Search NASASearch

SEARCH · Search NASA

Results for “TRACE AMOUNTS AGE ESTIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

360 records · Page 8

Full-core high-burnup BWR LOCA fuel performance analysis and FFRD susceptibility

The susceptibility of the boiling water reactor (BWR) Limerick Unit 1 to fuel fragmentation, relocation, and dispersal during a postulated large-break loss-of-coolant accident (LBLOCA) was calculated using a multiphysics framework. The simulations include full-core, rod-resolved neutronic, thermal hydraulic, and fuel performance models using the VERA, TRACE, and BISON codes. This work focused on the transient BISON simulations, which include both the normal operation and LBLOCA periods in the same simulations. Cladding integrity was assessed using two correlations that are included with BISON. make page break Several new BWR-specific features were recently added to BISON. This work represents the first time these features have been included in a core-scale set of simulations. This study hence evaluates the performance of these new models for an operating reactor with realistic operating conditions. Simulation results showed that cladding integrity was maintained (i.e., no rods burst). Finally, future work to improve BWR and PWR predictions using this framework is suggested.

BISON

3D-Printed mmWave Quasi-Holographic Antenna for 2-D Beamforming

This paper presents the design and manufacturing of a novel 2D-scanning antenna that integrates a 3D-printed Rotman lens with a quasi-holographic leaky-wave antenna (HLWA). The proposed design achieved beam-scanning capabilities by leveraging the beamforming of the Rotman lens and the high-gain directive properties of the quasi-HLWA. The Rotman lens (RL) enables beam steering in the elevation plane by switching between input ports. The quasi-HLWA, designed using holographic principles, achieves frequency-controlled beam scanning in the azimuth plane. The entire antenna structure was fabricated using additive manufacturing with an Ink1092 substrate and silver ink for the conductive traces. This approach provides greater control over material placement and design freedom compared to traditional methods. A 25° transmission linear substrate taper was used to ensure good impedance matching between the Rotman lens and the quasi-HLWA, allowing greater gain while maintaining a good scanning range. The experimental results validate the 2D scanning capability of the proposed antenna. The antenna system provides coverage from −54° to 54° in the elevation θ plane and −28° to 28° in the azimuth plane ϕ , with a maximum measured gain of 21.3 dBi at 28 GHz with an average radiation efficiency η=60 %. The fabricated prototype was tested, and the performance was in good agreement with the simulated performance.

Rotman lens

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Exploring the Model Design Space for Battery Health Management

Battery Health Management (BHM) is a core enabling technology for the success and widespread adoption of the emerging electric vehicles of today. Although battery chemistries have been studied in detail in literature, an accurate run-time battery life prediction algorithm has eluded us. Current reliability-based techniques are insufficient to manage the use of such batteries when they are an active power source with frequently varying loads in uncertain environments. The amount of usable charge of a battery for a given discharge profile is not only dependent on the starting state-of-charge (SOC), but also other factors like battery health and the discharge or load profile imposed. This paper presents a Particle Filter (PF) based BHM framework with plug-and-play modules for battery models and uncertainty management. The batteries are modeled at three different levels of granularity with associated uncertainty distributions, encoding the basic electrochemical processes of a Lithium-polymer battery. The effects of different choices in the model design space are explored in the context of prediction performance in an electric unmanned aerial vehicle (UAV) application with emulated flight profiles.

Saha, Bhaskar

A Comparison of Doppler Lidar Wind Sensors for Earth-Orbit Global Measurement Applications

Now, there are four Doppler lidar configurations which are being promoted for the measurement of tropospheric winds: (1) the coherent CO2 Lidar, operating in the 9 micrometer region using a pulsed, atmospheric pressure CO2 gas discharge laser transmitter, and heterodyne detection; (2) the coherent Neodymium doped YAG or Glass Lidar, operating at 1.06 micrometers, using flashlamp or diode laser optical pumping of the solid state laser medium, and heterodyne detection; (3) the Neodymium doped YAG/Glass Lidar, operating at the doubled frequency (at 530 nm wavelength), again using flashlamp or diode laser pumping of the laser transmitter, and using a high resolution tandem Fabry-Perot filter and direct detection; and (4) the Raman shifted Xenon Chloride Lidar, operating at 350 nm wavelength, using a pulsed, atmospheric pressure XeCl gas discharge laser transmitter at 308 nm, Raman shifted in a high pressure hydrogen cell to 350 nm in order to avoid strong stratospheric ozone absorption, also using a high resolution tandem Fabry-Perot filter and direct detection. Comparisons of these four systems can include many factors and tradeoffs. The major portion of this comparison is devoted to efficiency. Efficiency comparisons are made by estimating the number of transmitted photons required for a single pulse wind velocity estimate of + or - 1 m/s accuracy in the middle troposphere, from an altitude of 800 km, which is assured to be reasonable for a polar orbiting platform.

