginalizing instrument systematics in HST WFC3 transit light curves

Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) infrared observations at 1.1–1.7 μm probe primarily the H{sub 2}O absorption band at 1.4 μm, and have provided low-resolution transmission spectra for a wide range of exoplanets. We present the application of marginalization based on Gibson to analyze exoplanet transit light curves obtained from HST WFC3 to better determine important transit parameters such as R{sub p}/R{sub *}, which are important for accurate detections of H{sub 2}O. We approximate the evidence, often referred to as the marginal likelihood, for a grid of systematic models using the Akaike Information Criterion. We then calculate the evidence-based weight assigned to each systematic model and use the information from all tested models to calculate the final marginalized transit parameters for both the band-integrated and spectroscopic light curves to construct the transmission spectrum. We find that a majority of the highest weight models contain a correction for a linear trend in time as well as corrections related to HST orbital phase. We additionally test the dependence on the shift in spectral wavelength position over the course of the observations and find that spectroscopic wavelength shifts δ{sub λ}(λ) best describe the associated systematic in the spectroscopic light curves for most targets while fast scan rate observations of bright targets require an additional level of processing to produce a robust transmission spectrum. The use of marginalization allows for transparent interpretation and understanding of the instrument and the impact of each systematic evaluated statistically for each data set, expanding the ability to make true and comprehensive comparisons between exoplanet atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Uncertainties in the NOvA \nu_\mu-Disappearance Analysis

As the NOvA long-baseline neutrino oscillation experiment takes more data, systematic uncertainty begins to more heavily impact the oscillation analyses. The largest effects are calibration on calorimetric energy, detector modeling on muon energy scale, and near-detector pileup on normalization of the far-detector expectation. Cross-section systematics will be discussed in another poster. Detailed studies have justified previous systematics as too conservative and suggested smaller values. Focused study of detector modeling using dE/dx and external measurements constrain the calibration and energy scale uncertainties. A novel technique is used to assess the impact of activity from neutrino activity piling up over signal, where a simulated neutrino is overlaid into both data and simulation. The difference in efficiency of selecting that single neutrino among data and simulated spills then dominates the normalization systematic.

Alion, Tyler [Sussex U.]↗

Revisiting Grodzins systematics of B(E2) values

Using Grodzins formalism, we analyze systematics of our latest evaluated B(E2) data for all the even–even nuclei in Z=2–104. The analysis indicates a low predictive power of systematics for a large number of cases, and a strong correlation between B(E2) fit values and nuclear structure effects. These findings provide a strong rationale for introduction of individual or elemental (grouped by Z) fit parameters. The current estimates of quadrupole collectivities for systematics of even–even nuclei yield complementary values for comparison with experimental results and theoretical calculations. Furthermore, the lists of fit parameters and predicted B(E2) values are given and possible implications are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematic quark/gluon identification with ratios of likelihoods

Discriminating between quark- and gluon-initiated jets has long been a central focus of jet substructure, leading to the introduction of numerous observables and calculations to high perturbative accuracy. At the same time, there have been many attempts to fully exploit the jet radiation pattern using tools from statistics and machine learning. We propose a new approach that combines a deep analytic understanding of jet substructure with the optimality promised by machine learning and statistics. After specifying an approximation to the full emission phase space, we show how to construct the optimal observable for a given classification task. This procedure is demonstrated for the case of quark and gluons jets, where we show how to systematically capture sub-eikonal corrections in the splitting functions, and prove that linear combinations of weighted multiplicity is the optimal observable. In addition to providing a new and powerful framework for systematically improving jet substructure observables, we demonstrate the performance of several quark versus gluon jet tagging observables in parton-level Monte Carlo simulations, and find that they perform at or near the level of a deep neural network classifier. Combined with the rapid recent progress in the development of higher order parton showers, we believe that our approach provides a basis for systematically exploiting subleading effects in jet substructure analyses at the Large Hadron Collider (LHC) and beyond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cadmium isotope systematics in sedimentary carbonate: Extending the utility of the cadmium isotope palaeo-productivity proxy

