Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Attenuation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Dust coagulation in ISM

Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.

Chokshi, Arati↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Optimal Control Design using an H(sub 2) Method for the Glovebox Integrated Microgravity Isolation Technology (G-Limit)

The acceleration environment on the International Space Station (ISS) will likely exceed the requirements of many micro-gravity experiments. The Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) is being built by the NASA Marshall Space Flight Center to attenuate the nominal acceleration environment and provide some isolation for microgravity science experiments. G-LIMIT uses Lorentz (voice-coil) magnetic actuators to isolate a platform for mounting science payloads from the nominal acceleration environment. The system utilizes payload acceleration, relative position, and relative orientation measurements in a feedback controller to accomplish the vibration isolation task. The controller provides current commands to six magnetic actuators, producing the required experiment isolation from the ISS acceleration environment. This paper presents the development of a candidate control law to meet the acceleration attenuation requirements for the g-LIMIT experiment platform. The controller design is developed using linear optimal control techniques for frequency-weighted H(sub 2) norms. Comparison of the performance and robustness to plant uncertainty for this control design approach is included in the discussion.

Calhoun, Philip C.↗

Optimal Control Design Using an H2 Method for the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT)

The acceleration environment on the International Space Station (ISS) will likely exceed the requirements of many micro-gravity experiments. The Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) is being built by the NASA Marshall Space Flight Center to attenuate the nominal acceleration environment and provide some isolation for micro-gravity science experiments. G-LIMIT uses Lorentz (voice-coil) magnetic actuators to isolate a platform for mounting science payloads from the nominal acceleration environment. The system utilizes payload acceleration, relative position, and relative orientation measurements in a feedback controller to accomplish the vibration isolation task. The controller provides current command to six magnetic actuators, producing the required experiment isolation from the ISS acceleration environment. This paper presents the development of a candidate control law to meet the acceleration attenuation requirements for the g-LIMIT experiment platform. The controller design is developed using linear optimal control techniques for both frequency-weighted H(sub 2) and H(sub infinity) norms. Comparison of the performance and robustness to plant uncertainty for these two optimal control design approaches are included in the discussion.

Calhoun, Phillip C.↗

Characterization of Embedded Sensors in Stainless Steel Test Articles and Design/Planning for MAGNET Testing

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes for heat rejection, which results in significant thermal stresses in the monolithic structures. This work describes the initial characterization and test plan for evaluating stainless steel test articles fabricated with embedded sensors for measuring heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing. The electrically heated testing will be performed in the non-nuclear Microreactor Agile Non-Nuclear Testbed and Single Primary Heat Extraction and Removal Emulator facilities located at Idaho National Laboratory. The goals of these tests are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. More generally, the ability to monitor component and system health during microreactor operation is attractive for providing a high sensor density to inform a limited number of microreactor operators to ultimately reduce operation and maintenance costs and move toward semi-autonomous operation. This report discusses the characterization of embedded thermocouples and fiber optic sensors in relevant test articles, including cylindrical pipes and hexagonal monolithic test articles for heat pipe-based reactors. The sensors were embedded by placing them in machined channels and then building up additional material by using ultrasonic additive manufacturing (UAM). UAM is a solid-state welding process that uses downward pressure and a lateral scrubbing motion to bond thin metal foils to a base material layer by layer. The ultrasonic welding process relies on the plastic deformation of the metal—as opposed to typical melting and solidification—to break oxide scales and bond the metal layers. The characterization of these embedded sensors included evaluating fiber optic signal attenuation, observing residual strain in the fibers, investigating microstructural and mechanical aspects, and demonstrating the sensors under various thermal loads and acoustic vibrations. Post-embedding characterization showed a fine grain structure (<1 μm) near the interfaces of the bonded foils as a result of severe deformation from the welding process. A large increase in hardness was observed at the foil interfaces and the fiber/matrix interface compared with the bulk matrix. Even when compared with the SS304 interfaces, the higher hardness observed around the embedded fiber suggests a higher degree of deformation due to the soft metal coating around the silica fiber core. The distributed fiber-optic temperature sensors and embedded thermocouples reliably measured temperature distributions during steady-state and transient thermal testing. The embedded fiber-optic sensors reliably measured strain during both transient and steady-state testing and properly identified resonant frequencies during acoustic testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Extended H2 synthesis for microgravity vibration isolation

The vibration environment onboard current and planned manned orbiters requires isolation for microgravity science experiments. The disturbance frequencies are sufficiently low and the attenuation requirements sufficiently great so as to preclude a passive isolation system. Described here is a design procedure, known as extended H2 synthesis, for active isolation system controllers currently being developed by the University of Virginia.

