Search NASA⌕ Search

SEARCH · Search NASA

Results for “Validation Readiness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Is the testing effect ready to be put to work? Evidence from the laboratory to the classroom.

The testing effect refers to the benefits to retention that result from structuring learning activities in the form of a test. As educators consider implementing test-enhanced learning paradigms in real classroom environments, we think it is critical to consider how an array of factors affecting test-enhanced learning in laboratory studies bear on test-enhanced learning in real-world classroom environments. As such, this review discusses the degree to which test feedback, test format (of formative tests), number of tests, level of the test questions, timing of tests (relative to initial learning), and retention duration have import for testing effects in ecologically valid contexts (e.g., classroom studies). Attention is also devoted to characteristics of much laboratory testing-effect research that may limit translation to classroom environments, such as the complexity of the material being learned, the value of the testing effect relative to other generative learning activities in classrooms, an educational orientation that favors criterial tests focused on transfer of learning, and online instructional modalities. We consider how student-centric variables present in the classroom (e.g., cognitive abilities, motivation) may have bearing on the effects of testing-effect techniques implemented in the classroom. We conclude that the testing effect is a robust phenomenon that benefits a wide variety of learners in a broad array of learning domains. Still, studies are needed to compare the benefit of testing to other learning strategies, to further characterize how individual differences relate to testing benefits, and to examine whether testing benefits learners at advanced levels.

60 APPLIED LIFE SCIENCES↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation Center for Runaway Electron Avoidance and Mitigation (SCREAM SciDAC) (Technical Final Report)

Runaway electrons can severely damage the plasma facing components on ITER during a major disruption and pose a major risk for tokamak fusion. It has been recognized that an adequate disruption mitigation system (DMS) is essential for the safe operation of ITER. The United States is responsible for the design and implementation of the disruption mitigation system on ITER, and in July 2016 the Simulation Center for Runaway Electron Avoidance and Mitigation (SCREAM) was launched by DOE, in a joint Fusion Energy Sciences (FES) and Advanced Scientific Computing Research (ASCR) collaboration. SCREAM was a comprehensive theory and simulation SciDAC center that provided physics guidance in the avoidance and mitigation of runaway electrons, and in tandem with domestic and international experiments, helped establish the qualitative and quantitative bases for safe operational scenarios and viable mitigation techniques. The SCREAM center assembled a national team of experts in runaway electron physics, tokamak disruptions, magnetohydrodynamic (MHD) simulation, and advanced algorithms and computing. The team combined advanced simulation and analysis capability facilitated by direct participation of ASCR SciDAC institutes with theoretical models and code development by FES scientists to focus on the runaway risk for ITER and tokamaks in general. The research scope was focussed on integrated simulations of kinetic runaway electrons, including MHD and fluid models of impurity transport, within a research plan guided by theory. The specific research tasks were (1) establish the fundamental physics of runaway generation, saturation, and dynamical evolution in a tokamak; (2) examine the critical path toward runaway avoidance; and (3) investigate the viability and effectiveness of the leading candidate schemes for runaway mitigation. In all three areas, members of the team carried out scoping studies that established the readiness for rapid and critical advances, especially in the deployment and further development of large-to extreme-scale simulation tools. Our multi-pronged computational approach included (1) relativistic Fokker-Planck solvers with discretization in phase space, (2) self-consistent particle-in-cell techniques, (3) particle-based Monte-Carlo, and (4) MHD-particle hybrid simulations. Cross-check between these different methods provided an additional means for verification and further bolstered the fidelity of our physics prediction. Validation against experimental results brings confidence to the predictive capability for ITER and frequently leads to new ideas for understanding and mitigating the thermal quench driven runaway electron phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing and Validation of Wireless Communication Architecture for Heliostat Fields: SIPS Final Report

This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.

