Search NASA⌕ Search

SEARCH · Search NASA

Results for “VICTORIA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Two Dual Ion Spectrometer Flight Units of the Fast Plasma Instrument Suite (FPI) for the Magnetospheric Multiscale Mission (MMS)

Two Dual Ion Spectrometer flight units of the Fast Plasma Instrument Suite (FPI) for the Magnetospheric Multiscale Mission (MMS) have returned to MSFC for flight testing. Anticipated to begin on June 30, tests will ensue in the Low Energy Electron and Ion Facility of the Heliophysics and Planetary Science Office (ZP13), managed by Dr. Victoria Coffey of the Natural Environments Branch of the Engineering Directorate (EV44). The MMS mission consists of four identical spacecraft, whose purpose is to study magnetic reconnection in the boundary regions of Earth's magnetosphere.

Adams, Mitzi↗

Strategic Analysis for the MER Cape Verde Approach

The Mars Exploration Rover Opportunity has recently completed a two year campaign studying Victoria Crater. The campaign culminated in a close approach of Cape Verde in order to acquire high resolution imagery of the exposed stratigraphy in the cliff face. The close approach to Cape Verde provided significant challenges for every subsystem of the rover as the rover needed to traverse difficult, uncharacterised terrain and approach a cliff face with the potential of blocking out solar energy and communications with Earth. In this paper we describe the strategic analyses performed by the science and engineering teams so that we could successfully achieve the science objectives while keeping the rover safe.

Mission Planning↗

Perchlorate and Volatiles of the Brine of Lake Vida (Antarctica): Implication for the in Situ Analysis of Mars Sediments

The cold (-13.4 C), cryoencapsulated, anoxic, interstitial brine of the 27 m-thick ice of Lake Vida (Victoria Valley, Antarctica) contains 49 microgram L-1 of perchlorate and 11 microgram L-1 of chlorate. Lake Vida brine (LVBr) may provide an analog for potential oxychlorine-rich subsurface brine on Mars. LVBr volatiles were analyzed by solid-phase microextraction (SPME) gas chromatography-mass spectrometry (GC-MS) with two different SPME fibers. With the exception of volatile organic sulfur compounds, most other volatiles observed were artifacts produced in the GC injector when the thermal decomposition products of oxychlorines reacted with reduced carbon derived from LVBr and the SPME fiber phases. Analysis of MilliQ water with perchlorate (40 microgram L-1) showed low level of organic artifacts, reflecting carbon limitation. In order to observe sample-derived organic compounds, both in analog samples and on Mars, the molar abundance of reduced carbon in a sample must exceed those of O2 and Cl2 produced during decomposition of oxychlorines. This suggests that the abundance of compounds observed by the Sample Analysis at Mars (SAM) instruments in Sheepbed samples (CB-3, CB5, and CB6) may be controlled by an increase in the reduced-carbon/oxychlorine ratio of these samples. To increase chances of in situ detection of Martian organics during pyrolysis-GC-MS, we propose that the derivatization agents stored on SAM may be used as an external source of reduced carbon, increasing artificially the reduced-carbon to perchlorate ratio during pyrolysis, allowing the expression of more abundant and perhaps more diverse Martian organic matter.

Mars analog experiment↗

Diurnal Cycle of IMERG V06 Precipitation

This study demonstrates the maturing ability of the half-hourly precipitation estimates from the Integrated Multi-satellitE Retrievals for GPM (IMERG) for use in global analyses of the diurnal cycle. The refined intercalibration and interpolation between the sensors in V06 leads to greater consistency in the precipitation retrievals over different hours of the day. Evaluation against ground measurements suggests a slight lag in the diurnal phase of only +0.59 h. We demonstrate the diurnal cycle over different regions around the globe, including the Maritime Continent, where accurate representation of precipitation variability in global models remains a challenge. Using examples over Singapore, Bangladesh, and Lake Victoria, we reveal the intricate interplay between diurnal and seasonal variability. This study demonstrates the unprecedented capability of IMERG in capturing the diurnal cycle of precipitation globally, potentially advancing our understanding in regions of sparse ground measurements and supporting improvements in its representation in global models.

