Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Time and frequency measuring metrological equipment in the USSR

The complex of the means of providing time and frequency traceability in the USSR includes the system of time and frequency standards of the National Time and Frequency Calibration Service, time and frequency transfer facilities and local time and frequency standards. Control on measurement correctness is performed by the All-Union State Standard calibration service. The hardware of most of the above-mentioned systems is provided by the instruments developed by our institute. A common scientific and technological approach allowed us to create a unified system of time-frequency equipment composed of widely used serial instruments, sets, automated systems and complexes. Primary frequency standards of different classes, time and frequency references and instruments are based on the unified system. CH1-70 hydrogen frequency standard and its CH1-70A, CH1-80 modifications are used in the group time and frequency standards. Measuring time and data processing techniques, and also instrumentation specifications on the results of 10-year operation are given. The existing system provides time-frequency measurements with 2 times 10(exp -13) plus or minus 1 times 10(exp -14) accuracy.

Uljanov, Adolph A.↗

Liquid argon time projection chamber calibration using cosmogenic muons, and measurement of neutrino induced charged kaon production in argon in the charged current mode (MicroBooNE experiment)

The MicroBooNE experiment at Fermilab uses the novel LArTPC technology to reconstruct neutrino interactions with liquid argon. The experiment consists of a detector having an active mass of 85 tons of liquid argon, where the operational electric field of the TPC is 0.273 kV/cm. While BNB neutrino beam at Fermilab is the main source for neutrinos for the experiment having an average energy of ~0.8 GeV, the NUMI neutrino beam at Fermilab also provides high energy neutrinos to perform different physics analyses. The MicroBooNE experiment has been in operation since october 2015. Its major physics goals include investigating into the anomalous production of electron neutrino like events as observed by MiniBooNE and LSND experiments and detail studies of neutrino-argon cross sections at lower neutrino energies. Moreover, the experiment will also serve as R&D for future LArTPC experiments like the already proposed SBN and DUNE programs. One of the major operational requirements of any LArTPC experiment including MicroBooNE is to achieve a high liquid argon purity keeping the electronegative contaminants like H2O and O2 at low concentration levels. This dissertation first describes how to perform an electron attenuation measurement using cosmogenic muons, which provides a handle over the the amount of electronegative impurities inside our detector medium. Likewise this measurement also serves as the first step towards reconstruction of particle energies as MicroBooNE must compensate for the loss of ionization electrons due to capture by electronegative contaminants. Secondly, the discussion is about how to calibrate any LArTPC detector in removing any spatial and temporal variations of the dQ/dx (charge deposited per unit length) spectrum using cosmogenic muons and then how to calculate correct energies of particle interactions with these calibrated out dQ/dx values. The translation of dQ/dx to particle energies (dE/dx - energy deposited per unit lengt h) makes use of the stopping muons coming from neutrino inte! ractions as the standard candle. The final discussion is about the neutrino induced charged kaon production at charged current mode in the lower neutrino energies of MicroBooNE experiment. This measurement is crucial as there is no such measurement so far on argon at the scale of neutrino energies used for MicroBooNE while already existing measurements on lighter nuclear targets are also sparse. This dissertation presents the first identified neutrino induced kaon candidates in MicroBooNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration Valve With Built-In Test Port

Calibration valve includes built-in test port for calibrating control-panel gauges in place, without having to remove them for calibration. Use of this valve reduces number of plumbing parts and thus number of potential leakage points. Application of calibration valve saves time when calibrating control-panel gauges or transducers and prevents damage or loss of instruments by not having to remove them from control panel for calibration.

Pilichi, Carmine A.↗

Comparative Analysis of Radiometer Systems Using Non-Stationary Processes

Radiometers require periodic calibration to correct for instabilities in the receiver response. Various calibration techniques exist that minimize the effect of instabilities in the receivers. The optimal technique depends upon many parameters. Some parameters are constrained by the particular application and others can be chosen in the system design. For example, the measurement uncertainty may be reduced to the limits of the resolution of the measurement (sensitivity) if periodic absolute calibration can be performed with sufficient frequency. However if the period between calibrations is long, a reference-differencing technique, i.e. Dicke-type design, can yield better performance. The measurement uncertainty not only depends upon the detection scheme but also on the number of pixels between calibrations, the integration time per pixel, integration time per calibration reference measurement, calibration reference temperature, and the brightness temperature of what is being measured. The best scheme for reducing the measurement uncertainty also depends, in large part, on the stability of the receiver electronics. In this presentation a framework for evaluating calibration schemes for a wide range of system architectures is presented. Two methods for treating receiver non-stationarity are compared with radiometer measurements.

