Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

60 APPLIED LIFE SCIENCES↗

CODE-TO-CODE BENCHMARK STUDY FOR THERMAL STRESS MODELING AND PRELIMINARY ANALYSIS OF THE HIGH-TEMPERATURE SINGLE HEAT PIPE EXPERIMENT

Microreactors are very small nuclear reactors with typical thermal-energy output of up to 20 MWth. The microreactor concept is gaining more and more attention for safe, robust, and reliable supply of electricity for remote locations and to meet industrial process heat needs. Heat-pipe-cooled microreactor is one of the microreactors being investigated at Idaho National Laboratory. In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios for the heat-pipe-cooled microreactor designs. This paper discusses finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory, using two commercial software packages, Abaqus and STAR-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the locations where the largest temperature gradients appeared between heat pipe and electric heater. The temperature fields have good agreements between Abaqus and STAR-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonlinear three-dimensional verification of the $\small \mathrm{SPECYL}$ and $\small \mathrm{PIXIE3D}$ magnetohydrodynamics codes for fusion plasmas

With the increasing impact of scientific discovery via advanced computation, there is presently a strong emphasis on ensuring the mathematical correctness of computational simulation tools. Such endeavor, termed verification, is now at the center of most serious code development efforts. In this study, we address a cross-benchmark nonlinear verification study between two three-dimensional magnetohydrodynamics (3D MHD) codes for fluid modeling of fusion plasmas, SPECYL [S. Cappello and D. Biskamp, Nucl. Fusion 36, 571 (1996)] and PIXIE3D [L. Chacón, Phys. Plasmas 15, 056103 (2008)], in their common limit of application: the simple viscoresistive cylindrical approximation. SPECYL is a serial code in cylindrical geometry that features a spectral formulation in space and a semi-implicit temporal advance, and has been used extensively to date for reversed-field pinch studies. PIXIE3D is a massively parallel code in arbitrary curvilinear geometry that features a conservative, solenoidal finite-volume discretization in space, and a fully implicit temporal advance. The present study is, in our view, a first mandatory step in assessing the potential of any numerical 3D MHD code for fluid modeling of fusion plasmas. Finally, excellent agreement is demonstrated over a wide range of parameters for several fusion-relevant cases in both two- and three-dimensional geometries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the Spatio-Temporal Variability in Subsurface Thermal Regimes Across a Low-Relief Polygonal Tundra Landscape: Modeling Archive

Vast carbon stocks stored in permafrost soils of Arctic tundra are under risk of release to atmosphere under warming climate. Ice--wedge polygons in the low-gradient polygonal tundra create a complex mosaic of microtopographic features. The microtopography plays a critical role in regulating the fine scale variability in thermal and hydrological regimes in the polygonal tundra landscape underlain by continuous permafrost. Modeling of thermal regimes of this sensitive ecosystem is essential for understanding the landscape behaviour under current as well as changing climate. We present here an end-to-end effort for high resolution numerical modeling of thermal hydrology at real-world field sites, utilizing the best available data to characterize and parameterize the models. We develop approaches to model the thermal hydrology of polygonal tundra and apply them at four study sites at Barrow, Alaska spanning across low to transitional to high-centered polygon and representative of broad polygonal tundra landscape. A multi--phase subsurface thermal hydrology model (PFLOTRAN) was developed and applied to study the thermal regimes at four sites. Using high resolution LiDAR DEM, microtopographic features of the landscape were characterized and represented in the high resolution model mesh. Best available soil data from field observations and literature was utilized to represent the complex heterogeneous subsurface in the numerical model. This data collection provides the complete set of input files, forcing data sets and computational meshes for simulations using PFLOTRAN for four sites at Barrow Environmental Observatory. It also documents the complete computational workflow for this modeling study to allow verification, reproducibility and follow up studies. This dataset includes two zipped files and one .pdf file.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Two-Black Box Concept for Warhead Verification

