Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variational”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Active-Space N -Representability Constraints for Variational Two-Particle Reduced Density Matrix Calculations

The ground-state energy of a system of fermions can be calculated by minimizing a linear functional of the two-particle reduced density matrix (2-RDM) if an accurate set of N-representability conditions is applied. In this Letter we introduce a class of linear N-representability conditions based on exact calculations on a reduced active space. Unlike wave-function-based approaches, the 2-RDM methodology allows us to combine information from calculations on different active spaces. By adding active-space constraints, we can iteratively improve our estimate for the ground-state energy. Applying our methodology to a 1D Hubbard model yields a significant improvement over traditional 2-positivity constraints with the same computational scaling.

74 ATOMIC AND MOLECULAR PHYSICS↗

Variational Monte Carlo Calculations of A ≤ 4 Nuclei with an Artificial Neural-Network Correlator Ansatz

Here, the complexity of many-body quantum wave functions is a central aspect of several fields of physics and chemistry where nonperturbative interactions are prominent. Artificial neural networks (ANNs) have proven to be a flexible tool to approximate quantum many-body states in condensed matter and chemistry problems. In this work we introduce a neural-network quantum state ansatz to model the ground-state wave function of light nuclei, and approximately solve the nuclear many-body Schrodinger equation. Using efficient stochastic sampling and optimization schemes, our approach extends pioneering applications of ANNs in the field, which present exponentially scaling algorithmic complexity. We compute the binding energies and point-nucleon densities of A ≤ 4 nuclei as emerging from a leading-order pionless effective field theory Hamiltonian. We successfully benchmark the ANN wave function against more conventional parametrizations based on two- and three-body Jastrow functions, and virtually exact Green's function Monte Carlo results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DFF Layout Variations in CMOS SOI—Analysis of Hardening by Design Options

Four D flip-flop (DFF) layouts were created from the same schematic in Sandia National Laboratories’ CMOS7 silicon-on-insulator (SOI) process. Single-event upset (SEU) modeling and testing showed an improved response with the use of shallow (not fully bottomed) N-type metal-oxide-semiconductor field-effect transistors (NMOSFETs), extending the size of the drain implant and increasing the critical charge of the transmission gates in the circuit design and layout. This research also shows the importance of correctly modeling nodal capacitance, which is a major factor determining SEU critical charge. Accurate SEU models enable the understanding of the SEU vulnerabilities and how to make the design more robust.

42 ENGINEERING↗

Long-time variation in magnetic structure of Ce(Ir x Rh 1– x ) 3 Si 2 : A new interpretation of time variation

Here, to clarify the key factor for the slow magnetic transitions in CeIr 3 Si 2 and other materials, magnetization and neutron scattering measurements have been carried out on the system Ce(Ir x Rh 1–x ) 3 Si 2 . In this system, a magnetic phase transition is accomplished through slow and fast processes. The fractions of these processes vary with the chemical composition x . A new interpretation of magnetic phase transitions, which includes the coexistence of two processes, is presented.

36 MATERIALS SCIENCE↗

Influence of glucocorticoids on time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor-mediated systemic anaphylaxis in different mouse strains

Highlights: • Daily variations in systemic anaphylaxis differed among inbred mouse strains. • The daily variations differed with anaphylaxis-inducing substances. • Glucocorticoid-dependent and -independent mechanisms regulated the variations. A time-of-day-dependent variation in IgE-mediated passive systemic anaphylaxis was previously reported in ICR mice. In the present study, we investigated time-of-day-dependent variations in IgE-, histamine-, and platelet-activating factor (PAF)-mediated systemic anaphylaxis in C57BL/6, BALB/c, and NC/Nga mice at 9:00 h and 21:00 h, and evaluated the potential influence of glucocorticoids (GCs) on these variations. We found significant time-of-day-dependent variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice, and in histamine- and PAF-mediated systemic anaphylaxis in BALB/c mice. Significant daily variations in IgE-, histamine-, and PAF-mediated systemic anaphylaxis were not observed in NC/Nga mice. Pretreatment with dexamethasone and adrenalectomy abolished the daily variations in IgE-mediated systemic anaphylaxis in C57BL/6 mice and in PAF-mediated systemic anaphylaxis in BALB/c mice, suggesting that GCs from adrenal glands are pivotal in regulating these variations. In contrast, pretreatment with dexamethasone and adrenalectomy did not abolish the daily variation in histamine-mediated systemic anaphylaxis in BALB/c mice, suggesting that GC-independent and adrenal gland-independent mechanisms are important for the variation. The present study demonstrated that time-of-day-dependent variations in systemic anaphylaxis differed among inbred mouse strains and with anaphylaxis-inducing substances. Thus, mouse strains, time of experiment, and anaphylaxis-inducing substances used must be considered to obtain appropriate experimental results.

