Q-value (MeV/fission) Determination for the Advanced Test Reactor

This report documents a step-by-step procedure that can be used to calculate a Q-value for the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The Q-value calculation here is an estimate of the total energy released per fission event in the ATR driver fuel in units of MeV/fission and is recognized as a reactor-specific Q-value for the ATR. Such a Q-value is needed INL ATR reactor physicists to normalize calculated fluxes and reaction rates to measured ATR total core and lobe powers. The calculated ATR Q-value and the procedure used to calculate this value are presented in a detailed manner so as to establish a credible basis, such that this single Q-value can be used consistently among all ATR reactor physicists. A Q-value is essentially the summation of all the kinetic energy from all radiation components released from a single fission event that ends up as heat in the reactor coolant. Estimation of a Q-value for a given reactor can theoretically be very complex because it is dependent on several variables, which include (1) the materials in the reactor core, (2) the neutron energy spectrum, and (3) the mix of actinide isotopes that are being simultaneously fissioned. Since these three variables can potentially change over time or with reactor burnup, this potentially makes the Q-value a time-dependent quantity. However, for ATR, we will invoke some simplifying assumptions, based on the unique features of the ATR core and supported by neutronic calculations, which will reduce the complexity of the problem and lead to a single time-independent Q-value. Of the three variables, the materials in the core have the greatest impact on the ATR Q-value. Since the materials in the core are most important, an array of components (materials) have been carefully selected to compose a typical ATR core configuration. It should be noted that the step-by-step procedure here for calculating a reactor-specific Q-value can be applied to any nuclear reactor. In a more general procedure, if one needed to include time-dependent spectral and actinide composition changes as a function of burnup for a specific reactor, this procedure can still be used, but at discrete time steps throughout the burnup. The result will be a set of discrete Q-values as a function of burnup. However, here we will apply the procedure to the ATR, as an example, and obtain a single Q-value that is valid for the ATR reactor as a function of burnup. In the evaluated nuclear data file (ENDF), Q-values for specific actinides are known for a reasonably high degree of accuracy, especially the major uranium and plutonium isotopes. The isotopic Q-values are composed of the kinetic energy of the fission fragments and the energies of the various radiation components emitted from the fission event. One complication is the fact that some of these energy components are dependent on the incident neutron energy (EINC) that induces the fission event (neutron energy spectrum dependence). For ATR, we will estimate an average neutron energy based on the neutron energy flux weighted by the fission cross sections and use this average neutron energy value in the ENDF formulas. This neutron energy dependence is one of two dependencies that make the final ATR Q-value a reactor-specific value. The second dependency, and the most important variable for ATR, involves the materials in the core and the de-excitation radiations produced from neutron radiative capture radiation; radiation energy that becomes heat in the reactor coolant. This important dependency is discussed in detail below. The third dependency, or the mix of fissioning actinides as a function of ATR burnup, is ignored because the bulk of the fissions over a cycle are always due to U-235 in the high-enriched ATR core. In a fission event, the fission energy is partitioned between the fission fragments and the radiation components that include neutrons, gamma rays, and beta particles. The main variable that makes the calculated Q-value reactor-specific is the amount of radiative capture energy produced in the core due to prompt and delayed neutron capture in the reactor core materials and the subsequent release of nuclear binding energy in the form of de-excitation gamma radiation energy in the reactor core. This energy component, neutron radiative capture energy, is not in the ENDF, because it depends on the reactor and its core materials. The radiative capture gamma energy release can be significant, or approximately 3–12 MeV/fission depending on the materials in the reactor core (fuel materials, cladding, structural components, coolant, targets, reflector, etc.). For the ATR, the energy released from radiative capture gamma radiation is calculated to be near the middle of the 3–12 MeV range. This makes the radiative capture radiation component an important and significant contribution to the total ATR Q-value. The ATR has unique reactor features that will allow us to simplify the complex procedure for determining an ATR reactor-specific Q-value. For example, the ATR is a thermal reactor and contains high-enriched fuel (93.15 wt% U-235). Consequently, the bulk of the fissions in the ATR core from beginning-of-cycle (BOC) to end-of-cycle are from U-235. Even though U-238 makes up approximately 7% of the uranium atoms in the fuel, the number of fissions relative to U-235 is insignificant, since U-238 is fertile and ATR is a thermal reactor. The same is true for U-234 and U-236 (both fertile). The ATR’s high-enriched uranium fuel also inhibits the buildup of large quantities of plutonium isotopes. So, even though there is some buildup of U-236, Np-237, and Pu-239 in the ATR driver fuel, the impact or contribution of these isotopes fissions on the ATR Q-value is minor compared to U-235. Nonetheless, we will include fission contributions from all the major uranium isotopes (U-234, U-235, U-236, and U-238) in the determination of an average isotopic Q-value that is used in the ATR Q-value determination. Although the ATR Q-value calculated here is based on BOC conditions (fresh fuel with no higher order actinide buildup), it is believed that the ATR Q-value is relatively constant with burnup or during any given ATR power cycle (14–60 days). The reason is that the vast majority of the core driver fuel fissions are always from U-235 during the cycle. Also, since we effectively assume instantaneous energy release for the fission product gammas and beta particles and delayed neutrons from a fission event, this corresponds to equilibrium conditions for all fission product concentrations in the ATR driver fuel too. The goal of this effort was to determine a specific numerical and core-average Q-value for the recoverable energy released by a single fission event (MeV/fission) for the ATR. This calculated value has the potential to help standardize and add credibility to not only the Monte Carlo tally normalization process used by many ATR core physics analysts, but also to the normalization process for all reactor physics calculation methods involving ATR analyses. Currently, the ATR core physics analysts use slightly different Q-values. Some values are known to be conservative for specific applications. However, sometimes a more accurate Q-value is needed for the calculation in which ATR test specimens require non-conservative and as-accurate-as-possible Q-values to estimate burnups, heat rates, neutron fluxes, nuclear reaction rates, etc., where corresponding measured post-irradiation examination data provides the ultimate validation for the calculated results. A detailed Q-value procedure was developed and is outlined in this document along with numerical values calculated specifically for the determination of the ATR Q-value. This report attempts to document in some detail the calculation methodology, nuclear data, computer code, computer model, code calculated results, hand calculations, assumptions, and logic that went into the determination of the ATR Q-value.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