We have created a possible solution to meeting the requirements of certification/authentication while still employing complicated criteria. Technical solutions to protecting information from the host in an inspection environment needs to be assessed by those with specific expertise but, LANL can still study the verification problem. The two-black box framework developed provides another potential solution to the confidence vs. certification paradox.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

[Presentation Slides] Code-to-Code Benchmark Study for Thermal Stress Modeling and Preliminary Analysis of the High-temperature Single Heat-Pipe Experiment

In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios. This presentation slides discuss finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL), using two commercial software packages, Abaqus and Star-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain preliminary insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the inner surface of the heat pipe hole surrounded by electric heaters where the largest temperature gradients appear. The temperature fields have good agreements between Abaqus and Star-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes. It is found that the local maximum thermal stresses may reach close to the ultimate tensile strength and yield strength of structural material depending on the heater power. Ultimately, the coupled thermal-structural analysis will help guide the current experimental plan and ensure the facility safety for future experimental study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A statistical approach for isolating fossil fuel emissions in atmospheric inverse problems

We study independent verification and quantification of fossil fuel (FF) emissions that constitutes a considerable scientific challenge. By coupling atmospheric observations of CO 2 with models of atmospheric transport, inverse models offer the possibility of overcoming this challenge. However, disaggregating the biospheric and FF flux components of terrestrial fluxes from CO 2 concentration measurements has proven to be difficult, due to observational and modeling limitations. In this study, we propose a statistical inverse modeling scheme for disaggregating winter time fluxes on the basis of their unique error covariances and covariates, where these covariances and covariates are representative of the underlying processes affecting FF and biospheric fluxes. The application of the method is demonstrated with one synthetic and two real data prototypical inversions by using in situ CO 2 measurements over North America. Also, inversions are performed only for the month of January, as predominance of biospheric CO 2 signal relative to FF CO 2 signal and observational limitations preclude disaggregation of the fluxes in other months. The quality of disaggregation is assessed primarily through examination of a posteriori covariance between disaggregated FF and biospheric fluxes at regional scales. Findings indicate that the proposed method is able to robustly disaggregate fluxes regionally at monthly temporal resolution with a posteriori cross covariance lower than 0.15 µmol m -2 s -1 between FF and biospheric fluxes. Error covariance models and covariates based on temporally varying FF inventory data provide a more robust disaggregation over static proxies (e.g., nightlight intensity and population density). However, the synthetic data case study shows that disaggregation is possible even in absence of detailed temporally varying FF inventory data.

54 ENVIRONMENTAL SCIENCES↗

Replication Package for "Union-Find and Usability: A Case Study and Analysis of Rust Formal Verifier

This replication package is a case study on automated deductive verification for Rust for practical programs. It is a companion artifact to a corresponding usability study on verification titled "Union-Find and Usability: A Case Study and Analysis of Rust Formal Verifiers". It seeks to answer the question "Can Rust developers today use Rust verifiers to verify their code?". To answer this question, the study contrasts the verification experience of two mature Rust verifiers, Creusot and Prusti, by using the tools to develop a verified implementation of union-find in Rust. The union-find implementation is based on real-world code as used in the popular egg E-graph library. The artifact consists of two different verified libraries, one using Creusot and one using Prusti. The libraries have similar Rust interfaces and high-level proofs but differ in their details: Creusot and Prusti have different annotation languages and support different proof styles. Each implementation can be verified with its respective tool and compiles as a traditional Rust development.