14 SOLAR ENERGY↗

“Third-body” collision parameters for hydrocarbons, alcohols, and hydroperoxides and an effective internal rotor approach for estimating them

Collision rate constants and third-body collision efficiencies are calculated for more than 300 alkanes, alcohols, and hydroperoxides, for the bath gases He, Ar, H 2 , and N 2 , and from 300 to 2000 K. The data set includes highly branched species and species with as many as 16 nonhydrogen atoms N , and it is analyzed to develop strategies for estimating collision properties more generally. Simple analytic formulas describing the Lennard-Jones collision parameters $σ$ and $ε$ are obtained for each of the three classes of systems as a function of N . Trends in the collision efficiency range parameter $α$ = $\langle$Δ E d $\rangle$ are more complicated, and a method is developed and validated for estimating $α$ based on the numbers and types of internal rotors and oxygen-containing groups. Specifically, the approach maps the expected value of $α$ for a branched alkane, alcohol, or hydroperoxide onto those for the corresponding normal (linear) series via an effective number of nonhydrogen atoms N eff . The prescription for N eff is based on counting internal rotor types and is shown to be insensitive to temperature and fairly insensitive to the identity of the bath gas. Together, these strategies allow for the ready estimation of the collision parameters $σ$, $ε$, and $α$ so long as results for the associated linear series are available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Operability of a Pressurized Oxy Combustion System

Fossil fuel powers more than two-thirds of the world’s electricity, a significant share of which is derived from coal power plants. Despite coal being an abundant and energy-rich fuel, the major halt to its progress is greenhouse gas emissions. Pressurized oxy-combustion cycles can achieve theoretically high thermal efficiencies along with a 90% carbon capture rate. Additionally, the high energy density allows smaller turbomachinery and save capital cost. Thus, the primary objective of this dissertation is to present the design and operability of a pressurized oxy-combustor system. The initial part of the dissertation investigates different thermodynamic cycles and presents a model that can be adapted for existing power plants. The thermodynamic model will be used in the later part to design the proposed combustor. The two cycles analyzed are ENEL and TIPS. This study focuses on qualitative analyses of the cycles using a commercially available software called Aspen Plus®. A detailed benchmark study has been performed to validate the modeling process. ENEL and TIPS cycles are designed in the software, adopting the same principles. Recirculation ratio and pressures are varied to find the efficiency range of the cycles. Power calculations are done to find overall and net efficiency for a fixed recirculation ratio. The efficiencies of the cycles are compared to select an optimum cycle. A recirculation ratio of 50% is selected for implementation. The comparison shows that ENEL is marginally efficient over TIPS, at the cost of a pressure difference of about 70bars. Technology Readiness Level analysis is performed to present the availability of the specialized equipment for the cycles. From the TRL analysis, it is seen that the cost and availability of high viii pressure equipment surmount the edge of TIPS over ENEL. Thus, ENEL is chosen as the better cycle for investigating a scaled experiment considering efficiency and viability. The later part of the dissertation focuses on developing the combustor's design for a pressurized oxy-combustion cycle. The proposed combustor is a powerhead-mounted design aimed to produce 1MW of thermal outputThe different aspects of the design of a down-fired pressurized swirl combustor are presented in this dissertation.

Chowdhury, Mehrin↗

Let’s Get Real: Are Wearable Plant Sensors Ready for Crop Monitoring?

In recent years, the number of publications describing new and exciting developments in wearable plant sensors (WPSs) has skyrocketed. These small, lightweight sensors hold promise to assist precision agriculture and may thus help reduce crop losses, increase resource use efficiency, and automate crop production. However, WPSs are often not adequately tested in environments relevant for crop growth, and the majority of experimental WPS studies reveal a glaring lack of basic knowledge of plant biology. This review aims to bridge the communication gap between WPS developers and the wider plant research community by (1) providing essential physiological and environmental background information for engineers in relation to WPS sensing capabilities, (2) offering a step-by-step guide to conduct sensor tests on plants correctly, and (3) highlighting potential challenges and suggesting WPS applications in the open field, greenhouses, and vertical farming systems. We hope this review facilitates the development of WPSs and guides them to be truly “ready for the world”.