Hampton, R. David↗

Frequency Weighted H2 Control Design for the Glovebox Integrated Microgravity Isolation Technology (g-LIMIT)

The acceleration environment on the International Space Station (ISS) exceeds the requirements of many microgravity experiments. The Glovebox Integrated Microgravity Isolation Technology (g-LIMIT) has been built by the NASA Marshall Space Flight Center to attenuate the nominal acceleration environment and provide some isolation for microgravity science experiments. The g-LIMIT uses Lorentz (voice-coil) magnetic actuators to isolate a platform, for mounting science payloads, from the nominal acceleration environment. The system utilizes payload-acceleration, relative-position, and relative-orientation measurements in a feedback controller to accomplish the vibration isolation task. The controller provides current commands to six magnetic actuators, producing the required experiment isolation from the ISS acceleration environment. The present work documents the development of a candidate control law to meet the acceleration attenuation requirements for the g-LIMIT experiment platform. The controller design is developed using linear optimal control techniques for frequency-weighted H2 norms. Comparison of performance and robustness to plant uncertainty for this control design approach is included in the discussion. System performance is demonstrated in the presence of plant modeling error.

Calhoun, Philip C.↗

An investigation of hydraulic-line resonance and its attenuation

An investigation of fluid resonance in high-pressure hydraulic lines has been made with two types of fluid dampers (or filters) installed in the line. One type involved the use of one or more closed-end tubes branching at right angles from a main line, and the other type was a fluid muffler installed in-line. These devices were evaluated in forced vibration tests with oscillatory disturbances over a 1000-Hz range applied to one end of the line and with oscillatory pressures measured at various stations along the main pipe. Limited applications of acoustic-wave theory to the branched systems are also included. Results show varying attenuations of pressure perturbations, depending on the number and location of branches and the type of muffler. Up to three branches were used in the branch-resonator study, and the largest frequency range with maximum attenuation was obtained for a three-branch configuration. The widest frequency ranges with significant attenuations were obtained with two types of fluid mufflers.

Sewall, J. L.↗

Bio-inspired non self-similar hierarchical elastic metamaterials

Hierarchy provides unique opportunities for the design of advanced materials with superior properties that arise from architecture, rather than from constitutive material response. Contrary to the quasi-static regime, where the potential of hierarchy has been largely explored, its role in vibration mitigation and wave manipulation remains elusive. So far, the majority of the studies concerning hierarchical elastic metamaterials have proposed a self-similar repetition of a specific unit cell at multiple scale levels, leading to the activation of the same bandgap mechanism at different frequencies. On the contrary, here, we show that by designing non self-similar hierarchical geometries allows us to create periodic structures supporting multiple, highly attenuative and broadband bandgaps involving (independently or simultaneously) different scattering mechanisms, namely, Bragg scattering, local resonance and/or inertial amplification, at different frequencies. The type of band gap mechanism is identified and discussed by examining the vibrational mode shapes and the imaginary component of the wavenumber in the dispersion diagram of the unit cell. Finally, we also experimentally confirm this by performing measurements in the lowest frequency regime on a 3D printed structure. Hierarchical design strategies may find application in vibration mitigation for civil, aerospace and mechanical engineering.

36 MATERIALS SCIENCE↗

Active control of sound radiation from a vibrating rectangular panel by sound sources and vibration inputs - An experimental comparison

Active control of sound radiation from a rectangular panel by two different methods has been experimentally studied and compared. In the first method a single control force applied directly to the structure is used with a single error microphone located in the radiated acoustic field. Global attenuation of radiated sound was observed to occur by two main mechanisms. For 'on-resonance' excitation, the control force had the effect of increasing the total panel input impedance presented to the nosie source, thus reducing all radiated sound. For 'off-resonance' excitation, the control force tends not significantly to modify the panel total response amplitude but rather to restructure the relative phases of the modes leading to a more complex vibration pattern and a decrease in radiation efficiency. For acoustic control, the second method, the number of acoustic sources required for global reduction was seen to increase with panel modal order. The mechanism in this case was that the acoustic sources tended to create an inverse pressure distribution at the panel surface and thus 'unload' the panel by reducing the panel radiation impedance. In general, control by structural inputs appears more effective than control by acoustic sources for structurally radiated noise.

Fuller, C. R.↗

Acoustic plane waves normally incident on a clamped panel in a rectangular duct

The theory of acoustic plane wave normally incident on a clamped panel in a rectangular duct is developed. The coupling theory between the elastic vibrations of the panel (plate) and the acoustic wave propagation in infinite space and in the rectangular duct is considered. The partial differential equation which governs the vibration of the panel (plate) is modified by adding to its stiffness (spring) forces and damping forces, and the fundamental resonance frequency and the attenuation factor are discussed. The noise reduction expression based on the theory is found to agree well with the corresponding experimental data of a sample aluminum panel in the mass controlled region, the damping controlled region, and the stiffness controlled region. All the frequency positions of the upward and downward resonance spikes in the sample experimental data are identified theoretically as resulting from four cross interacting major resonance phenomena: the cavity resonance, the acoustic resonance, the plate resonance, and the wooden back panel resonance.