Jackson Tan↗

Impact of Random and Periodic Surface Roughness on P- and L-band Radiometry

L-band passive microwave remote sensing is currently considered a robust technique for global monitoring of soil moisture. However, soil roughness complicates the relationship between brightness temperature and soil moisture, with current soil moisture retrieval algorithms typically assuming a constant roughness parameter globally, leading to a potential degradation in retrieval accuracy. This current investigation established a tower-based experiment site in Victoria, Australia. P-band (~40-cm wavelength/0.75 GHz) was compared with L-band (~21-cm wavelength/1.41 GHz) over random and periodic soil surfaces to determine if there is an improvement in brightness temperature simulation and soil moisture retrieval accuracy for bare soil conditions, due to reduced roughness impact when using a longer wavelength. The results showed that P-band was less impacted by random and periodic roughness than L-band, evidenced by more comparable statistics across different roughness conditions. The roughness effect from smooth surfaces (e.g., 0.8-cm root-mean-square height and 11.1-cm correlation length) could be potentially ignored at both P- and L-band with satisfactory simulation and retrieval performance. However, for rougher soil (e.g., 1.6-cm root-mean-square height and 6.8-cm correlation length), the roughness impact needed to be accounted for at both P- and L-band, with P-band observations showing less impact than L-band. Moreover, a sinusoidal soil surface with 10-cm amplitude and 80-cm period substantially impacted the brightness temperature simulation and soil moisture retrieval at both P- and L-band, which could not be fully accounted for using the SMOS and SMAP default roughness parameters. However, when retrieving roughness parameters along with soil moisture, the ubRMSE at P-band over periodic soil was improved to a similar level (0.01-0.02 m3/m3) as that of smooth flat soil (0.01 m3/m3), while L-band showed higher ubRMSE over the periodic soil (0.03-0.04 m3/m3) than over smooth flat soil (0.01 m3/m3). Accordingly, periodic roughness effects were reduced by using observations at P-band.

Soil roughness↗

Evaluation of the Tau-Omega Model Over Bare and Wheat-Covered Flat and Periodic Soil Surfaces at P- and L-band

It has been over ten years since the successful launch of the first-ever dedicated satellite for global soil moisture monitoring; Soil Moisture and Ocean Salinity (SMOS). Looking towards the future, P-band (0.3-1 GHz) is a promising technique to replace or enhance the L-band (1.4 GHz) SMOS and SMAP (Soil Moisture Active Passive) missions because of an expected reduction in roughness and vegetation impact, leading to an improved soil moisture accuracy over rougher soil surfaces and more densely vegetated areas. Accordingly, this investigation evaluated the tau-omega model at P-band (0.75 GHz) using a tower-based experiment in Victoria, Australia, where brightness temperature observations were collected concurrently at P- and L-band over bare and wheat-covered flat and periodic soil surfaces. The potential to retrieve soil moisture without discriminating periodic and flat surfaces was investigated by applying the roughness and vegetation parameters calibrated for flat soil to retrieve the moisture of periodic soil. Results showed that P-band had a comparable RMSE across different roughness configurations (variations less than 0.016 m3/m3) for both bare and wheat-covered soil, while the L-band RMSE was only comparable for wheat-covered soil, indicating that periodic surfaces did not need to be discriminated in such scenarios. Conversely, a difference of 0.022 m3/m3 was observed for L-band with bare soil. A reduced vegetation impact was also demonstrated at P-band, with an RMSE of 0.029 m3/m3 achieved when completely ignoring the wheat existence with under 4-kg/m2 vegetation water content, whereas at L-band the RMSE increased to 0.063 m3/m3. This study therefore paves the way for a successful P-band radiometer mission for obtaining more accurate global soil moisture information.

P-band↗

Drill-Site Selection for Cosmogenic-Nuclide Exposure Dating of the Bed of the Greenland Ice Sheet

Direct observations of the size of the Greenland Ice Sheet during Quaternary interglaciations are sparse yet valuable for testing numerical models of ice-sheet history and sea level contribution. Recent measurements of cosmogenic nuclides in bedrock from beneath the Greenland Ice Sheet collected during past deep-drilling campaigns reveal that the ice sheet was significantly smaller, and perhaps largely absent, sometime during the past 1.1 million years. These discoveries from decades-old basal samples motivate new, targeted sampling for cosmogenic-nuclide analysis beneath the ice sheet. Current drills available for retrieving bed material from the US Ice Drilling Program require < 700 m ice thickness and a frozen bed, while quartz-bearing bedrock lithologies are required for measuring a large suite of cosmogenic nuclides. We find that these and other requirements yield only ∼ 3.4 % of the Greenland Ice Sheet bed as a suitable drilling target using presently available technology. Additional factors related to scientific questions of interest are the following: which areas of the present ice sheet are the most sensitive to warming, where would a retreating ice sheet expose bare ground rather than leave a remnant ice cap, and which areas are most likely to remain frozen bedded throughout glacial cycles and thus best preserve cosmogenic nuclides? Here we identify locations beneath the Greenland Ice Sheet that are best suited for potential future drilling and analysis. These include sites bordering Inglefield Land in northwestern Greenland, near Victoria Fjord and Mylius-Erichsen Land in northern Greenland, and inland from the alpine topography along the ice margin in eastern and northeastern Greenland. Results from cosmogenic-nuclide analysis in new sub-ice bedrock cores from these areas would help to constrain dimensions of the Greenland Ice Sheet in the past.

