Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Experimental Quantification of Spin–Phonon Coupling in Molecular Qubits Using Inelastic Neutron Scattering

Electronic spin superposition states enable nanoscale sensing through their sensitivity to the local environment, yet their sensitivity to vibrational motion also limits their coherence times. In molecular spin systems, chemical tunability and atomicscale resolution are accompanied by a dense, thermally accessible phonon spectrum that introduces efficient spin relaxation pathways. Despite extensive theoretical work, there is little experimental consensus on which vibrational energies dominate spin relaxation or how molecular structure controls spin−phonon coupling (SPC). We present a fully experimental method to quantify SPC coefficients by combining temperature-dependent vibrational spectra from inelastic neutron scattering with spin relaxation rates measured by electron paramagnetic resonance. We apply this framework to two model S = 1/2 systems, copper(II) phthalocyanine (CuPc) and copper(II) octaethylporphyrin (CuOEP). Two distinct relaxation regimes emerge: below 40 K, weakly coupled lattice modes below 50 cm −1 dominate, whereas above 40 K, optical phonons above ∼185 cm −1 become thermally populated and drive relaxation with SPC coefficients nearly 3 orders of magnitude larger. Structural distortions in CuOEP that break planar symmetry soften the crystal lattice and enhance anharmonic scattering but also raise the energy of stretching modes at the molecular core where the spins reside. This redistributes vibrational energy toward the molecular periphery and out of plane, ultimately reducing SPC relative to CuPc and enabling room-temperature spin coherence in CuOEP. Although our method does not provide mode-specific SPC coefficients, it quantifies contributions from distinct spectral regions and establishes a broadly applicable, fully experimental link between crystal structure, lattice dynamics, and spin relaxation.

Lohaus, Stefan H. [California Institute of Technol↗

ROADRUNNER uranium nitride MiniFuel: Experimental design, fabrication and pre-irradiation baseline characterization for accelerated burnup testing

Uranium nitride (UN) is a promising fuel candidate for advanced reactor systems owing to its high uranium density and thermal conductivity; however, its qualification remains constrained by the scarcity of well-controlled irradiation performance data. Here, to address this limitation, the ROADRUNNER (Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments) campaign employs the MiniFuel platform in the High Flux Isotope Reactor (HFIR) to enable accelerated burnup irradiation testing under tightly controlled and largely isothermal conditions. This paper presents the experimental design, fuel fabrication, and pre-irradiation baseline characterization of the ROADRUNNER UN MiniFuel campaign. Thirty-six UN minidisc specimens were fabricated with systematically varied as-fabricated density (86–96% of theoretical density), carbon impurity content (961–5240 ppm), oxygen content (≤ ∼2000 ppm), and grain size (2.5–24 μm). The irradiation matrix spans nominal fuel temperatures of 873 K, 1173 K, and 1473 K and target burnups of 3.75%, 6.0%, and 7.5% fissions per initial metal atom (FIMA). Neutronic and thermal analyses were performed to define specimen-specific burnup accumulation and temperature histories, establishing the boundary conditions for subsequent in-pile behavior. Comprehensive pre-irradiation characterization—including dimensional metrology, density verification, impurity analysis, X-ray diffraction, Raman spectroscopy, scanning electron microscopy, X-ray computed tomography, and confocal profilometry—provides a detailed baseline for post-irradiation examination. Pre-irradiation data were further used to generate predictive estimates of fission gas release and swelling using existing empirical correlations. This quantitative comparison reveals substantial inter-model divergence at intermediate and elevated temperatures that exceeds propagated input uncertainties, highlighting structural gaps in the historical irradiation database. The ROADRUNNER irradiation campaign is currently underway in HFIR, with initial firs cycle completed in late 2025 and remaining targets scheduled through 2027. The experimental design and baseline dataset presented here establish the framework needed to interpret forthcoming post-irradiation measurements and to provide discriminating data for the validation and refinement of physics-based UN fuel performance models.

