Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Surface voltage gradient role in high voltage solar array-plasma interaction: Center Director's discretionary fund

A large amount of experimental and analytical effort has been directed toward understanding the plasma sheath growth and discharge phenomena which lead to high voltage solar array-space plasma interactions. An important question which has not been addressed is how the surface voltage gradient on such an array may affect these interactions. The results of this study indicate that under certain conditions, the voltage gradient should be taken into account when evaluating the effect on a solar array operating in a plasma environment.

Carruth, M. R., Jr.↗

Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unravelling the origin of irreversible capacity loss in NaNiO 2 for high voltage sodium ion batteries

Layered transition metal compounds have attracted much attention due to their high theoretical capacity and energy density for sodium ion batteries. However, this kind of material suffers from serious irreversible capacity decay during the charge and discharge process. Here, using synchrotron-based operando transmission X-ray microscopy and high-energy X-ray diffraction combined with electrochemical measurements, the visualization of the dissymmetric phase transformation and structure evolution mechanism of layered NaNiO2 material during initial charge and discharge cycles are clarified. Phase transformation and deformation of NaNiO2 during the voltage range of below 3.0 V and over 4.0 V are responsible for the irreversible capacity loss during the first cycling, which is also confirmed by the evolution of reaction kinetics behavior obtained by the galvanostatic intermittent titration technique. These findings reveal the origin of the irreversibility of NaNiO2 and offer valuable insight into the phase transformation mechanism, which will provide underlying guidance for further development of high-performance sodium ion batteries.

high voltage↗

Effect of electrolyte composition on rock salt surface degradation in NMC cathodes during high-voltage potentiostatic holds

Surface degradation of lithium-ion cathodes at high voltages represents a significant barrier to increasing the useable energy of conventional cathodes. Though much work has been focused on mitigating the detrimental effects of such phenomena, the complex and correlated mechanisms involved have made progress difficult. Herein, the effect of electrolyte identity on surface degradation is examined. LiNi0.5Mn0.3Co0.2O2 (NMC532)/Li4Ti5O12 (LTO) full cells were constructed using three different electrolytes: a baseline organic carbonate electrolyte, a baseline organic carbonate electrolyte with an oxidizable additive, and a fluorinated carbonate electrolyte. Each system was subjected to a 60 h potentiostatic hold at 3.05 V (4.6 V vs. Li+/Li) and subsequently deconstructed for characterization via transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS). Molecular simulations were carried out on each distinct component of the three electrolytes in contact with crystal surfaces of an NMC532 particle. Results indicate an affinity for the additive-containing electrolyte to extract atomic oxygen from the cathode surface, whereas the fluorinated electrolyte components have negligible interactions. Hydrogen abstraction from the baseline electrolyte is facilitated by the NMC532 surface. TEM analysis of cathode surfaces, after the potentiostatic holds, revealed that the NMC532 particles cycled with the additive-containing electrolyte underwent significant surface degradation, including changes to local crystal structure in a region penetrating 20-40 nm from the surface; consistent with oxygen and lithium loss from the cathode material. However, the NMC532 in contact with the fluorinated electrolyte showed a disordered layer of just a few nm in thickness, similar to the depth of crystal disorder observed in pristine NMC532 primary particles. EELS data of the oxygen K-edge also indicated transition metal (TM) reduction, consistent with oxygen loss and changes in crystal structure extending into the cathode surface for each of the electrolytes surveyed. These surface reactions, including oxygen loss, are shown to correlate well with elevated oxidation currents and surface reconstructions of cathode particles.

cathode/electrolyte interface↗

Local Voltage Control in Distribution Networks: A Game-Theoretic Perspective

Inverter-based voltage regulation is gaining importance to alleviate emerging reliability and power-quality concerns related to distribution systems with high penetration of photovoltaic (PV) systems. This paper seeks contribution in the domain of reactive power compensation by establishing stability of local Volt/VAr controllers. In lieu of the approximate linear surrogate used in the existing work, the paper establishes existence and uniqueness of an equilibrium point using nonlinear AC power flow model. Key to this end is to consider a nonlinear dynamical system with non-incremental local Volt/VAr control, cast the Volt/VAr dynamics as a game, and leverage the fixed-point theorem as well as pertinent contraction mapping argument. Numerical examples are provided to complement the analytical results.

