Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPOR, WATER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of wood fiber insulation for the development of wood fiber-insulated panels (WIPs) for use in building envelope

Wood fiber insulation (WFI) was studied as an eco-friendly alternative for fossil-based building insulation, focusing on its use in new wood fiber-insulated panels (WIPs). Rigid WFI boards with densities of 110, 140, and 180 kg/m³, including a 140 kg/m³ variant without paraffin wax, were evaluated. Key properties investigated included porosity, water vapor transmission, liquid water adsorption, and thermal conductivity. The porosity ranged between 85 and 92%, primarily influenced by density. Water vapor permeability ranged from 65 to 90 ng·s-1m-1Pa-1, while liquid water absorption was between 2.5 and 20% by volume, influenced by both wax and density. The thermal conductivity coefficient ranged from 0.038 to 0.055 W/(m·K). Bond strength tests with WFI (140 kg/m³ with wax) laminated to various materials using structural adhesives showed tensile perpendicular-to-grain strengths of 10 to 16 kPa and shear strengths of 60 to 90 kPa, with failure only occurring within the WFI. It was concluded that WFI is a promising material for novel WIPs, offering competitive hygrothermal properties and compatibility with structural adhesives. However, its bio-based nature suggests variability and complexity, necessitating further rigorous testing in various climates and in more complex assemblies.

Materials Science↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water sources and land capacitor effects stimulate observed summer Arctic moistening and warming

The primary sources of recent summer Arctic moistening trends in reanalysis are uncertain, hindering attribution of observed Arctic warming due to radiative effects from water vapor changes. Here, we use a combined online numerical water tracer and circulation nudging approach in the Community Earth System Model to track the sources of water vapor beyond its initial sources. Trends in boreal summer large-scale circulation have driven moistening of the Arctic over recent decades, having a large impact on the Arctic radiative budget, accounting for 94% of the strengthening water vapor radiative feedback. We identify two key regions supplying the Arctic water vapor feedback: Northeast North America and western/central Eurasia. In both regions, anticyclonic circulations over the southwest Atlantic and eastern Europe move moisture from the tropical oceans poleward to high latitude land through precipitation in winter and spring. During summer, evapotranspiration over land releases this water vapor, and it is transported by winds into the Arctic. We refer to this sequence of terrestrial moisture storage and release as the land capacitor effect. Thus, the impacts of circulation changes on poleward moisture transport and land-atmosphere interactions over high latitudes represent the underlying mechanisms of the recent moistening and warming in the Arctic.

Arctic amplification↗

Hydroxylation and Cation Segregation in (La 0.5 Sr 0.5 )FeO 3-$δ$ Electrodes

Simultaneously achieving high activity and stability is the primary challenge when engineering (electro)catalysts. Transition metal perovskite oxides are employed as air electrodes for solid-oxide fuel cells and electrolyzers. However, degradation of oxygen exchange kinetics at the solid–gas interface, often linked to alkaline-earth cation segregation and precipitation, limits widespread commercialization. Here, we systematically investigated the surface degradation mechanism induced by gas-phase impurities in La 0.5 Sr 0.5 )FeO 3-$δ$ (LSF55) thin-film electrodes by varying the concentration of H 2 O, SO 2 , and CO 2 . Degradation of the area-specific resistance in ambient and humidified synthetic air is significantly greater than in dry ambient and dry synthetic air, pointing to the importance of water vapor. Time-resolved, in situ ambient pressure X-ray photoelectron spectroscopy performed in O 2 showed that nonbulk Sr is present on the surface before the exposure to water vapor. Upon introduction of water vapor, neither additional Sr segregation nor precipitation driven by water vapor is a necessary condition for degradation. Rather, hydroxylation of the surface induces irreversible and significant degradation. At the same time, we show that Sr migration driven by water vapor is partially reversible. These fundamental insights can be used for the rational design of electrodes with improved catalytic stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wet to Dry Controls Lanthanide Scandate Synthesis

