Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION PROTECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Numerical determination of the transmissibility characteristics of a squeeze film damped forced vibration system

Numerical solutions of the governing equations of motion of a liquid squeeze film damped forced vibration system were carried out to examine the feasibility of using a liquid squeeze film to cushion and protect large structures, such as buildings, located in areas of high seismic activity. The mathematical model used was that for a single degree of freedom squeeze film damped spring mass system. The input disturbance was simulated by curve fitting actual seismic data with an eleventh order Lagranging polynomial technique. Only the normal component of the seismic input was considered. The nonlinear, nonhomogeneous governing differential equation of motion was solved numerically to determine the transmissibility over a wide range of physical parameters using a fourth-order Runge-Kutta technique. It is determined that a liquid squeeze film used as a damping agent in a spring-mass system can significantly reduce the response amplitude for a seismic input disturbance.

Sutton, M. A.↗

An Overview of LO-DuSST (Lunar Occupancy Dust Surface Separation Technologies) Objectives

Of the myriad of issues facing lunar exploration and maintaining an extended lunar presence, lunar dust is possibly the most pervasive. These jagged, chemically reactive, electrostatically charged, sometimes magnetic particles can impact every aspect of a lunar surface mission ranging from abrading extra-vehicular activity (EVA) suits to disrupting lunar vehicle thermal management systems to impeding efficacy of excavation equipment to impacting lunar inhabitant health. NASA’s Lunar Occupancy Dust Surface Separation Technologies (LO-DuSST) task, as a part of the broader Lunar Surface Innovation Initiative (LSII) project, seeks to implement synergistic active and passive lunar dust management and mitigation technologies for an array of applications. One such application is protection of power generation capabilities via solar panel arrays. Plasma dust lofting coupled with a piezoelectric-driven vibration technology will be demonstrated on solar panel surfaces contaminated with lunar dust simulant. Intrinsically low adhesion coatings will be applied to these surfaces to enhance dust removal. Electrostatic repulsion in confined geometries and materials to manage high velocity lunar dust wear will also be investigated. Collectively, these active and passive mitigation technologies will facilitate lunar surface operations including occupancy logistics, landing pad operations, power generation, and transportation. Initial results regarding lunar simulant-contaminated solar panel performance experiments, dust lofting using an electron beam, surface interactions of high velocity lunar dust arising from lunar lander plume-surface interactions, and lunar dust simulant-material interaction experiments will be discussed.

Lunar dust↗

Ergodicity breaking in rapidly rotating C 60 fullerenes

Ergodicity, the central tenet of statistical mechanics, requires an isolated system to explore all available phase space constrained by energy and symmetry. Mechanisms for violating ergodicity are of interest for probing nonequilibrium matter and protecting quantum coherence in complex systems. Polyatomic molecules have long served as a platform for probing ergodicity breaking in vibrational energy transport. Here, we report the observation of rotational ergodicity breaking in an unprecedentedly large molecule, 12 C 60 , determined from its icosahedral rovibrational fine structure. The ergodicity breaking occurs well below the vibrational ergodicity threshold and exhibits multiple transitions between ergodic and nonergodic regimes with increasing angular momentum. These peculiar dynamics result from the molecule’s distinctive combination of symmetry, size, and rigidity, highlighting its relevance to emergent phenomena in mesoscopic quantum systems.

Science & Technology - Other Topics↗

Space payload dynamic testing

More cost effective methods for insuring payload reliability are required to efficiently utilize the projected payload capacity of future space systems such as the Space Shuttle. Studies are needed to better define the vibration environment of space vehicles to develop improved and more routine methods of testing and to develop better dynamic protection systems. Such improvements in environment definition, testing, and isolation will lead to less stringent design specification, improved payload reliability, fewer and more realistic qualification and flight acceptance tests. This paper presents current payload test philosophies, effectiveness of testing, and research needed to achieve more cost effective payload reliability for future applications.

Pinson, L. D.↗

New Functionality of Ionic Liquids as Lubricant Additives: Mitigating Rolling Contact Fatigue

Oil-soluble ionic liquids (ILs) have recently been demonstrated as effective lubricant additives of friction reduction and wear protection for sliding contacts. However, their functionality in mitigating rolling contact fatigue (RCF) is little known. Because of the distinct surface damage modes, different types of surface protective additives often are used in lubricants for sliding and rolling contacts. Therefore, the lubricating characteristics and mechanisms of ILs learned in sliding contacts from the earlier work may not be translatable to rolling contacts. This study explores the feasibility of using phosphonium-phosphate, ammonium-phosphate, and phosphonium-carboxylate ILs as candidate additives in rolling–sliding boundary lubrication, and results suggested that an IL could be either beneficial or detrimental on RCF depending on its chemistry. Particularly, the best-performing phosphonium-phosphate IL at 2% addition made a low-viscosity base oil significantly outperform a more viscous commercial gear oil in reducing the RCF surface damage and associated vibration noise. This IL generated a thicker, smoother, and more homogeneous tribofilm compared with commercial additives, which is likely responsible for the superior RCF protection. Results here suggest good potential for using appropriate IL additives to allow the use of low-viscosity gear and axle fluids for improved efficiency and durability.

