Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transformation of a ceramic precursor to a biomedical (metallic) alloy: Part I – sinterability of Ta 2 O 5 and TiO 2 mixed oxides

Mixed Ta 2 O 5 – TiO 2 binary system was studied by a combination of differential thermal analysis (DTA), scanning electron microscopy-energy dispersive spectrometry (SEM-EDS), X-ray diffraction (XRD) and in situ high temperature X-ray diffraction (HT-XRD) techniques. Different compositions of the mixed oxide powders were fabricated by ball–milling the powdered compositions, pelletizing the homogenized composite powders, and heating the green pellets in air at different temperatures for fixed time intervals. The sintered pellets were evaluated and characterized with respect to porosity, morphology, and phase distribution. DTA runs of the un-sintered powders indicated the onset temperatures for both exothermic and endothermic changes in the binary system. Significant amount of sintering was observed to take place at temperatures higher than 900 °C. Both room and high temperature X-ray diffraction patterns exhibited consistency in phase formation. A ternary compound (TaTiO 4 ) and a ternary solid solution (Ti 0.33 Ta 0.67 O 2 ) were observed to form in both room and high temperatures in addition to the respective binary phases (Ta 2 O 5 and TiO 2 ). A sintering temperature in the range 900–1000 °C was observed to be adequate to achieve the requisite mechanical strength and optimum internal porosity (40–48%) for subsequent electrochemical polarization experiments.

36 MATERIALS SCIENCE↗

Avalanches and many-body resonances in many-body localized systems

Here we numerically study both the avalanche instability and many-body resonances in strongly disordered spin chains exhibiting many-body localization (MBL). Finite-size systems behave like MBL within the MBL regimes, which we divide into the asymptotic MBL phase and the finite-size MBL regime; the latter regime is, however, thermal in the limit of large systems and long times. In both Floquet and Hamiltonian models, we identify some landmarks within the MBL regimes. Our first landmark is an estimate of where the MBL phase becomes unstable to avalanches, obtained by measuring the slowest relaxation rate of a finite chain coupled to an infinite bath at one end. Our estimates indicate that the actual MBL-to-thermal phase transition occurs much deeper in the MBL regimes than has been suggested by most previous studies. Our other landmarks involve systemwide many-body resonances: We find that the effective matrix elements producing eigenstates with systemwide many-body resonances are enormously broadly distributed. This broad distribution means that the onset of such resonances in typical samples occurs quite deep in the MBL regimes, and the first such resonances typically involve rare pairs of eigenstates that are farther apart in energy than the minimum gap. Thus we find that the resonance properties define two landmarks that divide the MBL regimes of finite-size systems into three subregimes: (i) at strongest randomness, typical samples do not have any eigenstates that are involved in systemwide many-body resonances; (ii) there is a substantial intermediate subregime where typical samples do have such resonances but the pair of eigenstates with the minimum spectral gap does not, so the size of the minimum gap agrees with expectations from Poisson statistics; and (iii) in the weaker randomness subregime, the minimum gap is larger than predicted by Poisson level statistics because it is involved in a many-body resonance and thus subject to level repulsion. Nevertheless, even in this third subregime, all but a vanishing fraction of eigenstates remain nonresonant and the system thus still appears MBL in most respects. Based on our estimates of the location of the avalanche instability, it might be that the MBL phase is only part of subregime (i) and the other subregimes are entirely in the thermal phase, even though they look localized in most respects, so are in the finite-size MBL regime.