60 APPLIED LIFE SCIENCES↗

DISSECTING THE RED SEQUENCE. III. MASS-TO-LIGHT VARIATIONS IN THREE-DIMENSIONAL FUNDAMENTAL PLANE SPACE

The fundamental plane (FP) of early-type galaxies is observed to have finite thickness and to be tilted from the virial relation. Both of these represent departures from the simple assumption that dynamical mass-to-light ratios (M{sub dyn}/L) are constant for all early-type galaxies. We use a sample of 16,000 quiescent galaxies from the Sloan Digital Sky Survey to map out the variations in M {sub dyn}/L throughout the three-dimensional FP space defined by velocity dispersion ({sigma}), effective radius (R{sub e}), and effective surface brightness (I{sub e}). Dividing M{sub dyn}/L into multiple components allows us to separately consider the contribution to the observed M{sub dyn}/L variation due to stellar population effects, initial mass function (IMF) variations, and variations in the dark matter fraction within one R{sub e} . Along the FP, we find that the stellar population contribution given some constant IMF (M{sub *,IMF}/L) scales with {sigma} such that M{sub *,IMF}/L {proportional_to} f({sigma}). Meanwhile, the dark matter and/or IMF contribution (M{sub dyn}/M {sub *,IMF}) scales with M{sub dyn} such that M{sub dyn}/M {sub *,IMF} {proportional_to} g(M{sub dyn}). This means that the two contributions to the tilt of the FP rotate the plane around different axes in the three-dimensional space. The observed tilt of the FP requires contributions from both, with dark matter/IMF variations likely comprising the dominant contribution. Looking at M {sub dyn}/L variations through the thickness of the FP, we find that M{sub dyn}/L variations must be dominated either by IMF variations or by real differences in the dark matter fraction with R{sub e} . This means that the finite thickness of the FP is due to variations in the stellar mass surface density within R{sub e} ({Sigma}{sub *,IMF}), not the fading of passive stellar populations. It therefore represents genuine structural differences between early-type galaxies. These structural variations are correlated with galaxy star formation histories such that galaxies with higher M{sub dyn}/M {sub *,IMF} have higher [Mg/Fe], lower metallicities, and older mean stellar ages. We discuss several physical mechanisms that might explain the observed co-variation between M {sub dyn}/M {sub *,IMF} and galaxy star formation histories. It is difficult to explain the observed enhancement of {alpha}-elements in lower-surface-brightness galaxies by allowing the IMF to vary. Differences in dark matter fraction can be produced by variations in the 'conversion efficiency' of baryons into stars or by the redistribution of stars and dark matter through dissipational merging. The former explanation, specifically a model in which some galaxies experience low conversion efficiencies due to premature truncation of star formation, provides a more natural explanation for the co-variation of M{sub dyn}/M {sub *,IMF} and the observed stellar population properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Model and Standard Operating Procedures Supporting Signal Variation Flow Graph Analysis

