Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-Voltage Phosphate Cathodes for Rechargeable Ca-Ion Batteries

Calcium-ion batteries (CIBs) are under investigation as next-generation energy storage devices due to their theoretically high operating potentials and lower costs tied to the high natural abundance of calcium. However, the development of CIBs has been limited by the lack of available positive electrode materials. In this study, for the first time, we report two functional polyanionic phosphate materials as high-voltage cathodes for CIBs at room temperature. NaV 2 (PO 4 ) 3 electrodes were found to reversibly intercalate 0.6 mol of Ca 2+ (81 mA h g –1 ) near 3.2 V (vs Ca 2+ /Ca) with stable cycling performance at a current density of 3.5 mA g –1 . The olivine framework material FePO 4 reversibly intercalates 0.2 mol of Ca 2+ (72 mA h g –1 ) near 2.9 V (vs Ca 2+ /Ca) at a current density of 7.5 mA g –1 in the first cycle. Structural, electronic, and compositional changes are consistent with reversible Ca 2+ intercalation into these two materials.

25 ENERGY STORAGE↗

Chiral Electrokinetic Phenomena in Single Nanopores

Abstract The arrangement of solvent molecules and ions at solid–liquid interfaces determines electrochemical properties that are important in separations platforms, sensing technologies, and energy‐storage systems. Here we show that single glass and polymer pores in contact with propylene carbonate (PC) solutions of LiClO 4 exhibit an effective surface potential that is modulated by the enantiomeric excess of the solvent. In particular, electrochemical and electrokinetic measurements of ionic transport through glass pipettes and polymer pores reveal that the effective surface potential is significantly lower in solutions prepared using enantiomerically pure PC than in solutions prepared using racemic PC. Both pore systems became positively charged in all racemic solutions examined in the range of LiClO 4 concentrations between 1 mM and 100 mM, whereas solutions in ( R )‐(+)‐PC induced a positive surface potential only at concentrations above ~5 mM. The effective surface potential is quantified through asymmetry in current–voltage curves and zeta‐potential measurements. Vibrational sum‐frequency‐generation experiments on LiClO 4 solutions in racemic and enantiomerically pure PC indicate that the surface lipid‐bilayer‐like region in the former is more strongly organized than in the latter, dictating the favorable positions for lithium and perchlorate ions in each case. The more ordered molecular packing in the racemic liquid leads to accumulation of lithium ions on the outside of the bilayer, creating a higher effective positive charge. Our results highlight the extreme sensitivity of the interfacial potential on molecular organization of the solvent, and the relatively unexplored role that chirality can play in electrokinetic phenomena.

Alanis, Kristen↗

High voltage window electrolyte for supercapacitors

A supercapacitor according to the present invention includes a negative carbon-comprising electrode which does not intercalate sodium, and a positive carbon-comprising electrode. An electrolyte composition comprises sodium hexafluorophosphate and a non-aqueous solvent comprising at least one selected from the group consisting of ethylene glycol dimethyl ether, diethylene glycol dimethyl ether, triethylene glycol dimethyl ether, and tetraethylene glycol dimethyl ether. The supercapacitor has an electrochemical voltage window of from +0.0 V to 3.5 V (full cell voltage). The electrolyte has an electrochemical voltage window of from +0.05 V to 3.9 V vs. Na/Na+. A method of making and a method of operating a supercapacitor is also disclosed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High voltage window electrolyte for supercapacitors

A supercapacitor according to the present invention includes a negative carbon-comprising electrode which does not intercalate sodium, and a positive carbon-comprising electrode. An electrolyte composition comprises sodium hexafluorophosphate and a non-aqueous solvent comprising at least one selected from the group consisting of ethylene glycol dimethyl ether, diethylene glycol dimethyl ether, triethylene glycol dimethyl ether, and tetraethylene glycol dimethyl ether. The supercapacitor has an electrochemical voltage window of from +0.0 V to 3.5 V (full cell voltage). The electrolyte has an electrochemical voltage window of from +0.05 V to 3.9 V vs. Na/Na+. A method of making and a method of operating a supercapacitor is also disclosed.

