Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMAL CONVECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The influence of boundary and edge-plasma modeling in computations of axisymmetric vertical displacement

A number of previously published studies apply extended-MHD computations to model macroscopic dynamics of tokamak vertical displacement events (VDEs). The characteristic plasma-wall contact and resistive-wall diffusion imply sensitivity to boundary conditions in a general sense, but which conditions have significant influence depends on how the plasma is modeled. This work examines these dependencies by comparing results of axisymmetric extended-MHD computations with different sets of boundary conditions, plasma thermal-conduction models, and wall resistivity values. The geometry and plasma parameters of the computations represent a modest-sized tokamak. The forced-displacement scenario and computational setup are similar to those used in previous 3D computations. The results show that for a given wall resistivity, the VDE time-scale is most sensitive to variations in the boundary and thermal-conduction parameters that affect electron thermal transport. The electrical conductivity depends on electron temperature, and the dependence on thermal transport stems from its influence on the electrical circuit that includes the open-field halo current. Lastly, conditions that lead to hotter, broader halo regions slow the evolution. Significant sensitivity to the boundary condition on plasma flow-velocity exists when electron thermal conduction is restricted and electron energy loss is convective, which is expected for conditions at the entrance of the magnetic presheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cooling performance of an active-passive hybrid composite phase change material (HcPCM) finned heat sink: Constant operating mode

Here, the present study explores a hybrid thermal management technology based on air cooling and hybrid composite phase change material (HcPCM) filled finned heat sink for cooling performance of lower to medium heat flux dissipating electronic devices. Two-dimensional numerical simulations are conducted to study the conjugate heat transfer effects of three types of finned heat sink: air-cooled finned heat sink, HcPCM-cooled finned heat sink, and hybrid (air-HcPCM) cooled finned heat sink. A heat sink with a constant volume faction of plate-fins is designed in all cases and simultaneous effects of hybrid nanoparticles and air are investigated to keep the heat sink temperature at safe operating conditions between 40–60°C. The effect of air is incorporated into the heat sink by applying the convective heat transfer coefficient of h c = 10–100W /m 2 .K which tends to create the natural convection and forced convection heat transfer characteristics. The heat flux is varied from 25–40kW /m 2 in the current study. The hybrid nanoparticles of carbon additives (GO and MWCNTs) are dispersed into the RT-35HC, used as a PCM, with a volume fraction of 0% to 6%. Transient simulations are carried out using COMSOL Multiphysics to solve the governing equations for PCM based conjugate heat transfer model. The results showed that forced convection heat transfer improved the cooling performance of the hybrid heat sink compared to natural convection heat transfer. The addition of nanoparticles further enhanced thermal enhancement and uniform melting distribution of PCM inside the finned heat sink. The h c between 30 to 50W/m 2 .K shows optimized values for forced convection heat transfer operating conditions. The volume fraction of 2% of GO+MWCNTs nanoparticles in recommended or optimum concentration for uniform melting of PCM inside the finned heat sink.

36 MATERIALS SCIENCE↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Single-Phase Dielectric Fluid Thermal Management for Power-Dense Automotive Power Electronics

This paper describes the design and performance of a dielectric fluid cooling concept for automotive power electronics. The concept combines a low-thermal-resistance package (which eliminates metalized ceramic substrates) with a high-performance convective cooling strategy (slot jets impinging on finned surfaces). Modeling was first used to design the cooling system to maximize thermal performance and minimize pumping power. Additionally, a prototype was then fabricated, and experiments were conducted to validate the model predictions using three fluids at various fluid flow rates (16.7 cm 3 /s [1 L/min] to 68.3 cm 3 /s [4.1 L/min]) and inlet temperatures (30C and 70C). The final design was compact (120-cm 3 total volume, including heat exchanger and conceptual power modules) and cooled 12 devices (e.g., silicon carbide). The validated model was then used to predict the junction-to-fluid thermal resistance and pumping power for various conditions, including 40C fluid temperature. The results predict thermal resistance values as low as 19 mm 2 K/W are possible using the dielectric fluid cooling approach. The dielectric fluid cooling system is predicted to provide thermal resistance and pumping power values that are approximately 56% and 90% lower, respectively, compared to an automotive power electronics cooling system.

