At least 145 records · Page 8

Thermal Model of a Current-Carrying Wire in a Vacuum

A computer program implements a thermal model of an insulated wire carrying electric current and surrounded by a vacuum. The model includes the effects of Joule heating, conduction of heat along the wire, and radiation of heat from the outer surface of the insulation on the wire. The model takes account of the temperature dependences of the thermal and electrical properties of the wire, the emissivity of the insulation, and the possibility that not only can temperature vary along the wire but, in addition, the ends of the wire can be thermally grounded at different temperatures. The resulting second-order differential equation for the steady-state temperature as a function of position along the wire is highly nonlinear. The wire is discretized along its length, and the equation is solved numerically by use of an iterative algorithm that utilizes a multidimensional version of the Newton-Raphson method.

Border, James↗

Data book for 12.5-inch diameter SRB thermal model water flotation test; 1.29 psia, series P022

Data acquired from tests conducted to determine how thermal conditions affect SRB (Space Shuttle Solid Rocket Booster) flotation at a scaled pressure of 1.29 psia are presented. Included are acceleration, pressure, and temperature data recorded from initial water impact to final flotation position using a 12.5-inch diameter thermal model of the SRB. Nineteen valid tests were conducted. These thermal tests indicated the following basic differences relative to the ambient temperature and pressure model tests: (1) more water was taken on board during penetration and (2) model flotation/sinking was temperature sensitive.

Allums, S. L.↗

Development and Implementation of Efficiency-Improving Analysis Methods for the SAGE III on ISS Thermal Model Originating

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle in 2015. A detailed thermal model of the SAGE III payload has been developed in Thermal Desktop (TD). Several novel methods have been implemented to facilitate efficient payload-level thermal analysis, including the use of a design of experiments (DOE) methodology to determine the worst-case orbits for SAGE III while on ISS, use of TD assemblies to move payloads from the Dragon trunk to the Enhanced Operational Transfer Platform (EOTP) to its final home on the Expedite the Processing of Experiments to Space Station (ExPRESS) Logistics Carrier (ELC)-4, incorporation of older models in varying unit sets, ability to change units easily (including hardcoded logic blocks), case-based logic to facilitate activating heaters and active elements for varying scenarios within a single model, incorporation of several coordinate frames to easily map to structural models with differing geometries and locations, and streamlined results processing using an Excel-based text file plotter developed in-house at LaRC. This document presents an overview of the SAGE III thermal model and describes the development and implementation of these efficiency-improving analysis methods.

Liles, Kaitlin↗

Large loop thermal models of solar hard X-ray bursts

Results for small loop thermal models of hard X-ray bursts are extended to large loops. In this model a magnetic arch with a coronal length of 45,000 km has the electrons near the top heated to temperatures above 1 billion K. The resulting conduction fronts which form are dominated by collisionless processes and travel down the arch to the transition region and chromosphere where they evaporate off part of the latter. This relatively cool material travels back up the loop and eventually quenches the source for energy injection times of order 10 sec. Most of the X-ray emission comes from the footpoints of the arch over most of the source lifetime and the spectrum is a power law with a typical spectral index of 3.0. Even though the efficiency gain in this model is only 2.8, it is much easier from the point of view of plasma physics to heat all the electrons in a plasma than to accelerate a substantial fraction of them.

