Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vapor cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Operating SIRTF for maximum lifetime

The instruments of the Space Infrared Telescope Facility (SIRTF) are cooled directly by liquid helium, while the optical system is cooled by helium vapor. The greater the power dissipation into the liquid helium, the more vapor is produced, and the colder the telescope. Observations at shorter wavelengths do not require telescope temperatures as low as those required at longer wavelengths. By taking advantage of this, it may be possible to extend the helium and mission lifetime by 10% or even 20%.

cryogenics↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

Avoiding pitfalls in molecular simulation of vapor sorption: Example of propane and isobutane in metal–organic frameworks for adsorption cooling applications

This study introduces recommendations for conducting molecular simulations of vapor adsorption, with an emphasis on enhancing the accuracy, reproducibility, and comparability of results. The first aspect we address is consistency in the implementation of some details of typical molecular models, including tail corrections and cutoff distances, due to their significant influence on generated data. We highlight the importance of explicitly calculating the saturation pressures at relevant temperatures using methods such as Gibbs ensemble Monte Carlo simulations and illustrate some pitfalls in extrapolating saturation pressures using this method. For grand canonical Monte Carlo (GCMC) simulations, the input fugacity is usually calculated using an equation of state, which often requires the critical parameters of the fluid. We show the importance of using critical parameters derived from the simulation with the same model to ensure internal consistency between the simulated explicit adsorbate phase and the implicit bulk phase in GCMC. We show the advantages of presenting isotherms on a relative pressure scale to facilitate easier comparison among models and with experiment. Extending these guidelines to a practical case study, we evaluate the performance of various isoreticular metal–organic frameworks (MOFs) in adsorption cooling applications. This includes examining the advantages of using propane and isobutane as working fluids and identifying MOFs with a superior performance.

36 MATERIALS SCIENCE↗

Oxidation behaviors of matrix-grade graphite during water vapor ingress accidents for high temperature gas-cooled reactors

Water ingress into cores of high temperature gas-cooled reactors (HTGRs) can cause serious safety problems in graphitic components, especially for matrix graphite, which is more vulnerable than nuclear graphite. Here in this study, oxidation behaviors of a matrix-grade graphite, ARB-B1, were investigated under simulated water ingress accidental conditions. The oxidation tests were conducted in water vapor/helium mixed atmospheres at elevated temperatures up to 1200 °C. Oxidation rates and activation energy were evaluated by mass loss measurements. The activation energy was 121.5 kJ/mol in the considered temperature range, indicating only one oxidation regime-in-pore diffusion assisted by cracks. The cracks originated from the fabrication process, acting as penetration paths for the oxidant, played an important role in the oxidation behaviors. Ungraphitized binder oxidation occurred at all temperatures, while apparent oxidation of filler particles started from 1100 °C. Moreover, oxidation effects on compressive properties and hardness of the matrix graphite were discussed in terms of oxidized microstructures. This first detailed study on matrix graphite oxidation in water vapor provides important kinetics knowledge and microstructural and mechanical data for accidental scenarios of HTGRs as well as for development of new matrix graphite materials.

36 MATERIALS SCIENCE↗

Method for condensing a CO2 vapor stream beyond the frost point

A method for cryogenic cooling without fouling is disclosed. The method comprises providing a first cryogenic liquid saturated with a dissolved gas; expanding the first cryogenic liquid into a separation vessel, separating into a vapor, a second cryogenic liquid, and a first solid; drawing the vapor into a heat exchanger and the second cryogenic liquid and the first solid out of the separation vessel; cooling the vapor against a coolant through the heat exchanger, causing the vapor to form a third cryogenic liquid and a second solid, the second solid dissolving in the third cryogenic liquid; and combining the second cryogenic liquid and the first solid with the third cryogenic liquid, producing a final cooled slurry. In this manner, the cryogenic cooling is accomplished without fouling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Vapor phase pyrolysis

The vapor phase pyrolysis process is designed exclusively for the lunar production of oxygen. In this concept, granulated raw material (soil) that consists almost entirely of metal oxides is vaporized and the vapor is raised to a temperature where it dissociates into suboxides and free oxygen. Rapid cooling of the dissociated vapor to a discrete temperature causes condensation of the suboxides, while the oxygen remains essentially intact and can be collected downstream. The gas flow path and flow rate are maintained at an optimum level by control of the pressure differential between the vaporization region and the oxygen collection system with the aid of the environmental vacuum.

