Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thermal Energy Distribution System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Martian thermal boundary layers: Subhourly variations induced by radiative-conductive heat transfer within the dust-laden atmosphere-ground system

Radiative-conductive heat transfer has been investigated for the ground-atmosphere system of the planet Mars. The basic goal was the quantitative determination of time dependent vertical distributions of temperature and static stability for Southern-Hemispheric summer season and middle and polar latitudes, for both dust-free and dust-laden atmospheric conditions. The numerical algorithm which models at high spatial and temporal resolution the thermal energy transports in the dual ground-atmosphere system, is based on solution of the applicable heating rate equation, including radiative and molecular-conductive heat transport terms. The two subsystems are coupled by an internal thermal boundary condition applied at the ground-atmosphere interface level. Initial data and input parameters are based on Mariner 4, 6, 7, and 9 measurements and the JPL Mars Scientific Model. Numerical experiments were run for dust-free and dust-laden conditions in the midlatitudes, as well as ice-free and ice-covered polar regions. Representative results and their interpretation are presented. Finally, the theoretical framework of the generalized problem with nonconservative Mie scattering and explicit thermal-convective heat transfer is formulated, and applicable solution algorithms are outlined.

Pallmann, A. J.↗

Solar thermal power systems point-focusing distributed receiver technology project. Volume 2: Detailed report

The accomplishments of the Point-Focusing Distributed Receiver Technology Project during fiscal year 1979 are detailed. Present studies involve designs of modular units that collect and concentrate solar energy via highly reflective, parabolic-shaped dishes. The concentrated energy is then converted to heat in a working fluid, such as hot gas. In modules designed to produce heat for industrial applications, a flexible line conveys the heated fluid from the module to a heat transfer network. In modules designed to produce electricity the fluid carries the heat directly to an engine in a power conversion unit located at the focus of the concentrator. The engine is mechanically linked to an electric generator. A Brayton-cycle engine is currently being developed as the most promising electrical energy converter to meet near-future needs.

Source record↗

Storage Futures Study: Storage Technology Modeling Input Data Report

The Storage Futures Study (SFS) is a multiyear research project to explore the role and impact of energy storage in the evolving electricity sector of the United States. The SFS is designed to examine the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. This specific report synthesizes current and projected cost performance assumptions along with location availability for storage technologies through 2050 that will be used in scenario analysis for the SFS at both the bulk power and distribution system scales. For comparison and context, this report also presents a synthesis of current cost and performance characteristics of energy storage technologies for storage durations ranging from minutes to months and including mechanical, thermal, and electrochemical storage technologies for the electricity sector. This information is intended to cover a broad range of storage technologies that are currently receiving significant attention from the investment community as well as in the media. In the report, we emphasize that energy storage technologies must be described in terms of both their power (kilowatts [kW]) capacity and energy (kilowatt-hours [kWh]) capacity to assess their costs and potential use cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution of Neutrons in a Cold Lucite Moderator

A series of experiments was performed in 2010 to study the behavior of neutrons in a cold Lucite moderator. The diffusion of neutrons in a cold moderator is described as a two-step process. In the first step, the fast neutrons produced by a neutron source collide with the nuclei of Lucite, losing energy until they reach thermal energies. In the second step, the thermal neutrons continue to diffuse without any significant loss of energy until they are absorbed or leak out of the system. However, because the Lucite moderator is at low temperature, there is less up scattering in the neutron energy compared to a Lucite moderator at room temperature. Experiments were performed to study the behavior of neutrons and their distribution in a cold Lucite moderator and their results compared to simulations. Based on these measurements, an estimation of the absorption cross section at -78.5 °C yielded a value of 0.54 barns ± 0.02 barns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A System Approach to Deep Heating Savings Through Measurement, Management, and Motivation