30 DIRECT ENERGY CONVERSION↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Viewing convection as a solar farm phenomenon broadens modern power predictions for solar photovoltaics

We report heat mitigation for large-scale solar photovoltaic (PV) arrays is crucial to extend lifetime and energy harvesting capacity. PV module temperature is dependent on site-specific farm geometry, yet common predictions consider panel-scale and environmental factors only. Here, we characterize convective cooling in diverse PV array designs, capturing combined effects of spatial and atmospheric variation on panel temperature and production. Parameters, including row spacing, panel inclination, module height, and wind velocity, are explored through wind tunnel experiments, high-resolution numerical simulations, and operating field data. A length scale based on fractal lacunarity encapsulates all aspects of arrangement (angle, height, etc.) in a single value. When applied to the Reynolds number Re within the canonical Nusselt number heat transfer correlation, lacunarity reveals a relationship between convection and farm-specific geometry. This correlation can be applied to existing and forthcoming array designs to optimize convective cooling, ultimately increasing production and PV cell life.

14 SOLAR ENERGY↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

Native Natural circulation in VERA

This work seeks to introduce a native natural circulation solver to VERA's thermohydraulics capabilities. This work begins with initial investigations into the viability of such a solver by determining the fundamental equations as well as necessary inputs. The method was then implemented in the form of a Python script coupled to CTF which was compared to TRACE. Once viability of the natural circulation solver was established, it was then implemented natively in MPACT for use with previously created simplified thermohydraulics solvers. This new implementation of the native natural circulation solver in MPACT is then tested for single physics problems for both a BWR and PWR single channel model and compared to TRACE where it shows an error of about 30% for BWRs and about 15% for PWRs. The solver is additionally tested for NuScale based models where it demonstrates an error to the reported flow rate of about 10%, resulting in an eigenvalue error of only 138 pcm when comparing fixed flow rate multiphysics runs. Finally, the solver is tested in multiphysics systems for a small PWR assembly, a small BWR assembly, and a full core approximate model of the NuScale design. In these multiphysics runs, it demonstrates no impact on multiphysics convergence stability, as well as negligible impact on runtimes. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Influence of Soil Properties on Sea-Breeze Circulations in the Southeast U.S.

Sea-breeze circulations (SBCs) are common weather phenomena at and near coastal regions. They form because of a thermal gradient between the land surface at the coast and the sea surface. In a mid-day regime, a “thermal low” generated at the warm coast will lead to rising air motion, creating a wind shift coming from the sea near the surface displacing the coastal air. A “return flow” moving back towards the sea is generated by upper-level divergence because of the rising motion from the thermal low. SBCs propagate and serve as a method of urban pollutant dispersion in the Los Angeles region of California and are constrained to the coast due to the topography of surrounding mountains serving as a boundary for further inland propagation. Within the northeast U.S. SBCs are seen in the warm season but tend to remain coastally bound due to Coriolis distortion over long distances. Within the southeast U.S. (SEUS), the paradigmatic example of SBCs occurs over the Florida peninsula, where thunderstorms form on a nearly daily occurrence due to the convergence of SBCs from the east and west sides of the peninsula. However, there are further examples of sea-breezes in the SEUS that warrant study. Within the region bordering the SEUS and the Mid-Atlantic, just east of the southern Appalachian Mountains, warm-season SBCs form at the coast of Georgia and the Carolinas. Relatively flat topography ~150-200km inland allows for mostly unimpeded inland SBC propagation. Through visual analysis, Viner et al. catalogued several SBCs that propagated as far inland as the Central Savannah River Area surrounding Augusta, Georgia. Wermter et al. found that while the land-sea thermal gradient at the coast can influence coastal SBC genesis, the inland-coastal thermal gradient over the land is the primary influencer on the speed and depth of inland propagation of SBCs in this region. Additionally, soil moisture itself is a known correlative factor to sea-breeze formation, as it influences the soil temperature and the thermal gradient needed for SBC genesis and inland penetration. Physick determined that higher latent heat fluxes associated with wetter soil dampen the land-sea thermal gradient and suppress the formation of a SBC. Physick determined that higher latent heat fluxes associated with wetter soil dampen the land-sea thermal gradient and suppress the formation of a SBC. Conversely, drier soil enhances the thermal gradient and promotes SBC formation. However, while there is an inverse relationship between soil moisture and SBCs, higher soil moisture can actually promote more convective rainfall following a SBC if it does not significantly impact the thermal gradient. While the relationship between soil moisture and SBC formation has been conceptually explored and modeled numerically, there is a research gap in observed connections. The Soil Moisture Active Passive (SMAP) satellite mission has been operational since 2015 and has been used to create high-resolution re-analytical Level 4 (L4) datasets of soil moisture and soil temperature at different soil depths: the surface (0-5cm) and rootzone (0-1m). The surface soil temperature effectively acts as the “skin temperature” of the surface at these levels, and a spatial map of the land-sea as well as the coastal-inland thermal gradients can be represented. SMAP data are also assimilated in some atmospheric models such at the High Resolution Rapid Refresh (HRRR) mesoscale model. We propose leveraging the use of SMAP products to fill in spatial gaps left by weather and mesonet stations within the SEUS region, as well as assessing the effectiveness of utilizing SMAP products towards SBC forecasting in both deterministic and machine learning (ML) models.