36 MATERIALS SCIENCE↗

Analytical trade study of the STS payload environment

The current predicted acoustic environment for the shuttle orbiter payload bay will produce random vibration environments for payload components and subsystems which potentially will result in design, weight and cost penalties if means of protecting the payloads are not developed. Results are presented of a study to develop, through design and cost effectiveness trade studies, conceptual noise suppression device designs for space shuttle payloads. The impact of noise suppression on environmental levels and associated test costs, and on test philosophy for the various payload classes is considered with the ultimate goal of reducing payload test costs. Conclusions and recommendations are presented.

Rader, W. P.↗

Acousto-optic signature analysis for inspection of the orbiter thermal protection tile bonds

The goal of this research is to develop a viable NDE technique for the inspection of orbiter thermal protection system (TPS) tile bonds. Phase 2, discussed here, concentrated on developing an empirical understanding of the bonded and unbonded vibration signatures of acreage tiles. Controlled experiments in the laboratory have provided useful information on the dynamic response of TPS tiles. It has been shown that several signatures are common to all the pedigree tiles. This degree of consistency in the tile-SIP (strain isolation pad) dynamic response proves that an unbond can be detected for a known tile and establish the basis for extending the analysis capability to arbitrary tiles for which there are no historical data. The field tests of the noncontacting laser acoustic sensor system, conducted at the Kennedy Space Center (KSC), investigated the vibrational environment of the Orbiter Processing Facility (OPF) and its effect on the measurement and analysis techniques being developed. The data collected showed that for orbiter locations, such as the body flap and elevon, the data analysis scheme, and/or the sensor, will require modification to accommodate the ambient motion. Several methods were identified for accomplishing this, and a solution is seen as readily achievable. It was established that the tile response was similar to that observed in the laboratory. Of most importance, however, is that the field environment will not affect the physics of the dynamic response that is related to bond condition. All of this information is fundamental to any future design and development of a prototype system.

Rodriguez, Julio G.↗

Mechanical and Vibration Testing of Carbon Fiber Composite Material with Embedded Piezoelectric Sensors

Piezoelectric materials have been proposed as a means of decreasing turbomachinery blade vibration either through a passive damping scheme, or as part of an active vibration control system. For polymer matrix fiber composite (PMFC) blades, the piezoelectric elements could be embedded within the blade material, protecting the brittle piezoceramic material from the airflow and from debris. Before implementation of a piezoelectric element within a PMFC blade, the effect on PMFC mechanical properties needs to be understood. This study attempts to determine how the inclusion of a packaged piezoelectric patch affects the material properties of the PMFC. Composite specimens with embedded piezoelectric patches were tested in four-point bending, short beam shear, and flatwise tension configurations. Results show that the embedded piezoelectric material does decrease the strength of the composite material, especially in flatwise tension, attributable to failure at the interface or within the piezoelectric element itself. In addition, the sensing properties of the post-cured embedded piezoelectric materials were tested, and performed as expected. The piezoelectric materials include a non-flexible patch incorporating solid piezoceramic material, and two flexible patch types incorporating piezoelectric fibers. The piezoceramic material used in these patches was Navy Type-II PZT.

Duffy, Kirsten P.↗

SNAP 10A thermal control coatings.

SNAP-10A high emittance white coating, noting stability at 600 degrees F, irradiation and vacuum and mechanical vibration

SURFACE STABILITY↗

Resonance testing of space shuttle thermoacoustic structural specimen

The resonance testing of a structural specimen related to the space shuttle vehicle is described. The specimen consisted of a thin aluminum skin reinforced by hat-section stringers and supported by two ribs or bulkheads of corrugated web. A representative section of the space shuttle thermal protection system was bonded to the outer surface of the skin. The tests were completed by using miniature accelerometers to collect vibration data from locations forming a predetermined mesh over the tiles and base structure. The signals were recorded on FM magnetic tape and subsequently analyzed on a modal analysis system.

