Search NASA⌕ Search

SEARCH · Search NASA

Results for “ULTRASONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Impurity gas monitoring using ultrasonic sensing and neural networks: forward and inverse problems

Ultrasonic sensing is a non-invasive technique for monitoring impurity gas composition in various industrial applications where safety and regulatory compliance are crucial. In this study, ultrasonic sensing and neural networks were used to analyze impurity gases (i.e., air and argon) in helium. An experimental platform was established to acquire ultrasonic data. In the forward problem, an artificial neural network (ANN) model was used to forecast the response and time-of-flight (TOF) based on the excitation, and argon and air concentrations. The inverse problem was solved using a convolutional neural network (CNN) to predict the argon and air concentrations given the ultrasonic response and excitation. The results showed that the ANN accurately predicted the ultrasonic response and the change in TOF with concentration. As the air concentration was increased from 0 to 9.8%, the TOF sensitivity to detect argon decreased by 39.8% and 16.1% from ANN and sound speed theory, respectively. The CNN demonstrated high accuracy in predicting concentrations for inputs in the testing dataset. The application of the trained CNN indicated that it over-predicts air concentration while under-predicting the argon concentration. To improve accuracy, the predicted air and argon concentrations should be corrected by -0.992% and 1.027% bias, respectively.

47 OTHER INSTRUMENTATION↗

Irradiation of ultrasonic sensors and adhesive couplants for application in light water reactor primary loop piping and components

The Electric Power Research Institute (EPRI) Nuclear Sector and US Department of Energy Light Water Reactor Sustainability Program are committed to engaging in research and development endeavors to address materials aging issues specific to long term operation of light water power reactors. To this effect, EPRI launched an industry initiative to develop nondestructive evaluation systems for online monitoring of existing cracks in light water reactor primary coolant loop piping and components. One of the goals of this initiative is to develop a sensor system (or systems) that can determine nondestructively if cracks are growing or arrested and, in the case of the former, to characterize their growth rates. A missing component of this initiative is an experimental assessment of how sensors and adhesive couplants will perform in service when exposed to chronic energetic neutron radiation, particularly at the primary coolant loop hot and cold leg dissimilar metal welds, which join the primary loop piping to the reactor pressure vessel and reside in the vicinity of the reactor core. The objective of this experimental study was to determine how ultrasonic transducers and adhesive couplants perform when exposed to irradiation in a test reactor to simulate and accelerate in-service exposure. Further, to achieve this objective, the signal stability of piezoelectric transducers and performance of adhesive couplants as a function of accumulated fast neutron fluence were characterized by collecting ultrasonic data in-situ during irradiation. Of particular interest were the ultrasonic signal quality and time decay of the amplitude of acoustic reflections as a function of fast neutron fluence. The results of the study showed that, of the 8 transducer/substrate sample assemblies tested, only 3 generated usable ultrasonic signals through the conclusion of the irradiation campaign. It was found that high temperature epoxy tends to ultrasonically couple the sensors to the substrates better than three types of refractory ceramic cements studied, as is supported by post irradiation examination. The results obtained through this experimental study will be utilized in the achievement of the overall goal of development of a sensor system to perform online monitoring of primary loop components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Recycling of indium from waste LCD: A promising non-crushing leaching with the aid of ultrasonic wave