Across multi-tenant commercial office and multifamily buildings, centrally metered fuel use represents a substantial fraction of whole-building energy use. Energy audit practitioners understand that improving heating distribution efficiency is typically more of an opportunity than combustion efficiency and that differing thermal comfort preferences between tenants are the bane of operators across these building typologies. There is an unmet market need for retrofit technologies that allow for the delivery of the right amount of heat to the right spaces, at the right time. The Energy Management and Information System (EMIS) package fills this gap through enhanced controls and metering, incorporating low-cost sensors and wireless communication infrastructure to provide a platform for ongoing commissioning and tenant feedback, including heat cost allocation. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Sentient Buildings, E Source, building owners, and utility and policy stakeholders, to demonstrate a market viable EMIS that achieves a reduction in space heating energy use by reducing heating load, improving control, and positively impacting behavior while providing an acceptable financial return. In this study, EMIS packages were implemented in two New York City multifamily rental buildings. Both buildings conducted basic mechanical work (e.g., repairing steam traps) to ensure the heating system was operating well before any tenant feedback was layered in. Heating Energy Use Reports (HEUR) were created to provide tenants with social comparisons and energy savings tips to influence their behavior; these were provided monthly to all tenants in both buildings. Additionally, one building allocated heating costs to a portion of the tenants. Heat cost allocation (HCA) has a long history in the European Union (EU), although it is not common in the US or in steam-heated buildings. SWA leveraged existing EU best practices and stakeholder feedback to develop a Heat Cost Allocation algorithm that was considered equitable and intuitive. Energy use and tenant behavior impacts were tracked throughout the study. The basic mechanical repair work saved between 11-20% of heating energy. Those savings rose to 17-24% with the addition of tenant feedback. While it may not be possible to precisely determine the impact of COVID-19 on research studies like this, there may have been additional savings realized had the study taken place in a period of normal occupancy patterns. These types of central heating systems have been a blind spot for utilities, who have traditionally had little visibility into detailed behind-the-meter gas usage. Heating energy savings stayed consistent during the coldest months, indicating the potential for utilities to utilize EMIS packages for peak gas demand reductions or demand response programs. Tenant comfort was also improved. Post installation, room temperatures more closely matched thermostat set points. Perhaps due to this greater level of control, the vast majority of tenants being billed for heating were accepting of the allocation costs. And tenants receiving heat cost allocations were more likely to reduce their thermostat setpoints than tenants receiving behavioral feedback without financial impacts were. Variation in building specifics makes it difficult to provide precise energy and financial savings estimates. But within the range of expected conditions, the study identified a few key variables that can have the greatest impact on financial returns: the cost of fuel, the ability and willingness to allocate heating costs to tenants, and a well-functioning heating system as a starting point. This study focused on two multifamily buildings, but additional use cases, such as commercial buildings and affordable housing, should be explored to better understand the full market potential. While this type of upgrade has the potential for deep energy reductions and cost savings, future projects should take into account the balance of costs and benefits between owners and tenants, especially in the affordable, regulated, or other low-to-moderate income (LMI) segments of the market. Rent credits, utility allowances, or a shared savings program are possible options to accelerate adoption of this strategy in these market segments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermalization of nuclear matter in heavy-ion collisions at Fermi energies

We analyze the time evolution of the kinetic properties of nuclear matter produced in heavy-ion collisions at Fermi energies. The collision system is simulated using Constrained Molecular Dynamics (CoMD) transport calculations whose output is the isospin, position, and momentum of the nucleons. Focusing on central 35 A·MeV 40 Ca+ 40 Ca collisions we utilize this information to extract localized momentum distributions in volume elements of 8 fm 3 and time steps of 5 fm/$c$. We then parameterize the single-particle momentum distributions with thermally motivated fit functions in the local rest frame of each cell. While the transverse-momentum distributions are well reproduced by thermal ones, the longitudinal ones carry a marked imprint of the initial nuclear motion which we capture by introducing a centroid motion into our fit functions. In particular, we find that Fermi distributions yield significantly better fits than Boltzmann ones, a consequence of the Pauli blocking implemented in CoMD. From the fits we extract the time dependence of the thermodynamic and collective properties of the excited nuclear medium. We find that the transverse temperature gradually rises to about 6 MeV, which is accompanied by a dissipation of the initial centroid motion of the incoming nuclei which vanishes at about 100 fm/c after initial impact. In conclusion, we are therefore able to track the transition of beam energy into random kinetic energy for nucleons, suggesting a three-dimensional equilibration of energy in the late stages of the collision.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar thermal parabolic dish energy applications