Unz, H.↗

Development of monofilar rotor hub vibration absorber

A design and ground test program was conducted to study the performance of the monofilar absorber for vibration reduction on a four-bladed helicopter. A monofilar is a centrifugal tuned two degree-of-freedom rotor hub absorber that provides force attenuation at two frequencies using the same dynamic mass. Linear and non-linear analyses of the coupled monofilar/airframe system were developed to study tuning and attenuation characteristics. Based on the analysis, a design was fabricated and impact bench tests verified the calculated non-rotating natural frequencies and mode shapes. Performance characteristics were measured using a rotating absorber test facility. These tests showed significant attenuation of fixed-system 4P hub motions due to 3P inplane rotating-system hub forces. In addition, detuning effects of the 3P monofilar modal response were small due to the nonlinearities and tuning pin slippage. However, attenuation of 4P hub motions due to 5P inplane hub forces was poor. The performance of the 5P monofilar modal response was degraded by torsional motion of the dynamic mass relative to the support arm which resulted in binding of the dynamic components. Analytical design studies were performed to evaluate this torsional motion problem. An alternative design is proposed which may alleviate the torsional motion of the dynamic mass.

Duh, J.↗

Active control of interior noise in model aircraft fuselages using piezoceramic actuators

Active control of interior noise in model aircraft fuselages using piezoceramic actuators is experimentally studied. The actuators are bonded directly to the structure and error information is taken from up to two microphones located in the interior acoustic field. The results demonstrate that global attenuation of the order of 10 to 15 dB of interior noise can be achieved with piezoceramic actuators, irrespective of whether the shell system is vibrating at an acoustic or structural resonant frequency. The work also proves that active control using vibration (moment) inputs works well when a floor simulating that of an aircraft is installed in the model. This result suggests that the technique will be successful in controlling interior noise in realistic aircraft structures.

Fuller, C. R.↗

A Brief Summary of Some of the Laboratory Astrophysics Workshop

Our present knowledge of the molecular universe has come primarily from radio observations [ I include here millimeter and submillimeter in this rubric]. There are a number of reasons for this but the primary one is the extremely high spectral resolution. The ease of observing emission from the volume of dense molecular clouds without significant attenuation by scattering from dust has shown this to be the powerful observational tool for molecular astronomy. Finally the relative simplicity of rotational compared to vibrational or electronic spectroscopy allows carrier identification as well as facile evaluation of cloud conditions such as density and temperature. These virtues become tenuous as the astronomical observations are pushed to higher frequencies for enhanced observational sensitivity. Thus precision rest frequencies are mandatory for the search for new species. We may inquire about which new species require particular attention, and which species may be relatively safely predicted on the basis of lower frequency laboratory measurements. For a rigid rotor the three rotational constants are sufficient to completely specify the transition frequencies. The intensities require the three components of the electric dipole moment. For semirigid species, where the centrifugal distortion, may be treated at the quartic level of angular momentum (Bunker et al. 1998), up to five additional constants are required (Watson 1967). There are a number of such species of considerable interest, where laboratory measurements are adequate for astronomical searches.

Klemperer, William↗

Nonintrusive Temperature and Velocity Measurements in a Hypersonic Nozzle Flow

Distributions of nitric oxide vibrational temperature, rotational temperature and velocity have been measured in the hypersonic freestream at the exit of a conical nozzle, using planar laser-induced fluorescence. Particular attention has been devoted to reducing the major sources of systematic error that can affect fluorescence tempera- ture measurements, including beam attenuation, transition saturation effects, laser mode fluctuations and transition choice. Visualization experiments have been performed to improve the uniformity of the nozzle flow. Comparisons of measured quantities with a simple one-dimensional computation are made, showing good agreement between measurements and theory given the uncertainty of the nozzle reservoir conditions and the vibrational relaxation rate.

OByrne, S.↗

Active suspensions for vibration isolation

The concept of mechanical impedances is used to analyze constraints on a single-link vibration isolation suspension. In particular, an assessment is made of the effects of the limited feedback bandwidth on the achievable suspension impedance and corresponding limits of attenuation of the transmitted force using Bode integral constraints and Blackman's formula. The performance of a piezoelectric strut is evaluated as an example.

Lurie, B. J.↗

Recent Improvements to the Acoustical Testing Laboratory at the NASA Glenn Research Center

The Acoustical Testing Laboratory (ATL) consists of a 27- by 23- by 20-ft (height) convertible hemi/anechoic chamber and separate sound-attenuating test support enclosure. Absorptive fiberglass wedges in the test chamber provide an anechoic environment down to 100 Hz. A spring-isolated floor system affords vibration isolation above 3 Hz. These specifications, along with very low design background levels, enable the acquisition of accurate and repeatable acoustical measurements on test articles that produce very low sound pressures. Removable floor wedges allow the test chamber to operate in either a hemi-anechoic or anechoic configuration, depending on the size of the test article and the specific test being conducted. The test support enclosure functions as a control room during normal operations. Recently improvements were accomplished in support of continued usage of the ATL by NASA programs including an analysis of the ultra-sonic characteristics. A 3-D traverse system inside the chamber was utilized for acquiring acoustic data for these tests. The traverse system drives a linear array of 13, 1/4 in.-microphones spaced 3 in. apart (36 in. span). An updated data acquisition system was also incorporated into the facility.

Podboy, Devin M.↗