Highlights: • Indium is leached with the non-crushing method that simplifies the leaching process and reduces the leaching of impurities. • With enhancement of ultrasonic wave, indium containing in waste LCDs can be leached efficiently even at room temperature. • The mechanism of influence of ultrasonic waves is analyzed combining with the micro-structure of ITO-glass. - Abstract: The tremendous amount of end-of-life liquid crystal displays (LCDs) has become one of the prominent sources of waste electrical and electronic equipment (WEEE) in recent years. Despite the necessity of safe treatment, recycling indium is also a focus of waste LCD treatment because of the scarcity of indium. Based on the analyses of the structure of Indium Tin Oxide (ITO) glass, crushing is demonstrated to be not required. In the present research, a complete non-crushing leaching method was firstly adopted to recycle indium from waste LCDs, and the ultrasonic waves was applied in the leaching process. The results demonstrated that indium can be leached efficiently with even a low concentration of chloride acid (HCl) without extra heating. About 96.80% can be recovered in 60 mins, when the ITO glass was leached by 0.8 M HCl with an enhancement of 300 W ultrasonic waves. The indium leaching process is abridged free from crushing, and proves to be of higher efficiency. In addition, the ultrasonic wave influence on leaching process was also explained combing with micron-scale structure of ITO glass.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrasonic-Assisted Extrusion Processing for Enhancing Physical Properties of High-Density Polyethylene by Flow-Induced Crystallization

The evolution of crystallinity resulting from stress imposed on a melt, known as flow-induced crystallinity, can strongly influence the mechanical and physical properties of semicrystalline polymers. This study investigates shear-induced crystallization by applying an ultrasonic field to the melt flow as it passes through dies with various geometries. A custom-built sonication die is employed for controlling the dynamic temperature and shear environment, resulting in molecular alignment and potential for flow-induced crystallization. Application of both conventional and ultrasonic shear rates at the equilibrium melt temperature of high-density polyethylene (HDPE) was investigated to accelerate crystallinity and manipulate the crystal morphology across the film in pursuit of improved mechanical and gas barrier properties without the need for additives or other polymer layers. The relationships among ultrasonic-assisted extrusion processing, polymer structure, and performance were analyzed using wide- and small-angle X-ray scattering (WAXS and SAXS), tensile testing, and oxygen transmission rate (OTR) analysis. Multiple linear regression models were implemented to predict the correlation among HDPE structure, process, and properties. Structural analysis revealed that both conventional and ultrasonic shear rates had the most significant influence on lamellar spacing and redistribution of rigid and soft amorphous fractions within the crystalline domains, ultimately dictating the mechanical and physical properties of the films. The goal is to explore the potential of the ultrasonic-assisted high crystallinity monolayer that can replace some of the functionality of complex, heterogeneous multilayer packaging with a single-material film having enhanced oxygen barrier properties.

crystallinity↗

Influence Of Ultrasonic Waves On The Formation Of High Pores Silicon Carbide

The Challenge to produce a quality Silicon Carbide that combination high surface area is promising and this material can be used in many application such as Hydrogen storage materials. Synthesis of high surface area carbon materials by selective etching of Silicon Carbide with choric acid while exposing ultrasonic wave have been made.Powder Of Sic (surface area 17.8 m{sup 2}/g) was treated in the chloric acetic as well as their mixture of various compositions and various time exposure of ultrasonic waves. Surface area and pore size can be controlled by temperature and concentration composition of Chloric and time exposure of ultrasonic wave.The resultant carbon and carbon-silicon carbide composite powders were characterized X-ray diffraction and Electron microscope. To determine a conversion degree of silicon carbide due to influence of the ultrasonic wave, the samples were annealed in open air at 1000 deg. C. There by carbon component of the carbon/silicon carbide composite was completely oxidized. The analysis of the samples shows the strong influence of time exposure of ultrasonic waves on the formation of pores.

36 MATERIALS SCIENCE↗

Studies on Laser Generated Ultrasonic Waves in Inconel Super Alloy

This paper deals with the generation, characterization and analysis of ultrasonic waves generated in a thick stepped sample of inconel super alloy using Laser Based Ultrasonic Technique. Nd-YAG pulsed laser is used for ultrasonic generation while He-Ne laser is used for heterodyne detection. Ultrasonic signals are analyzed using Fourier and wavelet transforms. Here the identification and estimation of velocity of pressure waves is presented. The mechanism of pressure wave generation is discussed in brief. Laser ultrasonics studies of inconel are being reported for the first time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical mechanisms of megahertz vibrations and nonlinear detection in ultrasonic force and related microscopies