The choice of temperature and gas conditions used in a water pressure-controlled reactor is guided by density functional theory (DFT) to synthesize nearly phase pure lanthanide scandate nanoparticles (LnScO 3 , Ln = La, Nd, Sm, Gd). In this synthetic method, low water vapor partial pressures, well below water’s gas liquidus, inhibit particle growth, while an excess of water vapor results in undesired rare earth hydroxide and oxyhydroxide secondary phases. The optimal humidity for high-purity LnScO 3 particle synthesis is shown to vary with the lanthanide; DFT is used to calculate the thermodynamics of secondary phase formation for each lanthanide tested, such that the role of water vapor may be quantified and used to maintain phase purity (greater than 96 mol%) across the series. Furthermore, the combination of thermodynamic calculation and experimental confirmation with this pressure-controlled reactor provides an opportunity to explore analogous syntheses of other inorganic perovskite nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Climate-Relevant Gas Absorption Properties from AWARE and Other ARM Spectral Measurements (Final Report)

The objective of this project has been to use measurements from the Atmospheric Emitted Radiance Interferometer (AERI) deployed at ARM sites to improve our knowledge of uncertain infrared spectroscopic parameters of importance to climate, remote sensing, and data assimilation. A primary focus has been the water vapor continuum in the infrared atmospheric window. Radiation codes used to predict climate and weather base their representation of the water vapor continuum in this window on the MT_CKD model, but in this spectral region the MT_CKD water vapor continuum absorption coefficients were derived almost two decades ago by an analysis of AERI measurements for conditions with a limited range of precipitable water vapor (PWV) and temperature values, leading to uncertainty in the derived coefficients. This project has included a new, comprehensive analysis of all aspects of the water vapor continuum in the atmospheric window -- the self continuum, the foreign continuum, and the self continuum temperature dependence, all resolved spectrally. Having a wide range of PWV amounts and temperatures from deployments of the ARM Mobile Facility for GoAmazon as well as the more than a decade of AERI measurements at SGP has provided an appropriate foundation for such a comprehensive analysis.

54 ENVIRONMENTAL SCIENCES↗

Lagrangian and Eulerian Supersaturation Statistics in Turbulent Cloudy Rayleigh–Bénard Convection: Applications for LES Subgrid Modeling

Abstract Turbulent fluctuations of scalar and velocity fields are critical for cloud microphysical processes, e.g., droplet activation and size distribution evolution, and can therefore influence cloud radiative forcing and precipitation formation. Lagrangian and Eulerian water vapor, temperature, and supersaturation statistics are investigated in direct numerical simulations (DNS) of turbulent Rayleigh–Bénard convection in the Pi Convection Cloud Chamber to provide a foundation for parameterizing subgrid-scale fluctuations in atmospheric models. A subgrid model for water vapor and temperature variances and covariance and supersaturation variance is proposed, valid for both clear and cloudy conditions. Evaluation of phase change contributions through an a priori test using DNS data shows good performance of the model. Supersaturation is a nonlinear function of temperature and water vapor, and relative external fluxes of water vapor and heat (e.g., during entrainment-mixing and phase change) influence turbulent supersaturation fluctuations. Although supersaturation has autocorrelation and structure functions similar to the independent scalars (temperature and water vapor), the autocorrelation time scale of supersaturation differs. Relative scalar fluxes in DNS without cloud make supersaturation PDFs less skewed than the adiabatic case, where they are highly negatively skewed. However, droplet condensation changes the PDF shape response: it becomes positively skewed for the adiabatic case and negatively skewed when the sidewall relative fluxes are large. Condensation also increases correlations between water vapor and temperature in the presence of relative scalar fluxes but decreases correlations for the adiabatic case. These changes in correlation suppress supersaturation variability for the nonadiabatic cases and increase it for the adiabatic case. Implications of this work for subgrid microphysics modeling using a Lagrangian stochastic scheme are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Comparing multi-model ensemble simulations with observations and decadal projections of upper atmospheric variations following the Hunga eruption

The Hunga Tonga–Hunga Ha'apai Model–Observation Comparison (HTHH–MOC) project aims to comprehensively investigate the evolution of volcanic water vapor and sulfur emissions and their subsequent atmospheric impacts and underlying response mechanisms using state-of-the-art global climate models. This study evaluates multi-model ensemble simulations participating in the HTHH–MOC free-run experiment with climate projections for 10 years (2022–2032). Model results are evaluated against satellite observations to assess their ability to reproduce the observed evolution of stratospheric water vapor, aerosols, temperature, and ozone from 2022 to 2024. The participating models accurately capture the observed distribution patterns and associated upper atmospheric responses, providing confidence for their future projections. Model simulations suggest that the Hunga eruption-induced stratospheric water vapor anomaly lasts 4–7 years, with a water vapor e-folding time of 31–43 months. This prolonged water vapor perturbation leads to significant stratospheric and mesospheric cooling, resulting in significant ozone loss in the upper stratosphere and lower mesosphere for 7–10 years. Comparisons between simulations with both SO 2 and H 2 O emissions and those with H 2 O-only emissions indicate that the pronounced dipole response with upper-stratospheric cooling and lower-stratospheric warming is driven by the combined effects of SO 2 and H 2 O injections. These results highlight the prolonged atmospheric impacts of the Hunga eruption and the potential critical role of stratospheric water vapor in modulating long-term atmospheric chemistry and dynamics.