Racette, Paul↗

Methods and apparatus for calibration and response time testing of level sensors

Systems and methods of diagnosing performance of a level sensor of a fluid test chamber, including a data acquisition and processing unit configured to receive output signals of one or more level sensors that are installed to a fluid chamber, the data acquisition and processing unit being configured to connect to the one or more level sensors to record and process the output signals to test operation of the one or more level sensors.

Hashemian, Alexander Hashem↗

Legacy Survey of Space and Time Data Preview 1: calibrations dataset type

The Legacy Survey of Space and Time Data Preview 1 (DP1) is the first release of data from the NSF-DOE Vera C. Rubin Observatory. It consists of raw and calibrated single-epoch images, co-adds, difference images, detection catalogs, and other derived data products. DP1 is based on 1792 science-grade optical/near-infrared exposures acquired over 48 distinct nights by the Rubin Commissioning Camera, LSSTComCam, on the Simonyi Survey Telescope at the Summit Facility on Cerro Pachón, Chile during the first on-sky commissioning campaign in late 2024. DP1 covers a total of approximately 15 sq. deg. over seven roughly equally-sized non-contiguous fields, each independently observed in six broad photometric bands, ugrizy, spanning a range of stellar densities and latitudes and overlapping with external reference datasets. This dataset is a subset of the full data release consisting of the calibrations dataset type. These are a collection of calibration datasets such as biases, darks, and flats used to construct the data release. This release contains 496 datasets of this type.

79 ASTRONOMY AND ASTROPHYSICS↗

Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes

Global measurement of terrestrial snow cover is critical to two of the NASA Earth Science focus areas: (1) climate variability and change and (2) water and energy cycle. For radar backscatter measurements, Ku-band frequencies, scattered mainly within the volume of the snowpack, are most suitable for the SWE (snow-water equivalent) measurements. To isolate the complex effects of different snowpack (density and snowgrain size), and underlying soil properties and to distinctly determine SWE, the space-based synthetic aperture radar (SAR) system will require a dual-frequency (13.4 and 17.2 GHz) and dual polarization approach. A transmit/receive (T/R) module was developed operating at Ku-band frequencies to enable the use of active electronic scanning phased-array antenna for wide-swath, high-resolution SAR imaging of terrestrial snow cover. The T/R module has an integrated calibrator, which compensates for all environmental- and time-related changes, and results in very stable power and amplitude characteristics. The module was designed to operate over the full frequency range of 13 to 18 GHz, although only the two frequencies, 13.4 GHz and 17.2 GHz, will be used in this SAR radar application. Each channel of the transmit module produces > 4 W (35 dbm) over the operating bandwidth of 20 MHz. The stability requirements of <0.1 dB receive gain accuracy and <0.1 dB transmit power accuracy over a wide temperature range are achieved using a self-correction scheme, which does real-time amplitude calibration so that the module characteristics are continually corrected. All the calibration circuits are within the T/R module. The timing and calibration sequence is stored in a control FPGA (field-programmable gate array) while an internal 128K 8bit high-speed RAM (random access memory) stores all the calibration values. The module was designed using advanced components and packaging techniques to achieve integration of the electronics in a 2 x6.5x1-in. (5x17x2.5-cm) package. The module size allows 4 T/R modules to feed the 16 16-element subarray on an antenna panel. The T/R module contains four transmit channels and eight receive channels (horizontal and vertical polarizations).

Andricos, Constantine↗

Automatic Échelle Spectrograph Wavelength Calibration

Time-domain astronomy and the increasing number of exoplanet candidates call for reliable, robust, and automatic wavelength calibration. We present an algorithm for wavelength-calibrating échelle spectrographs that uses order-by-order extracted spectra and a list of laboratory wavelengths. Our approach is fully automatic and does not need the pixel locations of certain spectral features with which to anchor the wavelength solution, nor the true order number of each diffraction order. We use spectral features that are duplicated in adjacent orders to establish the scale-invariant component of the wavelength solution. We then match the central wavelengths of spectral features to laboratory wavelengths to establish the scale and higher-order components of the wavelength solution. We demonstrate our method on the four spectrographs of Las Cumbres Observatory’s Network of Robotic Échelle Spectrographs (NRES), on the High Accuracy Radial Velocity Planet Searcher (HARPS) spectrograph, and on synthetic data. We obtain a velocity-equivalent precision of ∼10 m s{sup −1} on NRES. We achieve ∼1 m s{sup −1} on HARPS, which agrees with the precision reported by the HARPS team. On synthetic data, we achieve the velocity precision set by Gaussian centroiding errors. Our algorithm likely holds for a wide range of spectrographs beyond the five presented here. We provide an open-source Python package, xwavecal, which outputs wavelength-calibrated spectra as well as the wavelengths of spectral features.