The cadmium (Cd) isotope compositions of seven Holocene (<11.7 ka) carbonate sediments, including the bulk carbonate, as well as the > 140 μm (zooplankton), <63 μm and < 20 μm (phytoplankton) fractions, and individual species of foraminifera isolated from the bulk carbonate were obtained for sub-samples processed using the Cd-cleaning and Mg/Ca cleaning methods. The respective Cd isotope systematics of each carbonate archive were then compared with the Cd isotope signature within the ocean using modern seawater data. We show that a constant Cd isotope fractionation factor of -0.25 ± 0.03 ‰ (2SE, n = 4) describes the partitioning of Cd from seawater into the carbonate phase ($Δ^{114}Cd_{CdC O_3 - seawater}$), allowing for accurate reconstructions of the past seawater nutrient regime. The Cd isotope signature of the < 63 µm and < 20 µm (phytoplankton) fractions can display comparable values to those recorded in the modern surface ocean, and can be used to model the magnitude of Cd uptake and utilisation in the past ocean. Individual species of planktic and benthic foraminifera, which inhabit different depths of the water column, can provide a full surface to deep water column reconstruction of the Cd nutrient regime, while infaunal benthic foraminifera can be used to interrogate the Cd isotope systematics of sediment porewaters. Bulk sediment and the > 140 µm (zooplankton) fraction also retain important information relating to the overlying water column Cd isotope systematics and can serve as essential archives for palaeo-productivity reconstructions where the separation of individual components from the bulk sediment is not possible. This new Cd isotope palaeo-productivity toolkit can considerably aid reconstruction efforts and vastly improves the ability to quantify the role of phytoplankton in modulating carbon sequestration through transitions in Earth’s climate evolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Curative Treatment of Stage I Non-Small-Cell Lung Cancer in Patients With Severe COPD: Stereotactic Radiotherapy Outcomes and Systematic Review

Objectives: Patients with severe chronic obstructive pulmonary disease (COPD) have a high risk of lung cancer and of postsurgical complications. We studied outcomes after stereotactic body radiotherapy (SBRT) in patients with severe COPD, as defined by Global Initiative for Chronic Obstructive Lung Disease (GOLD) criteria, and performed a systematic review of the literature on outcomes after SBRT or surgery in these patients. Methods: A single-institution cohort of 176 patients with COPD GOLD III-IV and Stage I non-small-cell lung cancer (NSCLC) treated with SBRT was evaluated. A systematic review identified studies reporting outcomes after SBRT or surgery for Stage I NSCLC in patients with GOLD III-IV or a predicted postoperative forced expiratory volume in 1 second (FEV1) of {<=}40%. Results: In the single-institution cohort, median follow-up was 21 months and median overall survival (OS) was 32 months. Actuarial 3-year local control was 89%, and 1- and 3-year OS were 79% and 47%, respectively. COPD severity correlated with OS (p = 0.01). The systematic review identified four other studies (two surgical, two SBRT, n = 196 patients). SBRT studies were published more recently and included older patients than surgical studies. Mean 30-day mortality was 0% post-SBRT and 10% after surgery. Local or locoregional control was high ({>=}89%) after both treatments. Post-SBRT, actuarial OS was 79-95% at 1 year and 43-70% at 3 years. Postsurgical actuarial OS was 45-86% at 1 year and 31-66% at 3 years. Conclusions: SBRT and surgery differ in risk of 30-day mortality in patients with severe COPD. Despite the negative selection of SBRT patients, survival at 1 and 3 years is comparable between the two treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Charged Particle Radiation Therapy for Uveal Melanoma: A Systematic Review and Meta-Analysis

Charged particle therapy (CPT) delivered with either protons, helium ions, or carbon ions, has been used to treat uveal melanoma. The present analysis was performed to systematically evaluate the efficacy and adverse effects of CPT for uveal melanoma. We searched EMBASE, MEDLINE, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and SciVerse Scopus and cross-referenced recent systematic reviews through January 2012. Two independent reviewers identified clinical trials and observational studies of CPT (protons, helium ions, and carbon ions). These reviewers extracted data and assessed study quality. Twenty-seven studies enrolling 8809 uveal melanoma patients met inclusion criteria. The rate of local recurrence was significantly less with CPT than with brachytherapy (odds ratio [OR] = 0.22, 95% confidence interval [CI], 0.21-0.23). There were no significant differences in mortality or enucleation rates. Results were robust in multiple sensitivity analyses. CPT was also associated with lower retinopathy and cataract formation rates. Data suggest better outcomes may be possible with charged particle therapy with respect to local recurrence, retinopathy, and cataract formation rates. The overall quality of the evidence is low, and higher quality comparative effectiveness studies are needed to provide better evidence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevalence of Listeria monocytogenes , Salmonella spp., Shiga toxin-producing Escherichia coli , and Campylobacter spp. in raw milk in the United States between 2000 and 2019: A systematic review and meta-analysis

