Search NASA⌕ Search

SEARCH · Search NASA

Results for “THRESHOLD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The effect of plasma shape and neutral beam mix on the rotation threshold for RMP-ELM suppression

Varying the neutral beam injection (NBI) mix reveals a clear pedestal-top rotation threshold for edge localized mode (ELM) suppression by resonant magnetic perturbations. Guided by expectations for the RMP penetration mechanism, the rotation threshold is found to correspond to a critical radius for the ExB rotation zero-crossing. No such critical radius is observed for the electron perpendicular rotation zero-crossing. Varying the amount and ratio of power in different NBI source geometries (termed the NBI mix) also reveals that the rotation threshold can be crossed at widely varying total injected NBI torques. Computing the local torque density at the edge, the rotation threshold is found to be crossed when the local edge NBI torque is negative in nearly all discharges. Reducing the upper triangularity (delta_up ) from the ITER-similar value of 0.3 to 0.1 significantly reduces the pedestal height and width. This in turn: 1) Increases the rotation threshold and yields a more outward critical ExB rotation zero-crossing location. 2) Decreases the density threshold, consistent with a comparable collisionality range at lower pedestal temperatures. 3) Increases the input torque requirement, due to observed lower confinement and smaller intrinsic torque. These findings represent an important step along the road to predicting ELM suppression access conditions in future tokamaks such as ITER, where the toroidal rotation is expected to be low and consequently the rotation zero-crossing far from the pedestal-top.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear modeling of the scaling law for the m/n = 3/2 error field penetration threshold

The scaling law for the m/n=3/2 error field (EF) penetration threshold is predicted numerically based on nonlinear single-fluid and two-fluid modeling using the TM1 code. The simulated penetration threshold of radial magnetic field b r at the plasma edge is scaled to the electron density n e , temperature T e , viscous time τ μ , toroidal field B t and the natural frequency ω in the form of b r /B t ∝n e αn T e αT τ μ αμ B t αB ω αω by scanning these parameters separately. Here, α n , α T , α μ , α B and α ω are the scaling coefficients on n e , T e , τ μ , B t and ω, respectively. Single-fluid modeling shows that the 3/2 EF threshold scales as b r /B t ∝n e 0.56 T e 0.6 τ μ -0.59 B t -1.15 ω, which is similar with the analytical scaling law in both the Rutherford and visco-resistive regimes. Yet, two-fluid modeling shows that the scaling law differs significantly in particular regarding the dependence on plasma rotation. In detail, the scaling coefficient α n on density decreases from 0.67 to 0.56 and α T on temperature decreases from 0.67 to 0.32, while α μ on viscous time is around -0.45 and α B on toroidal field decreases slightly from -1.15 to -1, when the ratio |ω E /ω *e | between plasma rotation frequency ω E and diamagnetic drift frequency ω *e varies from 0 to 10. Scans of the plasma rotation reveals that the penetration threshold linearly depends on the perpendicular rotation frequency (or natural frequency) ω ⊥e =ω E +ω *e , and there is a minimum in the required field amplitude when ω ⊥e 0. In addition, the enduring mystery of non-zero penetration threshold at zero plasma natural frequency in EF experiments is resolved by two-fluid simulations. We report that the very small island and smooth bifurcation in EF penetration near zero frequency is hard to detect in the experiment, leading to a finite penetration threshold within the capability of the experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Metrics and extrapolation of resonant magnetic perturbation thresholds for ELM suppression

This large database study of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression thresholds in the AUG, DIII-D, EAST, and KSTAR tokamaks details the key strengths and weaknesses of RMP metrics. The RMP ELM suppression database used for this work contains plasma information at the time of transition from ELMing to ELM suppressed states where a clear experimental threshold is identified. The experimental threshold distributions are compared for five metrics: (1) the island overlap width, (2) pedestal top Chirikov overlap, (3) peeling edge displacement, (4) pedestal top resonant drive, and (5) edge dominant mode overlap. The distributions, the regularity of the dependence on RMP coil currents, and the sensitivities of a given metric to equilibrium reconstruction details are compared. The overlap metric proves to be a good compromise between including the appropriate plasma response physics and maintaining a numerical robustness. This quantity does not exhibit clear power-law scalings for projection, but machine learning can assist in predicting thresholds within the existing parameter ranges and providing uncertainty quantification of those predictions. Two new first-principles models, one utilizing a threshold from the non-linear Modified Rutherford equation evaluated at the pedestal top and one utilizing the SLAYER code to calculate the linear tearing threshold from torque balance, offer possible paths to extrapolation beyond the existing database parameter space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benefits of colorectal cancer screening using fecal immunochemical testing with varying positivity thresholds by age and sex

