Search NASA⌕ Search

SEARCH · Search NASA

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

A Non‐Intrusive Machine Learning Framework for Debiasing Long‐Time Coarse Resolution Climate Simulations and Quantifying Rare Events Statistics

Abstract Due to the rapidly changing climate, the frequency and severity of extreme weather is expected to increase over the coming decades. As fully‐resolved climate simulations remain computationally intractable, policy makers must rely on coarse‐models to quantify risk for extremes. However, coarse models suffer from inherent bias due to the ignored “sub‐grid” scales. We propose a framework to non‐intrusively debias coarse‐resolution climate predictions using neural‐network (NN) correction operators. Previous efforts have attempted to train such operators using loss functions that match statistics. However, this approach falls short with events that have longer return period than that of the training data, since the reference statistics have not converged. Here, the scope is to formulate a learning method that allows for correction of dynamics and quantification of extreme events with longer return period than the training data. The key obstacle is the chaotic nature of the underlying dynamics. To overcome this challenge, we introduce a dynamical systems approach where the correction operator is trained using reference data and a coarse model simulation nudged toward that reference. The method is demonstrated on debiasing an under‐resolved quasi‐geostrophic model and the Energy Exascale Earth System Model (E3SM). For the former, our method enables the quantification of events that have return period two orders longer than the training data. For the latter, when trained on 8 years of ERA5 data, our approach is able to correct the coarse E3SM output to closely reflect the 36‐year ERA5 statistics for all prognostic variables and significantly reduce their spatial biases.

Barthel Sorensen, B.↗

Demonstration of an AI-driven workflow for dynamic x-ray spectroscopy

X-ray absorption near edge structure (XANES) spectroscopy is a powerful technique for characterizing the chemical state and symmetry of individual elements within materials, but requires collecting data at many energy points which can be time-consuming. While adaptive sampling methods exist for efficiently collecting spectroscopic data, they often lack domain-specific knowledge about the structure of XANES spectra. Here we demonstrate a knowledge-injected Bayesian optimization approach for adaptive XANES data collection that incorporates understanding of spectral features like absorption edges and pre-edge peaks. We show this method accurately reconstructs the absorption edge of XANES spectra using only 15–20% of the measurement points typically needed for conventional sampling, while maintaining the ability to determine the x-ray energy of the sharp peak after the absorption edge with errors less than 0.03 eV, the absorption edge with errors less than 0.1 eV; and overall root-mean-square errors less than 0.005 compared to traditionally sampled spectra. Our experiments on battery materials and catalysts demonstrate the method’s effectiveness for both static and dynamic XANES measurements, improving data collection efficiency and enabling better time resolution for tracking chemical changes. This approach advances the degree of automation in XANES experiments, reducing the common errors of under- or over-sampling points near the absorption edge and enabling dynamic experiments that require high temporal resolution or limited measurement time.

Bayesian optimization↗

Using millimeter-sized carbon–deuterium foils for high-precision deuterium–tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. Additionally, while the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels are low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.

47 OTHER INSTRUMENTATION↗

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Time-stretch spectroscopy for fast infrared absorption spectra of acetylene and hydroxyl radicals during combustion

We have developed a diagnostic that uses time-domain spectroscopy to measure transient infrared absorption spectra in gases. Using a time-stretch Fourier transform approach, we can determine pressure, temperature, and gas concentrations with sub-microsecond time resolution for over two milliseconds. We demonstrate high-resolution (0.015 nm), time-resolved spectral measurements in an acetylene-oxygen gas mixture undergoing combustion. Within a 5 µs period during the reaction, the acetylene line intensities decrease substantially, and new spectra appear that are consistent with the hydroxyl (OH) radical, a common by-product in the combustion, deflagration, and detonation of fuels and explosives. Post-reaction pressures and temperatures were estimated from the OH spectra. The technique measures spectra from 1520 to 1620 nm using fiber optics, photodetectors, and digitizers. No cameras or spectrometers are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Readout Electronics of the Mu2e Electromagnetic Calorimeter

The Mu2e electromagnetic calorimeter has been designed to measure ~100 MeV electrons with energy resolution σE/E <10%, time resolution σt < 500ps and position resolution σx < 1cm. The detector is composed of 1348 un-doped CsI crystals coupled to two large area Silicon Photomultipliers (SiPMs). Each SiPM is connected to a Front End Electronics (FEE) chip which hosts the shaping amplifier and the high voltage linear regulator. A group of 20 FEE is controlled by one Mezzanine Board (MB) which transmits the amplified signals to one Digitizer ReAdout Controller board (DiRAC). The DiRAC samples the waveforms at 200 MHz with 12-bit ADCs, packs the data according to the Mu2e custom format and transmits them to the event builder through an optical transceiver. To limit the number of pass-through connectors and the length of the cables, the readout and digitization electronics is located inside the detector cryostat and close to the interaction target. The boards will have to sustain a neutron fluence of about 5x10 10 n/cm 2 @ 1 MeVeq (Si)/y and a Total Ionizing Dose of about 12 krad, while working into a 1T magnetic field and a vacuum of 10 (-4) Torr. This harsh operational environment has made the electronics design challenging and required an extended campaign of tests to select and qualify the employed electronic components. In this paper we report on the board architecture and design, on the qualification of the prototypes, as well as on the results of the first vertical slice test of the Mu2e calorimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using millimeter-sized carbon-deuterium foils for high-precision deuterium-tritium neutron spectrum measurements in direct-drive inertial confinement fusion at the OMEGA laser facility

Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA laser facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (~5 keV) and signal levels low (by ~20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils better characterized, and impact of uncontrolled foil motion prior to detection investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration and performance of large area picosecond photodetectors in the accelerator neutrino neutron interaction experiment

ANNIE, the Accelerator Neutrino Neutron Interaction Experiment, is a 26-ton Gadolinium-loaded water Cherenkov detector located at the Booster Neutrino beam line at Fermilab to mainly measure neutron multiplicity of neutrino interactions and test the performance of Large Area Picosecond Photodetectors (LAPPD). This thesis presents the integration of LAPPD at ANNIE and the preliminary performance analysis. LAPPDs achieved 2.48ns bunch structure resolution, even considering the time of flight and the intrinsic bunch width. The analysis also achieves better than 100ps intrinsic timing resolution, sub-mm position resolution for a single photoelectron, and cm-level resolution in conditional muon track reconstruction.

Feng, Yue [Iowa State U.] (ORCID:0000000332021351)↗

Ionizing photon interactions modulate the optical properties of crystals with femtosecond scale temporal resolution

In this work, we continue our study of a new method for the detection of ionizing radiation with the potential for a dramatic improvement in coincidence time resolution (CTR) for time-of-flight positron emission tomography (ToF-PET) using the modulation of a material's optical properties instead of the scintillation mechanism. Our previous work has shown that for non-scintillation materials such as bismuth silicon oxide (BSO) and cadmium telluride (CdTe), their refractive index can be modulated by annihilation photon interactions. Additionally, the ultrafast nature of this process however remains unexplored. The ionizing radiation-induced charge carriers alter the local band structure in these materials, thus changing the complex refractive index. This mechanism is routinely used at the linac coherent light source (LCLS) facility of the SLAC National Accelerator Laboratory to measure x-ray pulse arrival times with femtosecond scale resolution for photon energies between 0.5 and 10 keV. The method described here follows that example by using a frequency chirped visible continuum pulse to provide a monotonic wavelength-to-time mapping by which one can measure the time-dependent refractive index modulation. In addition, we describe an interference-based measurement setup that allows for significantly improved sensitivity while preserving a timing precision of approximately 10 fs (σ) when measuring the arrival time of below 10 keV x-ray pulses with yttrium aluminum garnet (YAG) crystal. The method is presented in the context of ToF-PET application with further discussions on the potential CTR achievable if a similar detection concept is adopted for detecting 511 keV photons. Semi-empirical analysis indicates that the predicted CTR achievable is on the order of 1 ps (FWHM).

59 BASIC BIOLOGICAL SCIENCES↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capacitively Coupled LAPPDs with 2D Pixelated Readout Planes for Time of Flight and Ring Imaging Cherenkov Applications

Large Area Picosecond Photon Detectors (LAPPDs) are micro-channel plate based photosensors featuring hundreds of square centimeters of sensitive area in a single package and capable of providing timing resolution on the order of 50 ps for single photon detection. However, LAPPDs currently do not exist in finely pixelated 2D readout configurations which, in addition to ighresolution timing, would also provide high spatial resolution required for Ring Imaging CHerenkov (RICH) detectors. One of the recent LAPPD models (Gen II) provides the opportunity to overcome the lack of pixellation by coupling an external readout to the sealed detector itself. The readout plane in this case is a simple printed circuit board (PCB) that can be laid out in a custom application-specific way for 1D or 2D sensitive area pixellation. This allows for a much shorter readout-plane prototyping cycle and provides unprecedented flexibility in choosing an appropriate segmentation that can be optimized for any particular detector need in terms of pad size, orientation, and shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of the absolute single-photon detection efficiency of HRPPD

Pixelated High Rate Picosecond Photon Detectors (HRPPDs) by Incom Inc. are promising photosensors for use in Ring Imaging CHerenkov (RICH) detectors, where a high gain, sub-mm position resolution and sub-100ps timing resolution are required in a single photon mode. Quantum Efficiency (QE) has been measured for the first batch of EIC HRPPDs both by Incom and EIC research groups at Jefferson Lab and Brookhaven Lab, with peak values at ∼365 nm typically exceeding 30%. Furthermore, in this study, we present a first direct measurement of Photon Detection Efficiency being equal to (17.1 ± 0.1 [stat] ± 0.3 [sys])% at 398.6 nm, for a pixel near the center of HRPPD, in a photoelectron pulse counting mode using a picosecond diode laser. HRPPD QE at the same spot and at the same wavelength was evaluated to be (24.4 ± 0.1 [stat] ± 0.3 [sys])%, leading to a Collection Efficiency estimate of (70.3 ± 1.6)%, which is consistent with the expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