We estimate the long-run economic value of variable renewable generation with increasing penetration using a unique investment and dispatch model that captures long-run investment decisions while also incorporating detailed operational constraints and hourly time resolution over a full year. High time resolution and the incorporation of operational constraints are important for estimating the economic value of variable generation, as is the use of a modeling framework that accommodates new investment decisions. The model is herein applied with a case study that is loosely based on California in 2030. Increasing amounts of wind, photovoltaics (PV), and concentrating solar power (CSP) with and without thermal energy storage (TES) are added one at a time. The marginal economic value of these renewable energy sources is estimated and then decomposed into capacity value, energy value, day-ahead forecast error cost, and ancillary services. The marginal economic value, as defined here, is primarily based on the combination of avoided capital investment cost and avoided variable fuel and operations and maintenance costs from other power plants in the power system. Though the model only captures a subset of the benefits and costs of renewable energy, it nonetheless provides unique insights into how the value of that subset changes with technology and penetration level. Specifically, in this case study implementation of the model, the marginal economic value of all three solar options is found to exceed the value of a flat-block of power (as well as wind energy) by \$20--30/MWh at low penetration levels, largely due to the high capacity value of solar at low penetration. Because the value of CSP per unit of energy is found to be high with or without thermal energy storage at low penetration, we find little apparent incremental value to thermal storage at low solar penetration in the present case study analysis. The marginal economic value of PV and CSP without thermal storage is found to drop considerably (by more than \$70/MWh) as the penetration of solar increases toward 30\percent on an energy basis. This is due primarily to a steep drop in capacity value followed by a decrease in energy value. In contrast, the value of CSP with thermal storage drops much less dramatically as penetration increases. As a result, at solar penetration levels above 10\percent, CSP with thermal storage is found to be considerably more valuable relative to PV and CSP without thermal storage. The marginal economic value of wind is found to be largely driven by energy value, and is lower than solar at low penetration. The marginal economic value of wind drops at a relatively slower rate with penetration, however. As a result, at high penetration, the value of wind can exceed the value of PV and CSP without thermal storage. Though some of these findings may be somewhat unique to the specific case study presented here, the results: (1) highlight the importance of an analysis framework that addresses long-term investment decisions as well as short-term dispatch and operational constraints, (2) can help inform long-term decisions about renewable energy procurement and supporting infrastructure, and (3) point to areas where further research is warranted.

