Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tomography software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

138 records · Page 8

Three-Dimensional Imaging and Numerical Reconstruction of Graphite/Epoxy Composite Microstructure Based on Ultra-High Resolution X-Ray Computed Tomography

A combined experimental and computational study aimed at high-resolution 3D imaging, visualization, and numerical reconstruction of fiber-reinforced polymer microstructures at the fiber length scale is presented. To this end, a sample of graphite/epoxy composite was imaged at sub-micron resolution using a 3D X-ray computed tomography microscope. Next, a novel segmentation algorithm was developed, based on concepts adopted from computer vision and multi-target tracking, to detect and estimate, with high accuracy, the position of individual fibers in a volume of the imaged composite. In the current implementation, the segmentation algorithm was based on Global Nearest Neighbor data-association architecture, a Kalman filter estimator, and several novel algorithms for virtualfiber stitching, smoothing, and overlap removal. The segmentation algorithm was used on a sub-volume of the imaged composite, detecting 508 individual fibers. The segmentation data were qualitatively compared to the tomographic data, demonstrating high accuracy of the numerical reconstruction. Moreover, the data were used to quantify a) the relative distribution of individual-fiber cross sections within the imaged sub-volume, and b) the local fiber misorientation relative to the global fiber axis. Finally, the segmentation data were converted using commercially available finite element (FE) software to generate a detailed FE mesh of the composite volume. The methodology described herein demonstrates the feasibility of realizing an FE-based, virtual-testing framework for graphite/fiber composites at the constituent level.

Czabaj, M. W.↗

Renin-Angiotensin System (RAS) in Hematopoietic Stem/Progenitor Cells (HS/PC) Predicts Vaso-Reparative Dysfunction and Progression of Diabetic Retinopathy (DR)

Purpose: We tested the hypothesis that loss of angiotensin converting enzyme 2 (ACE2) within diabetic HS/PCs (Hematopoietic Stem/Progenitor Cells) would be detrimental to HS/PC reparative function, and alter their ability to contribute to vascular remodeling in human subjects and rodent models of DR (Diabetic Retinopathy). Methods: Subjects (n52) were recruited as controls (n13) or diabetics (n39) with either no DR, mild non-proliferative DR (NPDR), moderate NPDR, severe NPDR or proliferative DR (PDR). Fluorescein angiograms were analyzed using Vessel Generation Analysis (VESGEN) software in a cohort of subjects. CD34+ HS/PCs were isolated from peripheral blood. RAS (Renin-Angiotensin System) gene expression and migration was measured. Diabetic ACE2 knockout (KO)C57BL6-Ins2 (Akita) mice at 3, 6 and 9 months of diabetes were compared to age-matched controls. Bone marrow HS/PC populations were analyzed by flow cytometry and migration and proliferation studies performed. Results: ACE2 gene expression in human CD34+ cells from diabetics without DR was increased compared to controls (p0.0437). Mas receptor mRNA was also increased in diabetics without DR, but reduced with the onset of NPDR (p0.0002), suggesting a loss of compensation. DR was associated with CD34+ cell migratory dysfunction. By VESGEN analysis, vessel density measured by several confirming parameters in early NPDR (n3) was greater than in normal retina (n6) in both arteries and veins, which suggests active retinal remodeling. ACE2KO-Akita and Akita cohorts showed reduced retinal thickness by OCT (Optical Coherence Tomography) at 9 months of diabetes. Absence of ACE2 in 9-month Akita mice led to an accelerated increase in acellular capillaries compared to diabetic alone. Electroretinogram (ERG) in ACE2KO-Akita mice resulted in persistent deterioration of the neural retina. Reparative function studies showed that ACE2KO exacerbated diabetes-induced impairment of LK (Low Potassium) cell migration and proliferative functions as early as 3-month of diabetes (p0.0019). Conclusions: Retinopathy and adverse vascular remodeling in subjects with diabetes was associated with a loss of the protective arm of RAS in HS/PCs. Loss of ACE2 exacerbated vascular dysfunction in diabetic mice.

retina↗

Computing the effective elasticity of anisotropic porous media from X-ray computed micro-tomography images

Development and optimization of composite materials designed for thermal protection of NASA’s spacecraft requires the understanding of their physical response to high-enthalpy environments. To predict their macro-scale properties and behavior, high-fidelity 3D simulations are performed at the micro-scale on realistic representations of these composites. The digital micro-structures are generated either synthetically or through X-ray micro-tomography reconstructions. One of the main challenges in the prediction of heatshield material structural response is the computation of the effective elasticity of the fibrous composite, as well as the understanding of the deformation and stresses generated at the micro-scale. These are driven by the fiber layout within the micro-structure and the distribution of the infused matrix. In this effort, the micro-mechanical linear elastic behavior of fibrous ablators is modeled through the use of a numerical method based on the Multi-Point Stress Approximation (MPSA) finite volume scheme. The MPSA, a generalization of the more commonly used Multi-Point Flux Approximation (MPFA), was discussed in a previous presentation at the 15th USCCN and in reference. To predict the behavior of fibrous and woven architectures, algorithms that compute the local fiber orientation are used. The implementation of the MPSA was verified using analytical solutions, engineering test cases and compared against legacy Finite Element Analysis (FEA) software. The stress analysis models were then applied to real geometries used by NASA in thermal protection systems such as fibrous preforms and woven materials and the results were compared to experimental data.