25 ENERGY STORAGE↗

Field Testing of PID-p Susceptible Bifacial PERC Modules: Impact of Light, Voltage and Module History ​

This work investigates the potential induced degradation-polarization (PID-p) of bifacial passivated emitter and rear contact (PERC) modules installed in the field at the Florida Solar Energy Center. 22 modules were stressed over 1 year under various voltage (-1500V, -3500, +1500V) and mounting configurations (close to ground, 2 meters from ground, close to roof). The positively stressed modules were anticipated to have experiences PID-p on their front side. However, no degradation was observed, as the light-induced recovery effect effectively counteracted the degradation. The negatively stressed modules experienced Pmax drops during 2 weeks before stabilizing at 5-6% loss. I-V and EL characteristics suggest a PID-p degradation on the rear side. Lower degradation rates are observed with lower voltage and when the mounting configuration allows more albedo light on the rear side to compensate for the degradation. PID-p is observed to stabilize at similar level for the voltage and mounting configuration tested with slightly lower Pmax in winter. EL imaging reveals that cells are not degrading at the same rate across a module. Some cells get darker and then brighter which corresponds to the silicon/passivation interface going through depletion and then inversion when enough positive charges are accumulated. After full light-recovery, the modules were tested again along with 22 brand-new ones to assess the impact of the module history. Results confirmed the trends observed in the first year with PID-p occurring at voltage as low as -600V and recovered modules degrading faster than brand-new ones.

14 SOLAR ENERGY↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗

Influence of Light Atoms on Quantification of Atomic Column Positions in Distorted Perovskites with HAADF-STEM

Measurement of picometer-scale atomic displacements by aberration-corrected STEM has become invaluable in the study of crystalline materials, where it can elucidate ordering mechanisms and local heterogeneities. HAADF-STEM imaging, often used for such measurements due to its atomic number contrast, is generally considered insensitive to light atoms such as oxygen. Light atoms, however, still affect the propagation of the electron beam in the sample and, therefore, the collected signal. In this work, we demonstrate experimentally and through simulations that cation sites in distorted perovskites can appear to be displaced by several picometers from their true positions in shared cation-anion columns. The effect can be decreased through careful choice of sample thickness and beam voltage or can be entirely avoided if the experiment allows reorientation of the crystal along a more favorable zone axis. Therefore, it is crucial to consider the possible effects of light atoms and crystal symmetry and orientation when measuring atomic positions.