58 GEOSCIENCES↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Radiative Heat Transport and Optical Characterization of High Temperature Molten Salts

The goal of this project was to advance the field of molten fluoride radiative heat transfer (RHT), through optical property measurements, heat transfer loop construction and operation, and computational fluid dynamics simulations. The following outcomes have been accomplished. A comprehensive review has been conducted to compile all available RHT-relevant optical absorption data for molten fluorides. The various measurement methods have also been compiled and critiqued. Thermal emission measurement methods have been refined and documented. A unique thermal emissivity measurement facility has been constructed and used to measure the emissivity of flowing FLiBe-exposed SS316 samples. A slight increase has been observed in the emissivity compared to unexposed SS316. A dual reflectance-emission setup was partially demonstrated for the purpose of molten fluoride absorption measurement. Preliminary infrared edge data for FLiNaK was obtained. A visible near-infrared (NIR) measurement setup has been constructed and will be used to measure absorption of corrosion products in FLiBe. A new multi-band thermal radiation method using blackbody-weighted spectral bands for the absorption-coefficient was deployed to investigate the thermal performance of the UW Natural Circulation FLiBe Loop under various power levels and operating conditions. The results showed an increasing and decreasing trend in the overall heat transfer with optical thickness with a maximum at optical thickness τ D ≈Ο(1). A forced convection FLiBe loop was constructed for the purpose of studying corrosion and thermal hydraulic phenomena. A vertical cantilever pump is used to achieve up to 5 gpm and 5 m/s flow velocity in hot and cold test sections. A methodology has been established for modeling radiative heat transfer (RHT) in molten salt coolants for the purpose of quantifying the contribution of thermal radiation in conditions relevant to FHR or MSR systems. The comparison between the results obtained for forced and mixed convection showed that in the studied ranges of optical thickness, the maximum effect of RHT on overall heat transfer was 60% improvement observed at z/D = 250 for forced convection; whereas for mixed convection, that value was higher at 170% observed at z/D = 30. The highest effect of RHT on the overall energy distribution was observed at τ D ≈3.4. Negligible effect (<20%) was observed above τ D =18 and below τ D ≈0.002. A CFD code-to-code comparison was conducted using COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT, for a forced and mixed convection laminar flow for a grey medium in a vertical heated using both COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT. The relative error was the largest at τ D =40 for the radiative heat flux, bulk temperature, and Nusselt number. On the other hand, the relative error was the least at τ D =0.002 for the conductive heat flux, bulk temperature, and Nusselt number.

Anderson, Mark↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

CFD modeling and simulation for corrosive wear of refractory in molten slag

The development of high-wear resistant refractories having minimal production costs is facilitated by characterizing the wear mechanisms associated with their corrosive wear. Static cup testing is a commonly used method for comparing the corrosion resistance performance of two or more refractory materials. Although the static cup test conditions are not as severe as dynamic tests, this study shows that the thermal gradient present within the system during heating and cooling stages serves to generate movement of the slag leading to mechanical wear. The thermal gradient within the refractory, and between the slag and the refractory, occurs during the ramp stage of the test and lasts until the soaking stage is reached bringing the system to a thermal equilibrium. Using computational fluid dynamics (CFD) capabilities embedded within ANSYS software, this study modelled and quantified the convection currents within the slag and associated shear stresses generated on the refractory walls due to the thermal gradient. A traditional ladle furnace was employed as a case study to verify the results of the studied CFD model. The corrosion rate of the refractory lining was found to depend on the mass transfer coefficient of the refractory dissolution into the slag, and a velocity term which governs the extent of corrosion at any given location. This velocity term is a function of slag viscosity, as well as the concentration gradient and/or temperature gradient at the triple points. In this study, wall shear stress was used as a reliable proxy for identifying high-velocity regions prone to excessive corrosive wear. Elevated wall shear stress near the slag/air and slag/molten steel interfaces align with observed corrosion grooves, which reflects the intensified corrosive wear at these locations.

Ramteke, Rajat Rajat Durgesh Ramteke [University o↗

Effect of cold-cap-bottom shear stress on primary foam stability

Here, we analyze the heat transfer between the melt pool and the layer of reacting materials called cold cap, which is the determining factor for the glass production rate in Joule-heated air-bubbled nuclear waste glass melters. We consider the effects of bubbling rate, melt viscosity, melt thermal conductivity, conversion kinetics, and shear rate at the cold-cap bottom, and develop simple relationships for the cold-cap bottom temperature and glass production rate. We show that the melt convection enhances the heat transfer to the cold cap by suppressing the thermal boundary layer and primary foam, while the conversion kinetics opposes these effects. Additionally, we mention how dissolving silica particles affects the primary foam stability and discuss the limitations of the presented approach for vigorously foaming feeds.