Vu-graphs are presented that show that applications are a viable distributed renewable power generation option. Quality energy can be produced in the form of electricity and high temperature heat. Modular systems are described that can be distributed to new or existing plants and that are mass producible with the associated economies of production.

Pijawka, W.↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

Predicting mesoscale spectral thermal conductivity using advanced deterministic phonon transport techniques

We present a review, demonstration and simulation of phonon transport for the purposes of predicting materials performance at the mesoscale. We focus primarily on the development and implementation of a unified methodology to enable predictive heat transport. We report on the current state of the art as it pertains to deterministic phonon transport methodologies, discussing various topics concerning phonons. In application, we focus on the Self-Adjoint Angular Flux (SAAF) formulation of the Boltzmann transport equation for phonons, and develop the spatial, angular, and material property discretization required to accurately simulate the predictive physics of heat transport in dielectrics. We discuss thermal interfacial resistance and present our formulation of the diffuse mismatch model for simulating phonon interactions at internal boundaries. We have recently developed a deterministic, spectral phonon transport method for predicting effective thermal conductivity ($\kappa_{\textrm{eff}}$), using Bose-Einstein source terms coupled through an average material temperature. In this method, we introduce a closure term to the phonon transport system which acts as a redistribution function for the total energy of the system, and serves as a guide for the amount of non-equilibrium behavior occurring in the system. This method predicts thermal conductivity and equilibrium temperature distributions in homogeneous and heterogeneous materials using data generated by ab initio density functional theory methods. We employ polarization, density of states and full dispersion spectra to resolve thermal conductivity with numerous angular and spatial discretizations. Our implementation utilizes a Richardson iteration on a modified version of the phonon scattering source. The equations associated with this method are solved via a modification of traditional source iteration. We compare the performance of source iteration applied to an existing uncoupled, traditional SAAF method to our new method and comment on the iterative performance of each. We observe ballistic and diffusive phonon scattering as acoustic thickness of the domain changes, and are able to make comparisons between the accuracy and efficiency of both methods.

36 MATERIALS SCIENCE↗

Comparative performance of solar thermal power generation concepts

A performance comparison is made between the central receiver system (power tower) and a distributed system using either dishes or troughs and lines to transport fluids to the power station. These systems were analyzed at a rated capacity of 30 MW of thermal energy delivered in the form of superheated steam at 538 C (1000 F) and 68 atm (1000 psia), using consistent weather data, collector surface waviness, pointing error, and electric conversion efficiency. The comparisons include technical considerations for component requirements, land utilization, and annual thermal energy collection rates. The relative merits of different representative systems are dependent upon the overall conversion as expressed in the form of performance factors in this paper. These factors are essentially indices of the relative performance effectiveness for different concepts based upon unit collector area. These performance factors enable further economic tradeoff studies of systems to be made by comparing them with projected production costs for these systems.

Wen, L.↗

Energy conservation, using remote thermal scanning

Airborne thermal infrared scans and thermal maps utilized in NASA's energy conservation program have proven to be efficient cost-effective method for identifying heat losses from building roofs and heating system distribution lines. Method employs commercially available equipment in highly developed way.