This document will describe the principles of the Signal Variation Flow Technique, and the uncertainty models generated using it. We focus on the capture of the variation between the ideal signal and the measured signal. The ideal signal is defined to represent the signal output of a system whose full state behavior is known, with no variation in environment or during operation, and whose photons trajectories are not modified by the object. A CT uncertainty analysis is the result of two main steps. First, the radiography regime extends from the source to the collected image, which is 2D in the case of standard CT. This maps all upstream uncertainties into the variation observed on the radiograph and captures all variation in the physical domain. Second, the reconstruction regime extends from the captured images to the reconstructed 3D image. This regime is purely in the mathematical domain and corrects reconstruction algorithm artifacts/anomalies. The present work focuses on building the model through the radiography regime. The reconstruction regime is expected to be largely a study of algorithmic sensitivity, requiring the definition of a range of standardized tests through which the algorithms would be run. Radiographic variation would then be mapped through reconstruction sensitivities to predict the signal variation in the final image. An incomplete list for the reconstructed image variation output basis includes voxel density, edge blur and length variation, in analogous fashion to the basis functions presented in this work. The signal variation occurs in several forms at the radiograph. These forms are gathered into a complete basis set of functions describing all variation on the radiograph. The scale of each basis function is calculated independently via a specific SVFG. This includes 0D pixel noise (0DI), 0D energy noise (0DE), 1D blur (1DB), 1D length (1DL) or 2D position (2DP). These models are orthogonal in that they each explore a space in the signal variation domain that cannot be reached by the other basis functions. The variation basis functions, and associated SVFG models are split by output dimensionality, a term loosely used for categorization, and explained further below.

42 ENGINEERING↗

SU-E-T-408: Evaluation of the Type and Frequency of Variations Discovered During Routine Secondary Patient Chart Review

Purpose: Desire to improve efficiency and throughput inspired a review of our physics chart check procedures. Departmental policy mandates plan checks pre-treatment, after first treatment and weekly every 3–5 days. This study examined the effectiveness of the “after first” check with respect to improving patient safety and clinical efficiency. Type and frequency of variations discovered during this redundant secondary review was examined over seven months. Methods: A community spreadsheet was created to record variations in care discovered during chart review following the first fraction of treatment and before the second fraction (each plan reviewed prior to treatment). Entries were recorded from August 2014 through February 2015, amounting to 43 recorded variations out of 906 reviewed charts. The variations were divided into categories and frequencies were assessed month-to-month. Results: Analysis of recorded variations indicates an overall variation rate of 4.7%. The initial rate was 13.5%; months 2–7 average 3.7%. The majority of variations related to discrepancies in documentation at 46.5%, followed by prescription, plan deficiency, and dose tracking related variations at 25.5%, 12.8%, and 12.8%, respectively. Minor variations (negligible consequence on patient treatment) outweighed major variations 3 to 1. Conclusion: This work indicates that this redundant secondary check is effective. The first month spike in rates could be due to the Hawthorne/observer effect, but the consistent 4% variation rate suggests the need for periodical re-training on variations noted as frequent to improve awareness and quality of the initial chart review process, which may lead to improved treatment quality, patient safety and increased clinical efficiency. Utilizing these results, a continuous quality improvement process following Deming’s Plan-Do-Study-Act (PDSA) methodology was generated. The first iteration of this PDSA was adding a specific dose tracking checklist item in the pre-treatment plan check assessment; the ramification of which will be assessed in future data.

60 APPLIED LIFE SCIENCES↗

Poster - 33: Dosimetry Comparison of Prone Breast Forward and Inverse Treatment planning considering daily setup variations

Introduction: The purpose of this study is to investigate the effects of daily setup variations on prone breast forward field-in-field (FinF) and inverse IMRT treatment planning. Methods: Rando Phantom (Left breast) and Pixy phantom (Right breast) were built and CT scanned in prone position. The treatment planning (TP) is performed in Eclipse TP system. Forward FinF plan and inverse IMRT plan were created to satisfy the CTV coverage and OARs criteria. The daily setup variations were assumed to be 5 mm at left-right, superior-inferior, and anterior-posterior directions. The DVHs of CTV coverage and OARs were compared for both forward FinF plan and inverse IMRT plans due to 5mm setup variation. Results and Discussions: DVHs of CTV coverage had fewer variations for 5m setup variation for forward FinF and inverse IMRT plan for both phantoms. However, for the setup variations in the left-right direction, the DVH of CTV coverage of IMRT plan showed the worst variation due to lateral setup variation for both phantoms. For anterior-posterior variation, the CTV could not get full coverage when the breast chest wall is shallow; however, with the guidance of MV imaging, breast chest wall will be checked during the MV imaging setup. So the setup variations have more effects on inverse IMRT plan, compared to forward FinF plan, especially in the left-right direction. Conclusions: The Forward FinF plan was recommended clinically considering daily setup variation.

