Pressure Build-Up During the Fire Test in Type B(U) Packages Containing Water - 13280

The safety assessment of packages for the transport of radioactive materials with content containing liquids requires special consideration. The main focus is on water as supplementary liquid content in Type B(U) packages. A typical content of a Type B(U) package is ion exchange resin, waste of a nuclear power plant, which is not dried, normally only drained. Besides the saturated ion exchange resin, a small amount of free water can be included in these contents. Compared to the safety assessment of packages with dry content, attention must be paid to some more specific issues. An overview of these issues is provided. The physical and chemical compatibility of the content itself and the content compatibility with the packages materials must be demonstrated for the assessment. Regarding the mechanical resistance the package has to withstand the forces resulting from the freezing liquid. The most interesting point, however, is the pressure build-up inside the package due to vaporization. This could for example be caused by radiolysis of the liquid and must be taken into account for the storage period. If the package is stressed by the total inner pressure, this pressure leads to mechanical loads to the package body, the lid and the lid bolts. Thus, the pressure is the driving force on the gasket system regarding the activity release and a possible loss of tightness. The total pressure in any calculation is the sum of partial pressures of different gases which can be caused by different effects. The pressure build-up inside the package caused by the regulatory thermal test (30 min at 800 deg. C), as part of the cumulative test scenario under accident conditions of transport is discussed primarily. To determine the pressure, the temperature distribution in the content must be calculated for the whole period from beginning of the thermal test until cooling-down. In this case, while calculating the temperature distribution, conduction and radiation as well as evaporation and condensation during the associated process of transport have to be considered. This paper discusses limiting amounts of water inside the cask which could lead to unacceptable pressure and takes into account saturated steam as well as overheated steam. However, the difficulties of assessing casks containing wet content will be discussed. From the authority assessment point of view, drying of the content could be an effective way to avoid the above described pressure build-up and the associated difficulties for the safety assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fire Chemistry Testing of Spray-On Foam Insulation (SOFI)

An experimental study was initiated that included the long-term testing of the following SOFI materials, which make up the majority of the Thermal Protection System of the Shuttle External Tank: NCFI 24-124 (acreage foam) and BX-265 (close-out foam, including the intertank flange and bipod areas). A potential alternate material, NCFI 27-68 (acreage foam with flame retardant removed), was also tested. Fire chemistry testing was completed on samples that were retrieved after aging/weathering at intervals of 3, 6, and 12 months. The testing included three standard test methods: limiting oxygen index (ASTM G125), radiant panel (ASTM E162), and cone calorimeter (ASTM E1354).

Source record↗

Development of Lead Free Energy Absorber for Space Shuttle Blast Container

The Space Shuttle vehicle (SSV) is connected to the mobile launch platform (MLP) by four aft skirt hold down studs on each solid rocket booster (SRB). Prior to lift-off, the frangible nuts inside the aft skirt blast containers (BC) are severed into two nut halves by two pyrotechnic booster cartridges. This action releases the SSV and allows the hold down studs to eject through the aft skirt bore and then down into the MLP. USBI has been tasked to upgrade the BC for two specific reasons; 1. to eliminate lead for environmental concerns, and 2. to reduce the chance of nut recontact with the holddown stud. Nut recontact with the stud has been identified as a likely contributor to stud hangups. This upgrade will replace the lead liner with an aluminum foam material. The aluminum foam used as a energy absorber is a proven design in many other aerospace/defense applications. Additional benefits of using the open cell, energy absorbent aluminum foam in place of the solid lead liner are: A. Lead handling/ exposure, and possible contamination, along with hazardous waste disposal will be eliminated; B. Approximately 200 lbs. weight savings will be contributed to each Space Shuttle flight by using aluminum foam over lead; C. The new aluminum liner is designed to catch all shrapnel from frangible nuts thus virtually eliminating chance of foreign object debris (FOD) exiting the HDP, and causing potential damage to the vehicle; D. Potential of using the lighter aluminum liner over lead, allows for easier assembly and disassembly of blast container elements, also allowing for improvements in safety, operator handling, and efficiency of operations. Six BC firing tests will be required to determine if the new liner material will perform in a way to decrease the chance of stud hangups and enhance the ability of the BC to retain blast debris. Testing will be performed at the Kennedy Space Center (KSC) facility known as the Launch Equipment Test Facility (LETF), and will simulate the SRB hold- down post, with actual BC hardware and pyrotechnics assembled, and then test fired. Initial testing was performed in 1997 using a frangible nut in a static drop test over lead and aluminum foam sheet materials. The aluminum foam showed a dramatic improvement of energy absorption over the lead liner material. Proof-of-Principle testing at the KSC-LETF commenced in May, 1998, and is expected to be completed by June, 1998.