Lopes, Denise Adorno [Oak Ridge National Laborator↗

Early-stage Testing of Thermal Power Dispatch Simulator for Subjective Mental Workload and Evolution Time

The excess thermal energy produced by nuclear power plants (NPPs) during low electricity demands can be utilized in industrial processes, such as hydrogen production, through a thermal power dispatch (TPD) system. Initial testing of the first iteration of a single-train TPD design with a manual control mode at the Idaho National Lab (INL) revealed a high operator workload and degraded control capability. The current study evaluated the impact of an enhanced dual-train TPD design on operators’ subjective mental workload and evolution task-time while completing two operating scenarios in manual and automatic control modes. The results showed no statistically significant difference between participants’ mental workload using both control modes. Evolution time in automatic control mode took a shorter time than in manual control, with participants completing all evolutions in less than the 10-min set as the design specification limit. The shorter evolution time is discussed within the context of plant safety and operational efficiency.

Gideon, Olugbenga↗

NMPC for Mode-Switching Operation of Reversible Solid Oxide Cell Systems

Solid oxide cells (SOCs) are a promising dual-mode technology that generates hydrogen through high-temperature water electrolysis and generates power through a fuel cell reaction that consumes hydrogen. Reversible operation of SOCs requires a transition between these two modes for hydrogen production setpoints as the demand and price of electricity fluctuate. Moreover, a well-functioning control system is important to avoid cell degradation during mode-switching operation. In this work, we apply nonlinear model predictive control (NMPC) to an SOC module and supporting equipment and compare NMPC performance to classical proportional integral (PI) control strategies, while ramping between the modes of hydrogen and power production. While both control methods provide similar performance in many metrics, NMPC significantly reduces cell thermal gradients and curvatures (mixed spatial-temporal partial derivatives) during mode switching. A dynamic process flowsheet of the reversible SOC system was developed in the open-source, equation-based IDAES modeling framework. Our IDAES dynamic simulation results show that NMPC can ramp the SOC system between hydrogen and power production targets within short mode-switching times. Moreover, NMPC can comply with operating limits in the SOC system more effectively than PI, and only NMPC can directly enforce user-specified limits for mixed spatial-temporal partial derivatives of temperature. This allows for management of the trade-off be-tween operating efficiency and cell degradation, which is dependent on these temperature curvatures.

Li, Mingrui↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Quantum computing universal thermalization dynamics in a (2 + 1)D Lattice Gauge Theory

Simulating non-equilibrium phenomena in strongly-interacting quantum many-body systems, including thermalization, is a promising application of near-term and future quantum computation. By performing experiments on a digital quantum computer consisting of fully-connected optically-controlled trapped ions, we study the role of entanglement in the thermalization dynamics of a Z 2 lattice gauge theory in 2+1 spacetime dimensions. Using randomized-measurement protocols, we efficiently learn a classical approximation of non-equilibrium states that yields the gap-ratio distribution and the spectral form factor of the entanglement Hamiltonian. These observables exhibit universal early-time signals for quantum chaos, a prerequisite for thermalization. Our work, therefore, establishes quantum computers as robust tools for studying universal features of thermalization in complex many-body systems, including in gauge theories.

97 MATHEMATICS AND COMPUTING↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Thermally anisotropic composites for thermal management in building environments

An improved system for thermal management is provided. The system includes thermally anisotropic composites coupled with a thermal loop to re-direct, reduce, and shape heat flows through a building envelope, having the potential to (1) significantly reduce envelope-generated heating and cooling loads and (2) provide grid services such as decreasing peak loads and shaping energy use. In one embodiment, the thermal management system includes an anisotropic composite that consists of alternating layers of thermal insulation and thermally conductive materials that are immediately adjacent to each other, including polyisocyanurate foam boards and aluminum sheets. The thermal management system also includes a thermal loop along the long edge or the entire the perimeter of the anisotropic composite, the thermal loop having dynamically controlled or floating temperature that is maintained at lower than an outdoor ambient temperature (for cooling). An interior wall structure is inwardly adjacent to the anisotropic composite.

Shrestha, Som S.↗

Fast, Controllable, and Modular Solid-State Circuit Breaker Design for Battery Management Systems

Electric power grid is experiencing a growing number of distributed and inertia-free generation resources. To facilitate the growing generation and load demands, and ensure stable operation, energy storage systems, especially behind-themeter-storage (BTMS), have emerged as a potential candidate. BTMS plays a vital role in the grid storage sector and supports high power charging for EVs. However, the potential of thermal runaway and associated safety concerns in the batteries can hamper their widespread adoption. In this work, we provide a solution for a fast and controllable discharge of a cell that was identified as a stressful/faulty, in the battery pack, and fast circuit breaking leveraging the Solid-State Circuit Breaker (SSCB) technology which provides active control over the cell connection as opposed to conventional passive solutions. Testing on the simulation platform successfully validated the concept, demonstrating its efficacy. Controlled discharge testing with 20Ah LiFePO4 Lithium Iron Phosphate (LFP) cells from 1C-10C current rate on the hardware prototype corroborated simulation results, demonstrating design feasibility and providing essential data for its performance and thermal characteristics, while also revealing limitations that inform areas for further optimization.