Federico Semeraro↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Overview of the Digitization Workflow Post Image Acquisition of Apollo Lunar and Antarctic Meteorite Samples Using Agisoft Photoscan for the NASA 3D Astromaterials Virtual Samples Collection

The 3D Virtual Astromaterials Samples (3DVAS) collection is a multi-year funded project to create a digital database of sixty Apollo Lunar and Antarctic Meteorite samples following non-destructive documentation conservation protocols. After initial image processing, the photos are evaluated and processed using unique structure-from-motion photogrammetric techniques in a high performance modelling software designed to create a 3D model from 2D images: Agisoft Photoscan Pro. Agisoft Photoscan Pro uses image processing algorithms and techniques originating in computer vision to resolve 3D models for accurate and detailed visualization of a subject. The software provides a stepwise process that is tailored per model based on spatial and specular reflectance properties, for example. The process includes: photo alignment, creation of a dense point cloud, mesh, and finally texture. Photo alignment is dependent on model properties. The 3DVAS process requires a special rotation platform with calibrated photogrammetric targets, specific distance rotation protocols, and a contrasting background for alignment and scale accuracy. As a result of the photographic process, alignment will complete with two mirrored hemispheres that, in a sense, represent the 2D images overlapping to create a 3D model. Each dense point cloud is analyzed with provided statistical measures in a gradual selection process to eliminate outliers. The point cloud is reduced to include only data valuable to the final model. When a precise dense point cloud is achieved, a mesh and texture are applied. Each model is scaled with scale bar accuracies within 100 microns. Each sample has its own intimate process for modelling; there is no standard for the parameters required in the final creation of a high resolution model. By processing multiple samples, a skill is gained in practice to allow a close definition of the original sample and will result in the most detailed version of the sample shell. This process completes one-fifth of the 3DVAS protocol for providing accurate digital documentation. Each model shell is merged with X-ray Computed Tomography data to create a full volumetric sample. All 3DVAS data will be served on NASA's Astromaterials Acquisition and Curation website with an early subset of data available in 2019 and the 3D Virtual Astromaterials Samples Collection launch in 2020.

Thomas, Andi B.↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Experimental Results from the Thermal Energy Storage-2 (TES-2) Flight Experiment

Thermal Energy Storage-2 (TES-2) is a flight experiment that flew on the Space Shuttle Endeavour (STS-72), in January 1996. TES-2 originally flew with TES-1 as part of the OAST-2 Hitchhiker payload on the Space Shuttle Columbia (STS-62) in early 1994. The two experiments, TES-1 and TES-2 were identical except for the fluoride salts to be characterized. TES-1 provided data on lithium fluoride (LiF), TES-2 provided data on a fluoride eutectic (LiF/CaF2). Each experiment was a complex autonomous payload in a Get-Away-Special payload canister. TES-1 operated flawlessly for 22 hr. Results were reported in a paper entitled, Effect of Microgravity on Materials Undergoing Melting and Freezing-The TES Experiment, by David Namkoong et al. A software failure in TES-2 caused its shutdown after 4 sec of operation. TES-1 and 2 were the first experiments in a four experiment suite designed to provide data for understanding the long duration microgravity behavior of thermal energy storage salts that undergo repeated melting and freezing. Such data have never been obtained before and have direct application for the development of space-based solar dynamic (SD) power systems. These power systems will store energy in a thermal energy salt such as lithium fluoride or a eutectic of lithium fluoride/calcium difluoride. The stored energy is extracted during the shade portion of the orbit. This enables the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes were developed for predicting performance of a space-based solar dynamic power system. Experimental verification of the analytical predictions were needed prior to using the analytical results for future space power design applications. The four TES flight experiments were to be used to obtain the needed experimental data. This paper will address the flight results from the first and second experiments, TES-1 and 2, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code. An analysis of the TES-2 data was conducted by Cleveland State University Professor, Mounir Ibrahim. TESSIM validation was based on two types of results; temperature history of various points on the containment vessel and TES material distribution within the vessel upon return from flight. The TESSIM prediction showed close comparison with the flight data. Distribution of the TES material within the vessel was obtained by a tomography imaging process. The frozen TES material was concentrated toward the colder end of the canister. The TESSIM prediction indicated a similar pattern. With agreement between TESSIM and the flight data, a computerized representation was produced to show the movement and behavior of the void during the entire melting and freezing cycles.

