Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved X-ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Giant Electrostriction via Nanodomain Engineering in Relaxor Ferroelectric Polymers

Relaxor ferroelectric (RFE) polymers hold great promise for artificial muscles due to their high actuation strain, high loading stress, and fast response. However, the structural origin underlying their large electrostrictive deformation remains elusive. In this study, we investigate poly(vinylidene fluoride-co-trifluoroethylene) [P(VDF-TrFE)]-based RFE terpolymers, incorporating 1,1-chlorofluoroethylene (CFE) or chlorotrifluoroethylene (CTFE) (the terpolymers are denoted as terP-CFE and terP-CTFE, respectively) as termonomers. Although both terpolymers show similar semicrystalline morphology, drastically different electrostrictive properties are observed. Specifically, the terP-CFE annealed at 100 °C achieves a record-high transverse strain of ∼10.6%, whereas 100 °C-annealed terP-CTFE only shows a much lower actuation strain of ∼4.2% at the same poling field of 190 MV/m. To elucidate the origin of this difference, time-resolved wide-angle X-ray diffraction, small-angle X-ray scattering, and Fourier transform infrared experiments are performed during in situ electric poling. An RFE-to-ferroelectric (FE) crystal phase transition is observed for terP-CFE but is absent for terP-CTFE. Beyond the contribution of the crystalline phase, the oriented amorphous fraction and crystalline defects (e.g., taut-tie molecules) also play significant roles in enhancing electrostriction. In conclusion, this mechanistic insight provides a valuable foundation for the rational design of next-generation RFE polymers with tunable properties through defect engineering of their semicrystalline structures.

36 MATERIALS SCIENCE↗

Time-resolved X-ray diffraction diagnostic development for the National Ignition Facility

Here we present the development of an experimental platform that can collect four frames of x-ray diffraction data along a single line of sight during laser-driven, dynamic-compression experiments at the National Ignition Facility. The platform is comprised of a diagnostic imager built around ultrafast sensors with a 2-ns integration time, a custom target assembly that serves also to shield the imager, and a 10-ns duration, quasi-monochromatic x-ray source produced by laser-generated plasma. We demonstrate the performance with diffraction data for Pb ramp compressed to 150 GPa and illuminated by a Ge x-ray source that produces ∼7 × 10 11 , 10.25-keV photons/ns at the 400 μm diameter sample.

36 MATERIALS SCIENCE↗

Capturing Coupled Structural and Electronic Motions During Excited-State Intramolecular Proton Transfer via Computational Multiedge Resonant Inelastic X-ray Scattering

Proton-transfer processes build the foundation of many chemical processes. In Excited State Intramolecular Proton Transfer (ESIPT) processes the proton transfer process is impulsively started through light. Here, in this study, we explore the changes in coupled atomic and electronic motions during and following ESIPT through computational time-resolved Resonant Inelastic X-ray Scattering (trRIXS). Excited-state Ab Initio Molecular Dynamics (AIMD) simulations combined with Time-Dependent Density Functional Theory (TDDFT) calculations were performed for 10-hydroxybenzo[h]quinoline to obtain trRIXS signatures. RIXS at both the nitrogen and oxygen K-edges were computed to resolve the dynamics electronic structure from both the proton donor and acceptor perspective. The results show how RIXS can reveal the local electronic structure, the coupling between different electronic states and how electronic structure and coupling change during the proton transfer process. Additionally, we observe a strong correlation between spectral changes and structural changes during ESIPT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Terahertz Field Control of the Emergent Magnetic and Electronic Interactions at Oxide Interfaces

Ultrafast electric-field control of emergent electronic and magnetic states at oxide interfaces offers exciting prospects for the development of the next generation of energy-efficient devices. Here, it is demonstrated that the electronic structure and emergent ferromagnetic interfacial state in epitaxial LaNiO3/CaMnO3 superlattices can be effectively controlled using intense, single-cycle THz electric-field pulses. A suite of advanced X-ray spectroscopic techniques is employed to measure a detailed magneto-optical profile and the thickness of the ferromagnetic interfacial layer. Then, a combination of time-resolved and temperature-dependent optical measurements is used to disentangle several correlated electronic and magnetic processes driven by ultrafast, high-field THz pulses. Sub-picosecond non-equilibrium Joule heating of the electronic system is observed, ultrafast demagnetization of the ferromagnetic interfacial layer, and slower dynamics indicative of a change in the magnetic state of the superlattice due to the transfer of spin-angular momentum to the lattice. These findings suggest a promising avenue for the efficient control of 2D ferromagnetic states at oxide interfaces using ultrafast electric-field pulses.