Background Fecal immunochemical test (FIT) performance for colorectal cancer screening varies by age and sex, yet most FIT-based screening programs use uniform positivity thresholds. This study assessed the potential benefits of stratifying FIT thresholds based on age and sex. Methods We conducted a meta-analysis of FIT sensitivity and specificity at various positivity thresholds by age and sex. We then used these estimates in 2 microsimulation models of colorectal cancer and projected lifetime clinical outcomes, incremental costs, and quality-adjusted life-years (QALYs) gained from age- and sex-stratified FIT strategies. FIT thresholds ranged from 10 to 50 µg hemoglobin per gram of feces. Results For current uniform FIT screening (20 µg hemoglobin/gram of feces), models projected 85.67 to 122.15 QALYs gained at incremental costs of ‒$982 to $504 per 1000 individuals compared with no screening. At equivalent costs to current uniform screening, only 1 model found stratified FIT approaches cost-effective, yielding a marginal increase of 1.04 and 1.10 QALYs gained/1000 female and male individuals, respectively. At a willingness-to-pay threshold of $100 000/QALYs gained, both models found stratified FIT cutoffs to be the best strategy, with cutoffs being equal to or higher for males and lowest at older ages (70-75 years). Uniform strategies showed comparable effectiveness, falling within 1 quality-adjusted life-day per person of efficient strategies at up to $112 more per person. Results were sensitive to FIT test performance characteristics and 1-time setup costs. Conclusion Stratifying FIT thresholds by age and sex may be cost-effective compared to current screening. The gain in expected health benefits with stratified FIT screening, however, is likely small.

Harlass, Matthias↗

Determining Star Formation Thresholds from Observations

Most gas in giant molecular clouds is relatively low-density and forms star inefficiently, converting only a small fraction of its mass to stars per dynamical time. However, star formation models generally predict the existence of a threshold density above which the process is efficient and most mass collapses to stars on a dynamical timescale. A number of authors have proposed observational techniques to search for a threshold density above which star formation is efficient, but it is unclear which of these techniques, if any, are reliable. In this paper we use detailed simulations of turbulent, magnetised star-forming clouds, including stellar radiation and outflow feedback, to investigate whether it is possible to recover star formation thresholds using current observational techniques. Using mock observations of the simulations at realistic resolutions, we show that plots of projected star formation efficiency per free-fall time ϵff can detect the presence of a threshold, but that the resolutions typical of current dust emission or absorption surveys are insufficient to determine its value. In contrast, proposed alternative diagnostics based on a change in the slope of the gas surface density versus star formation rate surface density (Kennicutt-Schmidt relation) or on the correlation between young stellar object counts and gas mass as a function of density are ineffective at detecting thresholds even when they are present. The signatures in these diagnostics sometimes taken as indicative of a threshold in observations, which we generally reproduce in our mock observations, do not prove to correspond to real physical features in the 3D gas distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron-hydrogen atom-impact 1s{yields}2s and 1s{yields}2p excitation with screened Coulomb interaction between the n=2 and n=3 excitation thresholds

The effects of Coulomb interaction screening on electron-hydrogen atom 1S {yields} 2S and 1S {yields} 2p excitation scattering between the n = 2 and n = 3 excitation thresholds have been investigated by using the R-matrix method with pseudostates. The excitation collision strengths show dramatic changes when the interaction screening length D varies from {infinity} to 9 a.u., as a result of the convergence of S-type and some p- and D-type Feshbach resonances to the varying 3S or 3p thresholds, and due to the crossover of some other p-, D- and all F-type Feshbach resonances into shape-type resonances when they pass across the 3S or 3p threshold at certain critical values of D. The noncrossover of some p- and D-type Feshbach resonances into shape-type resonances at the 3S (or 3p for those of D-type) threshold is at variance with the behavior of these types of resonances at the 2S (2p for those of D-type) threshold, which results from the threefold splitting of the n = 3 hydrogenic level and, consequently, the more complex nature of the configuration mixing in the n = 3 threshold region. The evolution of the total 1S {yields} 2S, 1S {yields} 2p, and 2S {yields} 2p excitation collision strengths, when the screening strength varies, is presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment Thresholds of Molecules