36 MATERIALS SCIENCE↗

Analysis of heat transfer and AuNPs-mediated photo-thermal inactivation of E. coli at varying laser powers using single-phase CFD modeling

In the wake of the COVID-19 pandemics, the demand for innovative and effective methods of bacterial inactivation has become a critical area of research, providing the impetus for this study. The purpose of this research is to analyze the AuNPs-mediated photothermal inactivation of E. coli. Gold nanoparticles irradiated by laser represent a promising technique for combating bacterial infection that combines high-tech and scientific progress. The intermediate aim of the work was to present the calibration of the model with respect to the gold nanorods experiment. The purpose of this work is to study the effect of initial concentration of E. coli bacteria, the design of the chamber and the laser power on heat transfer and inactivation of E. coli bacteria. Using the CFD simulation, the work combines three main concepts. 1. The conversion of laser light to heat has been described by a combination of three distinctive approximations: a- Discrete particle integration to take into account every nanoparticle within the system, b- Rayleigh-Drude approximation to determine the scattering and extinction coefficients and c- Lambert–Beer–Bourger law to describe the decrease in laser intensity across the AuNPs. 2. The contribution of the presence of E. coli bacteria to the thermal and fluid-dynamic fields in the microdevice was modeled by single-phase approach by determining the effective thermophysical properties of the water-bacteria mixture. 3. An approach based on a temperature threshold attained at which bacteria will be inactivated, has been used to predict bacterial response to temperature increases. The comparison of the thermal fields and temporal temperature changes obtained by the CFD simulation with those obtained experimentally confirms the accuracy of the light-heat conversion model derived from the aforementioned approximations. The results show a linear relationship between maximum temperature and variation in laser power over the range studied, which is in line with previous experimental results. It was also found that the temperature inside the microchamber can exceed 55 °C only when a laser power higher than 0.8 W is used, so bacterial inactivation begins. The experimental data allows to determinate the concentration of nanoparticles. This parameter is introduced into the mathematical model obtaining the same number of AuNPs. However, this assumption introduces a certain simplification, as in the mathematical model the distribution of nanoparticles is uniform. This work is directly connected to the use of gold nanoparticles for energy conversion, as well as the field of bacterial inactivation in microfluidic systems such as lab-on-a-chip. Presented mathematical and numerical models can be extended to the entire spectrum of wavelengths with particular use of white light in the inactivation of bacteria. This work represents a significant advancement in the field, as to the best of the authors’ knowledge, it is the first to employ a single-phase computational fluid dynamics (CFD) approach specifically combined with the thermal inactivation of bacteria. Moreover, this research pioneers the use of a numerical simulation to analyze the temperature threshold of photothermal inactivation of E. coli mediated by gold nanorods (AuNRs). The integration of these methodologies offers a new perspective on optimizing bacterial inactivation techniques, making this study a valuable contribution to both computational modeling and biomedical applications.

36 MATERIALS SCIENCE↗

Scaling of magnetic dissipation and particle acceleration in ABC fields

Using particle-in-cell numerical simulations with electron–positron pair plasma, we study how the efficiencies of magnetic dissipation and particle acceleration scale with the initial coherence length λ 0 in relation to the system size L of the two-dimensional ‘Arnold–Beltrami–Childress’ (ABC) magnetic field configurations. Topological constraints on the distribution of magnetic helicity in two-dimensional systems, identified earlier in relativistic force-free simulations, that prevent the high-(L/λ 0 ) configurations from reaching the Taylor state, limit the magnetic dissipation efficiency to about ϵ diss ≃60% . Here we find that the peak growth time scale of the electric energy τ E,peak scales with the characteristic value of initial Alfvén velocity β A,ini like τ E,peak ∝(λ 0 /L)β$^{–3}_{A,ini}$ . The particle energy change is decomposed into non-thermal and thermal parts, with non-thermal energy gain dominant only for high initial magnetisation. The most robust description of the non-thermal high-energy part of the particle distribution is that the power-law index is a linear function of the initial magnetic energy fraction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Program Review: Thermal Systems Pillar

Program Review: Thermal Systems Pillar Slides go over the 3 year plan for the integrated energy systems program DETAIL. The plan goes into connections between the DETAIL components and plans for future integration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling of Latent Heat Thermal Battery