Ingram, T.↗

High-temperature oxidation and erosion-resistant refractory coatings

Various refractory coating systems were evaluated for rocket nozzle applications by actual rocket test firings. A reference is noted which identifies failure mechanisms and gives results of the firing tests for 18 coating systems. Iridium, iridium-rhenium, and hafnium oxide-zirconium oxide coatings show most promising results.

Peterson, D. A.↗

Timing system for firing widely spaced test nuclear detonations

The national weapons design laboratories (Los Alamos National Laboratory and Lawrence Livermore National Laboratory) test fire nuclear devices at the Nevada Test Site (NTS), which is spread over an area of over 1200 square miles (a bit larger than the state of Rhode island). On each test there are hundreds of high time resolution recordings made of nuclear output waveforms and other phenomena. In order to synchronize these recordings with each other, with the nuclear device, and with offsite recordings, there is a requirement that the permanent command center and the outlying temporary firing sites be time tied to each other and to UTC to permit firing the shot at a predetermined time with an accuracy of about a microsecond. The system is so designed that this can reduce to about 100 nanoseconds if it should prove necessary in the future.

Ralph E. Partridge↗

STABILITY TESTS OF MONOPROPELLANTS EXPOSED TO FLAMES AND RIFLE FIRE

Tests of the stability of several monopropellants under the effects of impact and heat were conducted in order to assess the potential hazard in a propellant storage area from major fires and enemy attack. Hydrazine, hydrazine nitrate solution, n-propyl nitrate, and ethylene oxide were all tested in one-gallon aluminum containers (half of them filled to 25% and half to 95% capacity) by being subjected to oil bonfires and wood bonfires, and 20-mm incendiary, 20mm high explosive incendiary, and .30-caliber rifle fire. Aviation gasoline was tested in the same manner, for comparison. In the bonfire tests, all four monopropellants generally gave explosion intensities equivalent to one another regardless of the type of bonfire (oil or wood) or the amount of liquid in the test container. Occasionally, however, with hydrazine, hydrazine nitrate solution, and n-propyl nitrate, anomalous results occurred: there was either (a) no explosion or (b) an explosion of above average intensity. Ethylene oxide more nearly approximated the behavior of aviation gasoline than did the other monopropellants. In the rifle-fire tests, n-propyl nitrate appeared to be most shock- sensitive since it was exploded by all three types of ammunition. Hydrazine and hydrazine nitrate solution were exploded by the high-explosive ammunition, but not by the incendiary or .30-dber ammunition. Ethylene oxide was not exploded by any of the gunfire, but the liquid was ignited by both incendiary and high-explosive incendiary ammunition.

FIRING↗

Hydrocarbon concentrations in fire toxicity tests as an indication of flash fire propensity

The concentrations of hydrocarbons in the gases from fire toxicity tests are often determined to obtain an indication of their contribution to toxic effects and of the mechanisms of thermal decomposition. Because the gas compositions produced in the University of San Francisco/NASA toxicity screening test are generated under identical pyrolysis conditions, they offer the potential of comparing the flash-fire propensity of various materials.

Hilado, C. J.↗

Hot fire fatigue testing results for the compliant combustion chamber

A hydrogen-oxygen subscale rocket combustion chamber was designed incorporating an advanced design concept to reduce strain and increase life. The design permits unrestrained thermal expansion of a circumferential direction and, thereby, provides structural compliance during the thermal cycling of hot-fire testing. The chamber was built and test fired at a chamber pressure of 4137 kN/sq m (600 psia) and a hydrogen-oxygen mixture ratio of 6.0. Compared with a conventional milled-channel configuration, the new structurally compliant chamber had a 134 or 287 percent increase in fatigue life, depending on the life predicted for the conventional configuration.