Smith, D. F.↗

Cryogenic thermal modeling of microwave high density signaling

Superconducting quantum computers require microwave control lines running from room temperature to the mixing chamber of a dilution refrigerator. Adding more lines without preliminary thermal modeling to make predictions risks overwhelming the cooling power at each thermal stage. In this paper, we investigate the thermal load of SC-086/50-SCN-CN semi-rigid coaxial cable, which is commonly used for the control and readout lines of a superconducting quantum computer, as we increase the number of lines to a quantum processor. We investigate the makeup of the coaxial cables, verify the materials and dimensions, and experimentally measure the total thermal conductivity of a single cable as a function of the temperature from cryogenic to room temperature values. We also measure the cryogenic DC electrical resistance of the inner conductor as a function of temperature, allowing for the calculation of active thermal loads due to Ohmic heating. Fitting this data produces a numerical thermal conductivity function used to calculate the static heat loads due to thermal transfer within the wires resulting from a temperature gradient. The resistivity data is used to calculate active heat loads, and we use these fits in a cryogenic model of a superconducting quantum processor in a typical Bluefors XLD1000-SL dilution refrigerator, investigating how the thermal load increases with processor sizes ranging from 100 to 225 qubits. We conclude that the theoretical upper limit of the described architecture is approximately 200 qubits. However, including an engineering margin in the cooling power and the available space for microwave readout circuitry at the mixing chamber, the practical limit is approximately 140 qubits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Computational Fluid Dynamics and Thermal Desktop Thermal Modeling for Assessment of the EMU in Support of ISS EVA 80

Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.

Blain Ryan Lancaster↗

Integrated Computational Fluid Dynamics and Thermal Desktop Thermal Modeling for Assessment of the EMU in Support of ISS EVA 80

Following the reports of water accumulation in the Extravehicular Mobility Unit (EMU) helmet during the ISS US EVA-80, various efforts for mitigation and further understanding of this phenomenon have been undertaken with the goal of prevention and to ensure crew safety in future EVAs. In support of this goal, a combination of Thermal Desktop thermal modeling and Computational Fluid Dynamics (CFD) has been performed in order to characterize the performance of the EMU components, specifically those within the ventilation/cooling water loops. This modeling effort evaluates the dry/wet gas pressure drop and flow distribution through gas and liquid flow paths using CFD, as well as a two-phase flow assessment of condensation production and water separation/removal performance using an integrated Thermal Desktop model of important EMU ventilation loop components. The models assess this overall thermal-fluid performance in comparison with previous existing models, design points, and historical EVA data using their inputs.

EVA 80↗

I-deas TMG to NX Space Systems Thermal Model Conversion and Computational Performance Comparison

CAD/CAE packages change on a continuous basis as the power of the tools increase to meet demands. End -users must adapt to new products as they come to market and replace legacy packages. CAE modeling has continued to evolve and is constantly becoming more detailed and complex. Though this comes at the cost of increased computing requirements Parallel processing coupled with appropriate hardware can minimize computation time. Users of Maya Thermal Model Generator (TMG) are faced with transitioning from NX I -deas to NX Space Systems Thermal (SST). It is important to understand what differences there are when changing software packages We are looking for consistency in results.

Thermal Model Generator (TMG)↗

Thermal modeling of the NASA-Ames Research Center Cryogenic Optical Test Facility and a single-arch, fused-natural-quartz mirror

A thermal model of the dewar and optical system of the Cryogenic Optical Test Facility at NASA-Ames Research Center was developed using the computer codes SINDA and MONTE CARLO. The model was based on the geometry, boundary conditions, and physical properties of the test facility and was developed to investigate heat transfer mechanisms and temperatures in the facility and in test mirrors during cryogenic optical tests. A single-arch, fused-natural-quartz mirror was the first mirror whose thermal loads and temperature distributions were modeled. From the temperature distribution, the thermal gradients in the mirror were obtained. The model predicted that a small gradient should exist for the single arch mirror. This was later verified by the measurement of mirror temperatures. The temperatures, predicted by the model at various locations within the dewar, were in relatively good agreement with the measured temperatures. The model is applicable to both steady-state and transient cooldown operations.

Ng, Y. S.↗

Data book for 12.5-inch diameter SRB thermal model water flotation test - 14.7 psia, series P024

Tests were conducted to determine how thermal conditions affect space shuttle solid rocket booster (SRB) flotation. Acceleration, pressure, and temperature data were recorded from initial water impact to final flotation position using a 12.5-inch diameter thermal model of the SRB at ambient pressure. The model was 136.9 inches long and weighed 117.3 lbm. The tests indicated the following differences from ambient temperature tests: (1) significant negative static pressures can occur during penetration; (2) maximum penetration is increased; and (3) final flotation is in the spar buoy mode.