14 SOLAR ENERGY↗

Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer

Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm{sup 2}) and one higher b value (aHBV at 2000 s/mm{sup 2}). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm{sup 2}) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm{sup 2}) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. Results: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm{sup 2} sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). Conclusion: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

RANGE AND DISTRIBUTION OF TECHNETIUM KD VALUES IN THE SRS SUBSURFACE ENVIRONMENT

Performance assessments (PAs) are risk calculations used to estimate the amount of low-level radioactive waste that can be disposed at DOE sites. Distribution coefficients (K{sub d} values) are input parameters used in PA calculations to provide a measure of radionuclide sorption to sediment; the greater the K{sub d} value, the greater the sorption and the slower the estimated movement of the radionuclide through sediment. Understanding and quantifying K{sub d} value variability is important for estimating the uncertainty of PA calculations. Without this information, it is necessary to make overly conservative estimates about the possible limits of K{sub d} values, which in turn may increase disposal costs. Finally, technetium is commonly found to be amongst the radionuclides posing potential risk at waste disposal locations because it is believed to be highly mobile in its anionic form (pertechnetate, TcO{sub 4}{sup -}), it exists in relatively high concentrations in SRS waste, and it has a long half-life (213,000 years). The objectives of this laboratory study were to determine under SRS environmental conditions: (1) whether and to what extent TcO{sub 4}{sup -} sorbs to sediments, (2) the range of Tc K{sub d} values, (3) the distribution (normal or log-normal) of Tc K{sub d} values, and (4) how strongly Tc sorbs to SRS sediments through desorption experiments. Objective 3, to identify the Tc K{sub d} distribution is important because it provides a statistical description that influences stochastic modeling of estimated risk. The approach taken was to collect 26 sediments from a non-radioactive containing sediment core collected from E-Area, measure Tc K{sub d} values and then perform statistical analysis to describe the measured Tc K{sub d} values. The mean K{sub d} value was 3.4 {+-} 0.5 mL/g and ranged from -2.9 to 11.2 mL/g. The data did not have a Normal distribution (as defined by the Shapiro-Wilk's Statistic) and had a 95-percentile range of 2.4 to 4.4 mL/g. The E-Area subsurface is subdivided into three hydrostratigraphic layers: Upper Vadose Zone (11 to 30 ft depth), Lower Vadose Zone (30 to 51 ft depth), and aquifer (51 to 95 ft depth). The Upper Vadose Zone generally contains more clay than the Lower Vadose Zone, and the Aquifer tends to be made up of mostly sand layers with clay strata. The mean K{sub d} values of each of these zones did not differ significantly and the K{sub d} values from each zone were not from the Normal distribution. The ranges of values were greatest in the Upper Vadose Zone and least in the Lower Vadose Zone. Previous Best Estimate Tc K{sub d} values for Sandy Sediment and Clayey Sediment were 0.1 and 0.2 mL/g, respectively (Kaplan 2007a). A more thorough review indicates that the Best Estimates for Sandy Sediment is 0.1 mL/g and for Clayey Sediment is 0.8 mL/g (Kaplan 2007b). This current dataset greatly increases the number of Tc K{sub d} values measured with SRS sediments, but perhaps more importantly, provides a better estimate for E-Area sediments, and provides a measure of Tc K{sub d} distributions. Based on this dataset, the best overall Tc K{sub d} value for E-Area is the mean, 3.4 mL/g, with a log-normal distribution between the 95 percentile values of 2.4 to 4.4 mL/g. This document version differs from the earlier version, SRNS-STI-2008-00286, in that it includes some editorial corrections. This version does not contain any technical changes or changes to the conclusions presented in the earlier version.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Grid Service Values of Generic Marginal Building Flexibility in Modeled 2030 U.S. Power Systems