Tolbert, Carol↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Updates to the Regional Seismic Travel Time (RSTT) Model: 2. Path-dependent Travel-time Uncertainty

Abstract The regional seismic travel time (RSTT) model and software were developed to improve travel-time prediction accuracy by accounting for three-dimensional crust and upper mantle structure. Travel-time uncertainty estimates are used in the process of associating seismic phases to events and to accurately calculate location uncertainty bounds (i.e. event location error ellipses). We improve on the current distance-dependent uncertainty parameterization for RSTT using a random effects model to estimate slowness (inverse velocity) uncertainty as a mean squared error for each model parameter. The random effects model separates the error between observed slowness and model predicted slowness into bias and random components. The path-specific travel-time uncertainty is calculated by integrating these mean squared errors along a seismic-phase ray path. We demonstrate that event location error ellipses computed for a 90% coverage ellipse metric (used by the Comprehensive Nuclear-Test-Ban Treaty Organization International Data Centre (IDC)), and using the path-specific travel-time uncertainty approach, are more representative (median 82.5% ellipse percentage) of true location error than error ellipses computed using distance-dependent travel-time uncertainties (median 70.1%). We also demonstrate measurable improvement in location uncertainties using the RSTT method compared to the current station correction approach used at the IDC (median 74.3% coverage ellipse).

58 GEOSCIENCES↗

Experimental Investigation of Pool Boiling Heat Transfer Enhancement in Microgravity in the Presence of Electric Fields

In boiling high heat fluxes are possible driven by relatively small temperature differences, which make its use increasingly attractive in aerospace applications. The objective of the research is to develop ways to overcome specific problems associated with boiling in the low gravity environment by substituting the buoyancy force with the electric force to enhance bubble removal from the heated surface. Previous studies indicate that in terrestrial applications nucleate boiling heat transfer can be increased by a factor of 50, as compared to values obtained for the same system without electric fields. The goal of our research is to experimentally explore the mechanisms responsible for EHD heat transfer enhancement in boiling in low gravity conditions, by visualizing the temperature distributions in the vicinity of the heated surface and around the bubble during boiling using real-time holographic interferometry (HI) combined with high-speed cinematography. In the first phase of the project the influence of the electric field on a single bubble is investigated. Pool boiling is simulated by injecting a single bubble through a nozzle into the subcooled liquid or into the thermal boundary layer developed along the flat heater surface. Since the exact location of bubble formation is known, the optical equipment can be aligned and focused accurately, which is an essential requirement for precision measurements of bubble shape, size and deformation, as well as the visualization of temperature fields by HI. The size of the bubble and the frequency of bubble departure can be controlled by suitable selection of nozzle diameter and mass flow rate of vapor. In this approach effects due to the presence of the electric field can be separated from effects caused by the temperature gradients in the thermal boundary layer. The influence of the thermal boundary layer can be investigated after activating the heater at a later stage of the research. For the visualization experiments a test cell was developed. All four vertical walls of the test cell are transparent, and they allow transillumination with laser light for visualization experiments by HI. The bottom electrode is a copper cylinder, which is electrically grounded. The copper block is heated with a resistive heater and it is equipped with 6 thermocouples that provide reference temperatures for the measurements with HI. The top electrode is a mesh electrode. Bubbles are injected with a syringe into the test cell through the bottom electrode. The working fluids presently used in the interferometric visualization experiments, water and PF 5052, satisfy requirements regarding thermophysical, optical and electrical properties. A 30kV power supply equipped with a voltmeter allows to apply the electric field to the electrodes during the experiments. The magnitude of the applied voltage can be adjusted either manually or through the LabVIEW data acquisition and control system connected to a PC. Temperatures of the heated block are recorded using type-T thermocouples, whose output is read by a data acquisition system. Images of the bubbles are recorded with 35mm photographic and 16mm high-speed cameras, scanned and analyzed using various software packages. Visualized temperature fields HI allows the visualization of temperature fields in the vicinity of bubbles during boiling in the form of fringes. Typical visualized temperature distributions around the air bubbles injected into the thermal boundary layer in PF5052 are shown. The temperature of the heated surface is 35 C. The temperature difference for a pair of fringes is approximately 0.05 C. The heat flux applied to the bottom surface is moderate, and the fringe patterns are regular. In the image a bubble penetrating the thermal boundary layer is visible. Because of the axial symmetry of the problem, simplified reconstruction techniques can be applied to recover the temperature field. The thermal plume developing above the heated surface for more intensive heating is shown. The temperature distribution in the liquid is clearly 3D, and tomographic techniques have to be applied to recover the temperature distribution in such a physical situation. A sequence of interferometric images showing the temperature distribution around the rising bubble, recorded with a high-speed camera is shown. Again, the temperature distribution is 3D, and a more complex approach to the evaluation, the tomographic reconstruction has to be taken. Measurement of the temperature distribution from the fringe pattern temperature distributions that yield important information regarding heat transfer are determined. Two algorithms that allow the quantitative evaluation of interferometric fringe patterns and the reconstruction of temperature fields during boiling have been developed at the Heat Transfer Laboratory of the Johns Hopkins University. In the first algorithm the bubble is assumed to be axially symmetrical, which significantly reduces the computational effort for quantifying the temperature distribution around the bubble. For this purpose the thermal boundary layer around the bubble is divided into equidistant concentric shells, and the refractive index is assumed to be constant in each of the shells. Since large temperature gradients are expected in the vicinity of the bubble during boiling, the deflection of the light beam cannot be neglected in boiling experiments. Since the exit angle of the light beam is known, this allows to account for the deflections and phase shifts outside the boundary layer (in the bulk fluid and in the windows of the test cell). Three dimensional temperature distributions in the vicinity of the bubble are reconstructed using tomographic techniques. In tomography, the measurement volume is sliced into 2D planes. In the present study these planes are parallel to the heated surface. The objective is to determine the values of the field parameter of interest in form of the field function in these 2D planes. The field parameter is the change of the refractive index of the liquid in the measurement volume caused by temperature changes. By superimposing data for many 2D planes recorded at the same time instant, the 3D temperature distribution in the measurement volume is recovered.