Robert T Menzies

Connectivity, Pathology, and ApoE4 Interactions Predict Longitudinal Tau Spatial Progression and Memory

ABSTRACT Tau pathology spread into neocortex indicates a transition from healthy aging to Alzheimer's disease (AD). Connectivity between tau epicenters and later accumulating regions of cortex has been proposed as a mechanism of tau spread, but how this relationship changes with greater AD pathology burden or genotype is not understood. We investigated tau accumulation in two key regions, precuneus and inferior temporal cortex, using resting state functional connectivity (rsFC) and longitudinal PET imaging from a multicohort sample of cognitively unimpaired older adults. We examined how baseline tau PET, Aβ PET, and ApoE4 genotype status interact with rsFC between hippocampus and these downstream regions to predict rate of tau accumulation in neocortex. We found that the 3‐way interaction between connectivity, baseline tau, and baseline Aβ or ApoE4 status was associated with neocortical tau accumulation in precuneus and inferior temporal cortex. In addition, baseline tau, Aβ, and ApoE4 status also moderated the association between connectivity and rate of memory decline. Together, these results suggest that the extent and distribution of future tau accumulation may be predicted by the interaction of baseline connectivity, AD pathology, and genetic risk.

Neurosciences & Neurology

Polynomial-time preparation of low-temperature Gibbs states for two-dimensional toric code

In this work, we propose a polynomial-time algorithm for preparing the Gibbs state of the two-dimensional toric code Hamiltonian at any temperature, starting from any initial state, significantly improving upon prior estimates that suggested exponential scaling with inverse temperature. We prove that fast mixing at low temperature for the two-dimensional toric code can be achieved by augmenting local jump operators with simple global jump operators, which enable efficient transitions between logical sectors. To establish tight lower bounds on the spectral gap, we introduce a new reduction method that eventually maps the problem to estimating the spectral gap of a perturbed graph Laplacian on a stair graph. Our proof also shows that the Lindblad dynamics with a digitally implemented low-temperature local Davies generator is able to efficiently drive the quantum state toward the ground state manifold.

97 MATHEMATICS AND COMPUTING

Rapid Quantum Ground State Preparation via Dissipative Dynamics

Inspired by natural cooling processes, dissipation has become a promising approach for preparing low-energy states of quantum systems. However, the potential of dissipative protocols remains unclear beyond certain commuting Hamiltonians. This work provides significant analytical and numerical insights into the power of dissipation for preparing the ground state of noncommuting Hamiltonians. For quasi-free dissipative dynamics, including certain 1D spin systems with boundary dissipation, our results reveal a new connection between the mixing time in trace distance and the spectral properties of a non-Hermitian Hamiltonian, leading to an explicit and sharp bound on the mixing time that scales polynomially with system size. For more general spin systems, we develop a tensor network-based algorithm for constructing the Lindblad jump operator and for simulating the dynamics. Using this algorithm, we demonstrate numerically that dissipative ground state preparation protocols can achieve rapid mixing for certain 1D local Hamiltonians under bulk dissipation, with a mixing time that scales logarithmically with the system size. We then prove the rapid mixing result for certain weakly interacting spin and fermionic systems in arbitrary dimensions, extending recent results for high-temperature quantum Gibbs samplers to the zero-temperature regime. Together, these results show that dissipation can be a powerful tool for ground state preparation, with potential applications across condensed matter physics, quantum materials science, and beyond.

decoherence

A Phenazine‐Based Two‐Dimensional Covalent Organic Framework for Photochemical CO 2 Reduction with Increased Selectivity for Two‐Carbon Products

Abstract The reduction of carbon dioxide (CO₂) into valuable products will contribute to sustainable carbon use. Here we report the photocatalytic reduction of CO₂ to carbon monoxide, formate, and oxalate ions using a redox‐active phenazine‐based 2D covalent organic framework (Phen‐COF) and its phenazine monomer. Under similar irradiation conditions,Phen‐COFproduced 2.9 times more CO, 11 times more formate, and 13 times more oxalate compared to equimolar amounts of the monomeric phenazine, demonstrating that the COF architecture enhances catalytic performance (TOF COF : 10 −7 s −1 CO, 10 −8 s −1 formate, and 10 −11 s −1 oxalate). Structural analysis, including X‐ray diffraction and N₂ porosimetry, confirmed the COF's long‐range order and porosity. Mechanistic studies suggest a sequential formate‐to‐oxalate pathway, with CO and formate acting as intermediates. These results demonstrate the potential of the COF architecture to improve the performance of metal‐free, redox‐active aromatic systems such as phenazines to facilitate efficient and selective CO₂ conversion under mild conditions.