The datasets include the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of generic, daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. The results should be interpreted along with the caveats listed in "Valuation of Building Flexibility: Grid Service Value for Initial Market Entrants in Projected 2030 United States Power Systems", which also documents the methods used for the study. The factors examined in the study include: grid scenario, region, original usage hour in the day (local time), and building flexibility parameters - efficiency, dissipation, and shifting window include max pre-shift and max post-shift. Filenames in the datasets: The filenames contain information on the grid scenario, and the building flexibility efficiency and dissipation. For example: MidCase_2030_efficiency1.25_dissipation0.05_value.csv contains all results under Mid RE 2020, efficiency = 1.25, and dissipation = 0.05. * MidCase = Mid RE Each .csv file contains: region: The location of the building flexibility, aligned with U.S. Energy Information Administration (EIA) National Energy Modeling System (NEMS) Electricity Market Module regions. max_pre_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift earlier. max_post_shift: Part of building flexibility shifting window parameter, indicates the max number of hours the building flexibility can shift later. local_datetime: Original datetime of 1kWh of building energy consumption. local_orig_h: Original usage hour (1-24) of building energy consumption, ignores daylight saving. local_shift_to: The datetime to when building energy consumption shifts, if shifting happens. If no shifting occurs, this cell is left blank. energy: Net energy value of energy shifting. capacity: Net capacity value of energy shifting. shifting_value: Net energy plus capacity value of energy shifting. spin: Spin reserve value at the original datetime of consumption. flex: Flexible reserve value at the original datetime of consumption. reg: Regulation reserve value at the original datetime of consumption. total_profit: Assuming the building flexibility is capable of providing energy, capacity, and ancillary services, total profit is the maximum value of energy shifting value, spin reserve value, flexible reserve value, and regulation reserve value - one of the four choices at any given hour - because we do not allow its value to be double-counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-F-BRA-10: Fricke Dosimetry: Determination of the G-Value for Ir-192 Energy Based On the NRC Methodology

Purpose: Use the methodology developed by the National Research Council Canada (NRC), for Fricke Dosimetry, to determine the G-value used at Ir-192 energies. Methods: In this study the Radiology Science Laboratory of Rio de Janeiro State University (LCR),based the G-value determination on the NRC method, using polyethylene bags. Briefly, this method consists of interpolating the G-values calculated for Co-60 and 250 kV x-rays for the average energy of Ir-192 (380 keV). As the Co-60 G-value is well described at literature, and associated with low uncertainties, it wasn’t measured in this present study. The G-values for 150 kV (Effective energy of 68 keV), 250 kV (Effective energy of 132 keV)and 300 kV(Effective energy of 159 keV)were calculated using the air kerma given by a calibrated ion chamber, and making it equivalent to the absorbed to the Fricke solution, using a Monte Carlo calculated factor for this conversion. Instead of interpolations, as described by the NRC, we displayed the G-values points in a graph, and used the line equation to determine the G- value for Ir-192 (380 keV). Results: The measured G-values were 1.436 ± 0.002 µmol/J for 150 kV, 1.472 ± 0.002 µmol/J for 250 kV, 1.497 ± 0.003 µmol/J for 300 kV. The used G-value for Co-60 (1.25 MeV) was 1,613 µmol/J. The R-square of the fitted regression line among those G-value points was 0.991. Using the line equation, the calculate G-value for 380 KeV was 1.542 µmol/J. Conclusion: The Result found for Ir-192 G-value is 3,1% different (lower) from the NRC value. But it agrees with previous literature results, using different methodologies to calculate this parameter. We will continue this experiment measuring the G-value for Co-60 in order to compare with the NRC method and better understand the reasons for the found differences.

