Search NASA⌕ Search

SEARCH · Search NASA

Results for “Venous Pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

60 Days of Head-down Bedrest Differentially Alters Venous Function in Lower and Upper Body Between Healthy Men and Women

The incidence of orthostatic intolerance after space flight is disproportionally higher in female compared to male crewmembers (83% vs. 20%). Experimental and human data suggest that the loss of orthostatic tolerance is due, at least in part, to microgravity-induced changes in venous compliance and that these changes are specific to the lower body. It is unknown however, whether the changes in venous compliance are different between males and females after space flight, and whether this is related to the disparity in orthostatic intolerance between the sexes. Using 6deg head-down bed rest (BR) as a model of space flight, we tested the following hypotheses; 1) females, compared to males, would experience a greater increase in venous compliance in dorsal foot veins as an effect of BR and 2) no differences in venous compliance would be found in dorsal hand veins between sexes and across BR days. Using 2-D ultrasound, dorsal hand (DHV) and foot vein (DFV) responses (diameter; expressed as sq mm) to 40 mmHg of congestion pressure (compliance) and to intravenous infusion of phenylephrine (PE; 3160ng/min) were determined in 10 females and 16 males before and after 60 days of BR. The relation between changes in vein diameter (in response to pressure and PE), sex, limb, and BR days were determined using a mixed-effect linear regression. It was found that after 60 days of BR, DFV dilator response to pressure was significantly greater in females and significantly less in males compared to pre-BR. As expected, there were no differences in DHV dilator response between sexes nor was there a significant difference between pre and post measures within groups. Notably, the venoconstrictor response to infusions of PE in the DHV and DFV where similar between sexes and across BR days. In conclusion, this study demonstrates that after 60 days of BR, dorsal foot veins are more compliant in women and less compliant in men. Moreover, the changes in lower body vein compliance in females do not appear to be due to changes in vasoconstrictor tone as their response to PE was preserved and similar to that in males. Taken together these data suggest that the higher incidence of orthostatic intolerance in females after space flight is due to increased venous compliance in the lower body which could translate to lower venous filling pressures and a reduced stroke volume.

Westby, Christian M.↗

Effects of Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated medical condition consisting of a constellation of symptoms affecting less than 70% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures and is hypothesized to be related to elevated intracranial pressure secondary to spaceflight-induced cephalad fluid shifts, although other space flight factors (e.g., diet, environmental factors) may contribute. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years postflight.

Platts, S. H.↗

Effects of Spaceflight on Venous and Arterial Compliance

The visual impairment and intracranial pressure (VIIP) syndrome is a spaceflight-associated set of symptoms affecting more than 50% of American astronauts who have flown International Space Station (ISS) missions. VIIP is defined primarily by visual acuity deficits and anatomical changes to eye structures (e.g. optic disc edema, choroidal folds, and globe flattening) and is hypothesized to be related to elevated intracranial pressure secondary to a cephalad fluid shift. However, ocular symptoms have not been replicated in subjects completing prolonged bed rest, a well-accepted spaceflight analog. Altered vascular compliance along with spaceflight factors such as diet, radiation exposure, or environmental factors may cause alterations in the cardiovascular system that contribute to the manifestation of ocular changes. Loss of visual acuity could be a significant threat to crew health and performance during and after an exploration mission and may have implications for years post-flight. The overall objective of this project is to determine if spaceflight alters vascular compliance and whether such an adaptation is related to the incidence of VIIP. This objective will be met by completing three separate but related projects.

Ribeiro, L. C.↗

Ground-Based Studies of Headward Fluid Shifts Related to Space Flight

Long-term space flight decreases visual acuity in more than 50% of astronauts with some reports of post-flight lumbar opening pressures up to 21 mmHg1. Loss of hydrostatic (gravitational) pressures in microgravity shifts blood, spinal fluid and tissue fluids towards the head, probably causing venous congestion and leading to symptoms compatible with chronically increased intracranial pressure (ICP). This is characterized as the Visual Impairment and Intracranial Pressure (VIIP) syndrome. Simulation of gravitational stress by application of Lower Body Negative Pressure (LBNP) is proposed as a means to reduce ICP and reestablish cerebral health in astronauts during long mission stay in space. We hypothesize that 50 mmHg of lower body negative pressure (LBNP) during supine and simulated intracranial hypertension by 15 deg head-down tilt (HDT) counteracts elevations in ICP and internal jugular vein crosssectional area (IJV CSA).