Steurer, Wolfgang↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A cryogenically cooled photofragment fluorescence instrument for measuring stratospheric water vapor

An instrument developed for high-resolution daytime measurements of water vapor in the stratosphere using the technique of photofragment fluorescence is examined. A detailed description of all aspects of the instrument, as well as the results of its first two flights, are presented. The main areas of concern were optical baffling, cryogen transfer, water vapor measurement without contamination, and a dual path absorption measurement. Results of the second flight test indicate that the problems of instrument and gondola contamination, identified in the first flight test, were solved. A signal-to-noise ratio of about 50:1 for 10 sec of averaging throughout the stratosphere is achieved, as well as an altitude resolution of better than 100 m.

Weinstock, Elliot M.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

A Preliminary Study of the Preparation of Slurry Fuels from Vaporized Magnesium

Slurry fuels containing extremely small particles of magnesium were prepared by concentrating the dilute slurry product resulting from the shock-cooling of magnesium metal vapors with a liquid hydrocarbon spray. A complete description of the equipment and procedure used in preparing the fuel is given. Ninety-five percent by weight of the solid particles formed by this process passed through a 100-mesh screen. The particle-size distribution of the screened fraction of one run, as determined by sedimentation analysis, indicated that 73 percent by weight of the metal particles were finer than 2 microns in equivalent spherical diameter. The purity of the solid particles ranged as high as 98.9 percent by weight of free magnesium. The screened product was concentrated by means of a bowl-type centrifuge from 0.5 to more than 50 percent by weight solids content to form an extremely viscous, clay-like mass. By addition of a surface active agent, this viscous material was converted into a pumpable slurry fuel.

FUELS, PREPARATION↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

On-Orbit and Ground Performance of the PGBA Plant Growth Facility

PGBA, a plant growth facility developed for commercial space biotechnology research, successfully grew a total of 30 plants (6 species) for 10 days on board the Space Shuttle Endeavour (STS-77) and is scheduled for reflight on board MSL-1 (STS-83) for a 16 day flight. The PGBA life support systems provide atmospheric, thermal, and humidity control as well as lighting and nutrient supply in a 23.6 liter chamber. Atmosphere treatment includes ethylene and other hydrocarbon removal, CO2 replenishment, and O2 control. The normally closed system uses controlled CO2 replenishment from the crew cabin as required by the plants. Temperature is controlled (1 C) at user-specified setpoints between 20-32 C, using water-filled coolant loops, solid state Peltier thermoelectric devices, and liquid heat exchangers. The thermoelectric cooling systems were optimized for low power consumption and high cooling efficiencies. Relative humidity is maintained between 60-100% using a cooled porous metal plate to remove water vapor from the air stream without cooling the bulk air below the dew point. The lighting system utilizes three compact fluorescent bi-axial lights with variable lighting control and light intensity (PAR) between 220 and 330 micromol/sq m/s at a distance of 20 cm in spaceflight configuration (on orbit power limited to 230 Watt for entire payload). A ground, up to 550 micromol/sq m/s light intensity can be achieved with 330 Watt payload power consumption. Plant water and nutrient support is sustained via the 'Nutrient Pack' system including the passive or active 'Water Replenishable Nutrient Pack.' The root matrix material (soil or Agar) and nutrient formulation of each pack is prepared according to plant species and experimental requirements. These systems were designed by NASA Ames personnel. Data acquisition and control systems provide 32 channels of environmental data as well as digitized or analog video signals for downlink.

Hoehn, A.↗

Crystalline Silicates in Comets: Modeling Irregularly-Shaped Forsterite Crystals and Its Implications on Condensation Conditions

Crystalline silicates in comets are a product of the condensation in the hot inner regions (T > or approx. equals 1400 K [1]) of our proto-planetary disk or annealing at somewhat lower temperatures (T > or approx. equals 1000-1200 K) [2, 3, 4] in shocks coupled with disk evolutionary processes that include radial transport of crystals from their formation locations out to the cold outer regions where comet nuclei formed. The grain shape of forsterite (crystals) could be indicative of their formation pathways at high temperatures through vapor-solid condensation or at lower temperatures through vapor-liquid-solid formation and growth [5, 6, 7]. Experiments demonstrate that crystals that formed from a rapidly cooled highly supersaturated silicate vapor are characterized by bulky, platy, columnar/needle and droplet shapes for values of temperature and supersaturation, T and sigma, of 1000-1450 C and < 97, 700-1000 C and 97-161, 580-820 C and 131-230, and <500 C and > 230, respectively [7]. The experimental columnar/needle shapes, which form by vapor-liquid-solid at lower temperatures (<820 C), are extended stacks of plates, where the extension is not correlated with an axial direction: columnar/needles may be extended in the c-axis or a-axis direction, can change directions, and/or are off-kilter or a bit askew extending in a combination of the a- and c-axis direction.

