Approaching hydro-equivalent ignition in laser direct-drive via target design optimization using novel statistical modeling

Laser direct-drive offers significant advantages in terms of target simplicity, improved energy coupling, and large fuel masses over indirect drive. However, performance degradations from hydrodynamic and laser-plasma instabilities seeded and driven by the direct illumination pose limitations on the parameter space available for achieving ignition. In this paper, new design improvements are identified to forge a path forward for a hydro-equivalent ignition demonstration. The first is related to a new formulation of the statistical model (SM) used to accurately predict target performance directly from input parameters such as laser pulse shape and target specifications. This new SM formulation provides direct guidance on target dimensions and laser beam-to-target radius to achieve the highest fusion yield on the OMEGA laser. The second improvement comes from cooling the deuterium–tritium (DT) ice layer below the triple point right before shot time leading to lower DT vapor densities and higher convergence. Guided by these design improvements, a Bayesian optimization algorithm was used to design an implosion that is predicted to closely approach a Lawson triple product that hydrodynamically scales to ignition if equivalent laser–target coupling is achieved at laser energies typical of the National Ignition Facility.

Deuterium↗

Numerical Investigation of Fuel Property Effects on Mixed-Mode Combustion in a Spark-Ignition Engine

In this research, lean mixed-mode combustion is numerically investigated using computational fluid dynamics (CFD) in a spark-ignition engine. A new E30 fuel surrogate is developed using a neural network model with matched octane numbers. A skeletal mechanism is also developed by automated mechanism reduction and by incorporating a NO x submechanism. A hybrid approach that couples the G-equation model and the well-stirred reactor model is employed for turbulent combustion modeling. The developed CFD model is shown to well predict pressure and apparent heat release rate (AHRR) traces compared with experiment. Two types of combustion cycles (deflagration-only and mixed-mode cycles) are observed. The mixed-mode cycles feature early flame propagation and subsequent end-gas auto-ignition, leading to two distinctive AHRR peaks. The validated CFD model is then employed to investigate the effects of NO x chemistry. The NO x chemistry is found to promote auto-ignition through the residual gas, while the deflagration phase remains largely unaffected. Sensitivity analysis is finally performed to understand effects of fuel properties, including heat of vaporization (HoV) and laminar flame speed (S L ). An increased HoV tends to suppress auto-ignition through charge cooling, while the impact of HoV on flame propagation is insignificant. In contrast, an increased S L is found to significantly promote both flame propagation and end-gas auto-ignition. The promoting effect of S L on auto-ignition is not a direct chemical effect; it is rather caused by an advancement of the combustion phasing, which increases compression heating of the end-gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

A remarkable CHF of 345W/cm 2 is achieved in a wicked-microchannel using HFE-7100

Boiling heat transfer of dielectric fluids is a promising cooling technique for thermal management of microelectronic systems. However, the critical heat flux achievable is generally low, because of the poor thermophysical properties of these fluids. Here, to address this dilemma, we propose a new cooling concept to substantially enhance global liquid supply during phase-change process using enhanced capillary-driven force. Additionally, dedicated vapor pathways are designed among a bank of micro-pillars to facilitate vapor removal. In this work, new wicks comprised of silicon micro-pinfin arrays are explored to significantly enhance the flow boiling heat transfer performance. To examine the functionalities of this wick, experiments on HFE-7100 were carried out with mass velocities varying from 247 to 3,465 kg/m 2 s. To explore the enhancement mechanisms and to analyze the capillary-assisted flow boiling process, visualization studies were conducted. The results indicate that sustainable evaporation induced by wick microstructures and efficient liquid supply are the enhancement mechanisms compared to parallel microchannels with solid walls. It is found that the overall heat transfer coefficient is substantially increased up to 75%. Remarkably, a high critical heat flux (CHF) of approximately 345 W/cm 2 is recorded at G = 3,465 kg/m 2 s at coolant inlet temperature of ~20 °C. Equally importantly, this noticeable enhancement of CHF value is associated with drastically decreased pressure drops compared to microchannels decorated with μ-pinfin fences.

