At least 145 records · Page 8

Function and Operational Requirements for High-Temperature Irradiation-Resistant Thermocouples

The function and operation requirements for the high-temperature irradiation-resistant thermocouple (HTIR-TC) are set forth. A mission and product are proposed. The function and operational requirements involve temperature range, accuracy, drift, life, mechanical ruggedness, and response time. Each have a criterion set to establish a thermocouple that can withstand a typical 18-month nuclear power plant refueling cycle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-temperature irradiation-resistant thermocouple instability model for in-pile reactor use

This article presents an instability model for the high-temperature irradiation-resistant thermocouple (HTIR-TC). Here the term instability defines the superposition of both drift and inhomogeneity of TC thermoelements occurring simultaneously. The HTIR-TC is an advanced thermocouple (TC) that uses the refractory metals niobium and molybdenum as sensing thermoelements for generating electromotive force (EMF) in a field of neutrons and at temperatures upward of 1,600°C. In the Advanced Gas Reactor (AGR) 5/6/7 tests conducted at Idaho National Laboratory’s Advanced Test Reactor (ATR), the HTIR-TCs showed low to moderate instability throughout the life of the test. The instability model reveals that HTIR-TCs can, when the operating temperature of the reactor fuel is normal, maintain performance throughout an 18-month refueling cycle typical of nuclear power plants, reflecting an instability of less than ±1%. The HTIR-TC is also qualified for incorporation into a test fixture during the testing of new fuels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary 3D Simulations of Anomalous Thermocouple Coupling to Surface Electric Fields

Anomalous measurements from subsurface thermocouples have been observed during re-entry of the Orion capsule (EFT-1 plugs). These measurements are considered anomalous because the amplitude and frequency of the inferred temperature modulations are too large to be due to plausible heating processes. Consequently, it is believed the anomalies are caused by electrical interference generated by the re-entry plasma. Quantifying these effects requires several steps: modeling the external plasma flows, modeling the plasma-surface interaction, and finally modeling the surface-thermocouple coupling. This paper addresses this last step using 3D finite element simulations of a wire embedded in a weakly conductive medium.

thermocouple anomaly↗

Summary of High Temperature Irradiation Resistant Thermocouple Standarization Tests

Over the preceding ten years, continual research and development has been performed on the high temperature irradiation resistant thermocouple (HTIR-TC) by the team at Idaho National Laboratories (INL) High Temperature Test Laboratory (HTTL). The HTIR-TC has the capability of achieving high temperatures up to 1600°C or more. Further, the HTIR-TC has gone through many longevity tests both in and out of pile to show the amount of drift is minimal compared standard thermocouples. Key considerations for properties and materials of the HTIR-TC have been final diameter, ductility after heat treatment, and minimizing transmutation of materials during operation. Further, heat treatment and calibration processes have been established in order to consistently produce repeatable and reliable temperature readings. The current work provides further background for the standardization process of the HTIR-TC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic Junction Thermocouples For Surface Temperature Measurement

The material selection, attachment, and calibration of intrinsic junction thermocouples is discussed. Intrinsic junction thermocouples are utilized for their fast response times in surface measurements during high thermal transients. The as-is measurement and calibrated corrections are presented for both the out-of-pile pulse power system and the critical heat flux experiments in the Idaho National Laboratory Transient Reactor Test facility. The fin effect from temperature measurements on the surface of fuel cladding is corrected using a linear coefficient, m, and temperature corrections are sometimes 100 °C or more—representing 18% of the original temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of Joule Heating on the Stability of High Temperature Irradiation Resistant Thermocouples

Development of in-core instrumentation is driven by the pursuit of safer and more economic energy production from both existing nuclear reactors and Generation IV reactor designs. Idaho National Laboratory (INL) has developed high temperature irradiation resistant thermocouples (HTIR-TCs) for temperature sensing inside Generation IV nuclear reactors. These thermocouples are composed of phosphorus-doped niobium (Nb-P) and lanthana-doped molybdenum (Mo-LaO) thermoelements, an alumina (Al2O3) insulation, and a niobium sheath. HTIR-TCs require an initial heat treatment exceeding the maximum service temperature to stabilize the generated electromotive force (EMF) signal; however, the mechanism behind this stabilization is not well understood. This work evaluates the impact of Joule heating on the thermoelements' microstructures, chemical stability, and mechanical properties to determine the mechanisms by which the EMF signal stabilization occurs. Accordingly, during the Joule heat treatment, a secondary Nb3P phase coarsened along the length of the Nb-P thermoelement, along with the formation of an interaction region at the Al2O3/niobium interface. The interaction between the alumina insulation and the Nb-P thermoelement was also observed within the Mo-LaO thermoelement. Joule heating induced stability within the generated EMF signal of HTIR-TCs through the formation of secondary phases within the Nb-P and the interaction of the alumina insulation with the thermoelements.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