A dynamic thermodynamic model is constructed in Modelica for the thermal battery portion of a heat pipe integrated thermal battery and is demonstrated using a shakedown test. The model is also leveraged to inform aspects of an experiment configuration. The theory section discusses modeling assumptions of the thermal battery system, establishes how melting and fusing is calculated, and how internal convection is modeled within the thermal battery. The shakedown test uses three charge-standby-discharge-standby cycles in which the charging cycles are 10 hours in length and the discharge cycles are 8 hours. System behavior including heat loss, temperature distributions and divergences, and internal convection behavior are presented. The model is then leveraged to show how experiment design can be informed through testing the model for insulation thickness impact on heat loss, round trip efficiency calculation, and heat tracing control.

25 ENERGY STORAGE↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Advances in high-pressure and high-temperature heat exchangers: Innovations via additive manufacturing and their applications

This paper provides a comprehensive overview of technological developments and applications for high-pressure and high-temperature (HPHT) heat exchangers produced through additive manufacturing (AM) techniques. As the demand for high-efficiency energy systems has been rising, the role of heat exchangers for thermal management and transport is becoming increasingly crucial. In this context, AM has emerged as a promising manufacturing solution to address the challenges posed by higher operating temperatures and/or pressures. This paper delves into three primary areas: the exploration of HPHT regimes supported by conventional heat exchangers, the impact of AM processes on thermal transport devices, and the discussion focused on HPHT heat exchangers produced via AM. The study examines the traditional manufacturing processes, materials, structures and geometries, and limitations of the commonly used heat exchangers for HPHT applications. Furthermore, it highlights the potential of AM in optimizing HPHT heat exchanger design, by reviewing studies that enable uniform flow distribution, minimization of fouling, and thermo-hydraulic performance augmentation without compromising structural stability. While addressing the limitations of cost, size, and other constraints, this study offers insights into the possibilities of AM in revolutionizing HPHT heat exchanger technology. The goal has been to fill the gap in literature by summarizing key studies, findings, and limitations, presenting a detailed examination, and proposing new areas for research. In conclusion, this review contributes to a deeper understanding of AM’s role in advancing HPHT heat exchangers for future energy systems.

36 MATERIALS SCIENCE↗

Hybrid Solar System (Final Scientific/Technical Report)

GTI Energy (GTI) teamed with the University of California at Merced (UCM) to scaleup the hybrid solar system (HSS) technology for demonstrating its performance at the US Gypsum (USG) plant in Plaster City, California. The technology integrates two-stage concentrating solar collector with matching particle thermal transport and storage (TSS) system to deliver cost-effective, and on-demand distributed high temperature industrial process heat up to 600°C with solar thermal, in this case to a gypsum kettle, to reduce its fuel use and carbon footprint. Current solar technologies, which reach these temperatures, are not distributable (towers) or cost-effective (dish). The research team developed a conceptual system design for host site retrofit, including preliminary heat balance, process flow diagram, particle to process heat exchanger and equipment placements at the site. Subsequently, parallel efforts were carried out at UCM to design, build and test a 12 m long commercial scale prototype concentrating thermal-only collector system and at GTI to design, build and test a matching 650°C capable particle TTS system. The nominal 50 kWth collector consists of a parabolic trough and three 4 m long two-stage receivers in series. Prior to on-sun testing, a 4 m long receiver was fabricated and successfully tested at 650 °C in a laboratory setting for 100 hrs of continuous operation showing less than 15% radiation loss. A 7 m wide x 17 m long parabolic trough was then installed at UCM for on-sun testing of the 12 m long receiver, and concurrently several 4 m long receivers were built. The optics of the parabolic trough were calibrated, and on-sun test were carried out on 12 m long receivers. During tests, the intense solar radiation (53x) caused the absorber tubes in the receivers to bend, reducing the overall optical efficiency. To address the bending issue, a self-consistent algorithm that includes ray tracing, thermal and deformation models was developed to perform thermal stress analysis on absorbers for parabolic solar collectors. Results obtained with this algorithm showed a dramatic rise in deformation as absorber tube length increases. A combined efficiency parameter that includes the occluded area for the mounts was developed to obtain an optimized tube length obtained. Based on the results, a length of 2.7 m for the absorber + 0.2 m for the coupler was chosen to minimize any bending and optimize optical efficiency while maintaining ease of mounting. The associated particle TTS system was designed, built and successfully tested at GTI. It includes storage, receiving and lock hoppers and piping that simulates the transfer of captured solar energy to an actual industrial furnace. Tests over 77 charge-discharge cycles demonstrated <2% particle degradation, with no problematic particle accumulations and no flow interruptions. The piping pressure drop was about 5 psi. The team also worked with Stanley Consultants (Stanley) to prepare conceptual and preliminary engineering packages to facilitate follow-on development and commercialization efforts. These include process and instrumentation diagram’s (P&ID’s), general arrangements, electrical one-line, project definitions document, equipment data sheets, schedule, and construction cost estimate for 2 MWth system. Updated HSS technology commercialization and customer engagement plans and detailed costs and evaluated market trade-offs and manufacturing.