07 ISOTOPE AND RADIATION SOURCES↗

Quantifying the Value of Hydropower in the Electric Grid: Final Report

The report summarizes research to Quantify the Value of Hydropower in the Electric Grid. This 3-year DOE study focused on defining value of hydropower assets in a changing electric grid. Methods are described for valuation and planning of pumped storage and conventional hydropower. The project team conducted plant case studies, electric system modeling, market analysis, cost data gathering, and evaluations of operating strategies and constraints. Five other reports detailing these research results are available a project website, www.epri.com/hydrogrid. With increasing deployment of wind and solar renewable generation, many owners, operators, and developers of hydropower have recognized the opportunity to provide more flexibility and ancillary services to the electric grid. To quantify value of services, this study focused on the Western Electric Coordinating Council region. A security-constrained, unit commitment and economic dispatch model was used to quantify the role of hydropower for several future energy scenarios up to 2020. This hourly production simulation considered transmission requirements to deliver energy, including future expansion plans. Both energy and ancillary service values were considered. Addressing specifically the quantification of pumped storage value, no single value stream dominated predicted plant contributions in various energy futures. Modeling confirmed that service value depends greatly on location and on competition with other available grid support resources. In this summary, ten different value streams related to hydropower are described. These fell into three categories; operational improvements, new technologies, and electricity market opportunities. Of these ten, the study was able to quantify a monetary value in six by applying both present day and future scenarios for operating the electric grid. This study confirmed that hydropower resources across the United States contribute significantly to operation of the grid in terms of energy, capacity, and ancillary services. Many potential improvements to existing hydropower plants were found to be cost-effective. Pumped storage is the most likely form of large new hydro asset expansions in the U.S. however, justifying investments in new pumped storage plants remains very challenging with current electricity market economics. Even over a wide range of possible energy futures, up to 2020, no energy future was found to bring quantifiable revenues sufficient to cover estimated costs of plant construction. Value streams not quantified in this study may provide a different cost-benefit balance and an economic tipping point for hydro. Future studies are essential in the quest to quantify the full potential value. Additional research should consider the value of services provided by advanced storage hydropower and pumped storage at smaller time steps for integration of variable renewable resources, and should include all possible value streams such as capacity value and portfolio benefits i.e.; reducing cycling on traditional generation.

13 HYDRO ENERGY↗

Hydropower Value Drivers

Conventional hydro resources generate the majority of their value by providing energy under most conditions, but the relative fraction of value generated by providing ancillary services and capacity increases with increasing penetration of resources with zero fuel costs. Pumped storage hydropower resources generate the majority of their value by providing capacity under most conditions, but the relative fraction of value generated by providing energy increases with increasing penetration of resources with zero fuel costs. The total value of conventional hydropower generally decreases in systems with increasing penetration of resources with zero fuel costs; this is largely due to the associated decrease in average energy prices. The total value of pumped storage generally increases in systems with increasing penetration of resources with zero fuel costs, largely due to opportunities to operate in pumping mode when energy prices are low or even negative. Energy storage representation must be enhanced to ensure that models accurately capture system value streams for these resources. Current power system models have a limited ability to capture the price dynamics of ancillary services, and it is still challenging to assess the role and magnitude of ancillary service value streams in future systems. Power systems are currently in a state of rapid and dramatic evolution due to a number of different factors, including the increasing penetration of variable renewable energy (VRE) sources, such as wind and solar, and battery energy storage systems (BESS). This evolution will change the way power systems are fundamentally planned and operated. Some of these changes may be incremental, while others may be more significant, but the result will likely be parallel evolution in the definition and requirement of different grid services and therefore a subsequent shift in their relative values. This report presents a framework developed to identify such system value drivers and quantify their relative impact on several different value streams, with a specific focus on implications for conventional hydropower and pumped storage hydropower (PSH) resources. This value drivers framework (VDF) encompasses five core analytical steps: 1. Identify potential drivers and develop scenarios, 2. Execute production cost models, 3. Calibrate prices, 4. Optimize hydropower operations, and 5. Quantify value drivers.

13 HYDRO ENERGY↗

Stable carbon isotope values of syndepositional carbonate spherules and micrite record spatial and temporal changes in photosynthesis intensity

Marine and lacustrine carbonate minerals preserve carbon cycle information, and their stable carbon isotope values (δ 13 C) are frequently used to infer and reconstruct paleoenvironmental changes. However, multiple processes can influence the δ 13 C values of bulk carbonates, confounding the interpretation of these values in terms of conditions at the time of mineral precipitation. Co-existing carbonate forms may represent different environmental conditions, yet few studies have analyzed δ 13 C values of syndepositional carbonate grains of varying morphologies to investigate their origins. Here, we combine stable isotope analyses, metagenomics, and geochemical modeling to interpret δ 13 C values of syndepositional carbonate spherules (>500 μm) and fine-grained micrite (<63 μm) from a ~1600-year-long sediment record of a hypersaline lake located on the coral atoll of Kiritimati, Republic of Kiribati (1.9°N, 157.4°W). Petrographic, mineralogic, and stable isotope results suggest that both carbonate fractions precipitate in situ with minor diagenetic alterations. The δ 13 C values of spherules are high compared to the syndepositional micrite and cannot be explained by mineral differences or external perturbations, suggesting a role for local biological processes. We use geochemical modeling to test the hypothesis that the spherules form in the surface microbial mat during peak diurnal photosynthesis when the δ 13 C value of dissolved inorganic carbon is elevated. In contrast, we hypothesize that the micrite may precipitate more continuously in the water as well as in sub-surface, heterotrophic layers of the microbial mat. Both metagenome and geochemical model results support a critical role for photosynthesis in influencing carbonate δ 13 C values. The down-core spherule–micrite offset in δ 13 C values also aligns with total organic carbon values, suggesting that the difference in the δ13C values of spherules and micrite may be a more robust, inorganic indicator of variability in productivity and local biological processes through time than the δ 13 C values of individual carbonate forms.