Greenland↗

A Comparison of Passive Microwave Emission Models for Estimating Brightness Temperature at L- and P-band Under Bare and Vegetated Soil Conditions

P-band radiometry has been demonstrated to have a deeper sensing depth than at L-band, making the consideration of multi-layer microwave interactions necessary. Additionally, the scattering and phase interference effects are different at P-band, requiring a re-consideration of the need for coherent models. However, the impact remains to be clarified, and understanding the validity and limitations of these models at both L-band and P-band is crucial for their refinement and application. Therefore, two general categories of microwave emission models, including two stratified coherent models (Njoku and Wilhite) and four incoherent models (conventional tau-omega model and three multi-layer models being zero-order, first-order, and incoherent solution), were intercompared for the first time on the same dataset. This evaluation utilized observations of L-band and P-band radiometry under different land cover conditions from a tower-based experiment in Victoria, Australia. Model estimations of brightness temperature (TB) were consistent with measurements, with the lowest root mean square error (RMSE) at P-band V-polarization under corn (2 K) and the highest RMSE at L-band H-polarization under bare soil (13 K). Coherent models performed slightly better than incoherent models under bare soil (3 K less RMSE), while the opposite was true under vegetated soil conditions (1 K less RMSE). Coherent and incoherent models showed maximum differences (3 K at P-band, 2 K at L-band), correlating strongly with soil moisture variations at 0-10 cm. Findings suggest that coherent and incoherent models perform similarly; thus, incoherent models may be preferable for estimating TB at L- and P-band due to reduced computational complexity.

Soil moisture profile↗

Evaluation of the Tau-Omega Model over a Dense Corn Canopy at P- and L-band

As an emerging technique, P-band (0.3-1GHz) may improve soil moisture remote sensing compared to L-band (1.4 GHz) SMOS (Soil Moisture and Ocean Salinity) and SMAP (Soil Moisture Active Passive) missions, because of its greater moisture retrieval depth resulting from its longer wavelength. Consequently, a number of tower-based experiments were undertaken in Victoria, Australia, to understand and quantify potential improvements. The study reported here has extended the evaluation of the tau-omega model to a scenario with a dense corn canopy whose vegetation water content reached ~20 kg/m 2 , and compared the soil moisture retrieval performance at P- and L-band. Based on the locally calibrated parameters, the results from both the SCA (Single Channel Algorithm) and DCA (Dual Channel Algorithm) approaches presented a clear reduction in vegetation impact at P-band compared to L-band. While the root-mean-square error (RMSE) for P-band did not achieve the 0.04-m 3 /m 3 target accuracy of SMOS and SMAP, i.e., 0.054 m 3 /m 3 for the SCA and 0.074 m 3 /m 3 for the DCA, this performance can be regarded as acceptable considering the extremely high vegetation water content. In comparison, the RMSEs at L-band were larger than 0.1 m 3 /m 3 for both the SCA and the DCA approaches. Additionally, DCA performed better in correlation coefficient and unbiased RMSE, while SCA performed better in RMSE at P-band due to the larger bias when using DCA. Moreover, the calibrated vegetation parameters at P-band were found to apply to broader conditions than those at L-band, likely due to the reduced vegetation impact.

P-band↗

Nucleic acid encoding a self-assembling split-fluorescent protein system

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Nucleic acid encoding a self-assembling split-fluorescent protein system

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

Nucleic acid encoding a self-assembling split-fluorescent protein system

The invention provides a protein labeling and detection system based on self-complementing fragments of fluorescent and chromophoric proteins. The system of the invention is exemplified with various combinations of self-complementing fragments derived from Aequorea victoria Green Fluorescent Protein (GFP), which are used to detect and quantify protein solubility in multiple assay formats, both in vitro and in vivo.