79 ASTRONOMY AND ASTROPHYSICS↗

In-flight gyro drift rate calibration on the Viking Orbiters

The drift rates of the attitude control gyros onboard the Viking Orbiters were calibrated several times during flight. The calibration was performed by engaging the gyro control of attitude for a six-hour period, recording the Viking Orbiter coordinates of the sun and the roll reference star as a function of time, and processing these data by a computer program. The computer program calculated drift rates for each data increment, and then smoothed the calculated rate versus the time function for all the data on the basis of a Gauss-Markov gyro-drift model. The effects of data noise were minimized by using a relatively long time constant in the Gauss-Markov model and by empirically determining a set of corrections for celestial inertial scale factor error differences. In this way the rms error of the data fit was lessened.

Breckenridge, W. G.↗

Post-Calibration Uncertainty Analysis for Travel Times at a Naval Weapons Industrial Reserve Plant

The Naval Weapons Industrial Reserve Plant (NWIRP) in McGregor, Texas began manufacturing explosives in 1980 and several hazardous chemicals were discovered in lakes and streams surrounding the site in 1998. Contaminants traveled to local lakes and streams much faster than initially predicted. This research estimated contaminant travel times and identified locations where monitoring wells should be installed to yield the greatest reductions in uncertainties in travel-time predictions. To this end, groundwater and particle-tracking models for NWIRP site were built to predict hydraulic heads and contaminant travel times. Next, parameter (hydraulic conductivities) uncertainties, parameter identifiabilities, observation (hydraulic heads) worth, and predictive (contaminant travel times) uncertainties were quantified. Parameter uncertainties were reduced by up to 92%; a total of 19 of 158 parameters were at least moderately identifiable; travel-time uncertainties were reduced up to 92%. Additionally, travel-time predictions and post-calibration parameter distributions were generated using the null-space Monte Carlo (NSMC) technique. NSMC predicted that conservative tracers exited the flow system within a year, which matches with field data. Finally, an observations-worth analysis found that additional 11 more measurements would reduce travel-time uncertainties by factors from 1.04 to 4.3 over existing data if monitoring wells were installed at the suggested locations.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation of RF Circuitry for Real-Time Digital Beam-Forming SAR Calibration Schemes

The SweepSAR architecture for space-borne remote sensing applications is an enabling technology for reducing the temporal baseline of repeat-pass interferometers while maintaining near-global coverage. As part of this architecture, real-time digital beam-forming would be performed on the radar return signals across multiple channels. Preserving the accuracy of the combined return data requires real-time calibration of the transmit and receive RF paths on each channel. This paper covers several of the design considerations necessary to produce a practical implementation of this concept.

calibration↗

Time-lapse VSP integration and calibration of subsurface stress field utilizing machine learning approaches: A case study of the morrow B formation, FWU

This study aims to develop a methodology for calibrating subsurface stress changes through time-lapse vertical seismic profiling (VSP) integration. The selected study site is a region around the injector well located within Farnsworth field unit (FWU), where there is an ongoing CO 2 -enhanced oil recovery (EOR) operation. In our study, a site-specific rock physics model was created from extensive geological, geophysical, and geomechanical characterization through 3D seismic data, well logs, and core assessed as part of the 1D MEM conducted on the characterization well within the study area. Here, the Biot-Gassmann workflow was utilized to combine the rock physics and reservoir simulation outputs to determine the seismic velocity change due to fluid substitution. Modeled seismic velocities attributed to mean effective stress were determined from the geomechanical simulation outputs, and the stress-velocity relationship developed from ultrasonic seismic velocity measurements. A machine learning-assisted workflow comprised of an artificial neural network and a particle swarm optimizer (PSO) was utilized to minimize a penalty function created between the modeled seismic velocities and the observed time-lapse VSP dataset. The successful execution of this workflow has affirmed the suitability of acoustic time-lapse measurements for 4D-VSP geomechanical stress calibration pending measurable stress sensitivities within the anticipated effective stress changes and the availability of suitable and reliable datasets for petroelastic modeling. © 2023 Society of Chemical Industry and John Wiley & Sons, Ltd.

58 GEOSCIENCES↗

Real-Time Attitude Independent Three Axis Magnetometer Calibration

In this paper new real-time approaches for three-axis magnetometer sensor calibration are derived. These approaches rely on a conversion of the magnetometer-body and geomagnetic-reference vectors into an attitude independent observation by using scalar checking. The goal of the full calibration problem involves the determination of the magnetometer bias vector, scale factors and non-orthogonality corrections. Although the actual solution to this full calibration problem involves the minimization of a quartic loss function, the problem can be converted into a quadratic loss function by a centering approximation. This leads to a simple batch linear least squares solution. In this paper we develop alternative real-time algorithms based on both the extended Kalman filter and Unscented filter. With these real-time algorithms, a full magnetometer calibration can now be performed on-orbit during typical spacecraft mission-mode operations. Simulation results indicate that both algorithms provide accurate integer resolution in real time, but the Unscented filter is more robust to large initial condition errors than the extended Kalman filter. The algorithms are also tested using actual data from the Transition Region and Coronal Explorer (TRACE).