14 SOLAR ENERGY↗

On the Efficacy of Repeat Voltage Holds for Conditioning and Calendar Life Testing of Graphite and Silicon Cells

Voltage-hold (V-hold) protocols have shown promise toward calendar lifetime analysis of cells with graphite (Gr) and silicon (Si) anodes. In this work, repeat V-holds are performed on Gr and Si cells paired with lithium iron phosphate cathodes to delineate their beneficial role in formation and conditioning. We find that V-hold at the top of charge supplements constant current cycling in conditioning the cell to higher capacities for both Gr and Si cells after the first V-hold. A reduced order model provides the irreversible capacity proportions of each V-hold. With each repeat V-hold, parasitic loss of lithium to the solid electrolyte interphase (SEI) decreases on both Gr and Si cells. Gr cells show the square-root-of-time capacity loss behavior within 200 h of V-hold, indicative of its fast relaxation and low impact of reference performance test cycles on the SEI growth. Lifetime estimates from repeat V-holds on Gr can reach years. Si exhibits longer transition times from kinetic to diffusion-limited SEI growth, evidenced by the 400 h and 200 h holds showing square-root-of-time and linear behavior, respectively. Lifetime predictions from repeat V-holds on Si only reach 1–2 months, highlighting its limitations. Recommended duration of V-holds for Si cells should be ≥400 h.

25 ENERGY STORAGE↗

Caution Is Required in Interpretation of Mutations in the Voltage Sensing Domain of Voltage Gated Channels as Evidence for Gating Mechanisms

The gating mechanism of voltage sensitive ion channels is generally considered to be the motion of the S4 transmembrane segment of the voltage sensing domains (VSD). The primary supporting evidence came from R→C mutations on the S4 transmembrane segment of the VSD, followed by reaction with a methanethiosulfonate (MTS) reagent. The cys side chain is –SH (reactive form –S−); the arginine side chain is much larger, leaving space big enough to accommodate the MTS sulfonate head group. The cavity created by the mutation has space for up to seven more water molecules than were present in wild type, which could be displaced irreversibly by the MTS reagent. Our quantum calculations show there is major reorientation of three aromatic residues that face into the cavity in response to proton displacement within the VSD. Two phenylalanines reorient sufficiently to shield/unshield the cysteine from the intracellular and extracellular ends, depending on the proton positions, and a tyrosine forms a hydrogen bond to the cysteine sulfur with its side chain –OH. These could produce the results of the experiments that have been interpreted as evidence for physical motion of the S4 segment, without physical motion of the S4 backbone. The computations strongly suggest that the interpretation of cysteine substitution reaction experiments be re-examined in the light of these considerations.

Biochemistry & Molecular Biology↗

Effects of cycling temperatures on the voltage fade phenomenon in 0.5Li 2 MnO 3 ·0.5LiNi 0.375 Mn 0.375 Co 0.25 O 2 cathodes

The rate of voltage fade in 0.5Li2MnO3•0.5LiNi0.375Mn0.375Co0.25O2 cathodes was measured in half-cells in a temperature range of 25 to 55°C. On the basis of the dependence of the values of the open-circuit potential with cycle count and temperature, the voltage fade phenomenon seems to consist of two chemical processes: one that can be described using a parabolic rate law and another that uses a linear-with-time law. As the cycling temperature increased, the relative contributions of the two processes changed. On the basis of the overall rate versus temperature data, we believe the two processes may be in competition with one another.