03 NATURAL GAS↗

Utah FORGE: Optimization of a Plug-and-Perf Stimulation (Fervo Energy)

Information around the plug-and-perf treatment design at Utah FORGE by Fervo Energy. Objective and Purpose: - Develop a multistage hydraulic stimulation approach designed specifically to target the top three factors that control the technical and commercial viability of an EGS system: i) Achieving sufficient injectivity to support high cross-well flow rates ii) Distributing flow evenly across the wellbore and reservoir to maximize heat mining efficiency, ensure sustained heat transfer, and mitigate thermal breakthrough iii) Overcoming the effects of stress heterogeneity, stress shadowing, and variations in natural fracture properties during the stimulation treatment, leading to a more predictable stimulated reservoir volume and offset well placement - The following activities will be performed: i) Design, plan, and execute a multistage plug-and-perf stimulation treatment at a Fervo site with data acquisition and well testing activities aimed at addressing key technical aspects of the issues above ii) Perform data processing and interpretation of field results to translate the results form the Fervo site to a site-specific design at the Utah FORGE site iii) Design, plan, and execute a multistage plug-and-perf stimulation treatment design at the Utah FORGE site Methods and Approach: - Design a detailed data acquisition plan to maximize learning around: i) DFIT testing ii) Petrophysical logging, image logging iii) Permanent DAS/DTS fiber optic monitoring iv) Deep borehole microseismic monitoring v) Shallow borehole induced seismicity monitoring vi) Injection/production testing (RTA analysis, tracer testing) vii) Integrated numerical modeling and production forecasting

15 GEOTHERMAL ENERGY↗

COMPASS-U Global Heat Balance Calculations

COMPASS-U is a medium size, high magnetic field experimental tokamak (R = 0.9 m, B t = 5 T, and I p = 2 MA), built at the Institute of Plasma Physics, Czech Academy of Sciences (IPP-CAS). This global heat balance calculation for COMPASS-U was done at Princeton Plasma Physics Laboratory (PPPL). Based on our previous experience of building global thermal model for National Spherical Torus Experiment-Upgrade (NSTX-U) at PPPL, this 2-D global thermal model geometry represents a typical cross section of COMPASS-U machine. The model includes thermal radiation, conduction, and convection among components and also between the machine and outer environment. Helium gas heating/cooling was modeled with fluid element and surface element. This model was used to calculate component temperatures and heat distribution during heat up, cryogenic cool down, normal operation, and fault operation scenarios. Definition of 14 main thermal scenarios was provided by IPP-CAS. First nine are normal operation scenarios. Scenarios #10–#14 are fault scenarios. Results of thermal scenario #5 will be given and discussed in this article, including peak temperatures, temperature ratcheting, energy distribution, and required cooling power.