59 BASIC BIOLOGICAL SCIENCES↗

WE-G-18C-02: Estimation of Optimal B-Value Set for Obtaining Apparent Diffusion Coefficient Free From Perfusion in Non-Small Cell Lung Cancer

Purpose: Diffusion-weighted MRI (DW-MRI) is increasingly being investigated for radiotherapy planning and response assessment. Selection of a limited number of b-values in DW-MRI is important to keep geometrical variations low and imaging time short. We investigated various b-value sets to determine an optimal set for obtaining monoexponential apparent diffusion coefficient (ADC) close to perfusion-insensitive intravoxel incoherent motion (IVIM) model ADC (ADC IVIM ) in nonsmall cell lung cancer. Methods: Seven patients had 27 DW-MRI scans before and during radiotherapy in a 1.5T scanner. Respiratory triggering was applied to the echo-planar DW-MRI with TR=4500ms approximately, TE=74ms, pixel size=1.98X1.98mm{sub 2}, slice thickness=4–6mm and 7 axial slices. Diffusion gradients were applied to all three axes producing traceweighted images with eight b-values of 0–1000μs/μm{sup 2}. Monoexponential model ADC values using various b-value sets were compared to ADC IVIM using all b-values. To compare the relative noise in ADC maps, intra-scan coefficient of variation (CV) of active tumor volumes was computed. Results: ADC IVIM , perfusion coefficient and perfusion fraction for tumor volumes were in the range of 880-1622 μm{sup 2}/s, 8119-33834 μm{sup 2}/s and 0.104–0.349, respectively. ADC values using sets of 250, 800 and 1000; 250, 650 and 1000; and 250–1000μs/μm{sup 2} only were not significantly different from ADC IVIM (p>0.05, paired t-test). Error in ADC values for 0–1000, 50–1000, 100–1000, 250–1000, 500–1000, and three b-value sets- 250, 500 and 1000; 250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2} were 15.0, 9.4, 5.6, 1.4, 11.7, 3.7, 2.0 and 0.2% relative to the reference-standard ADC IVIM , respectively. Mean intrascan CV was 20.2, 20.9, 21.9, 24.9, 32.6, 25.8, 25.4 and 24.8%, respectively, whereas that for ADC IVIM was 23.3%. Conclusion: ADC values of two 3 b-value sets (250, 650 and 1000; and 250, 800 and 1000μs/μm{sup 2}) approached ADC IVIM , with relative noise comparable to that of ADC IVIM . These sets may be used to obtain perfusion-insensitive ADC values in lung tumors. E. Weiss: Funding through Varian Medical Systems and Philips Oncology Systems, UpToDate royalties. G. Hugo: NIH R01CA166119, P01 CA116602, NHMRC Project Grant.

60 APPLIED LIFE SCIENCES↗

GPS FOM Chimney Analysis using Generalized Extreme Value Distribution

Many a time an objective of a statistical analysis is to estimate a limit value like 3-sigma 95% confidence upper limit from a data sample. The generalized Extreme Value Distribution method can be profitably employed in many situations for such an estimate. . .. It is well known that according to the Central Limit theorem the mean value of a large data set is normally distributed irrespective of the distribution of the data from which the mean value is derived. In a somewhat similar fashion it is observed that many times the extreme value of a data set has a distribution that can be formulated with a Generalized Distribution. In space shuttle entry with 3-string GPS navigation the Figure Of Merit (FOM) value gives a measure of GPS navigated state accuracy. A GPS navigated state with FOM of 6 or higher is deemed unacceptable and is said to form a FOM 6 or higher chimney. A FOM chimney is a period of time during which the FOM value stays higher than 5. A longer period of FOM of value 6 or higher causes navigated state to accumulate more error for a lack of state update. For an acceptable landing it is imperative that the state error remains low and hence at low altitude during entry GPS data of FOM greater than 5 must not last more than 138 seconds. I To test the GPS performAnce many entry test cases were simulated at the Avionics Development Laboratory. Only high value FoM chimneys are consequential. The extreme value statistical technique is applied to analyze high value FOM chimneys. The Maximum likelihood method is used to determine parameters that characterize the GEV distribution, and then the limit value statistics are estimated.