Sarracino, John↗

Development and Verification of Tritium Analyses Code for a Very High Temperature Reactor

A tritium permeation analyses code (TPAC) has been developed by Idaho National Laboratory for the purpose of analyzing tritium distributions in the VHTR systems including integrated hydrogen production systems. A MATLAB SIMULINK software package was used for development of the code. The TPAC is based on the mass balance equations of tritium-containing species and a various form of hydrogen (i.e., HT, H2, HTO, HTSO4, and TI) coupled with a variety of tritium source, sink, and permeation models. In the TPAC, ternary fission and neutron reactions with 6Li, 7Li 10B, 3He were taken into considerations as tritium sources. Purification and leakage models were implemented as main tritium sinks. Permeation of HT and H2 through pipes, vessels, and heat exchangers were importantly considered as main tritium transport paths. In addition, electroyzer and isotope exchange models were developed for analyzing hydrogen production systems including both high-temperature electrolysis and sulfur-iodine process. The TPAC has unlimited flexibility for the system configurations, and provides easy drag-and-drops for making models by adopting a graphical user interface. Verification of the code has been performed by comparisons with the analytical solutions and the experimental data based on the Peach Bottom reactor design. The preliminary results calculated with a former tritium analyses code, THYTAN which was developed in Japan and adopted by Japan Atomic Energy Agency were also compared with the TPAC solutions. This report contains descriptions of the basic tritium pathways, theory, simple user guide, verifications, sensitivity studies, sample cases, and code tutorials. Tritium behaviors in a very high temperature reactor/high temperature steam electrolysis system have been analyzed by the TPAC based on the reference indirect parallel configuration proposed by Oh et al. (2007). This analysis showed that only 0.4% of tritium released from the core is transferred to the product hydrogen. The amount of tritium in the product hydrogen was estimated to be approximately an order less than the gaseous effluent limit for tritium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-E-T-32: An Application of GafChromic RTQA2 Film to the Patient Specified Quality Assurance

Purpose: GafChromic RTQA2 film is known as a quality assurance (QA) tool for light field and radiation field verification. This study is attempted to apply the RTQA2 film to the patient specified quality assurance. Methods: Pre-irradiated and post-irradiated RTQA2 films were scanned in a reflection mode using a flatbed scanner. A plan-based dose calibration method utilized the mapping information of calculated dose image and measured film image to create a dose vs. pixel value calibration model. This model was used to calibrate the measured film image from the pixel value (gray value) image to the dose image. The dose agreement between calculated and measured dose images were analyzed using the gamma analysis. To evaluate the feasibility of this method, three clinical approved RapidArc cases (one abdomen cancer and two head-and-neck cancer patients) were tested. The tolerance of 3% dose difference and 3 mm distance to agreement (DTA) and gamma index ≤ 1 were set for the analysis. Results: The calibrated film dose image from measurement was successfully compared to the predicted dose image from the commercial treatment planning. The gamma analysis results showed good consistency. Gamma passing rates were 99.02%, 94.84%, and 98.33% for the three patients, respectively. Conclusion: The plan based calibration method has the feasibility for dose verification without shortages of film batch and development time variation.

60 APPLIED LIFE SCIENCES↗

Evaluation of RMI Ejecta Sourcing from Reconstructed Interfaces in 2D FLAG Flyer-Plate Simulations

This study investigates the performance of RMI ejecta sourcing from a reconstructed interface in two-dimensional FLAG ejecta flyer-plate simulations. Enabling the RMI ejecta model to operate on reconstructed interfaces has been a longstanding challenge in FLAG, limiting its applicability to experiments in which interface reconstruction is not required. Addressing this limitation is therefore an important step toward expanding the model’s predictive capability. The first phase of this effort focused on identifying a flyer-plate/target configuration that produces large ejecta clouds from two distinct shocks using the standard RMI ejecta model. A series of simulations examined the effects of flyer composition, layer thickness, and mesh resolution on shock structure and ejecta formation. VISAR traces were used to evaluate shock timing and identify configurations that produced a clear double-shock response. A copper middle-layer flyer with a doubled tin layer yielded the most favorable shock characteristics and was selected as the baseline configuration. After confirming this configuration performed as expected when running a reference FLAG version, it became the basis for three simulations: (1) a standard two-dimensional ejecta flyer-plate calculation using a reference FLAG version, (2) the same calculation with the reconstructed interface option enabled, and (3) a calculation employing ALE strategies to force the ejecta model to operate on the reconstructed interface. While the baseline simulation produced the expected ejecta response, the reconstructed interface approach did not result in measurable ejecta, indicating that this capability remains under development. These results highlight both the progress made and the remaining challenges in extending the RMI ejecta model to reconstructed interfaces.

