Search NASA⌕ Search

SEARCH · Search NASA

Results for “URINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of Low-Toxicity Urine Stabilization for Spacecraft Water Recovery Systems

Wastewater stabilization is an essential component of the spacecraft water cycle. The purpose of stabilizing wastewater is two-fold. First, stabilization prevents the breakdown of urea into ammonia, a toxic gas at high concentrations. Second, it prevents the growth of microorganisms, thereby mitigating hardware and water quality issues due to due biofilm and planktonic growth. Current stabilization techniques involve oxidizers and strong acids (pH=2) such as chromic and sulfuric acid, which are highly toxic and pose a risk to crew health. The purpose of this effort is to explore less toxic stabilization techniques, such as food-grade and commercial care preservatives. Additionally, certain preservatives were tested in the presence of a low-toxicity organic acid. Triplicate 300-mL volumes of urine were dosed with a predetermined quantity of stabilizer and stored for two weeks. During that time, pH, total organic carbon (TOC), ammonia, and turbidity were monitored. Those preservatives that showed the lowest visible microbial growth and stable pH were further tested in a six-month stability study. The results of the six-month study are also included in this paper.

Adam, Niklas↗

Urine Removal from Suited Crew in Orion Vehicle Depressurization Scenario

Humankind wants to continually venture deeper into space, but there are many hazards of deep space exploration. NASA’s Orion Program seeks to incrementally identify these hazards and begin addressing the difficulties of such long-duration missions. One of the largest risks and areas of program focus is crew survival in a vehicle cabin depressurization scenario. As part of proactive mitigation efforts, contingency operations and associated hardware are being developed to sustain crew members for up to 6 days. While the Orion launch and entry suit would provide the crew a pressurized safe haven for that duration, additional systems are needed to handle crew waste while within the suit. NASA’s Orion Crew Survival Systems (OCSS) and Collins Aerospace are working together to develop and test an external suit system to aid in the evacuation of urine from pressurized suits to ensure crew health and safety. This paper describes the recent and on-going design and testing that is driving evolution of hardware and requirements towards eventual flight certification.

OCSS↗

Standard research materials: Feces and urine

Preparation of the standard research materials, preparation of the samples for analysis, elemental analysis, composition of standard research materials, and methodology are discussed.

Source record↗

Prosthetic Sphincter Controls Urination

People who lost muscular control of urinary canal through disease or injury aided by prosthetic sphincter. Implanted so it surrounds uretha, sphincter deflated and inflated at will by wearer to start and stop urina tion. Operating pressure adjusted after implantation to accommodate growth or atrophy of urinary canal and prevent tissue damage from excess pressure. Principle adapted to other organs, such as colon, ureter, or ileum.

Tenny, John B., Jr↗

Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine

An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials with an Investigative New Drug (IND). The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial with INSCOP.

Wu, L.↗

Passive, Collapsible Contingency Urinal for Human Space Flight

Fluid transport systems for spacecraft face acute challenges because of the persistently unfamiliar and unforgiving low-gravity environment. IRPI, LLC, has developed a contingency wastewater collection and processing device that provides passive liquid collation, containment, bubble separation, and droplet coalescence functions. The lightweight, low-volume, low-cost, and potentially disposable device may be used for subsequent sampling, metering, storage, disposal, and/or reuse. The approach includes a fractal wetting design that incorporates smart capillary fluidics. This work could have a broad impact on capillary-based fluid management on spacecraft and on Earth.

Jenson, Ryan↗

A Fast, Accurate and Sensitive GC-FID Method for the Analyses of Glycols in Water and Urine

Glycols, specifically ethylene glycol and 1,2-propanediol, are some of the major organic compounds found in the humidity condensate samples collected on the International Space Station. The current analytical method for glycols is a GC/MS method with direct sample injection. This method is simple and fast, but it is not very sensitive. Reporting limits for ethylene glycol and 1,2-propanediol are only 1 ppm. A much more sensitive GC/FID method was developed, in which glycols were derivatized with benzoyl chloride for 10 minutes before being extracted with hexane. Using 1,3-propanediol as an internal standard, the detection limits for the GC/FID method was determined to be 50 ppb and the analysis only takes 7 minutes. Data from the GC/MS and the new GC/FID methods shows excellent agreement with each other. Factors affecting the sensitivity, including sample volume, NaOH concentration and volume, volume of benzoyl chloride, reaction time and temperature, were investigated. Interferences during derivatization and possible method to reduce interferences were also investigated.

Kuo, C. Mike↗