Molecules have long been known to align in moderately intense, far off-resonance laser fields with a large variety of applications in physics and optics. Here, we illustrate and describe the physical origin of a previously unexplored phenomenon in the adiabatic alignment dynamics of molecules, which is fundamentally interesting and also has an important practical implication. Specifically, the intensity dependence of the degree of adiabatic alignment exhibits a threshold behavior, below which molecules are isotropically distributed rotationally and above which the alignment rapidly reaches a plateau. Furthermore, we show that both the intensity and the temperature dependencies of the alignment of all linear molecules exhibit universal curves and derive analytical forms to describe these dependencies. Finally, we illustrate that the alignment threshold occurs very generally at a lower intensity than the off-resonance ionization threshold, a numerical observation that is readily illustrated analytically. The threshold behavior is attributed to a tunneling mechanism that rapidly switches off at the threshold intensity, where tunneling between the potential wells corresponding to the two orientations of the aligned molecules becomes impossible. The universal threshold behavior of molecular alignment is a simple phenomenon, but one that was not realized before and can be readily tested experimentally.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determination of action thresholds for electromagnetic tracking system-guided hypofractionated prostate radiotherapy using volumetric modulated arc therapy

Purpose: Hypofractionated prostate radiotherapy may benefit from both volumetric modulated arc therapy (VMAT) due to shortened treatment time and intrafraction real-time monitoring provided by implanted radiofrequency(RF) transponders. The authors investigate dosimetrically driven action thresholds (whether treatment needs to be interrupted and patient repositioned) in VMAT treatment with electromagnetic (EM) tracking. Methods: VMAT plans for five patients are generated for prescription doses of 32.5 and 42.5 Gy in five fractions. Planning target volume (PTV) encloses the clinical target volume (CTV) with a 3 mm margin at the prostate-rectal interface and 5 mm elsewhere. The VMAT delivery is modeled using 180 equi-spaced static beams. Intrafraction prostate motion is simulated in the plan by displacing the beam isocenter at each beam assuming rigid organ motion according to a previously recorded trajectory of the transponder centroid. The cumulative dose delivered in each fraction is summed over all beams. Two sets of 57 prostate motion trajectories were randomly selected to form a learning and a testing dataset. Dosimetric end points including CTV D95%, rectum wall D1cc, bladder wall D1cc, and urethra Dmax, are analyzed against motion characteristics including the maximum amplitude of the anterior-posterior (AP), superior-inferior (SI), and left-right components. Action thresholds are triggered when intrafraction motion causes any violations of dose constraints to target and organs at risk (OAR), so that treatment is interrupted and patient is repositioned. Results: Intrafraction motion has a little effect on CTV D95%, indicating PTV margins are adequate. Tight posterior and inferior action thresholds around 1 mm need to be set in a patient specific manner to spare organs at risk, especially when the prescription dose is 42.5 Gy. Advantages of setting patient specific action thresholds are to reduce false positive alarms by 25% when prescription dose is low, and increase the sensitivity of detecting dose limits violations by 30% when prescription dose is high, compared to a generic 2 mm action box. The sensitivity and specificity calculated from the testing dataset are consistent to the learning set, which indicates that the patient specific approach is reliable and reproducible within the scope of the prostate database. Conclusions: This work introduces a formalism for ensuring a VMAT delivery meets the most clinically important dose requirements by using patient specific and dosimetric-driven action thresholds to hold the beam and reposition the patient when necessary. Such methods can provide improved sensitivity and specificity compared to conventional methods, which assume directionally symmetric action thresholds.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The influence of crack closure on fatigue crack growth thresholds in 2024-T3 aluminum alloy

Crack opening loads were determined in load-shedding fatigue crack growth threshold tests on 2024-T3 aluminum alloy at stress ratios R of -2, -1, 0, 0.33, 0.5, and 0.7. The effects of load-shedding procedure and rate were investigated. Values of threshold Delta-K were found to vary significantly with R, whereas values of threshold effective Delta-K did not. That is, the variation of threshold Delta-K with R was almost completely explained by accounting for the measured variation in crack opening load behavior with R. The load-shedding guidelines of ASTM Test Method for Measurement of Fatigue Crack Growth (E 647) produced a threshold Delta-K value for R = 0.7 that was in agreement with the value determined using a procedure that should minimize closure effects. At both R = 0 and R = 0.7, high load-shedding rates produced high values of threshold Delta-K caused by large closure effects.