HIGH TEMPERATURE IRRADIATION RESISTANT THERMOCOUPLES – A LOW COST SENSOR FOR IN-PILE TESTING AT HIGH TEMPERATURES

Several options have been identified to improve recently-developed Idaho National Laboratory (INL) High Temperature Irradiation Resistant ThermoCouples (HTIR-TCs) for in-pile testing. These options have the potential to reduce fabrication costs and allow HTIR-TC use in higher temperature applications (up to at least 1800 °C). The INL and the University of Idaho (UI) investigated these options with the ultimate objective of providing recommendations for alternate thermocouple designs that are optimized for various applications. This paper summarizes results from these INL/UI investigations. Specifically, results are reported about several options found to enhance HTIR-TC performance, such as improved heat treatments, alternate geometries, alternate fabrication techniques, and the use of copper/nickel alloys as soft extension cable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Temperature Irradiation-Resistant Thermocouple Performance Improvements

Traditional methods for measuring temperature in-pile degrade at temperatures above 1100 ºC. To address this instrumentation need, the Idaho National Laboratory (INL) developed and evaluated the performance of a high temperature irradiation-resistant thermocouple (HTIR-TC) that contains alloys of molybdenum and niobium. Data from high temperature (up to 1500 ºC) long duration (up to 4000 hours) tests and on-going irradiations at INL’s Advanced Test Reactor demonstrate the superiority of these sensors to commercially-available thermocouples. However, several options have been identified that could further enhance their reliability, reduce their production costs, and allow their use in a wider range of operating conditions. This paper presents results from on-going Idaho National Laboratory (INL)/University of Idaho (UI) efforts to investigate options to improve HTIR-TC ductility, reliability, and resolution by investigating specially-formulated alloys of molybdenum and niobium and alternate diameter thermoelements (wires). In addition, on-going efforts to evaluate alternate fabrication approaches, such as drawn and loose assembly techniques will be discussed. Efforts to reduce HTIR-TC fabrication costs, such as the use of less expensive extension cable will also be presented. Finally, customized HTIR-TC designs developed for specific customer needs will be summarized to emphasize the varied conditions under which these sensors may be used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermocouple and RTD Drift Due to Neutron Irradiation and Temperature for Space Nuclear Applications: A Review

Temperature measurement is a key factor in the safe and reliable operation of nuclear reactors. Thermocouples and resistance temperature detectors (RTDs) are among the most common and reliable tools deployed for temperature measurement, and some are capable of operating in extreme environments such as very high temperature and neutron radiation fields anticipated in nuclear thermal propulsion (NTP) or fission surface power. These devices are known to exhibit drifting behavior in their temperature readings throughout their operational lifetimes. Here, to help select appropriate instrumentation, it is important to identify the factors that influence drift as well as typical behavior in these environments. This work is focused on identifying contributing factors in the performance of thermocouples and RTDs. An extensive literature review is included that discusses several experimental results in different environments. Although individual instrument performance may vary with construction methods, materials selection, and vendors, this review aims to assist in the selection process and identify typical expected behaviors of several devices.

Chesser, Ryan J. [Oak Ridge National Laboratory (O↗

Connector for thermocouple leads saves costly wire, makes reliable connectors

A connector for use in the thermocouple circuits which is silver-brazed to the metal thermocouple sheath on one end and crimped over the insulation of the flexible lead on the other, assures protection against breakage and abrasion. A moisture-proof insulating material is used to encapsulate the wire junctions.

Miller, H. B.↗

Liquid trap seals thermocouple leads

Liquid trap seals thermocouple leads coming out of a brazing retort that operates with a controlled atmosphere so that air cannot enter the retort and hydrogen cannot escape. The trap is fastened to a duct welded to the retort. Thermocouple leads are led out through the duct and trap, with the fluid forming a gastight seal between the atmosphere and the retort.

Ruppe, E. P.↗

Modified thermocouple is effective from minus 250 deg to 5000 deg F

Modified, commercially available thermocouple which measures the temperature of a spacecraft heat shield, is capable of continuous measurement in the range of minus 250 deg to 5000 deg F. The modified thermocouples may be used inside metal treating furnaces in high temperature technology, and in certain corrosive environments.

Moen, W. K.↗

Microminiature thermocouple monitors own installation

Microminiature thermocouple makes precision gas sidewall temperature readings inside large thrust chambers. It is installed by a technique whereby the sensor monitors its own installation to insure against thermal damage to the thermocouple and ensure minimum disturbance to chamber surfaces.

Garrett, A. J.↗

Thermocouples electrically checked while connected to data system

Constant current source is connected across the input of the millivolt measuring system to monitor the electrical continuity and resistance of multiple thermocouple installations without disconnecting them from a data system. This technique monitored gage thermocouple leads during the assembly and preflight testing of the Project Fire reentry packages.

Source record↗

Thermocouples easily installed in hard-to- get-to places

Thermocouple wires attached to charged capacitors are inserted in a drilled hole. An electric charge fuses the thermocouple wires to the host material. This method has shown excellent results in fusing nichrome, chromel, Inconel, and stainless steel wires to nickel, beryllium, iron, steel, Inconel, and stainless steel.

Guenther, F. G.↗

Study of fast response thermocouple measurement of temperatures in cryogenic gases

Thermocouples fabricated from uninsulated small diameter wire have fast reproducible response times. The thermocouple is thermally isolated from its supports by making the leads of sufficient length so that the heat conduction down the leads is small and assuming that the leads adjacent to the junction are subjected to the same thermal conditions.

Bielawski, T.↗