Zhuo, Zhihong [Univ. of Quebec, Montreal, QC (Cana↗

Effect of Evaporation on Vapor Space Flammability in DWPF Process Vessels - 20278

The Savannah River Site (SRS) Defense Waste Processing Facility (DWPF) processes liquid high-level waste (HLW) and encapsulates it in glass within stainless-steel containers suitable for safe, long-term storage and disposal. Radiolytic and chemical decomposition of the liquid waste generates hydrogen and other flammable gases creating a hazard. The rate of flammable gas generation increases by an order of magnitude as temperature increases from sub-boiling to boiling. DWPF controls this hazard in process tanks by ensuring a minimum purge flow through each tank's head space. The minimum purge flow rate is established assuming dry air and neglecting evaporation. However, this study determined that steam from boiling in a representative process tank is sufficient to dilute flammable gases and, thereby, preclude flammability. For sub-boiling, water vapor is an insufficient diluent considering hydrogen's lower flammable limit (LFL) in air. However, the upper and lower flammable limits approach each other in a hydrogen-air-water-vapor environment as the water vapor concentration increases. This effect may preclude flammable conditions if water vapor concentration is about 60 volume percent or higher. A saturated, constant-pressure air-water system would achieve 60 volume percent water vapor at 86 deg. C. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Supersaturation Variability from Scalar Mixing: Evaluation of a New Subgrid-Scale Model Using Direct Numerical Simulations of Turbulent Rayleigh–Bénard Convection

We report that supersaturation fluctuations in the atmosphere are critical for cloud processes. A nonlinear dependence on two scalars - water vapor and temperature - leads to different behavior than single scalars in turbulent convection. For modeling such multiscalar processes at subgrid scales (SGS) in large-eddy simulations (LES) or convection-permitting models, a new SGS scheme is implemented in CM1 that solves equations for SGS water vapor and temperature fluctuations and their covariance. The SGS model is evaluated using benchmark direct-numerical simulations (DNS) of turbulent Rayleigh–Bénard convection with water vapor as in the Michigan Tech Pi Cloud Chamber. This idealized setup allows thorough evaluation of the SGS model without complications from other atmospheric processes. DNS results compare favorably with measurements from the chamber. Results from LES using the new SGS model compare well with DNS, including profiles of water vapor and temperature variances, their covariance, and supersaturation variance. SGS supersaturation fluctuations scale appropriately with changes to the LES grid spacing, with the magnitude of SGS fluctuations decreasing relative to those at the resolved scale as the grid spacing is decreased. Sensitivities of covariance and supersaturation statistics to changes in water vapor flux relative to thermal flux are also investigated by modifying the sidewall conditions. Relative changes in water vapor flux substantially decrease the covariance and increase supersaturation fluctuations even away from boundaries.

54 ENVIRONMENTAL SCIENCES↗

WACCM6 Projections of Polar Mesospheric Cloud Abundance Over the 21st Century

Polar mesospheric clouds (PMC), or noctilucent clouds, can be observed over high latitudes with the naked eye from the ground or from space near the summer solstice. PMC are considered a direct and sensitive indicator of climate change and have been reported to appear more frequently in recent decades. How PMC will change in the future under the influence of natural variability and anthropogenic forcing is uncertain. In this study, we utilize model output from the Whole Atmosphere Community Climate Model under several shared socioeconomic pathway (SSP) scenarios and input the water vapor, temperature, and pressure information into a 0-d PMC model to project the trend and variation of PMC over the 21st century, and their relationship to future changes of temperature, water vapor, and the solar cycle. The 0-d model calculations indicate that PMC ice water content (IWC) will increase and PMC will extend to lower latitudes under high SSP scenarios. Under these scenarios, more mesospheric water vapor leads to an increased IWC of PMC over the polar region, and colder mesopause temperature leads to more PMC over the mid-latitudes. There is a significant anti-correlation between the solar cycle and PMC IWC over the 21st century, but the anti-correlation is not always significant on the decadal scale. Finally, methane oxidation in the stratosphere and water vapor entering from the troposphere are both responsible for future changes in mesospheric water vapor and thus PMC.