Phillips, Edward P.↗

Application of a Threshold Method to the TRMM Radar for the Estimation of Space-Time Rain Rate Statistics

One of the TRMM radar products of interest is the monthly-averaged rain rates over 5 x 5 degree cells. Clearly, the most directly way of calculating these and similar statistics is to compute them from the individual estimates made over the instantaneous field of view of the Instrument (4.3 km horizontal resolution). An alternative approach is the use of a threshold method. It has been established that over sufficiently large regions the fractional area above a rain rate threshold and the area-average rain rate are well correlated for particular choices of the threshold [e.g., Kedem et al., 19901]. A straightforward application of this method to the TRMM data would consist of the conversion of the individual reflectivity factors to rain rates followed by a calculation of the fraction of these that exceed a particular threshold. Previous results indicate that for thresholds near or at 5 mm/h, the correlation between this fractional area and the area-average rain rate is high. There are several drawbacks to this approach, however. At the TRMM radar frequency of 13.8 GHz the signal suffers attenuation so that the negative bias of the high resolution rain rate estimates will increase as the path attenuation increases. To establish a quantitative relationship between fractional area and area-average rain rate, an independent means of calculating the area-average rain rate is needed such as an array of rain gauges. This type of calibration procedure, however, is difficult for a spaceborne radar such as TRMM. To estimate a statistic other than the mean of the distribution requires, in general, a different choice of threshold and a different set of tuning parameters.

Meneghini, Robert↗

Suppression of Random Dopant-Induced Threshold Voltage Fluctuations in Sub-0.1-(micron)meter MOSFET's with Epitaxial and (delta)-Doped Channels

A detailed three-dimensional (3-D) statistical 'atomistic' simulation study of fluctuation-resistant sub-0.1-(micron)meter MOSFET architectures with epitaxial channels and delta doping is presented. The need for enhancing the fluctuation resistance of the sub-0.1-(micron)meter generation transistors is highlighted by presenting summarized results from atomistic simulations of a wide range of conventional devices with uniformly doped channel. According to our atomistic results, the doping concentration dependence of the random dopant-induced threshold voltage fluctuations in conventional devices is stronger than the analytically predicted fourth-root dependence. As a result of this, the scaling of such devices will be restricted by the "intrinsic" random dopant-induced fluctuations earlier than anticipated. Our atomistic simulations confirm that the introduction of a thin epitaxial layer in the MOSFET's channel can efficiently suppress the random dopant-induced threshold voltage fluctuations in sub-0.1-(micron)meter devices. For the first time, we observe an "anomalous" reduction in the threshold voltage fluctuations with an increase in the doping concentration behind the epitaxial channel, which we attribute to screening effects. Also, for the first time we study the effect of a delta-doping, positioned behind the epitaxial layer, on the intrinsic threshold voltage fluctuations. Above a certain thickness of epitaxial layer, we observe a pronounced anomalous decrease in the threshold voltage fluctuation with the increase of the delta doping. This phenomenon, which is also associated with screening, enhances the importance of the delta doping in the design of properly scaled fluctuation-resistant sub-0.1-(micron)meter MOSFET's. Index Terms-Doping, fluctuations, MOSFET, semiconductor device simulation, silicon devices, threshold.

Asenov, Asen↗

Random Dopant Induced Threshold Voltage Lowering and Fluctuations in Sub-0.1 (micron)meter MOSFET's: A 3-D 'Atomistic' Simulation Study

A three-dimensional (3-D) "atomistic" simulation study of random dopant induced threshold voltage lowering and fluctuations in sub-0.1 microns MOSFET's is presented. For the first time a systematic analysis of random dopant effects down to an individual dopant level was carried out in 3-D on a scale sufficient to provide quantitative statistical predictions. Efficient algorithms based on a single multigrid solution of the Poisson equation followed by the solution of a simplified current continuity equation are used in the simulations. The effects of various MOSFET design parameters, including the channel length and width, oxide thickness and channel doping, on the threshold voltage lowering and fluctuations are studied using typical samples of 200 atomistically different MOSFET's. The atomistic results for the threshold voltage fluctuations were compared with two analytical models based on dopant number fluctuations. Although the analytical models predict the general trends in the threshold voltage fluctuations, they fail to describe quantitatively the magnitude of the fluctuations. The distribution of the atomistically calculated threshold voltage and its correlation with the number of dopants in the channel of the MOSFET's was analyzed based on a sample of 2500 microscopically different devices. The detailed analysis shows that the threshold voltage fluctuations are determined not only by the fluctuation in the dopant number, but also in the dopant position.