Wooden, Diane H.↗

Colossal barocaloric effects with ultralow hysteresis in two-dimensional metal–halide perovskites

Pressure-induced thermal changes in solids—barocaloric effects—can be used to drive cooling cycles that offer a promising alternative to traditional vapor-compression technologies. Efficient barocaloric cooling requires materials that undergo reversible phase transitions with large entropy changes, high sensitivity to hydrostatic pressure, and minimal hysteresis, the combination of which has been challenging to achieve in existing barocaloric materials. Here, we report a new mechanism for achieving colossal barocaloric effects that leverages the large volume and conformational entropy changes of hydrocarbon order–disorder transitions within the organic bilayers of select two-dimensional metal–halide perovskites. Significantly, we show how the confined nature of these order–disorder phase transitions and the synthetic tunability of layered perovskites can be leveraged to reduce phase transition hysteresis through careful control over the inorganic–organic interface. The combination of ultralow hysteresis and high pressure sensitivity leads to colossal reversible isothermal entropy changes (>200 J kg -1 K -1 ) at record-low pressures (<300 bar).

36 MATERIALS SCIENCE↗

Climates of Warm Earth-Like Planets. I. 3D Model Simulations

We present a large ensemble of simulations of an Earth-like world with increasing insolation and rotation rate. Unlike previous work utilizing idealized aquaplanet congurations we focus our simulations on modern Earth-like topography. The orbital period is the same as modern Earth, but with zero obliquity and eccentricity. The atmosphere is 1 bar N2-dominated with CO2=400 ppmv and CH4=1 ppmv. The simulations include two types of oceans; one without ocean heat transport (OHT) between grid cells as has been commonly used in the exoplanet literature, while the other is a fully coupled dynamic bathtub type ocean. The dynamical regime transitions that occur as day length increases induce climate feedbacks producing cooler temperatures, rst via the reduction of water vapor with increasing rotation period despite decreasing shortwave cooling by clouds, and then via decreasing water vapor and increasing shortwave cloud cooling, except at the highest insolations. Simulations without OHT are more sensitive to insolation changes for fast rotations while slower rotations are relatively insensitive to ocean choice. OHT runs with faster rotations tend to be similar with gyres transporting heat poleward making them warmer than those without OHT. For slower rotations OHT is directed equator-ward and no high latitude gyres are apparent. Uncertainties in cloud parameterization preclude a precise determination of habitability but do not a affect robust aspects of exoplanet climate sensitivity. This is the first paper in a series that will investigate aspects of habitability in the simulations presented herein. The datasets from this study are open source and publicly available.

Planetary systems↗

Review of Vapor Compression Refrigeration in Microgravity Environments

Using a vapor compression cycle for cooling in microgravity environments was already suggested in the 1970s to leverage the high coefficient of performance. Since then, only a few systems have operated in microgravity with scarce documentation of these flights. The lack of measured data and detailed documentation makes identifying the necessary next steps difficult for researchers entering the field of refrigeration in space. This paper provides a review of available literature for vapor compression systems flown in microgravity by outlining the history of vapor compression devices in space and presenting performance data. Moreover, gaps in the literature are highlighted and open questions are posed based on the reviewed material. Next steps of research are suggested to support and ultimately achieve reliable vapor compression refrigeration in space. Calculating equivalent masses for a fair comparison of different microgravity cooling technologies is proposed by capturing both energy consumption and used volume.

Vapor compression↗

Modeling Two-Phase Flow and Vapor Cycles Using the Generalized Fluid System Simulation Program

This work presents three new applications for the general purpose fluid network solver code GFSSP developed at NASA's Marshall Space Flight Center: (1) cooling tower, (2) vapor-compression refrigeration system, and (3) vapor-expansion power generation system. These systems are widely used across engineering disciplines in a variety of energy systems, and these models expand the capabilities and the use of GFSSP to include fluids and features that are not part of its present set of provided examples. GFSSP provides pressure, temperature, and species concentrations at designated locations, or nodes, within a fluid network based on a finite volume formulation of thermodynamics and conservation laws. This paper describes the theoretical basis for the construction of the models, their implementation in the current GFSSP modeling system, and a brief evaluation of the usefulness of the model results, as well as their applicability toward a broader spectrum of analytical problems in both university teaching and engineering research.

Smith, Amanda D.↗