60 APPLIED LIFE SCIENCES↗

Dosimetric effects of rotational output variation and x-ray target degradation on helical tomotherapy plans

In this study, two potential sources of IMRT delivery error have been identified for helical tomotherapy delivery using the HiART system (TomoTherapy, Inc., Madison, WI): Rotational output variation and target degradation. The HiArt system is known to have output variation, typically about {+-}2%, due to the absence of a dose servo system. On the HiArt system, x-ray target replacement is required approximately every 10-12 months due to target degradation. Near the end of target life, the target thins and causes a decrease in the beam energy and a softening of the beam profile at the lateral edges of the beam. The purpose of this study is to evaluate the dosimetric effects of rotational output variation and target degradation by modeling their effects and incorporating them into recalculated treatment plans for three clinical scenarios: Head and neck, partial breast, and prostate. Models were created to emulate both potential sources of error. For output variation, a model was created using a sine function to match the amplitude ({+-}2%), frequency, and phase of the measured rotational output variation data. A second model with a hypothetical variation of {+-}7% was also created to represent the largest variation that could exist without violating the allowable dose window in the delivery system. A measured beam profile near the end of target life was used to create a modified beam profile model for the target degradation. These models were then incorporated into the treatment plan by modifying the leaf opening times in the delivery sinogram. A new beam model was also created to mimic the change in beam energy seen near the end of target life. The plans were then calculated using a research version of the PLANNED ADAPTIVE treatment planning software from TomoTherapy, Inc. Three plans were evaluated in this study: Head and neck, partial breast, and prostate. The D{sub 50} of organs at risk, the D{sub 95} for planning target volumes (PTVs), and the local dose difference were used to evaluate the changes in the modified treatment plans. Dosimetric effects from rotational variation were found to be low (less than 1%) for a typical variation of {+-}2%. Even using a variation of {+-}7%, DVH values and dose distributions were altered by less than 2% for all scenarios. The dosimetric effects of target degradation were found to be slightly more significant. For a model using data taken just before target failure, dosimetric differences of 2%-4% were observed in the recalculated plans when compared to the original plans. The largest effects (up to 4.5%) were observed for PTVs that were located at deeper depths as seen in the prostate plan. Overall, the recalculated plans show that the dosimetric effects of rotational variation and target degradation are on the order of 1%-4% for helical tomotherapy on the HiART system and do not pose a risk for significant deviations from the original treatment plan.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-decadal river flow variations in France

In this article, multi-decadal variations in the French hydroclimate are investigated, with a specific focus on river flows. Based on long observed series, it is shown that river flows in France generally exhibit large multi-decadal variations in the instrumental period (defined in this study as the period from the late 19th century to the present), especially in spring. Differences of means between 21 yr periods of the 20th century as large as 40% are indeed found for many gauging stations. Multi-decadal spring river flow variations are associated with variations in spring precipitation and temperature. These multi-decadal variations in precipitation are themselves found to be driven by large-scale atmospheric circulation, more precisely by a multi-decadal oscillation in a sea level pressure dipole between western Europe and the eastern Atlantic. It is suggested that the Atlantic Multidecadal Variability, the main mode of multi-decadal variability in the North Atlantic–Europe sector, controls those variations in large-scale circulation and is therefore the main ultimate driver of multi-decadal variations in spring river flows. Potential multi-decadal variations in river flows in other seasons, and in particular summer, are also noted. As they are not associated with significant surface climate anomalies (i.e. temperature, precipitation) in summer, other mechanisms are investigated based on hydrological simulations. The impact of climate variations in spring on summer soil moisture, and the impact of soil moisture in summer on the runoff-to-precipitation ratio, could potentially play a role in multi-decadal summer river flow variations. The large amplitude of the multi-decadal variations in French river flows suggests that internal variability may play a very important role in the evolution of river flows during the next decades, potentially temporarily limiting, reversing or seriously aggravating the long-term impacts of anthropogenic climate change.

54 ENVIRONMENTAL SCIENCES↗