Chemistry

TRTR NRAD NRS Beamline Abstract

The Neutron Radiography (NRAD) Reactor is a 250kW TRIGA housed under the largest hot cell in the United States, making it the foremost location to perform neutron imaging of irradiated nuclear fuels and materials, including those intended for use with advanced reactors. Currently, NRAD has two radial beamlines that are used for neutron radiography and tomography. Upgrades to the North neutron beamline include the replacement of the in-tank beam chamber, through-the-wall collimator, and neutron shutter. These beamline upgrades will not only improve image quality for current capabilities but will also condition the beam to be more suitable for advanced methods such as neutron powder diffraction. These upgrades will increase the excess reactivity of the core, reduce unnecessary activation and exposure to workers, and significantly reduce the amount of shielding required around the beam. This presentation will describe how these upgrades improve beam quality, increase utilization of the reactor, and reduce radiation exposure to personnel.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN

Computation of three-dimensional mixed convective boundary layer flow

The paper presents the numerical solution of heat and mass transfer during cross-flow (orthogonal) mixed convection. In this class of flow, a buoyancy-driven transport in the vertical direction and a forced convective flow in the horizontal direction results in a three-dimensional boundary layer structure adjacent to the plate. The rates of heat and mass transfer are determined by a combined influence of the two transport processes. The equations for the conservation of mass, momentum, energy, and species concentration were solved along with appropriate boundary conditions to determine the distributions of velocity components, temperature, and concentration across the thickness of the boundary layer at different locations on the plate. Results were expressed in dimensionless form using Reynolds number, Richardson number for heat transfer, Richardson number for mass transfer, Prandtl number, and Schmidt number as parameters. It was found that the transport is dominated by buoyancy at smaller vertical locations and at larger distances away from the forced convection leading edge. Effects of forced convection appeared to be very strong at smaller horizontal distances from the leading edge. The cross stream forced convection enhanced the rate of heat and mass transfer by a very significant amount.

Prashandt Gadepalli

The occurrence rate of galaxies with polar structures may be significantly underestimated

Polar-ring galaxies are photometrically and kinematically decoupled systems that are highly inclined to the major axis of the host. These galaxies have been explored since the 1970s, but the rarity of these systems has made such systematic studies difficult. However, over 250 good candidates have been identified. In this work, we examine a sample of over 18 000 galaxies from the Sloan Digital Sky Survey (SDSS) Stripe 82 for the presence of galaxies with polar structures. Using deep SDSS Stripe 82, DESI Legacy Imaging Surveys, and Hyper Suprime-Cam Subaru Strategic Program, we selected 53 good candidate galaxies with photometrically decoupled polar rings, 9 galaxies with polar halos, 6 galaxies with polar bulges, and 34 possibly forming polar-ring galaxies, versus 13 polar-ring candidates previously selected in Stripe 82. Our results suggest that the occurrence rate of galaxies with polar structures may be significantly underestimated, as revealed by the deep observations, and may amount to 1–3% of non-dwarf galaxies.

Astronomy & Astrophysics

Prototype Demonstration of Solar-Carbothermal System to Extract Oxygen From Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment [1]. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Koorosh R Araghi

Prototype Demonstration of Solar Carbothermal System to Extract Oxygen from Regolith

The Carbothermal Reduction Demonstration (CaRD) project was an effort to develop a prototype system to demonstrate the extraction of oxygen from simulated lunar regolith using concentrated solar energy and a carbothermal reaction. The prototype consisted of a deployable solar concentrator capable of tracking the sun, carbothermal reactor, fluid system, gas analysis, and a solar concentrator control system consisting of avionics and software. These subsystems were developed by multiple NASA centers and a private industry partner, Sierra Space. The various teams worked together to define requirements and interfaces to successfully assemble the complex system and demonstrate an integrated solar carbothermal process. The solar concentrator developed at Glenn Research Center (GRC) was designed to be stowed for a launch environment then deployed on the lunar surface. It utilized a crossed dragone configuration of composite mirrors to direct horizontal sunlight onto a target 90° from the incoming sunlight. The key performance parameters for the solar concentrator were efficiency and power density. The carbothermal reactor was developed by Sierra Space through a separate project called the Carbothermal Oxygen Production Reactor (COPR) where it successfully demonstrated a fully automated process in a thermal vacuum environment. The fluid system needed for the carbothermal reaction was also developed by Sierra Space and successfully demonstrated in the same thermal vacuum test. The gas analysis system was developed at Kennedy Space Center (KSC) and was required to determine the amount of oxygen extracted during each test. The gas analysis system was based on the Mass Spectrometer Observing Lunar Operations (MSOLO) instrument. Avionics and software for the CaRD prototype were also developed at KSC and based on experience with MSOLO avionics and software. The control system was designed to stow, deploy, track the sun, and perform beam alignment of the concentrated light. The prototype subsystems were integrated and tested at Johnson Space Center’s (JSC) Energy Systems Test Area. A heliostat was used to direct sunlight toward the prototype in a way that is representative of the sunlight conditions at the south pole of the Moon. When concentrated sunlight was focused on simulated lunar regolith within the reactor, the gas analysis team confirmed the presence of carbon monoxide gas, which confirmed that a solar carbothermal reaction took place. The key performance parameter for the integrated prototype was grams of oxygen extracted per kilowatt hour of energy arriving at the concentrator primary mirror. The prototype design successfully demonstrated end-to-end capability and further steps to achieve a flight capable system have been defined. With lunar data, engineers would be able to design a scaled-up system capable of extracting oxygen from regolith at useful quantities for crew life support and rocket propellant. On the long term, this method of In-Situ Resource Utilization could be used to drastically reduce the cost and risk of a sustained human presence on the Moon by reducing the amount of oxygen that would have to be delivered.