36 MATERIALS SCIENCE↗

Predicted Heat Flux Performance of Actively Cooled Tungsten-Armored Graphitic Foam Monoblocks

Tungsten (W)–armored graphitic foam monoblocks were developed for applications requiring high-Z plasma-facing material in long-pulse fusion experiments and ultimately deuterium-tritium fusion reactors. The monoblocks are an integrated material system combining the advantages of a chemical vapor deposited (CVD) W coating with a high-conductivity graphitic foam. The W is a high-melting-point, high-Z material with low tritium retention. The graphitic foam coupled to a swirl tube serves as a high-thermal-conductivity heat sink that cannot melt, although it can sublime at much higher temperatures than copper melts. Together, they comprise a robust plasma-facing component (PFC) weighing roughly 5% of an all-W component or 17% of a traditional W-coated copper heat sink.A single-channel mock-up consisting of four graphitic foam monoblocks equipped with a water-cooled swirl tube was fabricated for eventual testing in the 60-kW, EB-60, rastered electron beam at the Applied Research Laboratory of The Pennsylvania State University. Two monoblocks have a thin 50-μm-thick coating of pure W chemically vapor deposited over NbC and pure Nb interlayers. Two others have a 2-mm-thick pure W coating CVD on graphitic monoblocks using the same interlayers. The mock-up will be cooled with available 10 m/s, 0.7 MPa water with a 22°C inlet temperature and subjected to varying uniform heat loads up to 20 MW/m 2 . It is equipped with type-K thermocouples at various depths, and calibrated infrared thermography and spot pyrometry will be used to characterize the heated surface. Real-time water calorimetry will be used to ascertain the absorbed steady-state power and infer the heat flux during testing. Since testing cannot be done under prototypic divertor flow conditions, it is necessary to predict the thermal response of this novel PFC system and investigate the power sharing between radiation and convection at divertor heat flux levels and its inherent ability to avoid critical heat flux. Results are reported for predictions obtained from computational fluid dynamics models up to 30 MW/m 2 of steady-state uniform heat flux. Leading-edge heat loads of 30 MW/m 2 on a 2-mm-wide side strip were also investigated to ascertain if coating delamination is likely.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme Water Uptake of Hygroscopic Hydrogels through Maximized Swelling‐Induced Salt Loading

Abstract Hygroscopic hydrogels are emerging as scalable and low‐cost sorbents for atmospheric water harvesting, dehumidification, passive cooling, and thermal energy storage. However, devices using these materials still exhibit insufficient performance, partly due to the limited water vapor uptake of the hydrogels. Here, the swelling dynamics of hydrogels in aqueous lithiumchloride solutions, the implications on hydrogel salt loading, and the resulting vapor uptake of the synthesized hydrogel–salt composites are characterized. By tuning the salt concentration of the swelling solutions and the cross‐linking properties of the gels, hygroscopic hydrogels with extremely high salt loadings are synthesized, which enable unprecedented water uptakes of 1.79 and 3.86 gg −1 at relative humidity (RH) of 30% and 70%, respectively. At 30% RH, this exceeds previously reported water uptakes of metal–organic frameworks by over 100% and of hydrogels by 15%, bringing the uptake within 93% of the fundamental limit of hygroscopic salts while avoiding leakage problems common in salt solutions. By modeling the salt‐vapor equilibria, the maximum leakage‐free RH is elucidated as a function of hydrogel uptake and swelling ratio. These insights guide the design of hydrogels with exceptional hygroscopicity that enable sorption‐based devices to tackle water scarcity and the global energy crisis.

Graeber, Gustav↗

Study of the heat pipe vapor flow using the MOOSE application Sockeye and the CFD code Nek5000

Heat pipes are efficient heat transfer devices used in various applications, including nuclear microreactors. Heat pipe-cooled microreactors offer advantages in size and cost, which can significantly accelerate their deployment and adoption. Developing accurate models of heat pipes is crucial for a heat pipe-cooled microreactor design and operation. In this work a verification and validation of the heat pipe application Sockeye is presented. Results are compared against RANS simulations, performed with the code Nek5000, and the SPHERE experiment, conducted at INL.