Use of high frequency (HF) vibrations at MHz frequencies in Atomic Force Microscopy (AFM) advanced nanoscale property mapping to video rates, allowed use of cantilever dynamics for mapping nanomechanical properties of stiff materials, sensing μs time scale phenomena in nanostructures, and enabled detection of subsurface features with nanoscale resolution. All of these methods critically depend on the generally poor characterized HF behaviour of AFM cantilevers in contact with a studied sample, spatial and frequency response of piezotransducers, and transfer of ultrasonic vibrations between the probe and a specimen. Focusing particularly on Ultrasonic Force Microscopy (UFM), this work is also applicable to waveguide UFM, heterodyne force microscopy, and near-field holographic microscopy, all methods that exploit nonlinear tip-surface force interactions at high frequencies. Leveraging automated multidimensional measurements, spectroscopic UFM (sUFM) is introduced to investigate a range of common experimental parameters, including piezotransducer excitation frequency, probed position, ultrasonic amplitude, cantilever geometry, spring constant, and normal force. Consistent with studies of influence of each of these factors, the data-rich sUFM signatures allow efficient optimization of ultrasonic-AFM based measurements, leading to best practices recommendations of using longer cantilevers with lower fundamental resonance, while at the same time increasing the central frequency of HF piezo-actuators, and only comparing results within areas on the order of few μm{sup 2} unless calibrated directly or compared with in-the-imaged area standards. Diverse materials such as Si, Cr, and photoresist are specifically investigated. This work thereby provides essential insight into the reliable use of MHz vibrations with AFM and provides direct evidence substantiating phenomena such as sensitivity to adhesion, diminished friction for certain ultrasonic conditions, and the particular benefit of UFM and related methods for nanoscale mapping of stiff materials.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ultrasonic power measurement system based on acousto-optic interaction

Ultrasonic waves are widely used, with applications including the medical, military, and chemical fields. However, there are currently no effective methods for ultrasonic power measurement. Previously, ultrasonic power measurement has been reliant on mechanical methods such as hydrophones and radiation force balances. This paper deals with ultrasonic power measurement based on an unconventional method: acousto-optic interaction. Compared with mechanical methods, the optical method has a greater ability to resist interference and also has reduced environmental requirements. Therefore, this paper begins with an experimental determination of the acoustic power in water contained in a glass tank using a set of optical devices. Because the light intensity of the diffraction image generated by acousto-optic interaction contains the required ultrasonic power information, specific software was written to extract the light intensity information from the image through a combination of filtering, binarization, contour extraction, and other image processing operations. The power value can then be obtained rapidly by processing the diffraction image using a computer. The results of this work show that the optical method offers advantages that include accuracy, speed, and a noncontact measurement method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Piezo-Antenna: An Electromagnetic-Ultrasonic Data Transfer System

Electronic systems contained within sealed metallic enclosures, such as nuclear waste containers where wire penetration is not an option, require a through-wall data transfer technology to communicate. One such technology utilizes piezoelectric ultrasonic transducers to communicate through the barrier using elastic waves. Currently demonstrated ultrasonic through-wall data communication techniques have relied on having a direct interface with the ultrasonic transducers on either side. Here, this work studies the coupling of an antenna to such an ultrasonic communication system. A computationally efficient model of a piezobarrier ultrasonic communication system and antenna using a simplified antenna model and a transfer matrix piezobarrier model is utilized to perform a representative parameter space search. The system efficiency and bandwidth trends are shown for the system parameters as well as operating frequency. The tradeoff between efficiency and bandwidth is also presented. A system configuration within the parameter space is fabricated and demonstrated to achieve a data rate of up to 100 kb/s.