Crassidis, John L.↗

Evaluation of the Applicability of Solar and Lamp Radiometric Calibrations of a Precision Sun Photometer Operating Between 300 and 1025 nm

Over a period of 3 year a precision Sun photometer (SPM) operating between 300 and 1025 nm was calibrated four times at three different high-mountain sites in Switzerland, Germany, and the United States by means of the Langley-plot technique. We found that for atmospheric window wavelengths the total error (2 sigma-statistical plus systematic errors) of the calibration constants V(sub 0)(lambda), the SPM voltage in the absence of any attenuating atmosphere, can be kept below 1.60% in the UV-A and blue, 0.9% in the mid-visible, and 0.6% in the near-infra red spectral region. For SPM channels within strong water-vapor or ozone absorption bands a modified Langley-plot technique was used to determine V(sub 0)(lambda) with a lower accuracy. Within the same period of time, we calibrated the SPM five times using irradiance standard lamps in the optical labs of the Physikalisch-Meteorologisches Observatorium Davos and World Radiation Center, Switzerland, and of the Remote Sensing Group of the Optical Sciences Center, University of Arizona, Tucson, Arizona. The lab calibration method requires knowledge of the extraterrestrial spectral irradiance. When we refer the standard lamp results to the World Radiation Center extraterrestrial solar irradiance spectrum, they agree with the Langley results within 2% at 6 or 13 SPM wavelengths. The largest disagreement (4.4%) is found for the channel centered at 610 nm. The results of these intercomparisons change significantly when the lamp results are referred to two different extraterrestrial solar irradiance spectra that have become recently available.

Schmid, Beat↗

Real-time attitude determination and gyro calibration

We present results for two real-time filters prototyped for the Compton Gamma Ray Observatory (GRO), the Extreme Ultraviolet Explorer (EUVE), the Cosmic Background Explorer (COBE), and the next generation of Geostationary Operational Environmental Satellites (GOES). Both real and simulated data were used to solve for attitude and gyro biases. These filters promise advantages over single-frame and batch methods for missions like GOES, where startup and transfer-orbit operations require quick knowledge of attitude and gyro biases.

Challa, M.↗

The two-way time synchronization system via a satellite voice channel

A newly developed two-way time synchronization system is described in this paper. The system uses one voice channel at a SCPC satellite digital communication earth station, whose bandwidth is only 45 kHz, thus saving satellite resources greatly. The system is composed of one master station and one or several, up to sixty-two, secondary stations. The master and secondary stations are equipped with the same equipment, including a set of timing equipment, a synthetic data terminal for time synchronizing, and a interface unit between the data terminal and the satellite earth station. The synthetic data terminal for time synchronization also has an IRIG-B code generator and a translator. The data terminal of master station is the key part of whole system. The system synchronization process is full automatic, which is controlled by the master station. Employing an autoscanning technique and conversational mode, the system accomplishes the following tasks: linking up liaison with each secondary station in turn, establishing a coarse time synchronization, calibrating date (years, months, days) and time of day (hours, minutes, seconds), precisely measuring the time difference between local station and the opposite station, exchanging measurement data, statistically processing the data, rejecting error terms, printing the data, calculating the clock difference and correcting the phase, thus realizing real-time synchronization from one point to multiple points. We also designed an adaptive phase circuit to eliminate the phase ambiguity of the PSK demodulator. The experiments have shown that the time synchronization accuracy is better than 2 mu S. The system has been put into regular operation.

Heng-Qiu, Zheng↗

Comparing complex impedance and bias step measurements of Simons Observatory transition edge sensors

The Simons Observatory (SO) will perform ground-based observations of the cosmic microwave background (CMB) with several small and large aperture telescopes, each outfitted with thousands to tens of thousands of superconducting aluminum manganese (AlMn) transition-edge sensor bolometers (TESs). In-situ characterization of TES responsivities and effective time constants will be required multiple times each observing-day for calibrating time-streams during CMB map-making. Effective time constants are typically estimated in the field by briefly applying small amplitude square-waves on top of the TES DC biases, and fitting exponential decays in the bolometer response. These so-called “bias step” measurements can be rapidly implemented across entire arrays and therefore are attractive because they take up little observing time. However, individual detector complex impedance measurements, while too slow to implement during observations, can provide a fuller picture of the TES model and a better understanding of its temporal response. Here, we present the results of dark TES characterization of many prototype SO bolometers and compare the effective thermal time constants measured via bias steps to those derived from complex impedance data.

Nicholas F. Cothard↗