36 MATERIALS SCIENCE↗

TU-FG-BRB-06: A Prompt Gamma-Ray Spectroscopy System for Clinical Studies of in Vivo Proton Range Verification

Purpose: We present a new system to perform prompt gamma-ray spectroscopy during proton pencil-beam scanning treatments, which enables in vivo verification of the proton range. This system will be used for the first clinical studies of this technology. Methods: After successful pre-clinical testing of prompt gamma-ray spectroscopy, a full scale system for clinical studies is now being assembled. Prompt gamma-rays will be detected during patient treatment using an array of 8 detector modules arranged behind a tungsten collimator. Each detector module consists of a lanthanum(III) bromide scintillator, a photomultiplier tube, and custom electronics for stable high voltage supply and signal amplification. A new real-time data acquisition and control system samples the signals from the detectors with analog-to-digital converters, analyses events of interest, and communicates with the beam delivery systems. The timing of the detected events was synchronized to the cyclotron radiofrequency and the pencil-beam delivery. Range verification is performed by matching measured energy- and timeresolved gamma-ray spectra to nuclear reaction models based on the clinical treatment plan. Experiments in phantoms were performed using clinical beams in order to assess the performance of the systems. Results: The experiments showed reliable real-time analysis of more than 10 million detector events per second. The individual detector modules acquired accurate energy- and time-resolved gamma-ray measurements at a rate of 1 million events per second, which is typical for beams delivered with a clinical dose rate. The data acquisition system successfully tracked the delivery of the scanned pencil-beams to determine the location of range deviations within the treatment field. Conclusion: A clinical system for proton range verification using prompt gamma-ray spectroscopy has been designed and is being prepared for use during patient treatments. We anticipate to start a first clinical study in the near future. This work was supported by the Federal Share of program income earned by Massachusetts; General Hospital on C06-CA059267, Proton Therapy Research and Treatment Center.

60 APPLIED LIFE SCIENCES↗

Automated phase segmentation and quantification of high-resolution TEM image for alloy design

In the alloy design and development process, a wealth of atomically resolved structural high-resolution transmission electron microscopy (HRTEM) images are produced. Identifying the different nano-precipitate phases and tracking their evolution under various compositions and during manufacturing or post-processing requires hundreds of HRTEM images and thousands of precipitates. The nanoscopic phase information labeling and analysis purely relies on humans are prohibitively costly and time-consuming, sometimes not reliable because of the lack of authoritative knowledge. Here, in this work, we develop a novel unsupervised machine learning approach coupled with adaptive computer vision techniques with features in the Fourier space to automatically determine the number of phases and segment/quantify the phases with nanoscale resolution, allowing for quantitative correlation between nanostructure formation, processing and functional properties. To automate the phase extraction/quantification and ascertain its applicability, we have applied the developed framework to the HRTEM images from several alloy systems, processing conditions, image magnifications, and phase types and morphologies (precipitates, nano-twins, stacking faults, crystalline matrix, and amorphous structures) for verification. This study paves the road for compression, visualization, and translation of raw image structural data into physically relevant information in real-time with minimal human supervision. It shows the promise of enabling high-throughput materials characterization for the acceleration of alloy manufacturing and design.