54 ENVIRONMENTAL SCIENCES↗

Vapor kinetic energy for the detection and understanding of atmospheric rivers

Poleward water vapor transport in the midlatitudes mainly occurs in meandering filaments of intense water vapor transport, spanning thousands of kilometers long and hundreds of kilometers wide and moving eastward. The water vapor filaments are known as atmospheric rivers (ARs). They can cause extreme wind gusts, intense precipitation, and flooding along densely populated coastal regions. Many recent studies about ARs focused on the statistical analyses of ARs, but a process-level understanding of ARs remains elusive. Here we show that ARs are streams of air with enhanced vapor kinetic energy (VKE) and derive a governing equation for Integrated VKE to understand what contributes to the evolution of ARs. We find that ARs grow mainly because of potential energy conversion to kinetic energy, decay largely owing to condensation and turbulence, and the eastward movement is primarily due to horizontal advection of VKE. Our VKE framework complements the integrated vapor transport framework, which is popular for identifying ARs but lacks a prognostic equation for understanding the physical processes.

54 ENVIRONMENTAL SCIENCES↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Water effects on NH 3 -SCR over Cu-based small-pore zeolite catalysts: A review

The selective catalytic reduction (SCR) of NO x with NH 3 as the reductant over small-pore Cu-zeolite catalysts is a leading strategy for controlling emissions from diesel engines and mobile sources. While the hydrothermal stability of Cu-zeolites such as Cu-SSZ-13, Cu-SAPO-34, and Cu-SSZ-39 has been extensively studied, the multifaceted role of water vapor under operating conditions has only recently received systematic attention. Water impacts multiple aspects of SCR catalysis, including NO x conversion, N 2 O formation, Cu ion speciation, redox kinetics, and surface reactions. This review comprehensively summarizes recent advances in understanding the effect of water on NH 3 -SCR over Cu-based catalysts. For Cu-SSZ-13, water vapor induces both inhibitory and promotive effects depending on temperature, Cu loading, and Si/Al ratio by altering NH 3 adsorption, Cu mobility, and redox half-cycle kinetics. Studies have revealed that water can suppress ammonium nitrate formation at low temperatures and enhance nitrate pathways at higher temperatures. Over Cu-SAPO-34, water promotes NO conversion by improving Cu(II) reducibility and strengthening Brønsted acidity. First-principles calculations confirm that water-coordinated Cu species lower O 2 activation barriers. In Cu-SSZ-39, water was found to facilitate Cu reduction, migration, and O 2 activation, resulting in superior water tolerance and unexpected catalytic promotion. Both experimental and computational studies highlight that water vapor exerts complex, catalyst-dependent effects on NH 3 -SCR performance, underscoring the need for tailored catalyst designs that leverage beneficial water interactions while minimizing inhibitory impacts.

Ammonia selective catalytic reduction↗

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Sensitivity of the Shallow‐To‐Deep Convective Transition to Moisture and Wind Shear in the Amazon

Deep convection is the primary influence on weather and climate in tropical regions. However, understanding and simulating the shallow‐to‐deep (STD) convective transition has long been challenging. Here, we conduct high‐resolution numerical simulations to assess the environmental controls on the evolution of isolated convection in the Amazon during the wet season. The large‐scale forcing derived through a constrained variational analysis approach for the GoAmazon2014/5 Experiment is used in the simulations. Through sensitivity experiments, we examine the relative importance of moisture and wind shear in controlling the shallow‐to‐deep convective transition for isolated convective events. Convection exhibits the greatest sensitivity to humidity within the lowest 1.5 km, where a 4 mm reduction in column water vapor nearly suppresses ice water formation on deep convective days. In contrast, a reduction in column water vapor in the free troposphere by a factor of two or more is necessary to produce a comparable impact on convection. Increasing low‐level wind speed from 6 to 9 m s -1 enhances afternoon deep convection, raising the cloud ice mixing ratio by approximately 25%. Conversely, upper‐level wind shear reveals the weakest correlation with daytime convection in our simulations. Our results help characterize the role of moisture and wind shear on the STD transition and our understanding of the underlying mechanisms.