59 BASIC BIOLOGICAL SCIENCES↗

PERI - Auto-tuning Memory Intensive Kernels for Multicore

We present an auto-tuning approach to optimize application performance on emerging multicore architectures. The methodology extends the idea of search-based performance optimizations, popular in linear algebra and FFT libraries, to application-specific computational kernels. Our work applies this strategy to Sparse Matrix Vector Multiplication (SpMV), the explicit heat equation PDE on a regular grid (Stencil), and a lattice Boltzmann application (LBMHD). We explore one of the broadest sets of multicore architectures in the HPC literature, including the Intel Xeon Clovertown, AMD Opteron Barcelona, Sun Victoria Falls, and the Sony-Toshiba-IBM (STI) Cell. Rather than hand-tuning each kernel for each system, we develop a code generator for each kernel that allows us to identify a highly optimized version for each platform, while amortizing the human programming effort. Results show that our auto-tuned kernel applications often achieve a better than 4X improvement compared with the original code. Additionally, we analyze a Roofline performance model for each platform to reveal hardware bottlenecks and software challenges for future multicore systems and applications.

97 MATHEMATICS AND COMPUTING↗

Design of a Highly Specific And Noninvasive Biosensor Suitable for Real-Time in Vivo Imaging of Mercury (II) Uptake

Mercury is a ubiquitous pollutant that when absorbed is extremely toxic to a wide variety of biochemical processes. Mercury (II) is a strong, invisible poison that is rapidly absorbed by tissues of the intestinal tract, kidneys, and liver upon ingestion. In this study, a novel fluorescence-based biosensor is presented that allows for the direct monitoring of the uptake and distribution of the metal under noninvasive in vivo conditions. With the introduction of a cysteine residue at position 205, located in close proximity to the chromophore, the green fluorescent protein (GFP) from Aequorea victoria was converted into a highly specific biosensor for this metal ion. The mutant protein exhibits a dramatic absorbance and fluorescence change upon mercuration at neutral pH. Absorbance and fluorescence properties with respect to the metal concentration exhibit sigmoidal binding behavior with a detection limit in the low nanomolar range. Time-resolved binding studies indicate rapid subsecond binding of the metal to the protein. The crystal structures obtained of mutant eGFP205C indicate a possible access route of the metal into the core of the protein. To our knowledge, this engineered protein is a first example of a biosensor that allows for noninvasive and real-time imaging of mercury uptake in a living cell. A major advantage is that its expression can be genetically controlled in many organisms to enable unprecedented studies of tissue specific mercury uptake.

36 MATERIALS SCIENCE↗

The U-tube sampling methodology and real-time analysis of geofluids

The U-tube geochemical sampling methodology, an extension of the porous cup technique proposed by Wood [1973], provides minimally contaminated aliquots of multiphase fluids from deep reservoirs and allows for accurate determination of dissolved gas composition. The initial deployment of the U-tube during the Frio Brine Pilot CO{sub 2} storage experiment, Liberty County, Texas, obtained representative samples of brine and supercritical CO{sub 2} from a depth of 1.5 km. A quadrupole mass spectrometer provided real-time analysis of dissolved gas composition. Since the initial demonstration, the U-tube has been deployed for (1) sampling of fluids down gradient of the proposed Yucca Mountain High-Level Waste Repository, Armagosa Valley, Nevada (2) acquiring fluid samples beneath permafrost in Nunuvut Territory, Canada, and (3) at a CO{sub 2} storage demonstration project within a depleted gas reservoir, Otway Basin, Victoria, Australia. The addition of in-line high-pressure pH and EC sensors allows for continuous monitoring of fluid during sample collection. Difficulties have arisen during U-tube sampling, such as blockage of sample lines from naturally occurring waxes or from freezing conditions; however, workarounds such as solvent flushing or heating have been used to address these problems. The U-tube methodology has proven to be robust, and with careful consideration of the constraints and limitations, can provide high quality geochemical samples.

54 ENVIRONMENTAL SCIENCES↗

Optimization of Sparse Matrix-Vector Multiplication on Emerging Multicore Platforms

We are witnessing a dramatic change in computer architecture due to the multicore paradigm shift, as every electronic device from cell phones to supercomputers confronts parallelism of unprecedented scale. To fully unleash the potential of these systems, the HPC community must develop multicore specific-optimization methodologies for important scientific computations. In this work, we examine sparse matrix-vector multiply (SpMV) - one of the most heavily used kernels in scientific computing - across a broad spectrum of multicore designs. Our experimental platform includes the homogeneous AMD quad-core, AMD dual-core, and Intel quad-core designs, the heterogeneous STI Cell, as well as one of the first scientific studies of the highly multithreaded Sun Victoria Falls (a Niagara2 SMP). We present several optimization strategies especially effective for the multicore environment, and demonstrate significant performance improvements compared to existing state-of-the-art serial and parallel SpMV implementations. Additionally, we present key insights into the architectural trade-offs of leading multicore design strategies, in the context of demanding memory-bound numerical algorithms.