Abrahamson, A. L.↗

TU-EF-207-00: Advances in Breast Imaging

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Influence of soil-structure interaction on performance of a super tall building using a new eddy-current tuned mass damper

Tuned mass dampers (TMDs) can be used as vibration control devices to improve the vibration performance of high-rise buildings. The Shanghai Tower (SHT) is a 632-m high landmark building in China, featuring a new eddy-current TMD. Special protective mechanisms have been adopted to prevent excessively large amplitude of the TMD under extreme wind or earthquake loading scenarios. This paper presents a methodology for simulating behavior of the new eddy-current TMD that features displacement-dependent damping behavior. The TMD model was built into the SHT finite element model to perform frequency analysis and detailed response analyses under wind and earthquake loads. Furthermore, soil-structure interaction (SSI) effects on wind and seismic load responses of the SHT model were investigated, as SSI has a significant impact on the vibration performance of high-rise buildings. It was found that SSI has more significant effects on acceleration response for wind loads with a short return period than for wind loads with a long return period. Some of the acceleration responses with SSI effects exceed design limits of human comfort for wind loads with shorter return periods. As to the seismic analyses, it was found that SSI slightly reduces the displacement amplitude, the damping force, and the impact force of the TMD.

42 ENGINEERING↗

Preparation and magnetic properties of spindle porous iron nanoparticles

Spindle porous iron nanoparticles were firstly synthesized by reducing the pre-synthesized hematite ({alpha}-Fe{sub 2}O{sub 3}) spindle particles with hydrogen gas. The products were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), nitrogen adsorption/desorption isotherms and vibrating sample magnetometry (VSM). A lattice shrinkage mechanism was employed to explain the formation process of the porous structure, and the adsorbed phosphate was proposed as a protective shell in the reduction process. N{sub 2} adsorption/desorption result showed a Brunauer-Emmett-Teller (BET) surface area of 29.7 m{sup 2}/g and a continuous pore size distribution from 2 nm to 100 nm. The magnetic hysteresis loop of the synthesized iron particles showed a saturation magnetization of 84.65 emu/g and a coercivity of 442.36 Oe at room temperature.

36 MATERIALS SCIENCE↗

Vibration damping of the Cassini spacecraft structure

Cassini is a large robotic spacecraft currently under development at the Jet Propulsion Laboratory (JPL) whose interplanetary scientific mission is to explore Saturn, its ring, and its moons. Cassini is scheduled to launch on a Titan IV rocket with a Centaur upper stage booster, and will be protected during ascent through the atmosphere by a lightweight aluminum payload fairing (PLF). As a result of the extreme noise levels generated by the powerful Titan IV at liftoff, and the acoustic transparency of the PLF, Cassini is predicted to experience sever acoustic levels. Furthermore, the high acoustic levels, coupled with the size and configuration of the spacecraft, will induce unacceptable random vibration levels on the structure and critical spacecraft components. Studies showed that the use of Tuned Vibration Absorbers (TVAs) would be effective in reducing vibration. A series of reverberant acoustic tests were performed on a partial development test model (DTM) of Cassini to evaluate the effectiveness of TVAs in reducing the structural vibration. The test results showed that significant vibration attenuation was achieved.

vibration damping↗

The solar cells and their mounting

Objectives in development of the solar plant for the Telstar spacecraft were to provide a power source which would withstand launching stresses and the expected space environment, with optimum end-of-life performance. Radiation damage to the silicon solar cells is the primary factor limiting their useful life; the effect of energetic protons or electrons is the generation of recombination centers in the silicon which reduce the minority-carrier diffusion length and therefore the long-wave response of the cell. The spacecraft solar cells use the n-on-p structure, in preference to conventional p-on-n structure, to obtain a factor of 3 to 10 increased life expectancy. Response to light in the 0.4 to 0.7 micron range is enhanced by using a thin n-layer (about 0.5 micron) and an antireflection coating with minimum reflectance at 0.55 micron wavelength. Early estimates of electron and proton fluxes in the satellite orbit showed that even the best cells would not give sufficient life without radiation shielding. Therefore the cells are protected against electrons of energy up to 1 Mev by 0.3 gm/sq. cm sapphire cover plates. The cell mountings are designed to withstand peak vibration stresses of 200 g and repeated temperature cycles from +65°C to −100°C. The 3600-cell solar power plant is composed of 300 twelve-cell groups of 1 cm × 2 cm cells, yielding a nominal initial power of 14 watts at 28 volts for any spin-axis orientation relative to the sun. Telemetry information on performance of the solar plant indicates degradation of the shielded solar cells equal to that measured in the laboratory on unshielded cells with a 1-Mev normal incidence flux of 6 × 10^(12) electrons/(sq. cm day). From this comparison it is estimated that the plant will degrade to 68 per cent of its initial output after two years in orbit.

SPACECRAFT POWER SUPPLY↗

TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-04: Advances in Detector Technology for Breast Tomosynthesis

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

TU-EF-207-05: Dedicated Cone-beam Breast CT

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