36 MATERIALS SCIENCE↗

MAGNETICALLY SUSPENDED CANNED ROTOR PUMPS FOR THE INTEGRAL MOLTEN SALT REACTOR

This project developed a molten salt pump design for small modular reactors, concentrated solar, and Gen IV nuclear reactors with a magnetically levitated rotor that can operate at temperatures of up to 700 °C. This eliminates the need for rotating seals and roller element bearings which require maintenance and are prone to failure. The pump design is also more compact than existing molten salt pump designs which require long shafts to thermally isolate the electric motor. The aims of the project are to: 1) design and test the molten salt pump, 2) develop and test a high temperature position sensor needed for magnetic bearing control, and 3) develop and test high temperature coil fabrication methods for electric motor and magnetic bearing fabrication. To develop the high temperature coils, conductor materials were analyzed for oxidation, diffusion, cladding, and resistivity. Of the candidate conductor materials that met the requirements, silver was chosen. The long-term impact of radiation on silver resistivity was analyzed by developing a model of a generic molten salt fast reactor to model the conductor irradiation in worst case scenarios. The analysis showed that increased resistivity due to transmutation of silver decreases exponentially with the reactor reflector thickness. Different electrical insulation materials were tested and the final high temperature coils developed were able to withstand conductor to ground voltages up to 1800 V before insulation breakdown. Magnetic bearings require high-precision high-speed measurements of the rotor position to operate. Current commercial position sensors can only operate up to 550 °C so a novel position sensor was developed that can operate up to 800 °C. These sensors were also designed to measure the position of the metallic rotor through a thin metallic corrosion barrier that protects that coils, insulation, and magnetic cores so that the salt containment barrier does not have any penetrations. The high-temperature sensor was tested and had comparable performance to commercially available inductive position sensors. The sensor design and signal processing has led to several invention disclosures. The magnetically levitated molten salt pump design was completed and analyzed. The chloride salt test loop at Oak Ridge National Laboratory was chosen to test the pump and the pump hydraulics and power were designed for the test loop flow and pressure requirements. Classes of motor designs that do not utilize permanent magnetic were considered for the high-temperature motor. After extensive analysis of their performance, a synchronous reluctance motor was chosen for the pump. The design was refined and analyzed to optimize performance. The magnetic bearings were designed to meet the force and frequency requirements necessary to levitate the rotor and reject disturbances from rotor imbalance, motor forces, and hydraulic forces. Compliant mounts for the position sensors were designed that would not damage the ceramic sensor components and maintain sensor alignment over a wide temperature range. A thermal hydraulic analysis of the molten salt coolant flow used to cool the rotor and stator was performed to ensure that the maximum temperature in the rotor and stator will not exceed 725 °C. The corrosion barrier and casing were designed to maintain the salt fluid boundary by using compliant features to absorb large expansion mismatches due to different coefficients of thermal expansion (CTE). Finally, the salt drain and fill systems were designed along with the pump support structure, integration with the test loop, and thermal insulation and heating. Corrosion barrier fabrication experiments were performed to assess using laser cladding to apply a sub-millimeter corrosion barrier to the surface of a Fe-Co-V magnetic core material. The cladding method showed minimal mixing between materials at their interface and withstood temperature cycling without damage to the cladding. The technology commercialization is focused on the high-temperature position sensors and there has been significant interest from the nuclear industry in utilizing these sensors along with some interest from the aerospace industry. The project also led to a research collaboration with a fusion energy industrial partner to study barriers to scaling the pump design from the kW size to the MW size. This research collaboration will also study methods to create high-temperature coils that have conductor to ground breakdown voltages above 5 kV. The successful development of high-temperature electromagnetic coils and high-temperature position sensors greatly increases the temperature limits for electromagnetic devices that don’t rely on permanent magnets. This includes electric motors, magnetic bearings, linear actuators, rotary position and velocity sensing, actuated valves, and generators to name a few. This will fill a current need in molten salt reactors, concentrated solar, and fusion energy for these critical peripheral devices needed for practical reactor designs that do not currently have commercial solutions.

Hines, J Wesley↗

Temperature dependence of resistivity of carbon micro/nanostructures: Microscale spatial distribution with mixed metallic and semiconductive behaviors

The temperature coefficient of resistivity (θ T ) of carbon-based materials is a critical property that directly determines their electrical response upon thermal impulses. It could have metal- (positive) or semiconductor-like (negative) behavior, depending on the combined temperature dependence of electron density and electron scattering. Its distribution in space is very difficult to measure and is rarely studied. Here, for the first time, we report that carbon-based micro/nanoscale structures have a strong non-uniform spatial distribution of θ T . This distribution is probed by measuring the transient electro-thermal response of the material under extremely localized step laser heating and scanning, which magnifies the local θ T effect in the measured transient voltage evolution. For carbon microfibers (CMFs), after electrical current annealing, θ T varies from negative to positive from the sample end to the center with a magnitude change of >130% over <1 mm. This θ T sign change is confirmed by directly testing smaller segments from different regions of an annealed CMF. For micro-thick carbon nanotube bundles, θ T is found to have a relative change of >125% within a length of ~2 mm, uncovering strong metallic to semiconductive behavior change in space. In conclusion, our θ T scanning technique can be readily extended to nm-thick samples with μm scanning resolution to explore the distribution of θ T and provide a deep insight into the local electron conduction.

36 MATERIALS SCIENCE↗

Impact of Electrolyte Additives on the Lifetime of High Voltage NMC Lithium-Ion Pouch Cells

This work involves improving the lifetime of lithium-ion cells during high voltage cycling using electrolyte additives. Three generations of electrolyte additives were investigated and screened in NMC442/graphite pouch cells using a 24 h voltage-hold protocol at 40 degrees C to accelerate oxidative reactions occurring at 4.4 V. Once promising additives and combinations were identified, they were then tested in cobalt-free NMC640/graphite cells for long-term cycling to upper cutoff voltages of 4.3, 4.4, and 4.5 V at temperatures of 20, 40, and 55 degrees C. Degradation mechanisms were probed using dV/dQ analysis, micro-X-ray fluorescence spectroscopy, and electrochemical impedance spectroscopy. The primary failure mode of cells held at high voltages is due to increase in cell impedance, which is correlated to the dissolution of transition metals, specifically manganese, originating from the positive electrode. We believe this dissolution is presumably due to the formation of a high impedance rock salt surface layer on the NMC positive electrode particles. Such deleterious outcomes can be limited by selecting an appropriate electrolyte additive package. It is hoped that this paper can provide a starting point for developing NMC Li-ion cells that can operate to voltages as high as 4.4 V and still display long lifetimes.