Raw (unpasteurized) milk is available for sale and direct human consumption within some states in the United States (US); it cannot be sold or distributed in interstate commerce. Raw milk may contain pathogenic microorganisms that, when consumed, may cause illness and sometimes may result in death. No comprehensive review for prevalence and levels of the major bacterial pathogens in raw milk in the US exists. The objective of the present research was to systematically review the scientific literature published from 2000 to 2019 to estimate the prevalence and levels of Listeria monocytogenes, Salmonella spp., Shiga toxin-producing Escherichia coli (STEC), and Campylobacter spp. in raw milk in the US. Peer-reviewed studies were retrieved systematically from PubMed®, Embase®, and Web of ScienceTM. The unique complete nonduplicate references were uploaded into the Health Assessment Work Collaborative (HAWC). Based on the selection criteria, twenty studies were included in the systematic review and meta-analysis. Comprehensive Meta-Analysis (CMA) was used for statistical analyses, specifically, random effects meta-analyses were used to synthesize raw bulk tank milk (BTM) and milk filters (MF) data. Data from studies using culture and non–culture-based detection methods were included. Forest plots generated in CMA (Biostat, Englewood, NJ) were used to visualize the results. The average prevalence (event rate) of L. monocytogenes, Salmonella spp., STEC, and Campylobacter spp. in raw BTM in the US was estimated at 4.3% (95% confidence intervals [CIs], 2.8–6.5%), 3.6% (95% CIs, 2.0–6.2%), 4.3% (95% CIs, 2.4–7.4%), and 6.0% (95% CIs, 3.2–10.9%), respectively. Estimated prevalence was generally larger in MF than in BTM. There was not enough data to perform a meta-analysis for the prevalence or levels of pathogens in raw milk from retail establishments or other milk categories.

60 APPLIED LIFE SCIENCES↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of MCNP ® 6 implicit-capture simulations for quantification of systematic uncertainties from experimental environments

In this study, the high statistical precision that can be achieved using modern data collection techniques implies that systematic uncertainties that were ignored or not considered for past experiments must now be explored. The folding of Monte Carlo simulations into experimental data analysis, which is becoming common practice, requires an estimate of the systematic uncertainty present in the experimental result from uncertainties in the library of cross sections used during the simulation, but this source of uncertainty is typically not quantified. Here we describe a method to estimate this systematic uncertainty by varying the cross sections used during simulation runtime. As opposed carrying out hundreds of sequential analog Monte Carlo simulations, this task was accomplished through a post-processing calculation of output from a single simulation that was run using the implicit-capture formalism available with MCNP ® 6.2 and the PTRAC output format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic characterization of human gut microbiome-secreted molecules by integrated multi-omics

The human gut microbiome produces a complex mixture of biomolecules that interact with human physiology and play essential roles in health and disease. Crosstalk between micro-organisms and host cells is enabled by different direct contacts, but also by the export of molecules through secretion systems and extracellular vesicles. The resulting molecular network, comprised of various biomolecular moieties, has so far eluded systematic study. Here we present a methodological framework, optimized for the extraction of the microbiome-derived, extracellular biomolecular complement, including nucleic acids, (poly)peptides, and metabolites, from flash-frozen stool samples of healthy human individuals. Our method allows simultaneous isolation of individual biomolecular fractions from the same original stool sample, followed by specialized omic analyses. The resulting multi-omics data enable coherent data integration for the systematic characterization of this molecular complex. Our results demonstrate the distinctiveness of the different extracellular biomolecular fractions, both in terms of their taxonomic and functional composition. This highlights the challenge of inferring the extracellular biomolecular complement of the gut microbiome based on single-omic data. The developed methodological framework provides the foundation for systematically investigating mechanistic links between microbiome-secreted molecules, including those that are typically vesicle-associated, and their impact on host physiology in health and disease.

59 BASIC BIOLOGICAL SCIENCES↗

Planck 2013 results. III. LFI systematic uncertainties

We present the current estimate of instrumental and systematic effect uncertainties for the Planck -Low Frequency Instrument relevant to the first release of the Planck cosmological results. Here, we give an overview of the main effects and of the tools and methods applied to assess residuals in maps and power spectra. We also present an overall budget of known systematic effect uncertainties, which are dominated by sidelobe straylight pick-up and imperfect calibration. However, even these two effects are at least two orders of magnitude weaker than the cosmic microwave background fluctuations as measured in terms of the angular temperature power spectrum. A residual signal above the noise level is present in the multipole range &ell; < 20, most notably at 30 GHz, and is probably caused by residual Galactic straylight contamination. Current analysis aims to further reduce the level of spurious signals in the data and to improve the systematic effects modelling, in particular with respect to straylight and calibration uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