Herman, Cila↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Engineering a modular 44 Ti/ 44 Sc generator: eluate evaluation in preclinical models and estimation of human radiation dosimetry

Background: 44 Sc/ 47 Sc is an attractive theranostic pair for targeted in vivo positron emission tomographic (PET) imaging and beta-particle treatment of cancer. The 44 Ti/ 44 Sc generator allows daily onsite production of this diagnostic isotope, which may provide an attractive alternative for PET facilities that lack in-house irradiation capabilities. Early animal and patient studies have demonstrated the utility of 44 Sc. In our current study, we built and evaluated a novel clinical-scale 44 Ti/ 44 Sc generator, explored the pharmacokinetic profiles of 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA (1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid) in naïve mice, and estimated the radiation burden of 44 ScCl 3 in humans. Methods: 44 Ti/ 44 Sc (101.2 MBq) in 6 M HCl solution was utilized to assemble a modular ZR resin containing generator. After assembly, 44 Sc was eluted with 0.05 M HCl for further PET imaging and biodistribution studies in female Swiss Webster mice. Based on the biodistribution data, absorbed doses of 44 / 47 ScCl 3 in human adults were calculated for 18 organs and tissues using the IDAC-Dose software. Results: 44 Ti in 6 M HCl was loaded onto the organic resin generator with a yield of 99.97%. After loading and initial stabilization, 44 ScCl 3 was eluted with 0.05 M HCl in typical yields of 82.9 ± 5.3% (N = 16), which was normalized to the estimated generator capacity. Estimated generator capacity was computed based on elution time interval and the total amount of 44 Ti loaded on the generator. Run in forward and reverse directions, the 44 Sc/ 44 Ti ratio from a primary column was significantly improved from 1038 ± 440 to 3557 ± 680 (Bq/Bq) when a secondary, replaceable, ZR resin cartridge was employed at the flow outlet. In vivo imaging and ex vivo distribution studies of the reversible modular generator for 44 ScCl 3 , [ 44 Sc]-citrate and [ 44 Sc]-NODAGA show that free 44 Sc remained in the circulation significantly longer than the chelated 44 Sc. The dose estimation of 44 ScCl 3 reveals that the radiation burden is 0.146 mSv/MBq for a 70 kg adult male and 0.179 mSv/MBq for a 57 kg adult female. Liver, spleen and heart wall will receive the highest absorbed dose: 0.524, 0.502, and 0.303 mGy/MBq, respectively, for the adult male. Conclusions: A clinical-scale 44 Ti/ 44 Sc generator system with a modular design was developed to supply 44 ScCl 3 in 0.05 M HCl, which is suitable for further radiolabeling and in vivo use. Our data demonstrated that free 44 ScCl 3 remained in the circulation for extended periods, which resulted in approximately 10 times greater radiation burden than stably chelated 44 Sc. Stable 44 Sc/ 47 Sc-complexation will be more favorable for in vivo use and for clinical utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