X-ray spectroscopy and scattering↗

Watching Excited State Dynamics with Optical and X-ray Probes: The Excited State Dynamics of Aquocobalamin and Hydroxocobalamin

Femtosecond time-resolved X-ray absorption (XANES) at the Co K-edge, X-ray emission (XES) in the Co Kβ and valence-to-core regions, and broadband UV–vis transient absorption are combined to probe the femtosecond to picosecond sequential atomic and electronic dynamics following photoexcitation of two vitamin B12 compounds, hydroxocobalamin and aquocobalamin. Polarized XANES difference spectra allow identification of sequential structural evolution involving first the equatorial and then the axial ligands, with the latter showing rapid coherent bond elongation to the outer turning point of the excited state potential followed by recoil to a relaxed excited state structure. Time-resolved XES, especially in the valence-to-core region, along with polarized optical transient absorption suggests that the recoil results in the formation of a metal-centered excited state with a lifetime of 2–5 ps. In conclusion, this combination of methods provides a uniquely powerful tool to probe the electronic and structural dynamics of photoactive transition-metal complexes and will be applicable to a wide variety of systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XRISM Spectroscopy of the Fe Kα Emission Line in the Seyfert Active Galactic Nucleus NGC 4151 Reveals the Disk, Broad-line Region, and Torus

Abstract We present an analysis of the first two XRISM/Resolve spectra of the well-known Seyfert-1.5 active galactic nucleus (AGN) in NGC 4151, obtained in 2023 December. Our work focuses on the nature of the narrow Fe K α emission line at 6.4 keV, the strongest and most common X-ray line observed in AGN. The total line is found to consist of three components. Even the narrowest component of the line is resolved with evident Fe K α ,1 (6.404 keV) and K α ,2 (6.391 keV) contributions in a 2:1 flux ratio, fully consistent with neutral gas with negligible bulk velocity. Subject to the limitations of our models, the narrowest and intermediate-width components are consistent with emission from optically thin gas, suggesting that they arise in a disk atmosphere and/or wind. Modeling the three line components in terms of Keplerian broadening, they are readily associated with (1) the inner wall of the “torus,” (2) the innermost optical “broad-line region” (or “X-ray BLR”), and (3) a region with a radius of r ≃ 100 GM / c 2 that may signal a warp in the accretion disk. Viable alternative explanations of the broadest component include a fast-wind component and/or scattering; however, we find evidence of variability in the narrow Fe K α line complex on timescales consistent with small radii. The best-fit models are statistically superior to simple Voigt functions, but when fit with Voigt profiles the time-averaged lines are consistent with a projected velocity broadening of FWHM = 1600 − 200 + 400 km s − 1 . Overall, the resolution and sensitivity of XRISM show that the narrow Fe K line in AGN is an effective probe of all key parts of the accretion flow, as it is currently understood. We discuss the implications of these findings for our understanding of AGN accretion, future studies with XRISM, and X-ray-based black hole mass measurements.

Audard, Marc (ORCID:000000034721034X)↗

3D-printed sheet jet for stable megahertz liquid sample delivery at X-ray free-electron lasers