Asenov, Asen↗

Threshold Assessment of Gear Diagnostic Tools on Flight and Test Rig Data

A method for defining thresholds for vibration-based algorithms that provides the minimum number of false alarms while maintaining sensitivity to gear damage was developed. This analysis focused on two vibration based gear damage detection algorithms, FM4 and MSA. This method was developed using vibration data collected during surface fatigue tests performed in a spur gearbox rig. The thresholds were defined based on damage progression during tests with damage. The thresholds false alarm rates were then evaluated on spur gear tests without damage. Next, the same thresholds were applied to flight data from an OH-58 helicopter transmission. Results showed that thresholds defined in test rigs can be used to define thresholds in flight to correctly classify the transmission operation as normal.

Dempsey, Paula J.↗

Time threshold for second positive phototropism is decreased by a preirradiation with red light

A second positive phototropic response is exhibited by a plant after the time of irradiation has exceeded a time threshold. The time threshold of dark-grown seedlings is about 15 minutes for Arabidopsis thaliana. This threshold is decreased to about 4 minutes by a 669-nanometer preirradiation. Tobacco (Nicotiana tabacum) seedlings show a similar response. The time threshold of dark-grown seedlings is about 60 minutes for tobacco, and is decreased to about 15 minutes after a preirradiation with either 450- or 669- nanometer light. The existence of a time threshold for second positive phototropism and the dependence of this threshold on the irradiation history of the seedling contribute to the complexity of the fluence response relationship for phototropism.

NASA Discipline Number 40-50↗

Measuring Input Thresholds on an Existing Board

A critical PECL (positive emitter-coupled logic) interface to Xilinx interface needed to be changed on an existing flight board. The new Xilinx input interface used a CMOS (complementary metal-oxide semiconductor) type of input, and the driver could meet its thresholds typically, but not in worst-case, according to the data sheet. The previous interface had been based on comparison with an external reference, but the CMOS input is based on comparison with an internal divider from the power supply. A way to measure what the exact input threshold was for this device for 64 inputs on a flight board was needed. The measurement technique allowed an accurate measurement of the voltage required to switch a Xilinx input from high to low for each of the 64 lines, while only probing two of them. Directly driving an external voltage was considered too risky, and tests done on any other unit could not be used to qualify the flight board. The two lines directly probed gave an absolute voltage threshold calibration, while data collected on the remaining 62 lines without probing gave relative measurements that could be used to identify any outliers. The PECL interface was forced to a long-period square wave by driving a saturated square wave into the ADC (analog to digital converter). The active pull-down circuit was turned off, causing each line to rise rapidly and fall slowly according to the input s weak pull-down circuitry. The fall time shows up as a change in the pulse width of the signal ready by the Xilinx. This change in pulse width is a function of capacitance, pulldown current, and input threshold. Capacitance was known from the different trace lengths, plus a gate input capacitance, which is the same for all inputs. The pull-down current is the same for all inputs including the two that are probed directly. The data was combined, and the Excel solver tool was used to find input thresholds for the 62 lines. This was repeated over different supply voltages and temperatures to show that the interface had voltage margin under all worst case conditions. Gate input thresholds are normally measured at the manufacturer when the device is on a chip tester. A key function of this machine was duplicated on an existing flight board with no modifications to the nets to be tested, with the exception of changes in the FPGA program.