kinetics↗

Equivalent Circuit Models of Voltage-Controlled Dual Active Bridge Converters: Preprint

In this paper, we introduce a new method of modeling voltage-controlled dual active bridge converters as equivalent circuits. What makes the proposed model unique is that the entire closed loop system converter and control are represented together in one equivalent circuit. Since the full system can be recast as a circuit, this allows for deeper insights on how the closed-loop system performs and for the direct application of circuit analysis techniques. In particular, we reveal how classical control notions can be understood as circuit laws.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Solar Cell Quality Using Voltage Metrics: Preprint

The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one stepfurther, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how itcan be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

14 SOLAR ENERGY↗

Direct nanoscale mapping of open circuit voltages at local back surface fields for PERC solar cells

The open circuit voltage (V OC) is a critical and common indicator of solar cell performance as well as degradation, for panel down to lab-scale photovoltaics. Detecting V OC at the nanoscale is much more challenging, however, due to experimental limitations on spatial resolution, voltage resolution, and/or measurement times. Accordingly, in this work an approach based on Conductive Atomic Force Microscopy is implemented to directly detect the local V OC , notably for monocrystalline Passivated Emitter Rear Contact (PERC) cells which are the most common industrial-scale solar panel technology in production worldwide. This is demonstrated with cross-sectioned monocrystalline PERC cells around the entire circumference of a poly-Aluminum-Silicide via through the rear emitter. The V OC maps reveal a local Back Surface Field extending ~2 μm into the underlying p-type Si absorber due to Al in-diffusion as designed. Such high spatial resolution methods for photovoltaic performance mapping are especially promising for directly visualizing the effects of processing parameters, as well as identifying signatures of degradation for silicon and other solar cell technologies.

14 SOLAR ENERGY↗

Calculation of the Gating Charge for the Kv1.2 Voltage-Activated Potassium Channel

The atomic models of the Kv1.2 potassium channel in the active and resting state, originally presented elsewhere, are here refined using molecular dynamics simulations in an explicit membrane-solvent environment. With a minor adjustment of the orientation of the first arginine along the S4 segment, the total gating charge of the channel determined from >0.5 μs of molecular dynamics simulation is ~12–12.7 e, in good accord with experimental estimates for the Shaker potassium channel, indicating that the final models offer a realistic depiction of voltage-gating. In the resting state of Kv1.2, the S4 segment in the voltage-sensing domain (VSD) spontaneously converts into a 3 10 helix over a stretch of 10 residues. The 3 10 helical conformation orients the gating arginines on S4 toward a water-filled crevice within the VSD and allows salt-bridge interactions with negatively charged residues along S2 and S3. Free energy calculations of the fractional transmembrane potential, acting upon key charged residues of the VSD, reveals that the applied field varies rapidly over a narrow region of 10–15 Å corresponding to the outer leaflet of the bilayer. The focused field allows the transfer of a large gating charge without translocation of S4 across the membrane.

Biophysics↗

Propagation of non-Gaussian voltage angle fluctuations in high-voltage power grids

Recent measurements have reported non-Gaussian tails in the distribution of frequency data in electric power grids. Large frequency deviations may induce grid instabilities and it is therefore crucial to understand how noise disturbances with long, non-Gaussian tails propagate. Here, we investigate how fluctuations in power feed-in, characterized by non-zero cumulants of their distribution, propagate through high-voltage power grids. Unlike previous investigations which focused on the white-noise limit, we consider the limit of long noise correlation time, where power feed-in fluctuates over times longer than the inherent dynamical time scales of the grid - the relevant regime for large-scale, high-voltage distribution grids. In this work, we show that in this limit, the skewness and kurtosis of the power feed-in distribution propagate similarly as its variance, independently of the distribution of inertia. Non-Gaussianities from individual sources of noise therefore persist throughout the entire network. This finding is corroborated by numerical results on a realistic model of the synchronous grid of continental Europe.

42 ENGINEERING↗