Antenna↗

Transmission of Images With Ultrasonic Elastic Shear Waves on a Metallic Pipe Using Amplitude Shift Keying Protocol

Transmission of information using ultrasonic elastic waves on existing metallic pipes provides an alternative communication option across physical barriers in a highly partitioned industrial complex, such as a nuclear facility. This work investigates the feasibility of the transmission of digital images over metallic pipes. Ultrasonic communication systems for transmission of images on a nuclear-grade stainless steel pipe were assembled for bench-scale demonstration. Information carriers in this system are refracted shear waves transmitted and received with piezoelectric transducers (PZTs) operating at 2-MHz nominal frequency. The refraction and propagation of ultrasonic shear waves were modeled with COMSOL software. An amplitude shift keying (ASK) communication protocol for image transmission was developed and implemented in the GNURadio software-defined radio (SDR) environment. Digital information was converted to analog ultrasonic signals using Red Pitaya electronic boards. The performance of the ASK protocol is evaluated at the output of every block in the GNURadio program by monitoring the transmission of select characters. Using the ASK communication protocol, the transmission of the 32-KB image was demonstrated at 2-Kbps bitrate across 6-ft-long stainless steel pipe. Finally, preliminary evaluation of ultrasonic communication on the piping of a nuclear facility, such as signal transmission on bent pipes, was performed with COMSOL computer simulations.

42 ENGINEERING↗

Development of a Versatile Ultrasonic Internal Pipe/Vessel Component Monitor for In-Service Inspection of Nuclear Reactor Components

The stated goal of this work was to develop a versatile system which could accurately measure vessel and valve internal vibrations and cavitation formation under in-service conditions in nuclear power plants, ultrasonically. The developed technology will benefit the nuclear power generation industry by allowing plant operators to monitor valve and vessel internals during operation. This will help reduce planned outages and plant component failures. During the course of this work, Structural Integrity Associates, Inc. gathered information from industry experts that target vibration amplitudes to be detected should be in the range of 0.001-in to 0.005-in (0.025-mm to 0.127-mm) and target vibration frequency ranges which should be detected were found to be between 0-Hz and 300-Hz. During the performed work, an ultrasonic measuring system was developed which utilized ultrasonic pulse-echo time-of-flight measurements to measure vibration frequency and amplitude. The developed system has been shown to be able to measure vibration amplitudes as low as 0.0008-in (0.020-mm) with vibration frequencies in the range of 17-Hz to 1000-Hz. Therefore, the developed system was able to meet the industry needs for vibration measurement. The developed ultrasonic system was also to be able to measure cavitation formation by monitoring the received ultrasonic time- and frequency-domain signals. This work also demonstrated the survivability of commercially available probes at temperatures up to 300-F for several weeks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Large Area Detection of Microstructural Defects with Multi-Mode Ultrasonic Signals

Cyclic loading or other stresses can lead to development of cracks and crack growth in mechanical structures, leading to eventual failure. While ultrasound imaging can be used for non-destructive testing of such structures, conventional ultrasound techniques are often limited by crack size, density, and areal coverage. An effective characterization of real-world, large-area structures is required at an early damage stage to prevent catastrophic failure and predict remaining life. In this study, a new nonlinear ultrasonic testing (NUT) method is proposed for large-area monitoring of practical structures with arbitrary complexity by using multiple-mode guided-wave ultrasonic signals. The proposed guided-wave NUT technique requires single-element transducers, simple electronics, and a mixed time-frequency domain signal processing. As a proof-of-concept demonstration, numerical simulations and experiments are performed on an A36 carbon steel beam assembly with previously formed microstructural defects that cause nonlinearities in ultrasonic response. The quadratic dependence of the nonlinear wave excitation on the input ultrasonic signal amplitude is shown by numerical simulations, and such a nonlinear ultrasonic response is experimentally observed in the zone with a high density of microstructural defects.