Kuperman, Igor↗

Detection Thresholds of Falling Snow from Satellite-Borne Active and Passive Sensors

Precipitation, including rain and snow, is a critical part of the Earth's energy and hydrology cycles. In order to collect information on the complete global precipitation cycle and to understand the energy budget in terms of precipitation, uniform global estimates of both liquid and frozen precipitation must be collected. Active observations of falling snow are somewhat easier to estimate since the radar will detect the precipitation particles and one only needs to know surface temperature to determine if it is liquid rain or snow. The challenges of estimating falling snow from passive spaceborne observations still exist though progress is being made. While these challenges are still being addressed, knowledge of their impact on expected retrieval results is an important key for understanding falling snow retrieval estimations. Important information to assess falling snow retrievals includes knowing thresholds of detection for active and passive sensors, various sensor channel configurations, snow event system characteristics, snowflake particle assumptions, and surface types. For example, can a lake effect snow system with low (~2.5 km) cloud tops having an ice water content (Iwe) at the surface of 0.25 g m-3 and dendrite snowflakes be detected? If this information is known, we can focus retrieval efforts on detectable storms and concentrate advances on achievable results. Here, the focus is to determine thresholds of detection for falling snow for various snow conditions over land and lake surfaces. The analysis relies on simulated Weather Research Forecasting (WRF) simulations of falling snow cases since simulations provide all the information to determine the measurements from space and the ground truth. Results are presented for active radar at Ku, Ka, and W-band and for passive radiometer channels from 10 to 183 GHz (Skofronick-Jackson, et al. submitted to IEEE TGRS, April 2012). The notable results show: (1) the W-Band radar has detection thresholds more than an order of magnitude lower than the future GPM sensors, (2) the cloud structure macrophysics influences the thresholds of detection for passive channels, (3) the snowflake microphysics plays a large role in the detection threshold for active and passive instruments, (4) with reasonable assumptions, the passive 166 GHz channel has detection threshold values comparable to the GPM DPR Ku and Ka band radars with ~0.05 g m-3 detected at the surface, or an ~0.5-1 mm hr-l melted snow rate (equivalent to 0.5-2 cm hr-l solid fluffy snowflake rate).

Jackson, Gail↗

A Universal Threshold for the Assessment of Load and Output Residuals of Strain-Gage Balance Data

A new universal residual threshold for the detection of load and gage output residual outliers of wind tunnel strain{gage balance data was developed. The threshold works with both the Iterative and Non{Iterative Methods that are used in the aerospace testing community to analyze and process balance data. It also supports all known load and gage output formats that are traditionally used to describe balance data. The threshold's definition is based on an empirical electrical constant. First, the constant is used to construct a threshold for the assessment of gage output residuals. Then, the related threshold for the assessment of load residuals is obtained by multiplying the empirical electrical constant with the sum of the absolute values of all first partial derivatives of a given load component. The empirical constant equals 2.5 microV/V for the assessment of balance calibration or check load data residuals. A value of 0.5 microV/V is recommended for the evaluation of repeat point residuals because, by design, the calculation of these residuals removes errors that are associated with the regression analysis of the data itself. Data from a calibration of a six-component force balance is used to illustrate the application of the new threshold definitions to real{world balance calibration data.

wind tunnel balance↗

Detection Thresholds of Falling Snow From Satellite-Borne Active and Passive Sensors

There is an increased interest in detecting and estimating the amount of falling snow reaching the Earths surface in order to fully capture the global atmospheric water cycle. An initial step toward global spaceborne falling snow algorithms for current and future missions includes determining the thresholds of detection for various active and passive sensor channel configurations and falling snow events over land surfaces and lakes. In this paper, cloud resolving model simulations of lake effect and synoptic snow events were used to determine the minimum amount of snow (threshold) that could be detected by the following instruments: the W-band radar of CloudSat, Global Precipitation Measurement (GPM) Dual-Frequency Precipitation Radar (DPR)Ku- and Ka-bands, and the GPM Microwave Imager. Eleven different nonspherical snowflake shapes were used in the analysis. Notable results include the following: 1) The W-band radar has detection thresholds more than an order of magnitude lower than the future GPM radars; 2) the cloud structure macrophysics influences the thresholds of detection for passive channels (e.g., snow events with larger ice water paths and thicker clouds are easier to detect); 3) the snowflake microphysics (mainly shape and density)plays a large role in the detection threshold for active and passive instruments; 4) with reasonable assumptions, the passive 166-GHz channel has detection threshold values comparable to those of the GPM DPR Ku- and Ka-band radars with approximately 0.05 g *m(exp -3) detected at the surface, or an approximately 0.5-1.0-mm * h(exp -1) melted snow rate. This paper provides information on the light snowfall events missed by the sensors and not captured in global estimates.

remote sensing↗