environmental controls↗

Guiding Principles for Geochemical/Thermodynamic Model Development and Validation in Nuclear Waste Disposal: A Close Examination of Recent Thermodynamic Models for H + —Nd 3+ —NO 3 - (—Oxalate) Systems

Development of a defensible source-term model (STM), usually a thermodynamical model for radionuclide solubility calculations, is critical to a performance assessment (PA) of a geologic repository for nuclear waste disposal. Such a model is generally subjected to rigorous regulatory scrutiny. In this article, we highlight key guiding principles for STM model development and validation in nuclear waste management. We illustrate these principles by closely examining three recently developed thermodynamic models with the Pitzer formulism for aqueous H + —Nd 3+ —NO 3 - (—oxalate) systems in a reverse alphabetical order of the authors: the XW model developed by Xiong and Wang, the OWC model developed by Oakes et al., and the GLC model developed by Guignot et al., among which the XW model deals with trace activity coefficients for Nd(III), while the OWC and GLC models are for concentrated Nd(NO 3 ) 3 electrolyte solutions. The principles highlighted include the following: (1) Principle 1. Validation against independent experimental data: A model should be validated against experimental data or field observations that have not been used in the original model parameterization. We tested the XW model against multiple independent experimental data sets including electromotive force (EMF), solubility, water vapor, and water activity measurements. The results show that the XW model is accurate and valid for its intended use for predicting trace activity coefficients and therefore Nd solubility in repository environments. (2) Principle 2. Testing for relevant and sensitive variables: Solution pH is such a variable for an STM and easily acquirable. All three models are checked for their ability to predict pH conditions in Nd(NO 3 ) 3 electrolyte solutions. The OWC model fails to provide a reasonable estimate for solution pH conditions, thus casting serious doubt on its validity for a source-term calculation. In contrast, both the XW and GLC models predict close-to-neutral pH values, in agreement with experimental measurements. (3) Principle 3. Honoring physical constraints: Upon close examination, it is found that the Nd(III)-NO 3 association schema in the OWC model suffers from two shortcomings. Firstly, its second stepwise stability constant for Nd(NO 3 ) 2+ (log K 2 ) is much higher than the first stepwise stability constant for NdNO 3 2+ (log K 1 ), thus violating the general rule of (log K 2 –log K 1 ) < 0, or $\frac{K1}{K2}$>1. Secondly, the OWC model predicts abnormally high activity coefficients for Nd(NO 3 ) 2 + (up to ~900) as the concentration increases. (4) Principle 4. Minimizing degrees of freedom for model fitting: The OWC model with nine fitted parameters is compared with the GLC model with five fitted parameters, as both models apply to the concentrated region for Nd(NO 3 ) 3 electrolyte solutions. The latter appears superior to the former because the latter can fit osmotic coefficient data equally well with fewer model parameters. The work presented here thus illustrates the salient points of geochemical model development, selection, and validation in nuclear waste management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ground-based observations of cloud and drizzle liquid water path in stratocumulus clouds

Abstract. The partition of cloud and drizzle water path in precipitating clouds plays a key role in determining the cloud lifetime and its evolution. A technique to quantify cloud and drizzle water path by combining measurements from a three-channel microwave radiometer (23.8, 30, and 90 GHz) with those from a vertically pointing Doppler cloud radar and a ceilometer is presented. The technique is showcased using 1 d of observations to derive precipitable water vapor, liquid water path, cloud water path, drizzle water path below the cloud base, and drizzle water path above the cloud base in precipitating stratocumulus clouds. The resulting cloud and drizzle water path within the cloud are in good qualitative agreement with the information extracted from the radar Doppler spectra. The technique is then applied to 10 d each of precipitating closed and open cellular marine stratocumuli. In the closed-cell systems only ~20 % of the available drizzle in the cloud falls below the cloud base, compared to ~40 % in the open-cell systems. In closed-cell systems precipitation is associated with radiative cooling at the cloud top <-100W m -2 and a liquid water path >200 g m -2 . However, drizzle in the cloud begins to exist at weak radiative cooling and liquid water path >~150 g m-2. Our results collectively demonstrate that neglecting scattering effects for frequencies at and above 90 GHz leads to overestimation of the total liquid water path of about 10 %–15 %, while their inclusion paves the path for retrieving drizzle properties within the cloud.

Cadeddu, Maria P.↗