42 ENGINEERING↗

Functionalized carbon nanotubes for thermionic emission and cooling applications

Barium strontium oxide-coated carbon nanotubes (CNTs) were implemented as a work function lowering and field enhancing functional coating on a coiled tungsten filament to create a new thermionic cathode. This cathode resembles conventional oxide cathodes in structure. It has the same coiled tungsten filament as a conventional oxide cathode but uses barium strontium oxide-coated CNTs instead of the traditional barium strontium calcium oxide powder mixture as an emissive coating. The cathode produces a strong thermionic emission. At 1395 K and 2.5 V/μm, the thermionic emission current of 0.87 A or current density of 2.9 A/cm 2 was obtained from this oxide-coated CNT cathode. This level of emission is about three times as large as a conventional oxide cathode operating at similar temperature and field strength. Strong thermionic emissions from the cathode also lead to a large thermionic cooling effect. Temperature reduction as large as 90° was observed from the cathode surface when it was emitting electrons. Strong thermionic emission and a large cooling effect obtained are the result of the combination of the low work function of barium strontium oxide (1.6 eV) and the large field effect induced by the CNTs. Plasma enhanced chemical vapor deposition was used to grow CNTs, and magnetron sputtering deposition was used to deposit the barium strontium oxide functional coating; details of the cathode fabrication are presented to illustrate both the versatility of the processing techniques and the adaptability of barium strontium oxide-coated CNTs as a functional coating. Finally, measurements on thermionic emission and thermionic cooling of the cathode are also presented.

36 MATERIALS SCIENCE↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves the resistance measurement of a thin film of niobium. During coating, the change in resistance reflects the conversion of the film to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the thickness, allowing for increased precision in future depositions.

Howard, K. [Unlisted] (ORCID:0000000325613308)↗

Development of in situ thickness sensor for vapor diffused Nb3Sn films

Fermilab is one of the leaders in development of vapor diffused Nb3Sn films inside niobium cavities. This material has a higher critical temperature (Tc) than niobium, enabling cavity operation at 4.2 K. This higher operational temperature significantly reduces the infrastructure required for cooling compared to 2 K systems, making superconducting radio-frequency (SRF) technology more accessible. Current deposition methods have relied on iterative testing to determine nominal film thickness, a process that can be time-consuming and imprecise. To address this, we are developing a sensor to measure the thickness of Nb3Sn thin film in situ during vapor diffusion. Our design involves a four-point resistance measurement of a thin film of niobium, inside the coating region. During coating, the change in resistance reflects the conversion of the film from Nb to Nb3Sn, which allows simple integration with the current furnace infrastructure. This sensor would allow real time measurement of the Nb3Sn film thickness, allowing for increased precision in future depositions for cavity applications.

Howard, K. [Chicago U.] (ORCID:0000000325613308)↗

Adsorption system

An adsorption system can be used as part of a climate control system in a vehicle or in any other space requiring heating or cooling. The adsorbent system can include an enclosure, a plurality of layers arranged in a stack inside the enclosure, and a vapor channel inside the enclosure.

Wang, Evelyn N.↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Liquid desiccant based dehumidification and cooling system

A liquid desiccant system including a high desorber, a low desorber, and an absorber that are in fluid communication with a working solution, where the high desorber provides rejected water vapor from the working fluid for condensation in a condenser of the low desorber that provides heat for rejection of additional water from the working solution in the low desorber effectively multiplying the heat provided for desorption. The low desorber provided the concentrated working solution to the absorber where water from ambient air is condensed into the concentrated working solution to provide a dilute working solution within a working solution conduit of the absorber that is thermally coupled to an internal cooler of the absorber. In some embodiments, the working solution can be an aqueous solution of at least one ionic liquid.