36 MATERIALS SCIENCE↗

Numerical Simulation Studies of Ultrasonic De-Icing for Heating, Ventilation, Air Conditioning, and Refrigeration Structures

Ice accumulation on heating, ventilation, air conditioning, and refrigeration (HVACR) structures presents significant operational challenges. These challenges include reduced efficiency, increased energy consumption, and potential damage to equipment. Traditional de-icing methods, such as chemical treatments, mechanical scraping, or heating-based techniques, are often labor-intensive, costly, and environmentally harmful. Here, this study uniquely investigates ultrasonic de-icing as an energy-efficient alternative for HVACR applications, focusing on the specific structural geometries found in these systems. A comprehensive numerical simulation framework was developed using finite element analysis to explore ultrasonic wave propagation across four distinct HVACR structures. Key parameters such as ultrasonic frequency, power levels, and the number and placement of actuators were examined for their impact on ice detachment efficiency. Results from simulations on a plate structure reveal that ultrasonic excitation can propagate effectively across large areas (at least 150 × 150 mm), enhancing the de-icing coverage. Lower frequency (e.g., 30 to 45 kHz) excitation results in greater displacement, improving de-icing performance, while increased actuator numbers with the same total power input also enhance effectiveness. Two actuators seem sufficient for the de-icing of a 300 × 300 mm plate. For tube-and-fin structures, specific high-power ultrasonic frequencies selectively excite the fin plates, demonstrating efficient ice removal when actuated on the tube. However, optimal performance requires careful design of actuator placement and vibration modes to accommodate the irregular shapes of these structures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porosity Prediction and Detection During Composite Cure Using Simulation and Ultrasonic In-Situ Inspection Inside and Autoclave

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which are currently identified using post-manufacturing inspection methods. A cure defects process model has been developed to predict the formation of manufacturing defects (e.g., porosity and fiber waviness) in composites based on the cure parameters and part geometry. However, a capability to directly validate porosity during cure did not exist. Validation methods included comparing resin pressure measured during cure with predictions by the process model and inspection/microscopy after cure. This study developed a high-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure and experimentally verify the predictions of the model. The system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen(LN2) injections. A high-temperature 2.25 MHz ultrasonic transducer was utilized to transmit ultrasonic waves through the tool plate and into the composite material and to measure the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. These observations matched the predictions of the model using the inputs from the experiment (e.g., part material and geometry, cure cycle) and were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide defect detection and localization and can be applied to future manufacturing of composite structure for aerospace applications.

Porosity↗

Porosity Detection and Localization During Composite Cure Inside an Autoclave Using Ultrasonic Inspection

Composite materials offer unique benefits in aerospace applications such as increased strength-to-weight ratio and improved fatigue properties. They are increasingly being used in major commercial aircraft programs. However, current processing methods can lead to defects in composite parts, which must be detected using post-manufacturing inspection methods. Porosity (i.e., pores, voids) is a critical defect from the cure process that is detrimental to performance of the composite part. It is therefore necessary to understand and eliminate the formation of porosity defects. At NASA Langley Research Center, an in-situ cure monitoring system was developed to detect porosity defects as they form in real-time inside an autoclave. A capability to directly detect and localize porosity within a composite during cure did not exist before. This study is focused on an elevated-temperature ultrasonic inspection system to detect porosity defects in composites during autoclave cure. The ultrasonic inspection system operated inside an autoclave within an enclosure cooled by intermittent liquid nitrogen (LN_2) injections. A high-temperature, 2.25 MHz, transducer transmitted ultrasonic waves through the tool plate and into the composite part and measured the amplitude and time of flight of the reflected waves with a 1 mm × 1 mm step size/areal resolution. Porosity was observed via the ultrasonic reflections, which experienced increased attenuation in regions of high porosity. Distinct regions of increased porosity were present due to uneven pressure across the panel, which was driven by an intentional misfit between the flat caul plate and the tapered composite panel with ply drops. The results were validated by post-cure ultrasonic inspection and micrographs. The in-situ inspection system was able to successfully provide porosity detection and localization in the tapered ply-drop panel. The successful results indicate the promise of this system for future implementation in the manufacturing of composite structures for aerospace applications.