Petersen, L. G.↗

Transpulmonary passage of venous air emboli

Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

Butler, B. D.↗

A comparison of limb plethysmograph systems proposed for use on the Space Shuttle

Comparisons of a Whitney mercury-filled double-stranded strain gauge with two plethysmographs proposed for Shuttle use - an ultrasound and an impedance plethysmograph - were performed on 20 subjects. An occlusive thigh pressure cuff, inflated to 50 mm Hg, caused partial venous occlusion and subsequent blood pooling distal to the cuff. The average maximum volume changes observed in the Whitney/ultrasound test were 2.07% and 3.35%, respectively, and 2.12% and 2.53% for the Whitney/Impedance comparison. Applying the ratio of the maximum volume changes to the gain of each test system caused the impedance and ultrasound volume change determinations to be essentially identical to the Whitney gauge. The three different limb parameters measured result in significant magnitude differences but the three systems track their respective changes identically.

Levitan, B. M.↗

Risk of Microgravity-Induced Visual Impairment and Elevated Intracranial Pressure (VIIP)

Eight cases identified, represent 23.5% of the 34 crewmembers flown on the ISS, with inflight visual changes and pre-to-postflight refractive changes. In some cases, the changes were transient while in others they are persistent with varying degrees of visual impairment. (1) Decreased intraocular pressure (IOP) postflight was observed in 3 cases. (2) Fundoscopic exams revealed postflight findings of choroidal folds in 4 cases, optic disc edema in 5 cases and presence of cotton wool spots in 3 cases. (3) Optical coherence tomography (OCT) confirmed findings of choroidal folds and disc edema and documented retinal nerve fiber layer thickening (4 cases). (4) Findings from MRI examinations showed posterior globe flattening (5 cases) and optic nerve sheath distension (6 cases). (5) Opening cerebrospinal fluid (CSF) pressure was elevated in 4 cases postflight reflecting raised intracranial pressure. While the etiology remains unknown, hypotheses speculate that venous insufficiency or hypertension in the brain caused by cephalad fluid shifts during spaceflight are possible mechanisms for ocular changes in astronauts.

Otto, Christian↗

Blood flow dynamics in heart failure

BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.

NASA Discipline Cardiopulmonary↗

Cardiovascular dynamics associated with tolerance to lower body negative pressure

The purpose of this investigation was to identify cardiovascular responses associated with tolerance to lower body negative pressure (LBNP). Eighteen men, ages 29-51 years, were categorized as high (HT) or low (LT) LBNP-tolerant based on a graded presyncopal-limited LBNP exposure criterion of -60 mm Hg relative to ambient pressure. Groups were matched for physical characteristics and pre-LBNP cardiovascular measurements, with the exceptions of greater (p less than 0.05) end-diastolic volume and cardiac output in the HT group. During peak LBNP, cardiac output was similar in both groups, although the HT group displayed a greater heart rate (p less than 0.05). In both groups, venous return appeared to limit cardiac output resulting in decreased arterial pressure. Tolerance to LBNP did not appear solely dependent on the absolute amount of blood pooled in the legs since the HT group demonstrated a greater (p less than 0.05) peak LBNP-induced increase in midthigh-leg volume. Greater tolerance to LBNP was associated with a larger pre-LBNP cardiac output reserve and higher compensatory increases in heart rate and peripheral resistance.

Sather, T. M.↗

Intramuscular pressures beneath elastic and inelastic leggings

Leg compression devices have been used extensively by patients to combat chronic venous insufficiency and by astronauts to counteract orthostatic intolerance following spaceflight. However, the effects of elastic and inelastic leggings on the calf muscle pump have not been compared. The purpose of this study was to compare in normal subjects the effects of elastic and inelastic compression on leg intramuscular pressure (IMP), an objective index of calf muscle pump function. IMP in soleus and tibialis anterior muscles was measured with transducer-tipped catheters. Surface compression between each legging and the skin was recorded with an air bladder. Subjects were studied under three conditions: (1) control (no legging), (2) elastic legging, and (3) inelastic legging. Pressure data were recorded for each condition during recumbency, sitting, standing, walking, and running. Elastic leggings applied significantly greater surface compression during recumbency (20 +/- 1 mm Hg, mean +/- SE) than inelastic leggings (13 +/- 2 mm Hg). During recumbency, elastic leggings produced significantly higher soleus IMP of 25 +/- 1 mm Hg and tibialis anterior IMP of 28 +/- 1 mm Hg compared to 17 +/- 1 mm Hg and 20 +/- 2 mm Hg, respectively, generated by inelastic leggings and 8 +/- 1 mm Hg and 11 +/- 1 mm Hg, respectively, without leggings. During sitting, walking, and running, however, peak IMPs generated in the muscular compartments by elastic and inelastic leggings were similar. Our results suggest that elastic leg compression applied over a long period in the recumbent posture may impede microcirculation and jeopardize tissue viability.(ABSTRACT TRUNCATED AT 250 WORDS).