Pavli, Albert J.↗

Instrumentation Cables Test Plan

A fire at a nuclear power plant (NPP) has the potential to damage structures, systems, and components important to safety, if not promptly detected and suppressed. At Browns Ferry Nuclear Power Plant on March 22, 1975, a fire in the reactor building damaged electrical power and control systems. Damage to instrumentation cables impeded the function of both normal and standby reactor coolant systems, and degraded the operators’ plant monitoring capability. This event resulted in additional NRC involvement with utilities to ensure that NPPs are properly protected from fire as intended by the NRC principle design criteria (i.e., general design criteria 3, Fire Protection). Current guidance and methods for both deterministic and performance based approaches typically make conservative (bounding) assumptions regarding the fire-induced failure modes of instrumentation cables and those failure modes effects on component and system response. Numerous fire testing programs have been conducted in the past to evaluate the failure modes and effects of electrical cables exposed to severe thermal conditions. However, that testing has primarily focused on control circuits with only a limited number of tests performed on instrumentation circuits. In 2001, the Nuclear Energy Institute (NEI) and the Electric Power Research Institute (EPRI) conducted a series of cable fire tests designed to address specific aspects of the cable failure and circuit fault issues of concern1. The NRC was invited to observe and participate in that program. The NRC sponsored Sandia National Laboratories to support this participation, whom among other things, added a 4-20 mA instrumentation circuit and instrumentation cabling to six of the tests. Although limited, one insight drawn from those instrumentation circuits tests was that the failure characteristics appeared to depend on the cable insulation material. The results showed that for thermoset insulated cables, the instrument reading tended to drift and fluctuate, while the thermoplastic insulated cables, the instrument reading fell off-scale rapidly. From an operational point of view, the latter failure characteristics would likely be identified as a failure from the effects of fire, while the former may result in inaccurate readings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fire containment tests of aircraft interior panels

The paper describes an experimental program carried out to evaluate a possible method for testing the fire-containment qualities of aircraft interior panels. The experimental apparatus consisted of a burner that simulates various fire loads under different ventilation conditions in an enclosure of approximately the same size as an aircraft lavatory module. Two fire-containment tests are discussed in which two adjoining walls of the enclosure were made from state-of-the-art composite panels; rats were exposed to the combustion products in order to evaluate the toxic threat posed by those products. The results show that the burner can be employed to represent various fire-load conditions and that the methodology developed for fire containment can be useful in evaluating the fire resistance of composite panels before conducting large-scale tests. It is concluded that elements of the fire-containment criteria include the temperature rise on the backface of the panels as a function of time, the flame burn-through by either decomposition or severe distortion of the material, and the toxicity of the combustion gases evolved.

Kourtides, D. A.↗

Centaur space vehicle pressurized propellant feed system tests

Engine firing tests, using a full-scale flight-weight vehicle, were performed to evaluate a pressurized propellant feed system for the Centaur. The pressurant gases used were helium and hydrogen. The system was designed to replace the boost pumps currently used on Centaur. Two liquid oxygen tank pressurization modes were studied: (1) directly into the ullage and (2) below the propellant surface. Test results showed the two Centaur RL10 engines could be started and run over the range of expected flight variables. No system instabilities were encountered. Measured pressurization gas quantities agreed well with analytically predicted values.

Source record↗

Materials Science Research Rack-1 Fire Suppressant Distribution Test Report

Fire suppressant distribution testing was performed on the Materials Science Research Rack-1 (MSRR-1), a furnace facility payload that will be installed in the U.S. Lab module of the International Space Station. Unlike racks that were tested previously, the MSRR-1 uses the Active Rack Isolation System (ARIS) to reduce vibration on experiments, so the effects of ARIS on fire suppressant distribution were unknown. Two tests were performed to map the distribution of CO2 fire suppressant throughout a mockup of the MSRR-1 designed to have the same component volumes and flowpath restrictions as the flight rack. For the first test, the average maximum CO2 concentration for the rack was 60 percent, achieved within 45 s of discharge initiation, meeting the requirement to reach 50 percent throughout the rack within 1 min. For the second test, one of the experiment mockups was removed to provide a worst-case configuration, and the average maximum CO2 concentration for the rack was 58 percent. Comparing the results of this testing with results from previous testing leads to several general conclusions that can be used to evaluate future racks. The MSRR-1 will meet the requirements for fire suppressant distribution. Primary factors that affect the ability to meet the CO2 distribution requirements are the free air volume in the rack and the total area and distribution of openings in the rack shell. The length of the suppressant flowpath and degree of tortuousness has little correlation with CO2 concentration. The total area of holes in the rack shell could be significantly increased. The free air volume could be significantly increased. To ensure the highest maximum CO2 concentration, the PFE nozzle should be inserted to the stop on the nozzle.

Wieland, P. O.↗