Composites↗

Application of Compressed Sensing to 2-D Ultrasonic Propagation Imaging System data

The Ultrasonic Propagation Imaging (UPI) System is a unique, non-contact, laser-based ultrasonic excitation and measurement system developed for structural health monitoring applications. The UPI system imparts laser-induced ultrasonic excitations at user-defined locations on a structure of interest. The response of these excitations is then measured by piezoelectric transducers. By using appropriate data reconstruction techniques, a time-evolving image of the response can be generated. A representative measurement of a plate might contain 800x800 spatial data measurement locations and each measurement location might be sampled at 500 instances in time. The result is a total of 640,000 measurement locations and 320,000,000 unique measurements. This is clearly a very large set of data to collect, store in memory and process. The value of these ultrasonic response images for structural health monitoring applications makes tackling these challenges worthwhile. Recently compressed sensing has presented itself as a candidate solution for directly collecting relevant information from sparse, high-dimensional measurements. The main idea behind compressed sensing is that by directly collecting a relatively small number of coefficients it is possible to reconstruct the original measurement. The coefficients are obtained from linear combinations of (what would have been the original direct) measurements. Often compressed sensing research is simulated by generating compressed coefficients from conventionally collected measurements. The simulation approach is necessary because the direct collection of compressed coefficients often requires compressed sensing analog front-ends that are currently not commercially available. The ability of the UPI system to make measurements at user-defined locations presents a unique capability on which compressed measurement techniques may be directly applied. The application of compressed sensing techniques on this data holds the potential to reduce the number of required measurement locations, reduce the time to make measurements, reduce the memory required to store the measurements, and possibly reduce the computational burden to classify the measurements. This work considers the appropriate selection of the signal dictionary used for signal reconstruction, and performs an evaluation of compressed sensing technique's ability to reconstruct ultrasonic images using fewer measurements than would be needed using traditional Nyquist-limited data collection techniques.

42 ENGINEERING↗

Ultrasonic Communication Systems for Data Transmission

Ultrasonic signals are widely used in the field of medical imaging and industrial nondestructive testing. Ultrasonic wave can propagate through solid, liquid or gas media and consequently can be used as the carrier of the information for communications. In this paper, we examine the feasibility of using the ultrasonic signal for communication in solid media. Characteristic of ultrasonic waves in the solid channel are studied and an FPGA based platform is designed for software-defined digital and packet communications. Experimental results are presented and analyzed to demonstrate the feasibility of using ultrasonic guided waves for digital communication in solid channels such as metal plates.

I/Q modulation↗

Experimental and numerical validation of an ultrasonic visualization system for nuclear reactor application

This paper deals with the design of ultrasonic imaging systems for the next generation of nuclear reactors cooled by liquid metal. Indeed, a generation IV research nuclear reactor is being developed by the Belgian Nuclear Research Center (SCK-CEN) in the frame of the MYRRHA project (for Multipurpose hYbrid Research Reactor for High-tech Applications). This sub-critical/critical reactor is cooled by Lead-Bismuth Eutectic (LBE). The opacity of this liquid metal requires the development of an ultrasonic visualization system for internal inspection and object detection. But due to the peculiar conditions met in the core of the reactor, velocity as well as temperature gradients are expected and are likely to affect directly the ultrasonic propagation. The objective of this work is to validate the ultrasonic imaging strategy by tests performed in a dedicated test rig and by numerical simulations using a ray-tracing method. The experimental investigations have been performed on a specific water facility reproducing conditions similar to those encountered in the core of the MYRRHA reactor. These conditions include the propagation over large distance, and the presence of temperature and velocity gradients. In the MYRRHA reactor application, the distance to be travelled by the acoustic waves of the visualization system is about 5 m, including a reflection. The acoustic absorption, the scattering losses, the beam divergence and the transmitted energy during reflection have been determined as a function of the travelled distance. The experimental values are compared with the literature for validation. The presence of temperature and velocity gradients in the core of the reactor is due to the coolant circulation. These gradients are about 5 K over 0.1 m and 1 m/s over 0.2 m, respectively, and are reproduced in the facility for investigating their influence on the propagation of ultrasounds. The experimental data are used for improving and validating a ray-tracing algorithm. This algorithm is then applied to the full scale application for validating the ultrasonic visualization system for nuclear reactor application. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