Moghaddam, Saeed↗

Liquid desiccant based dehumidification and cooling system

A liquid desiccant system including a high desorber, a low desorber, and an absorber that are in fluid communication with a working solution, where the high desorber provides rejected water vapor from the working fluid for condensation in a condenser of the low desorber that provides heat for rejection of additional water from the working solution in the low desorber effectively multiplying the heat provided for desorption. The low desorber provided the concentrated working solution to the absorber where water from ambient air is condensed into the concentrated working solution to provide a dilute working solution within a working solution conduit of the absorber that is thermally coupled to an internal cooler of the absorber. In some embodiments, the working solution can be an aqueous solution of at least one ionic liquid.

Moghaddam, Saeed↗

Boundary layer moisture variability at the Atmospheric Radiation Measurement (ARM) Eastern North Atlantic observatory during marine conditions

Abstract. Boundary layer moisture variability at the Eastern North Atlantic (ENA) site during marine conditions is examined at monthly and daily timescales using 5 years of ground-based observations and output from the European Center for Medium range Weather Forecast (ECMWF) reanalysis model. The annual cycle of the mixed-layer total water budgets is presented to estimate the relative contribution of large-scale advection, local moisture tendency, entrainment, and precipitation to balance the moistening due to surface latent heat flux on monthly timescales. When marine conditions prevail, advection of colder and dry air from the north acts as an important moisture sink (∼ 50 % of the overall budget) during fall and winter driving the seasonality of the budget. Entrainment and precipitation contribute to the drying of the boundary layer (∼ 25 % and ∼ 15 % respectively), and the local change in moisture contributes to a small residual part. On a daily temporal scale, moist and dry mesoscale columns of vapor (∼ 10 km) are analyzed during 10 selected days of precipitating stratocumulus clouds. Adjacent moist and dry columns present distinct mesoscale features that are strongly correlated with clouds and precipitation. Dry columns adjacent to moist columns have more frequent and stronger downdrafts immediately below the cloud base. Moist columns have more frequent updrafts, stronger cloud-top cooling, and higher liquid water path and precipitation compared to the dry columns. This study highlights the complex interaction between large-scale and local processes controlling the boundary layer moisture and the importance of spatial distribution of vapor to support convection and precipitation.

54 ENVIRONMENTAL SCIENCES↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

pyTCR: A tropical cyclone rainfall model for python

pyTCR is a climatology software package developed in the Python programming language. It integrates the capabilities of several legacy physical models and increases computational efficiency to allow rapid estimation of tropical cyclone (TC) rainfall consistent with the large-scale environment. Specifically, pyTCR implements a horizontally distributed and vertically integrated model [Zhu et al., 2013] for simulating rainfall driven by TCs. Along storm tracks, rainfall is estimated by computing the cross-boundary-layer, upward water vapor transport caused by different mechanisms including frictional convergence, vortex stretching, large-scale baroclinic effect (i.e., wind shear), topographic forcing, and radiative cooling [Lu et al., 2018]. The package provides essential functionalities for modeling and interpreting spatio-temporal TC rainfall data. pyTCR requires a limited number of model input parameters, making it a convenient and useful tool for analyzing rainfall mechanisms driven by TCs. To sample rare (most intense) rainfall events that are often of great societal interest, pyTCR adapts and leverages outputs from a statistical-dynamical TC downscaling model [Lin et al., 2023] capable of rapidly generating a large number of synthetic TCs given a certain climate. As a result, pyTCR significantly reduces computational effort and improves the efficiency in capturing extreme TC rainfall events at the tail of the distributions from limited datasets. Furthermore, the TC downscaling model is forced entirely by large-scale environmental conditions from reanalysis data or coupled General Circulation Models (GCMs), simplifying the projection of TC-induced rainfall and wind speed under future climate using pyTCR. Finally, pyTCR can be coupled with hydrological and wind models to assess risks associated with independent and compound events (e.g., storm surges and freshwater flooding).