33 ADVANCED PROPULSION SYSTEMS↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Additive manufacturing for electrocaloric terpolymer thin films

Current heating, venting, and air conditioning (HVAC) systems have drawbacks of high energy consumption, large CO 2 emissions, and low efficiency. Electrocaloric (EC) cycles present an eco-friendly alternative by converting thermal energy to electrical energy. Defect-free thin films with uniform thickness are required to achieve optimal EC performance. A scalable thin film fabrication process is essential for integrating EC cycles into HVAC systems. This study introduces EC thin films prepared by electrospray (ES) processing, a manufacturing method that deposits EC polymer layer by layer using high voltage. The resulting films show superior thickness control, smoother surfaces, and improved thermal and electrical properties compared with solution casting. In addition, post-annealing at 120°C enhances the thermal and EC performance, with films achieving a temperature change (ΔT) of 3.6°C at 100 MV/m when tested near room temperature. With the potential for future scalability, the ES method offers a promising approach for fabricating EC thin films.

36 MATERIALS SCIENCE↗

Equipment List Comparing Balance of Plant Containing a Heat Pump against a Reference Electricity Generating Plant

Approximately two-thirds of U.S. energy consumption in the industrial and transportation sectors relies on fossil fuels. These sectors require high-quality heat, i.e., thermal energy at very high temperatures, for molecular transformation processes. The Integrated Energy Systems (IES) program aims to assess the economic potential of utilizing nuclear-grade heat from Advanced Reactors (ARs) to meet the high-quality heat demands. By having industrial processes (IPs) supplied with nuclear-generated heat, manufacturers could benefit from more stable and potentially lower energy costs, reducing reliance on volatile fossil fuel markets. The main outcome of the FY24 research was the thermodynamic assessment and gap analysis of steam generation for IP applications. The study completed in June 2024 demonstrated that the required steam temperatures could be achieved by integrating a heat pump into an AR power plant. After identifying the thermal demands of target IPs, multiple balance of plant configurations for the Xe-100 reactor by X-energy, incorporating a heat pump, were analyzed. Their technical feasibilities were assessed, including the design of suitable axial compressors for these applications. Comparative performance analysis showed that thermal efficiency alone is insufficient to evaluate system suitability. To address this, a new indicator (heat factor) was introduced in the report released in September 2024 to quantify the low-quality thermal power needed to produce one unit of high-quality heat for the IP. Results showed that integrating heat pumps into Rankine cycles enables higher steam temperatures, though at the expense of increased thermal energy input. This report builds upon and completes the foundational work previously undertaken. It focuses on the design of two Balance of Plant (BOP) configurations, both based on Rankine energy conversion cycles: “Case 1”, which involves electricity generation only, and “Case 2”, which combines electricity and high-temperature heat generation for industrial use. For each configuration, a comprehensive equipment list was developed, detailing all major components such as turbines, compressors, heat exchangers, pumps, and control systems. These lists will serve as the basis for future comparative cost analyses, with the goal of assessing the number and type of components required to integrate a heat pump into the Rankine cycle and to establish a heat transport system capable of delivering thermal energy from the nuclear plant to an industrial facility. Using the constitutive equations presented in the June 2024 milestone, the operating conditions of all BOP components for both “Case 1” and “Case 2” were evaluated. These parameters—such as temperature, pressure, mass flow rate, and steam quality—served as the basis for calculating the associated thermal and mechanical power flows. The net power required from the heat pump to raise the steam temperature to the target level was also determined. The thermodynamic performance of the configuration was then assessed using the heat factor metric. The key outcome of this analysis is a comparative table that presents the equipment that was used in the “Case 1” and “Case 2” configurations. This study offers a preliminary comparison of the two designs, providing insight into the impact of integrating a heat pump in terms of component requirements and thermal efficiency. This equipment list, together with the evaluated operating conditions, also serves as a foundation for the economic analyses scheduled for the current fiscal year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Thermo-hydro-mechanical analysis of subsurface ice-based thermal energy storage