Clinical Trial↗

Combining Information on Multiple Detection Techniques to Estimate the Effect of Patent Foramen Ovale on Susceptibility to Decompression Illness

The assembly and the maintenance of the International Space Station is expected to require hundreds of extravehicular excursions (EVA's) in the next 10 years. During an EVA, in order to allow movement and bending of limbs, spacesuit pressures are reduced to about 4.3 psi. as compared with about 14.7 psi. for normal atmospheric pressure at sea level. However, the exposure of astronauts to reduced pressures in spacesuits, is conducive to fonnation and growth of gas bubbles within venous blood or tissues, which could cause decompression illness (DCI), a pathology best known to occur among deep-sea divers when they return to the surface. To reduce the risk of DCI, astronauts adjust to the reduced pressure in stages for a prolonged time known as a "pre-breathe" period prior to their extravehicular activity. Despite the use of pre-breathe protocols, an increased risk of DCI can arise for about 25% of humans who have a small hole, known as a patent foramen ovale (PFO), between two chambers of the heart. The atrial septum's fossa oval is, an embryological remnant of a flap between the septae primum and secundum allows fetal right atrial blood to pass into the left atrium, and usually closes after birth (Hagen, et al,. 1984). If fusion does not occur, a valve-like opening, the foramen ovale persists between the two atria. It has been suggested that astronauts with PFO's might be at greater risk of stroke or other serious neurological DCI because bubbles from a venous site may traverse a PFO, travel to the aorta and then enter the cerebral circulatory system causing a stroke (Figure 1). Astronauts are not now screened for PFO's, however consideration is being given to doing so. Here, we study three main methods abbreviated here as "ITE", "TCD" and "TEE", for detecting PFO's in living subjects. All involve the introduction of bubbles into a vein, immediately after which a sensory probe attempts to detect the bubbles in systemic circulation. Presence of the injected bubbles in the systemic circulation is indicative of a PFO. More detailed descriptions are given after the explanation of PFO's under Figure I. Even if a true PFO affects the risk of DCI, there remains a question of how effective screening would be if the detection method has errors of omission and/or commission. Of the three methods studied here, TEE is the "gold standard", matching autopsy results with near-perfect sensitivity and specificity (Schneider, et al. , 1996). However TEE is also the most difficult method to implement, requiring an internal esophagal probe, and is therefore not widely used. Currently, the easiest to use and most common PFO detection method is TTE, which uses an external chest probe. This method has a specificity of near 100%, but suffers from a low sensitivity rate (about 30%). More recently, TCD has been developed, which uses ultrasound probes to detect the presence of bubbles in cerebral arteries. Studies indicate that TCD is quite effective, having a sensitivity of about 91% and a specificity of about 93% (Droste, et al., 1999) when applied correctly, however implementation is difficult and requires considerable training.

Feiveson, Alan H.↗

A computational model-based validation of Guyton's analysis of cardiac output and venous return curves

Guyton developed a popular approach for understanding the factors responsible for cardiac output (CO) regulation in which 1) the heart-lung unit and systemic circulation are independently characterized via CO and venous return (VR) curves, and 2) average CO and right atrial pressure (RAP) of the intact circulation are predicted by graphically intersecting the curves. However, this approach is virtually impossible to verify experimentally. We theoretically evaluated the approach with respect to a nonlinear, computational model of the pulsatile heart and circulation. We developed two sets of open circulation models to generate CO and VR curves, differing by the manner in which average RAP was varied. One set applied constant RAPs, while the other set applied pulsatile RAPs. Accurate prediction of intact, average CO and RAP was achieved only by intersecting the CO and VR curves generated with pulsatile RAPs because of the pulsatility and nonlinearity (e.g., systemic venous collapse) of the intact model. The CO and VR curves generated with pulsatile RAPs were also practically independent. This theoretical study therefore supports the validity of Guyton's graphical analysis.