Bowman, R. L.↗

Modeling District Heating and Cooling Systems with URBANopt, GeoJSON to Modelica Translator, and the Modelica Buildings Library

The URBANopt project has successfully leveraged OpenStudio/EnergyPlus to model buildings and electrical systems at an urban scale; however, URBANopt has lacked the ability to model district thermal energy systems until recently. This paper will present the modeling infrastructure that was developed specifically for the analysis of district heating and cooling systems, and how it is integrated into the existing URBANopt framework. The paper also discusses the development of new models added to the Modelica Buildings Library to model various district energy system components including loads, energy transfer stations (ETS), distribution networks, and central plants. The paper describes how different building loads can be modeled including time series, TEASER reduced-order models, or Spawn of EnergyPlus models. URBANopt District Energy Systems allows the user to switch between the various configurations.

district heating and cooling↗

Characterization and thermometry of dissipatively stabilized steady states

In this work we study the properties of dissipatively stabilized steady states of noisy quantum algorithms, exploring the extent to which they can be well approximated as thermal distributions, and proposing methods to extract the effective temperature T. We study an algorithm called the relaxational quantum eigensolver (RQE), which is one of a family of algorithms that attempt to find ground states and balance error in noisy quantum devices. In RQE, we weakly couple a second register of auxiliary ‘shadow’ qubits to the primary system in Trotterized evolution, thus engineering an approximate zero-temperature bath by periodically resetting the auxiliary qubits during the algorithm’s runtime. Balancing the infinite temperature bath of random gate error, RQE returns states with an average energy equal to a constant fraction of the ground state. We probe the steady states of this algorithm for a range of base error rates, using several methods for estimating both T and deviations from thermal behavior. In particular, we both confirm that the steady states of these systems are often well-approximated by thermal distributions, and show that the same resources used for cooling can be adopted for thermometry, yielding a fairly reliable measure of the temperature. These methods could be readily implemented in near-term quantum hardware, and for stabilizing and probing Hamiltonians where simulating approximate thermal states is hard for classical computers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress in Fast Modular Reactor Conceptual Design

The Fast Modular Reactor (FMR) is a 100-MW(thermal) gas-cooled fast reactor being developed by General Atomics Electromagnetic System with the goal of developing a FMR for flexible and dispatchable power to the U.S. electricity market in the mid-2030s. The conceptual design aims to develop and verify simplified design features. These include an inert helium gas coolant, pellet-loaded fuel rods, installations with air cooling as ultimate heat sink, and small and passive heat removal systems. The goal is to ensure the development of a safe, maintainable, cost-effective, and distributed nuclear energy-generating station. The baseline technologies selected to achieve this goal are a helium coolant that is an inert gas with no chemical reaction with structural components, not activated, single phase, enabling high-temperature operation and a high thermal efficiency Brayton cycle; conventional uranium dioxide (UO 2 ) fuel, which is the most widely used and well-known fuel material, capable of high burnup (100 MWd/kg) and a long fuel life; and silicon carbide composite (SiGA®) cladding and internal structures that are chemically inert in the helium environment, exceptionally radiation tolerant, and being derisked by accident tolerant fuel technology development. Further, the reactor was specifically designed with passive safety features, including high-temperature in-core materials and a reactor vessel cooling system consisting of cooling panels of naturally circulating water. The passive safety of the core was confirmed for the depressurized loss-of–forced cooling accident, which showed the peak cladding temperature at ~1600°C during the transient, which is below the current design limit of 1800°C. The conceptual design of the FMR has been conducted for the reactor system, vessel system, generator and turbomachine, instrumentation and control, residual heat removal system, plant service system, and containment, as well as pre-application licensing documents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks

Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.

33 ADVANCED PROPULSION SYSTEMS↗

Hot electrons between cold walls

We consider electron cooling in a collisionless plasma slab between two cold and freely emitting walls. Numerical calculations suggest a counterintuitive behavior of this system: the cooling rate slows down and eventually stops, leaving the system with a significant fraction of its initial thermal energy. Analytical treatment within the Vlasov–Poisson model reveals a set of steady-states with a two-component distribution of electrons: the primary electrons trapped within the potential wells and the secondary electrons forming the counterstreaming beams. We show that such steady-states are linearly stable with respect to one-dimensional perturbations. Establishment of a particular steady-state depends on initial conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