X-ray free-electron lasers (XFELs) can probe chemical and biological reactions as they unfold with unprecedented spatial and temporal resolution. A principal challenge in this pursuit involves the delivery of samples to the X-ray interaction point in such a way that produces data of the highest possible quality and with maximal efficiency. This is hampered by intrinsic constraints posed by the light source and operation within a beamline environment. For liquid samples, the solution typically involves some form of high-speed liquid jet, capable of keeping up with the rate of X-ray pulses. However, conventional jets are not ideal because of radiation-induced explosions of the jet, as well as their cylindrical geometry combined with the X-ray pointing instability of many beamlines which causes the interaction volume to differ for every pulse. This complicates data analysis and contributes to measurement errors. An alternative geometry is a liquid sheet jet which, with its constant thickness over large areas, eliminates the problems related to X-ray pointing. Since liquid sheets can be made very thin, the radiation-induced explosion is reduced, boosting their stability. These are especially attractive for experiments which benefit from small interaction volumes such as fluctuation X-ray scattering and several types of spectroscopy. Although their use has increased for soft X-ray applications in recent years, there has not yet been wide-scale adoption at XFELs. Here, gas-accelerated liquid sheet jet sample injection is demonstrated at the European XFEL SPB/SFX nano focus beamline. Its performance relative to a conventional liquid jet is evaluated and superior performance across several key factors has been found. This includes a thickness profile ranging from hundreds of nanometres to 60 nm, a fourfold increase in background stability and favorable radiation-induced explosion dynamics at high repetition rates up to 1.13 MHz. Its minute thickness also suggests that ultrafast single-particle solution scattering is a possibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanometer-Scale Acoustic Wave Packets Generated by Stochastic Core-Level Photoionization Events

We demonstrate that the absorption of femtosecond hard x-ray pulses excites quasispherical, high-amplitude, and high-wave-vector coherent acoustic phonon wave packets using an all hard-x-ray pump-probe scattering experiment. The time- and momentum-resolved diffuse scattering signal is consistent with an ensemble of 3D strain wave packets induced by the rapid electron cascade dynamics following photoionization at uncorrelated excitation centers. We quantify key parameters of this process, including the localization size of the stress field and the photon energy conversion efficiency into elastic energy. The parameters are determined by the photoelectron and Auger electron cascade dynamics, as well as the electron-phonon interaction. In particular, we obtain the localization size of the observed strain wave packet to be 1.5 and 2.5 nm for bulk SrTiO 3 and KTaO 3 single crystals, respectively. The results provide crucial information on the mechanism of x-ray energy deposition into matter and shed light on the shortest collective length scales accessible to coherent acoustic phonon generation using x-ray excitation. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

Reconciling the Different Apparent Decay Pathways for Iron(III) Tetraphenylporphyrin Chloride: Evidence for Excited State Branching

Detailed understanding of the photophysical properties of metalloporphyrins is key to rationally exploiting them in a variety of applications ranging from photocatalysis to opto-magnetics. Previous studies of the ferric-tetraphenylporphyrin chloride have provided contradictory descriptions of the excited state evolution. Optical transient-absorption suggested initial formation of a ππ* excited state, followed by ligand-to-metal charge-transfer (LMCT) from the porphyrin ring and then decay on the ∼2 ps time scale to a metal-centered excited state that had a lifetime of ∼15 ps. In contrast, femtosecond extreme ultraviolet transient-absorption at the Fe M 2,3 -edge, while agreeing on the initial formation of an LMCT state, found evidence that this decayed in ∼2 ps to the ground state. Here, we have used K-edge transient X-ray absorption and X-ray emission, together with time-resolved X-ray solution scattering to explore this system. Based on these data, we propose a new model, consistent with both the earlier and the current data, in which photoexcited FeTPPCl evolves through three different states on the LMCT manifold, with the ∼2 ps decay now seen to involve a branching between return to the ground state (∼70%) and formation of a long-lived LMCT state (∼30%).

Excited states↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Band emission↗

Epitaxial strain tuning of Er 3+ in ferroelectric thin films

Er 3+ color centers are promising candidates for quantum science and technology due to their long electron and nuclear spin coherence times, as well as their desirable emission wavelength. By selecting host materials with suitable, controllable properties, we introduce new parameters that can be used to tailor the Er 3+ emission spectrum. PbTiO 3 is a well-studied ferroelectric material with known methods of engineering different domain configurations through epitaxial strain. By distorting the structure of Er 3+ -doped PbTiO 3 thin films, we can manipulate the crystal fields around the Er 3+ dopant. This is resolved through changes in the Er 3+ resonant fluorescence spectra, tying the optical properties of the defect directly to the domain configurations of the ferroelectic matrix. Additionally, we are able to resolve a second set of peaks for films with in-plane ferroelectric polarization. We hypothesize these results to be due to either the Er 3+ substituting different sites of the PbTiO 3 crystal, differences in charges between the Er 3+ dopant and the original substituent ion, or selection rules. Systematically studying the relationship between the Er 3+ emission and the epitaxial strain of the ferroelectric matrix lays the pathway for future optical studies of spin manipulation by altering ferroelectric order parameters.