NASA Discipline Cardiopulmonary↗

Numerical simulation of the influence of gravity and posture on cardiac performance

A numerical model of the cardiovascular system was used to quantify the influences on cardiac function of intrathoracic pressure and intravascular and intraventricular hydrostatic pressure, which are fundamental biomechanical stimuli for orthostatic response. The model included a detailed arterial circulation with lumped parameter models of the atria, ventricles, pulmonary circulation, and venous circulation. The venous circulation was divided into cranial, central, and caudal regions with nonlinear compliance. Changes in intrathoracic pressure and the effects of hydrostatic pressure were simulated in supine, launch, sitting, and standing postures for 0, 1, and 1.8 G. Increasing intrathoracic pressure experienced with increasing gravity caused 12% and 14% decreases in cardiac output for 1 and 1.8 G supine, respectively, compared to 0 G. Similar results were obtained for launch posture, in which the effects of changing intrathoracic pressure dominated those of hydrostatic pressure. Compared to 0 G, cardiac output decreased 0.9% for 1 G launch and 15% for 1.8 G launch. In sitting and standing, the position of the heart above the hydrostatic indifference level caused the effects of changing hydrostatic pressure to dominate those of intrathoracic pressure. Compared to 0 G, cardiac output decreased 13% for 1 G sitting and 23% for 1.8 G sitting, and decreased 17% for 1 G standing and 31% for 1.8 G standing. For a posture change from supine to standing in 1 G, cardiac output decreased, consistent with the trend necessary to explain orthostatic intolerance in some astronauts during postflight stand tests. Simulated lower body negative pressure (LBNP) in 0 G reduced cardiac output and mean aortic pressure similar to I G standing, suggesting that LBNP provides at least some cardiovascular stimuli that may be useful in preventing postflight orthostatic intolerance. A unifying concept, consistent with the Frank-Starling mechanism of the heart, was that cardiac output was proportional to cardiac diastolic transmural pressure for all postures and gravitational accelerations.

Non-NASA Center↗

A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

NASA Discipline Number 14-10↗

[Quantification and monitoring of vascular resistance in the lower limbs by the Doppler method (animal model)]

The object of this study was to define and validate a non-invasive method of evaluation and monitoring of vascular resistances in the leg. Blood flow velocity was measured by Doppler ultrasound in an animal model (ewe) with similar blood flow characteristics in the lower limb as man and allowing access to the required invasive measurements for validation of the method (pressure and flow). Vascular resistances distal to the measuring point (femoral, for example) were assessed using the resistance index R = D/S, S being the peak systolic deflection and D that of diastolic reflux of the Doppler spectral analysis of flow in the femoral artery. The values and variations of this resistance index were compared with the vascular resistances calculated from measurements of pressure and flow at the point of Doppler sampling and expressed in mmHg/ml/min. Femoral flow was measured by Doppler ultrasound (Doppler-echo), and mean pressure by an arterial catheter introduced into the abdominal aorta. Compression of the lower limb veins induced a venous return resulting in a reduction of cardiac output and femoral flow. During compression, femoral flow decreased by an average of 29% (p < 0.001) although mean pressure and heart rate did not change significantly. The femoral resistance index (Rf) increased by an average of 37.5% (p < 0.01) and vascular resistances increased by 45.9% (p < 0.01). Injection of 1 mg adrenaline induced peripheral vasoconstriction with an increase in blood pressure and a decrease in heart rate and femoral flow.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Promethazine affects autonomic cardiovascular mechanisms minimally

Promethazine hydrochloride, Phenergan, is a phenothiazine derivative with antihistaminic (H1), sedative, antiemetic, anticholinergic, and antimotion sickness properties. These properties have made promethazine a candidate for use in environments such as microgravity, which provoke emesis and motion sickness. Recently, we evaluated carotid baroreceptor-cardiac reflex responses during two Space Shuttle missions 18 to 20 hr after the 50 mg intramuscular administration of promethazine. Because the effects of promethazine on autonomic cardiovascular mechanisms in general and baroreflex function in particular were not known, we were unable to exclude a possible influence of promethazine on our results. Our purpose was to determine the ground-based effects of promethazine on autonomic cardiovascular control. Because of promethazine's antihistaminic and anticholinergic properties, we expected that a 50-mg intramuscular injection of promethazine would affect sympathetically and vagally mediated cardiovascular mechanisms. Eight healthy young subjects, five men and three women, were studied at rest in recumbency. All reported drowsiness as a result of the promethazine injection; most also reported nervous excitation, dry mouth, and fatigue. Three subjects had significant reactions: two reported excessive anxiety and one reported dizziness. Measurements were performed immediately prior to injection and 3.1 +/- 0.1 and 19.5 +/- 0.4 hr postinjection. We found no significant effect of promethazine on resting mean R-R interval, arterial pressure, R-R interval power spectra, carotid baroreflex function, and venous plasma catecholamine levels.

Clinical Trial↗

Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli

Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.

Butler, B. D.↗