36 MATERIALS SCIENCE↗

A tissue dose-based comparative exposure assessment of manganese using physiologically based pharmacokinetic modeling—The importance of homeostatic control for an essential metal

A physiologically-based pharmacokinetic (PBPK) model (Schroeter et al., 2011) was applied to simulate target tissue manganese (Mn) concentrations following occupational and environmental exposures. These estimates of target tissue Mn concentrations were compared to determine margins of safety (MOS) and to evaluate the biological relevance of applying safety factors to derive acceptable Mn air concentrations. Mn blood concentrations measured in occupational studies permitted verification of the human PBPK models, increasing confidence in the resulting estimates. Mn exposure was determined based on measured ambient air Mn concentrations and dietary data in Canada and the United States (US). Incorporating dietary and inhalation exposures into the models indicated that increases in target tissue concentrations above endogenous levels only begin to occur when humans are exposed to levels of Mn in ambient air (i.e. > 10 μg/m{sup 3}) that are far higher than those currently measured in Canada or the US. A MOS greater than three orders of magnitude was observed, indicating that current Mn air concentrations are far below concentrations that would be required to produce the target tissue Mn concentrations associated with subclinical neurological effects. This application of PBPK modeling for an essential element clearly demonstrates that the conventional application of default factors to “convert” an occupational exposure to an equivalent continuous environmental exposure, followed by the application of safety factors, is not appropriate in the case of Mn. PBPK modeling demonstrates that the relationship between ambient Mn exposures and dose-to-target tissue is not linear due to normal tissue background levels and homeostatic controls. - Highlights: • Manganese is an essential nutrient, adding complexity to its risk assessment. • Nonlinearities in biological processes are important for manganese risk assessment. • A PBPK model was used to estimate target tissue concentrations of manganese. • An MOS approach also considered target tissue concentrations for ambient exposures. • Relationships between ambient Mn exposures and dose-to-target tissue are not linear.

60 APPLIED LIFE SCIENCES↗

The injection efficiency measurement and analysis for central region model cyclotron

At the China Institute of Atomic Energy, a central region model cyclotron has been constructed, which is dedicated for various experimental verifications to study beam properties. The design features of the ion source and injection line have already been described in other papers. We shall report here the results of the initial beam tests. A wire scanner is employed in the injection line to measure beam transverse sizes and these data can be used to fit the phase plane parameters after the ion source. Based on the beam tests results, the ion source built in 2003 has been improved recently. The improvement is mainly due to the repair of the multicusp field. From the ion source to the exit of the inflector, a transmission efficiency of 93% has been obtained for a continuous and low current input beam. It is also described here the experimental arrangement and the results.

43 PARTICLE ACCELERATORS↗

HPC Software Verification in Action: A Case Study with Tensor Transposition

As HPC platforms get increasingly complex, the complexity of software optimized for these platforms has also increased. There is a pressing need to ensure correctness of scientific applications to enhance our confidence in the results they produce. In this paper, we focus on checking the correctness of libraries providing a small but important functionality— tensor transposition—used in computational chemistry applications. While several correctness tools have been developed and deployed, there are several practical challenges in using them to verify production HPC software. We present our experiences using two tools—CIVL and CodeThorn—in checking the correctness of two index permutation libraries.

Model checking, equivalence checking, index permut↗

Robust Solution Verification Experiments on Nonuniform Meshes

The activities of verification, validation, and uncertainty quantification (VVUQ) provide a comprehensive means to assess the credibility of computational models. Within VVUQ, solution verification assesses numerical errors and evaluates whether the simulation is sufficiently accurate for its intended applications. As computational modeling gains traction in the development of complex, high-consequence systems, the need for robust solution verification intensifies, particularly because experimental data for these systems are often limited. This work examines improvements in the robustness of Richardson extrapolation (RE), a method commonly used in solution verification to study the discretization error of computational models using a power law. Nonuniform mesh refinement is discussed alongside other pollutants that affect the robustness of the power law model. Maximum likelihood estimation (MLE) is proposed as a robust strategy to address the uncertainty generated by nonuniform mesh refinement. An exploratory computational fluid dynamics (CFD) study of a 2D planar Poiseuille flow is conducted to determine if nonuniform mesh noise can be modeled with this MLE approach for more robust RE.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

60 APPLIED LIFE SCIENCES↗