36 MATERIALS SCIENCE↗

Electron–Ion Covariance Reveals Geometry-Resolved Inner-Shell Spectra in CS 2 Photodissociation

The chemical shifts of inner-shell atomic orbitals are highly sensitive to chemical bonding and molecular structure. In evolving systems, however, the spectra of distinct molecular species and geometries overlap, obscuring the underlying chemical dynamics. Here we demonstrate the use of electron–ion covariance analysis to combine the structural sensitivity of Coulomb explosion imaging with inner-shell spectroscopy, yielding geometry-specific spectra of transient and product species. We apply this approach to the excited state dynamics of CS 2 probed by ionization above the S 2p edge. Electron–ion covariance with time- and momentum-selected S + and S 2+ ions isolates distinct S 2p photoelectron spectra for ground-state CS 2 , bent photoexcited CS 2 , the CS photoproduct, and bare atomic sulfur ─ species whose spectra overlap strongly in the channel-averaged measurement. Clear chemical shifts are observed in the covariance photoelectron spectrum for each of these species, all of which are consistent with high-level calculations. Here, by extracting the atomic S contribution to the photoelectron spectrum in a finely time-resolved manner we can disentangle this contribution to the overall time-resolved photoelectron spectrum as the photodissociation proceeds. These results demonstrate the promise of electron–ion covariance as a general approach to geometry-resolved inner-shell spectroscopy, opening a route to tracking structural evolution through chemical shifts in complex photoexcited molecules.

Ionization↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Electrolyte Vapor Induced Passivation and Transition Metal Redox on Electrode Active Materials

The gaseous environment that battery electrodes are exposed to is critical to their electrochemical performance, and yet, the impact of vapor-phase components in the glovebox is relatively unexplored. In this study, we examine how the surface of Li 4 Ti 5 O 12 and LiFePO 4 composite electrodes evolve upon exposure to 1 M LiPF 6 in ethylene carbonate:dimethyl carbonate electrolyte vapors in an argon-filled glovebox. Spatially resolved X-ray photoemission electron microscopy and X-ray photoelectron spectroscopy reveal that even brief (15 minutes) contact with electrolyte vapor initiates the formation of a LiF film and changes the oxidation state of transition metals at the particle surface. Notably, these modifications occur selectively on active material particles and not on binder or conductive carbon, underscoring the specificity of vapor-induced reactions. Prolonged exposure to electrolyte vapor over the course of 1 week yields thicker, more chemically complex interphases containing both LiF and lithium oxyfluorophosphate species (Li x PO y F z ). Subsequent electrochemical testing shows that vapor-induced passivation layers influence first cycle capacities, lithium (de)insertion overpotentials, and charge-transfer resistance values. In conclusion, these results indicate that vapor–electrode interactions may be a source of variability in electrochemical behavior over time and suggest that other, more reactive electrode materials may also be susceptible to interactions with electrolyte vapor.

36 MATERIALS SCIENCE↗

Angularly resolved spectral reconstruction of x rays via filter pack attenuation

We have designed a new filter pack array to measure angular variations in x-ray spectra during a single shot. The filter pack was composed of repeating identical columns of aluminum and copper filters of varying thicknesses. These columns were located at different positions to measure the spectrum at each corresponding angle. This array was utilized in an experiment to measure the energy evolution of betatron x rays in a laser wakefield accelerator by curving the wakefield with a transverse density gradient, streaking the x rays across the array in front of an x-ray charge-coupled device (CCD) camera. After subtracting the background and “flattening” the image to remove spatial nonuniformities, a critical energy was calculated for each position that produced the best agreement with the measured signal. There was a clear change in critical energy with angle, shedding light on the dynamics of the electrons that traveled through the accelerator. Furthermore, these angles correspond to distinct emission times, covering a timescale of tens of picoseconds. The filter pack was capable of recovering these angular details without the impact of errors introduced by shot-to-shot variability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