Aaron Paz

Development of Electrolytes under Lean Condition in Lithium–Sulfur Batteries

Lithium–sulfur (Li–S) batteries stand out as one of the promising candidates for next-generation electrochemical energy storage technologies. A key requirement to realize high-specific-energy Li–S batteries is to implement low amount of electrolyte, often characterized by the electrolyte/sulfur (E/S) ratio. Low E/S ratio aggravates the known challenges for Li–S batteries and introduces new ones originated from the high concentration of polysulfides in limited electrolyte reservoir. Here, in this review, the connections between the fundamental properties of electrolytes and the electrochemical/chemical reactions in Li–S batteries under lean electrolyte condition are elucidated. The emphasis is on how the solvating properties of the electrolyte affect the fate of polysulfides. Built upon the mechanistic analysis, different strategies to design lean electrolytes to improve the overall process of Li–S reactions and Li anode protection are discussed.

25 ENERGY STORAGE

Quantum Filtering and Analysis of Multiplicities in Eigenvalue Spectra

Fine-grained spectral properties of quantum Hamiltonians, including both eigenvalues and their multiplicities, provide useful information for characterizing many-body quantum systems as well as for understanding phenomena such as topological order. Extracting such information with small additive error is #BQP-complete in the worst case. In this work, we introduce QFAMES (quantum filtering and analysis of multiplicities in eigenvalue spectra), a quantum algorithm that efficiently identifies clusters of closely spaced dominant eigenvalues and determines their multiplicities under physically motivated assumptions, which allows us to bypass worst-case complexity barriers. QFAMES also enables the estimation of observable expectation values within targeted energy clusters, providing a powerful tool for studying quantum phase transitions and other physical properties. We validate the effectiveness of QFAMES through numerical demonstrations, including its applications to characterizing quantum phases in the transverse-field Ising model and estimating the ground-state degeneracy of a topologically ordered phase in the two-dimensional toric code model. We also generalize QFAMES to the setting of mixed initial states. Our approach offers rigorous theoretical guarantees and significant advantages over existing subspace-based quantum spectral analysis methods, particularly in terms of the sample complexity and the ability to resolve degeneracies.

97 MATHEMATICS AND COMPUTING

Emergence of Complex Modes in Lightly Damped Structural Systems

In this short presentation format, we will provide a set of useful equations, relationships, and physical interpretations direct from the damped two-mode interaction problem. We will demonstrate that the results from the two-mode interaction problem are in direct agreement with observed test data. Practical methods for estimating the parameters driving the relations direct from modal test data are provided. We finalize with two examples demonstrating weak and strong interactions.

spaceflight hardware

Riddles About the Origin and Thermal History of the Moon

Analyses of lunar rocks have confirmed that the interior of the Moon has been subjected to magmatic differentiation, as has been determined by calculation of the thermal history of the Moon. However, it appears that differentiation occurred so early that it could not have been related to heating by long-lived radioactive elements, but rather indicates a high initial temperature of the Moon. The reasons for the high initial temperature remain unknown. The presence of a central, partially melted area revealed by seismic observations forces us to reject convective models of the Moon, while the dimensions of this area, together with the measured heat fluxes from the interior, serve as "boundary conditions" for any new calculations of the thermal history for a two-layered differentiated model of the Moon operative over the past 3.5 billion years. If we start with the early differentiation of the Moon and the high content of long-lived radioactive elements in it, explanation of its current thermal properties represents no difficulty. But these prerequisites themselves remain unexplained. Due to the continuing controversy concerning the true nature of the process of magmatic differentiation of the Moon, estimation of the composition of the entire Moon on the basis of analyses of surface rock remains unreliable, and use of these estimates to clarify the origin of the Moon is premature. Existing hypotheses concerning the origin of the Moon encounter dynamic difficulties, as well as difficulties with explanation of the high initial temperature, to say nothing of the difficulty involved in explaining the proposed differences in the composition of the Earth and Moon.

B Yu Levin