crop monitoring↗

Coupling of Pronghorn and RELAP-7 for a Pebble Bed Reactor

High temperature gas cooled reactors (HTGR) are a candidate for timely Gen-IV reactor technology deployment because of high technology readiness and walk-away safety. Among HTGRs, pebble bed reactors (PBRs) have attractive features such as low excess reactivity and online refueling. Pebble bed reactors pose unique challenges to analysts and reactor designers such as continuous burnup distribution depending on pebble motion and recirculation, radiative heat transfer across a variety of gas-filled gaps, and long design basis transients such as pressurized and depressurized loss of forced circulation. Modeling and simulation is essential for both the PBR’s safety case and design process. In order to verify and validate the new generation codes the Nuclear Energy Agency (NEA) Data bank provide a set of benchmarks data together with solutions calculated by the participants using the state of the art codes of that time. An important milestone to test the new PBR simulation codes is the OECD NEA PBMR-400 benchmark which includes thermal hydraulic and neutron kinetic standalone exercises as well as coupled exercises and transients scenarios. In this work, the reactor multiphysics code MAMMOTH and the thermal hydraulics code Pronghorn, both developed by the Idaho National Laboratory (INL) within the multiphysics object-oriented simulation environment (MOOSE), have been used to solve Phase 1 exercises 1 and 2 of the PBMR-400 benchmark. The steady state results are in agreement with the other participants’ solutions demonstrating the adequacy of MAMMOTH and Pronghorn for simulating PBRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Transformational Solid Oxide Fuel Cell (SOFC) Technology

This project was conducted under the Co-operative Agreement No. DE-FE0027584 with the US Department Energy to developed advanced Solid Oxide Fuel Cell (SOFC) Technologies. The overall objective of this project was to advance SOFC technology at the cell and stack level to enhance cell robustness and durability, increase performance, and reduce balance-of-plant (BOP) requirements. By reducing system complexity combined with the increases in power density and efficiency, the ultimate goal of the project was to increased reliability and to reduce capital and operating costs of installed systems. The project was focused on pathways that will reduce the cost of the SOFC cell and stack, including the following areas: Robust, redox tolerant cell technology Lower cost cell manufacturing through advances in cell design, which will reduce the amount of material, energy and time used in the fabrication of SOFCs High performance, low temperature electrolyte based on improvement of established materials Innovative SOFC stack architecture which truly integrates Balance of Plant functionality into the stack level design Thermal management of the fuel cell stack for increased durability and expanded window of operation Novel stack design amenable for use in sub-MW to multi-MW-scale power plants and having low replacement cost The incorporation of balance-of-plant (BOP) equipment into the stack platform increased the economic viability of smaller scale systems. The project objectives were met by a multi-prong approach, including new cell design complemented with modifications to existing cell technology, as well as a new stack design incorporating components typically included in the BOP, such as heat exchangers, oxidizer, fuel reformers, and recycle systems. The project culminated with demonstration of a stack test validating the viability of the cell and stack improvements. A cost model was also developed to estimate costs for the advanced stack technology at high volume manufacturing levels. The net outcome of the project is SOFC cell and stack technology with costs significantly below current DOE targets without compromising and, in some cases, improving on the performance and degradation rate demonstrated with the current state-of-the-art stack design. The results of this project advanced the reliability, robustness, and endurance of low-cost SOFC technology that ultimately are ready to be deployed in coal power systems with greater than 60 percent efficiency (based on higher heating value of fuel) and the capability for ≥97% CO 2 capture at a cost-of-electricity that is approximately 40 percent below presently available Integrated Gasification Combined Cycle systems.

03 NATURAL GAS↗

A FAIR and AI-ready Higgs boson decay dataset

Abstract To enable the reusability of massive scientific datasets by humans and machines, researchers aim to adhere to the principles of findability, accessibility, interoperability, and reusability (FAIR) for data and artificial intelligence (AI) models. This article provides a domain-agnostic, step-by-step assessment guide to evaluate whether or not a given dataset meets these principles. We demonstrate how to use this guide to evaluate the FAIRness of an open simulated dataset produced by the CMS Collaboration at the CERN Large Hadron Collider. This dataset consists of Higgs boson decays and quark and gluon background, and is available through the CERN Open Data Portal. We use additional available tools to assess the FAIRness of this dataset, and incorporate feedback from members of the FAIR community to validate our results. This article is accompanied by a Jupyter notebook to visualize and explore this dataset. This study marks the first in a planned series of articles that will guide scientists in the creation of FAIR AI models and datasets in high energy particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Structured Adsorbent Architectures for Transformative Carbon Dioxide Capture Performance (Final Report)