Ott, Rick↗

Redefining fuel heating value for engines: Accounting for heat of vaporization

Defining a fuel's heating value (i.e., energy content) is fundamental for calculating engine efficiency and for life cycle analysis comparisons between different fuels. Traditional definitions of lower heating value and higher heating value account for the effect of water vapor versus liquid water in the exhaust, which is important when the fuel is used in a furnace or boiler. In an engine, it is equally important to properly account for the energy required to vaporize liquid fuel. Heat of vaporization has a small effect for common hydrocarbon fuels, typically less than 1% of lower heating value, but the effect is much larger for other important fuels such as ethanol (3.4% of lower heating value) and methanol (5.9% of lower heating value). This paper defines a new type of fuel heating value that more accurately reflects the useful fuel energy content for engines. Vaporized heating value is defined as the heating value when starting with a vaporized fuel instead of a liquid fuel. It can be calculated by adding the fuel's heat of vaporization to the traditional lower heating value. This paper illustrates the rationale and benefits of using vaporized heating value using data from the literature.

09 BIOMASS FUELS↗

Applying the Transactive Systems Business Value Model to IRP

As part of the Transactive Systems Program at Pacific Northwest National Laboratory, a value modeling system was developed to support the evaluation of transactive systems. The technique is general enough to be applied outside transactive systems and to demonstrate this capability, a project was undertaken to use this value modeling technique as a means for modeling the valuation process undertaken by vertically integrated utilities when undergoing integrated resource planning (IRP). IRP is the process by which vertically integrated utilities (those that both serve customers directly as well as manage and run generation assets to do so) regularly go through to demonstrate to their regulators that they have a plan to meet the expected future load of their customers in a least cost and compliant manner. Traditionally this has been primarily an issue of how many and of which types of power plants to build but increasingly has included alternative measures such as demand response programs. Increasingly, environmental regulations play a significant role in both determine what types of power plants can be built under current regulations as well as what retrofits or upgrades need to be made to existing plants to allow them to continue to operate. Two use-case diagrams were constructed, one showing the showing the process by which IRP is carried out and another showing how a vertically integrated utility procures the resources it requires to meet load now and in the future. These diagrams help clarify the difference and provide a high-level outline of the two processes. A class diagram was constructed to clearly define the types of actors that would be considered in this model and the relationships between them. This diagram tacitly indicates which types of actors are and are not included in the model which provides significant guidance in defining the scope of the model. The relationship between the classes/actors provides further indication of what areas of the model have higher levels of detail and by implication bear more significance in modeling the system. Using the classes/actors defined in the class diagram, a business value diagram was constructed that defines the key value streams exchanged between the actors. This diagram provides a clear expression of the business case of the vertically integrated utility and who its counterparties are during the process of meeting load. These value streams have not only to do with meeting the load but doing so in a manner that meets environmental regulations. Increasingly, IRPs have three key metrics to evaluate a given plant to meet load: net present value of revenue required, emissions, and renewable energy credits. From this business value diagram, more detailed activity diagrams were formed that focus on a few of the key value stream exchanges, showing the process by which each party accrues value. These diagrams provide insight into the timing and sequence of the interactions in a way that the business value diagrams did not. The transactive value model was found to be highly compatible with IRP and provided a clear, simple model of the analysis done during IRP and key metrics driving IRP decisions. In particular it highlighted a few key items that may or may not have been as clear prior to the development of the model. Specifically, the role of the environmental regulations has become increasingly important and two of the three key metrics by which IRPs are typically evaluated are environmentally focused. Additionally, though generally not acknowledged, the role of the investor was included in this model as they are an essential source of capital in building new power plants and cannot be ignored when defining the business case of the vertically integrated utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