97 MATHEMATICS AND COMPUTING↗

Stencil Computation Optimization and Auto-tuning on State-of-the-Art Multicore Architectures

Understanding the most efficient design and utilization of emerging multicore systems is one of the most challenging questions faced by the mainstream and scientific computing industries in several decades. Our work explores multicore stencil (nearest-neighbor) computations -- a class of algorithms at the heart of many structured grid codes, including PDE solvers. We develop a number of effective optimization strategies, and build an auto-tuning environment that searches over our optimizations and their parameters to minimize runtime, while maximizing performance portability. To evaluate the effectiveness of these strategies we explore the broadest set of multicore architectures in the current HPC literature, including the Intel Clovertown, AMD Barcelona, Sun Victoria Falls, IBM QS22 PowerXCell 8i, and NVIDIA GTX280. Overall, our auto-tuning optimization methodology results in the fastest multicore stencil performance to date. Finally, we present several key insights into the architectural trade-offs of emerging multicore designs and their implications on scientific algorithm development.

97 MATHEMATICS AND COMPUTING↗

Another Nobel Prize linked to synchrotron radiation work

The 2008 Nobel Prize in Chemistry went to Osamu Shimomura, Martin Chalfie and Roger Tsien 'for the discovery and development of the green fluorescent protein, GFP'. This year's Nobel Prize in Chemistry rewards the initial discovery of GFP and a series of important developments which have led to its use as a tagging tool in bioscience. By using DNA technology, researchers can now connect GFP to other interesting, but otherwise invisible, proteins. This glowing marker allows the movements, positions and interactions of the tagged proteins to be monitored. Osamu Shimomura was the first to isolate GFP from the jellyfish Aequorea victoria, found off the west coast of North America, and discovered the protein's green glow [Shimomura et al. (1962). J. Cell. Comp. Physiol. 59, 223-240]. Martin Chalfie demonstrated the value of GFP as a luminous genetic tag. In one of his first experiments he coloured six individual cells in the transparent roundworm Caenorhabditis elegans with the aid of GFP. He had obtained the GFP gene (gfp) clone from Prasher [Prasher et al. (1992). Gene, 111, 229-233] and expressed it in E. coli. The GFP protein displayed a bright green fluorescence in this heterologous organism, suggesting that it could indeed serve as a versatile genetic marker in virtually all organisms. Chalfie transformed C. elegans with gfp under the control of a promoter regulating the expression of {beta}-tubulin, abundant in six touch receptor neurons in C. elegans. The organism subsequently expressed GFP from distinct positions in its body and at distinct times in its development [Chalfie et al. (1994). Science, 263, 802-805]. Roger Tsien contributed to the general understanding of how GFP glows by determining the formation of the GFP chromophore, a chemical group that absorbs and emits light. Tsien is best known for extending the colour palette of GFP beyond green, allowing researchers to follow several different biological processes at the same time. According to background on the Nobel Prize website, 'An important step forward, allowing for rational design of mutants, was the solution of the crystal structure of GFP.' Tsien collaborated with Jim Remington and his team who solved the structure of GFP at 1.9 {angstrom} using data in part collected at NSLS beamline X4A. Tsien and Remington were able to use the structural information and design specific mutants (Thr203, to Tyr or His) which resulted in significantly red-shifted excitation and emission maxima and thus converting GFP into YFP (yellow fluorescence protein) [Ormo et al. (1996). Science, 273, 1392-1395]. Acknowledging the contribution of NSLS Brookhaven, University of Oregon scientist Remington said 'The data collected at beamline X4A were essential to solve the structure of GFP. We were unable to solve the structure using native and heavy-atom-derivative data sets collected at home'. Remington added 'In those days the technology to flash freeze crystals had not been fully worked out and so diffraction data had to be collected at temperatures above freezing. Crystal lifetime was very short. At X4A, a crystal cooling system enabled data collection at close to zero degrees Celsius, extending the crystal lifetime, while the intense beam permitted data to be collected at significantly higher resolution. In addition, the tunable nature of the source allowed us to collect data at the selenomethionine absorption edge, which dramatically improved the signal for phasing purposes. The improved phasing, combined with higher resolution data, resulted in an interpretable electron density map. The first look at the GFP chromophore in that electron density map was one of the most exciting moments of my entire career.'

36 MATERIALS SCIENCE↗