Svante is a world leader at using solid sorbents for low-cost Carbon Dioxide (CO 2 ) capture, a technology which is recognized as critical in meeting the dual mandates of energy security/reliability and the mitigation of man-made CO 2 emissions. Svante has been developing proprietary adsorbent material compositions, forming them into structured laminates, developing and optimizing process cycles, and system design for efficient capture of CO 2 from post-combustion flue gases of thermal power plants and industrial facilities. The deployment of first-generation CO 2 capture technology has been significantly hampered by high costs and energy penalties, among other barriers. Second generation CO 2 capture technologies (including the Mark I variant of Svante’s Veloxotherm™ adsorption-based technology), utilizing single adsorbent architecture, show promise for reducing the barriers to deploying CO 2 capture plants in commercially meaningful numbers. The objective of this project was to evaluate the Recipient’s transformational (Mark-II) VeloxoTherm™ Technology via the development and bench-scale testing of an advanced structured adsorbent, including novel Bi-layer, laminated adsorbent structures and segmented beds. Svante selected, synthesized, and characterized tailored solid adsorbents for computational modeling, advanced structured adsorbent development, process simulations, and dynamic bench scale (~1-10 kg/day CO 2 captured) testing using an existing single-bed VeloxoTherm™ Station (VTS) coupled with a natural gas-fired boiler. Segmented beds used the in-house, multi-bed Process Demonstration Unit (PDU) to demonstrate key performance indicators (KPIs), such as recovery, product purity, regeneration energy, and the integrated system's productivity in lifetime analysis. Segmented beds were used at a 1 tonne per day (TPD) unit at an industrial site to provide bench-scale validation of performance in an industrial setting. Svante was developing and optimizing the post-combustion CO 2 adsorption technology architectures, including the Bi-layer and segmented laminated adsorbent structure design, integrated rapid cycle temperature swing adsorption (RC-TSA) cycle, flow path architecture, and adsorbent bed construction and packaging (including gas porting) to progress towards achievement of DOE’s Transformational CO 2 Capture goals of 95% CO 2 purity and a cost of electricity at least 30% lower than a supercritical Pulverized Coal (PC) power plant with CO 2 capture, or approximately $30 per tonne of CO 2 captured ready for demonstration by 2030. The main requirements to reach the DOE target cost of carbon capture below $30/MT using Rapid-Cycling Temperature Swing Adsorption (RC-TSA) are as follows: (1) Increased capacity at different CO 2 concentrations, (2) Increased sorbents cycle life, (3) Increased O 2 resistance, and (4) Decreased steam requirement to extract 1 kg of CO 2 .

20 FOSSIL-FUELED POWER PLANTS↗

Stability enhancement module for grid-following converters: Hardware implementation and validation

Low-frequency oscillations limit power delivery of voltage-source converter interfaced resources, for example, wind and solar, operating in grid-following control mode. Our prior research identified the instability mechanism as the coupling between real power and voltage at point of common coupling. In turn, a stability enhancement control was proposed to weaken the coupling by introducing a simple voltage-based feedback loop. The stability enhancement control has been validated via electromagnetic transient simulation testbeds. The objectives of this paper are (a) to provide a more insightful explanation of the enhancement module by examining the impedance of the grid-following converter and (b) to verify the performance of the stability module using a hardware testbed. The theoretic examination demonstrates that stability enhancement module effectively reduces the negative resistance effect of $Z_{qq}$ and thus boosts stability. The experimental research leads to a hardware testbed of a grid-following converter with the ability of demonstrating low-frequency oscillations. Finally, the experimental results demonstrate the efficacy of the proposed stability enhancement control and the readiness of commercial realization of the stability enhancement unit.

42 ENGINEERING↗