Atmospheric water vapor measurements - Comparison of microwave radiometry and lidar
The NASA/GSFC Crustal Dynamics Project microwave water vapor radiometer (J03) is evaluated in terms of measurements of the integrated precipitable water vapor content of a particular column of the troposphere. The measurements were taken during the Atmospheric Moisture Intercomparison Study (ATMIS) held at Wallops Island (Virginia) during April 1989. Water vapor sensing instruments used during ATMIS, included radiometers, radiosondes, and the NASA/GSFC Raman lidar. Comparisons between water vapor measurements by the radiometer and the lidar yielded a correlation coefficient of 0.998 and rms differences for three nights of -0.2 +/- 0.2 mm (April 11-12), -0.8 +/- 0.5 mm (April 16-17), and -0.4 +/- 0.3 mm (April 17-18). The integrated precipitable water vapor measurements for these three nights were approximately 5, 10 and 21 mm, respectively. This study shows that the radiometer provides accurate continuous measurements of the water vapor integrated through the depth of the atmosphere.