Ice-based thermal energy storage systems are widely utilized for cooling and managing peak electrical demand globally, offering daily or weekly storage capabilities for both individual homes and larger office buildings. However, scaling these systems for district-level cooling or integrating them with renewable energy sources presents challenges, especially in accommodating larger volumes and addressing seasonal storage requirements in densely populated urban areas. This paper proposes a novel solution by evaluating subsurface ice-based thermal energy storage, in which the underground is subjected to seasonal freeze/thaw cycles. However, these cycles may influence ground behavior, affecting pore pressure and inducing ground movement. To systematically investigate these challenges, we enhance the TOUGH-FLAC simulator by integrating water/ice phase change capabilities and updating the effective stress–strain constitutive relation. Both modifications are validated against analytical solutions or experimental data. Through numerical simulations spanning a decade with ten seasonal freeze/thaw cycles, we evaluate the performance and long-term stability of a generic subsurface ice-based thermal energy storage system, considering factors such as ground permeability, freezing pipe spacing, freeze/thaw damage, and glycol solution temperature. The simulations indicate that ice formation induces pore pressure variations that drive seasonal surface heave and settlement, controlled by ground permeability, pipe spacing, and glycol solution temperature, along with tensile and localized shear deformation around freeze pipes. This highlights the need for accurate ground property characterization and geomechanical analysis for subsurface ice-based thermal energy storage.

Ground freezing↗

Ice storage model-predictive control in an office building with PV: scenario, error and sensitivity analysis

Thermal energy storage (TES) can enable more building-sited renewable electricity generation and lower utility bill costs for buildings owners and occupants, especially when there are high demand and variable time-of-use (TOU) charges. A model predictive control (MPC) strategy can offer additional savings over a schedule-based control with added complexity and reliance on forecasts. Here, this study examines savings for medium office buildings with chiller plants in three locations with building-installed solar photovoltaics (PV) to understand the impact of MPC. Control setpoints are fixed by a schedule-based control or optimized by nonlinear MPC. These control setpoints are actuated within EnergyPlus building models to simulate the utility cost of the chiller plant. NLP solutions can be unstable or unrealistic, but our results show that by regularizing the NLP, the solutions can be reasonably followed by the building model. MPC models make simplifications that lead to errors once the controller is participating in and changing the operation of the building. These errors average 9 % across the cases, showing that the most important parts of the system are represented. The no-thermal load costs are computed to show that the optimization can in some cases achieve both the minimum TOU and minimum monthly demand costs by demand management while reducing TOU energy costs by energy arbitrage. The MPC saves 35–66 % in the annual chiller plant operating costs, which is an additional savings above the schedule by 1–33 %. PV and TES are complementary and mostly independent, but a load with PV often results in better performance for the schedule. Our case study and sensitivity analysis show the importance of modeling and optimization for complex rates, but also the circumstances wherein a simpler strategy achieves the same performance with less potential for error.

14 SOLAR ENERGY↗

Design of a SMART Valve Testbed for Nuclear Thermal Dispatch

By the year 2050, the United States aims to achieve net-zero carbon emissions. To achieve this target, the licensing of the Light Water Reactor (LWR) fleet has been extended for 20 more years. To stay economically competitive with other power sources such as renewable and fossil-fuel power plants, the U.S. Department of Energy has introduced a plan to modernize the existing LWR fleet and diversify the revenue stream. One of the plans is to dispatch thermal energy to endothermic industrial processes. SMART valves will play an important role in this initiative by efficiently balancing the load by regulating valves in a coordinated manner while monitoring the thermal-hydraulic systems to enhance safety and maintain the integrity of the power plant. This research aims to develop a facility to test the coordinated control algorithm and produce various test results for training the monitoring system. The constructed facility is capable of simulating various operational and accidental scenarios by coordinating all the valves (positions) and pump (flowrate). The facility is developed with an Internet of Things (IoT)-based custom system and a python-based valve position control and coordination mechanism. It has achieved stable sensor outputs, pump control, and coordinated valve regulation in all three valves with minimum obstruction in the system.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