Azam, Saad↗

Ambipolar Electrochemistry of Pre‐Intercalated Ti 3 C 2 T x MXene in Ionic Liquid Electrolyte

Abstract Cation intercalation with or without redox remains the dominant charge storage mechanism for two‐dimensional (2D) Ti 3 C 2 T x MXene. Anion‐based charge storage remains unexplored due to intrinsic negative surface charge of MXenes preventing spontaneous intercalation of anions and irreversible oxidation of Ti at anodic potentials in aqueous electrolytes. In this work, we report on the ambipolar electrochemical behavior of the Ti 3 C 2 T x in ionic liquid electrolyte over a 2.5 V electrochemically stable window. The experiments are conducted on a thin Ti 3 C 2 T x film current collector coated with an electroactive layer of small flakes (∼150 nm) of Ti 3 C 2 T x pre‐intercalated with 1‐ethyl‐3‐methylimidazolium bis‐(trifluoromethylsulfonyl)‐imide (EMIM‐TFSI) ionic liquid. Couples of redox peaks with a very small potential separation during the voltage sweep are observed at high negative (−0.75 V vs. Ag wire) and high positive (+0.75 V vs. Ag wire) potentials. Our experimental electrochemical data combined with density functional theory (DFT) calculations suggest feasibility of pseudo‐intercalation of TFSI anions between Ti 3 C 2 T x flakes. This study provides a pathway for elucidating anion intercalation for different MXene chemistries in solvent‐free electrolytes, which can lead to development of MXene based energy storage devices with improved performance.

Electrochemistry↗

Electrochemical and In Situ Spectroscopic Study of the Effect of Prussian Blue as a Mediator in a Solid-State Supercapacitor

In situ X-ray absorption spectroscopy (XAS) along with electrochemical measurements were used to explore the redox activity of Prussian blue (PB) and its contribution to pseudocapacitance in an asymmetrical solid-state supercapacitor (SC). The SC, with a configuration of (activated carbon)/polymer electrolyte membrane/(activated carbon + PB), was fabricated with an embedded KCl saturated Ag/AgCl reference electrode. The potentials of the two electrodes were generally displaced proportionally with increase in the cell voltage. Upon negative polarization from the open circuit voltage (OCV) condition to -3 V, the charge capacity was greater than that upon positive polarization from the OCV condition to +3 V, in agreement with the higher fraction of Fe(III) than that of Fe(II) and the low concentration of K ions in PB. Detailed analysis of cyclic voltammetry data in the range between 0 and -3 V indicates that the battery-like contribution to the charge current was 96% that of the capacitor-like contribution at a scanning rate of 2.5 mV s -1 but only 15% at 100 mV s -1 . The in situ XAS characterization results indicate that the majority of Fe was reversibly charged and discharged between Fe(III) and Fe(II) during positive and negative polarizations with minimal changes in local atomic structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems

Silicon photomultipliers (SiPMs) offer advantages such as lower relative cost, smaller size, and lower operating voltages compared to photomultiplier tubes. A SiPM’s readout circuit topology can significantly affect the characteristics of an imaging array. In nuclear imaging and detection, energy, timing, and position are the primary characteristics of interest. Nuclear imaging has applications in the medical, astronomy, and high energy physics fields, making SiPMs an active research area. This work is focused on the circuit topologies required for nuclear imaging. We surveyed the readout strategies including the front end preamplification topology choices of transimpedance amplifier, charge amplifier, and voltage amplifier. In addition, a review of circuit topologies suitable for energy, timing, and position information extraction was performed along with a summary of performance limitations and current challenges.