36 MATERIALS SCIENCE↗

Demonstration of gold nanorod systems for enhanced total efficiency: Experimental and numerical analysis

This study investigates the photothermal performance of gold nanorods engineered to exhibit longitudinal plasmon resonances at 695 nm, 780 nm, and 970 nm. The work combines synthesis, structural characterization, extinction measurements, numerical modeling, and controlled temperature experiments to quantify how nanorod geometry, resonance tuning, concentration, and chamber shape jointly influence heat generation. Transmission electron microscopy confirms that increasing nanorod aspect ratio systematically shifts the longitudinal plasmon peak toward the near-infrared region. Extinction measurements show strong agreement with theoretical predictions, validating the numerical model across two independent datasets. Three chamber geometries were tested under laser excitation at 640 nm, 808 nm, and 980 nm: an ascending stepped base, a flat base, and a descending stepped base. Without nanorods, the ascending geometry produced the highest efficiency due to enhanced natural convection. After introducing gold nanorods, all geometries exhibited substantial thermal enhancement, with total efficiencies exceeding 20%. The strongest improvement was obtained for nanorods resonant at 780 nm with a mass concentration of 4.6 mg/mL implemented on the descending stepped-base geometry. This performance resulted from the combined effect of spectral overlapping with the 808 nm laser, the highest nanorod concentration, and localized heat accumulation that intensified buoyancy-driven flow. The findings demonstrate that total efficiency is governed by a synergistic interplay between optical resonance, nanoparticle concentration, and macroscopic chamber design, revealing the system-level coupling between nanoscale plasmonic absorption and macroscale heat-transfer phenomena. The results provide a validated framework for tuning nanoscale plasmonic absorbers and optimizing thermal systems for applications requiring efficient light-to-heat conversion.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An analysis of parameters affecting ampacity in aircraft bipolar MVDC power cables via coupled electrical, thermal, and computational fluid dynamic modelling

Abstract The next generation of aircraft, including more electric aircraft and all‐electric aircraft (AEA), requires electric power systems with high power density and low system mass specifications. Increasing the voltage of the system to the range of a few kV, medium voltage (MV), is a reasonable approach to achieving high‐power‐density and low‐system‐mass EPSs for aircraft applications. Higher voltages, however, pose many challenges for aviation MV power cables such as arcs and arc tracking, partial discharges (PDs), and thermal management. In this regard, thermal management is more challenging since heat transfer by convection is greatly reduced at wide‐body aircraft's cruising altitudes due to the reduced air pressure. In this paper, a finite element method (FEM) model is developed in COMSOL Multiphysics for an aircraft bipolar MVDC (±5 kV) power cable. Using the model, the maximum permissible cable current at a low pressure of 18.8 kPa (at an altitude of 12.2 km from sea level, the usual cruising altitude for wide‐body aircraft) is calculated. Also, an analytical model is developed based on analytical and proven empirical correlations governing conductive, radiative, and convective heat transfers at the steady state to estimate the ampacity of the bipolar cable system at reduced pressure. It was shown that the proposed analytical model can be used for atmospheric pressure and systems with a larger number of poles, expanding its range of applications. The results of the FEM and analytical models correlate at wide ranges of parameters such as ambient temperature, duct size, distance between the positive and negative pole cables, and the overall diameter of the cables. The influence of horizontal and vertical arrangement of poles is included in the analytical model. The results of this study can be used to design bipolar MVDC power cable systems for the envisaged wide‐body AEA.

Azizi, Arian↗

The glass-ceiling convective regime and the origin and diversity of coronae on Venus

Venus and Earth are rocky planets of roughly the same size and bulk density, yet their surface volcanic and tectonic features appear substantially different. On Venus, the coexistence of large volcanic highlands—interpreted as the surface expression of long-lived mantle plumes—alongside coronae, smaller features thought to be caused by transient thermal diapirs, remains enigmatic. Using two-dimensional numerical models of mantle convection with sharp and broad mineral phase transitions for pyrolite, we show that both scales of upwellings can be generated in a stagnant lid planet with an interior temperature 250 to 400 K warmer than Earth’s. The smaller plumes originate from a ~600 km deep internal layer that exists as a consequence of the different sequence of mineral phase transitions that occur in warmer mantles less processed and differentiated by partial melting and volcanism. Future models that include melting will provide further tests of our hypothesis.

Science & Technology - Other Topics↗