Allums, S. L.↗

A simplified generic cryostat thermal model for predicting cryogen mass and lifetime

This study presents a simple generic cryostat thermal model developed for predicting cryogen mass and the lifetime of cryogenic space telescopes. The model is based on a lumped parameter representation of eight nodes and over 35 conductors. The major telescope Dewar components represented as nodes are the main cryogen tank, the three vapor-cooled shields, the outer shell, barrel baffle, and the barrel baffle heat exchanger. The input to the model consists of the vapor-cooled shield, support straps and instrument cable geometry, and the cryostat heat loads from the instrument and through the aperture. The predictions from the model were compared with those from the more detailed models of IRAS, COBE, and SIRTF. Correlation of the helium flow rates of the IRAS and COBE Dewars was 12 percent above the actual flight or ground test data and for SIRTF it was less than 2 percent of the prediction from the detailed model.

Birur, G. C.↗

Thermal Modeling of Zero Boil Off Tank Experiment

Understanding fluid behavior in microgravity environments is essential to further development of cryogenic storage in space environments. The Zero Boil Off Tank (ZBOT) experiment was designed to investigate two-phase pressurization and depressurization of a tank in a microgravity environment. The test fluid was the refrigerant Perfluoro-normal-Pentane (PNP). Thermal modeling for the ZBOT model was conducted using Thermal Desktop and SINDA/FLUINT. The temperature distribution within the fluid of the tank is of particular interest. This particular work is centered on ascertaining the thermal behavior of the refrigerant in order to build more complete models of fluid in microgravity. Separate cases were run modeling experiments that were conducted both on the ground and on the International Space Station (ISS) to compare 1g and microgravity environments. The microgravity modeling cases consisted of a fluid lump representing the vapor ullage suspended in a solid to represent the liquid. Mass flow between the liquid and vapor was modeled using the Schrage equation for mass flow. Initial results indicate that the pressure rise and temperature increase within the fluid closely align with the experimental data by matching initial conditions of the experiment. This work is ongoing and will yield further insights into the thermal behavior of fluid mixing in microgravity.

low-gravity fluid modeling↗

Transient Thermal Model and Analysis of the Lunar Surface and Regolith for Cryogenic Fluid Storage

A transient thermal model of the lunar surface and regolith was developed along with analytical techniques which will be used to evaluate the storage of cryogenic fluids at equatorial and polar landing sites. The model can provide lunar surface and subsurface temperatures as a function of latitude and time throughout the lunar cycle and season. It also accounts for the presence of or lack of the undisturbed fluff layer on the lunar surface. The model was validated with Apollo 15 and Clementine data and shows good agreement with other analytical models.

Christie, Robert J.↗

Thermal Modeling and Analysis of a Cryogenic Tank Design Exposed to Extreme Heating Profiles

A cryogenic test article, the Generic Research Cryogenic Tank, was designed to qualitatively simulate the thermal response of transatmospheric vehicle fuel tanks exposed to the environment of hypersonic flight. One-dimensional and two-dimensional finite-difference thermal models were developed to simulate the thermal response and assist in the design of the Generic Research Cryogenic Tank. The one-dimensional thermal analysis determined the required insulation thickness to meet the thermal design criteria and located the purge jacket to eliminate the liquefaction of air. The two-dimensional thermal analysis predicted the temperature gradients developed within the pressure-vessel wall, estimated the cryogen boiloff, and showed the effects the ullage condition has on pressure-vessel temperatures. The degree of ullage mixing, location of the applied high-temperature profile, and the purge gas influence on insulation thermal conductivity had significant effects on the thermal behavior of the Generic Research Cryogenic Tank. In addition to analysis results, a description of the Generic Research Cryogenic Tank and the role it will play in future thermal structures and transatmospheric vehicle research at the NASA Dryden Flight Research Facility is presented.

Stephens, Craig A.↗