42 ENGINEERING↗

Apparatus and methods of detecting transient discharge modes and/or closed loop control of pulsed systems and method employing same

A system and method for differentiating between different modes of pulsed electrical discharges via of an amplitude to time (ATC) conversion circuit is described. A bipolar ATC circuit is used to add together the positive and negative portions of an attenuated and filtered signal derived either from the voltage or current of a pulse. Alternatively, a unipolar ATC circuit may be employed. The resulting processed signal is compared against a reference voltage to generate an output signal that is active for the amount of time that the processed signal exceeds the reference voltage. Discharge mode is determined based on three factors: did a pulse occur, if a pulse occurred when did the pulse start relative to the original pulse event, and what is the duty cycle of the pulse. Subsequent pulse generated may be controlled accordingly.

Fitzpatrick, Joseph F.↗

Transition from retrograde to prograde drift instabilities in a magnetron microdischarge

Rotating plasma structures, or “spokes,” in magnetized discharges characterized by perpendicular electric and magnetic fields have been seen in a growing number of studies and are believed to be the result of gradient-driven drift instabilities. Under certain conditions, we have shown the spoke’s rotation to be opposite to the E B direction, i.e., retrograde in its expected direction. Recently, we have linked such counter-intuitive rotation to a local inversion of the electric field. Here, we give further experimental evidence for this inversion and attempt to provide an explanation for a relatively distinct transition seen between retrograde and positive (prograde) drift. In the experiments, a partially magnetized plasma forms inside a magnetron device of mm radius operated with argon. Discharge current–voltage measurements are acquired for a range of argon fill pressure and inter-electrode spacing. We find two branches of operation—a low current branch of negative resistance, coinciding with the retrograde spoke rotation, and a higher current branch of positive resistance, coincident with prograde spoke rotation. We postulate that at low discharge currents, high magnetic field confinement leads to a large density gradient, causing more electron transport to the anode than that demanded by the external circuit. At higher currents, anomalous axial electron transport (across the magnetic field lines) becomes dominant, eliminating the conditions for field inversion. Here, the current thresholds for the field inversion are found to be sensitive to the argon pressure and inter-electrode spacing.

42 ENGINEERING↗

A method to observe field-region oxide charge and inter-electrode isolation from CV-characteristics of n-on-p devices

Abstract N-on-psilicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditionalp-on-nsensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO 2 -passivatedn-on-psensors is the generation of an inversion layer under the Si/SiO 2 -interface by a positive interface-oxide-charge (N ox ) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolnts (p-stp,p-spray) between n + -electrodes. Focusing on the guard-ring regions ofn-on-psensors where no isolation implants are applied between the electrodes, a capacitance-voltage (CV) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage (V th,iso ) in theCV-characteristics of a biased n + -electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measuredV th,iso was found to contain information on the field-regionN ox and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiatedn-on-psensors, the results indicate that position sensitiven-on-psensors without isolation implants may be feasible in future HEP experiments.

Instruments & Instrumentation↗

High voltage, cross-field, gas switch and method of operation

A high voltage gas switch includes a gas-tight housing containing an ionizable gas at a preselected gas pressure. The gas switch includes a gas-tight housing containing an ionizable gas at a gas pressure selected based upon a Paschen curve for the ionizable gas, where the Paschen curve plots breakdown voltages of the ionizable gas as a function of gas pressure multiplied by grid-to-anode distance, and where values of gas pressure multiplied by grid-to-anode distance increase over at least a portion of the Paschen curve in conjunction with increasing breakdown voltages. The gas switch also includes an anode disposed within the gas-tight housing, a cathode disposed within the gas-tight housing, and a control grid positioned between the anode and the cathode, where the control grid is spaced apart from the anode by a grid-to-anode distance selected based upon a desired operating voltage.

42 ENGINEERING↗

Structural basis for severe pain caused by mutations in the S4-S5 linkers of voltage-gated sodium channel Na V 1.7

Gain-of-function mutations in voltage-gated sodium channel Na V 1.7 cause severe inherited pain syndromes, including inherited erythromelalgia (IEM). The structural basis of these disease mutations, however, remains elusive. Here, we focused on three mutations that all substitute threonine residues in the alpha-helical S4-S5 intracellular linker that connects the voltage sensor to the pore: Na V 1.7/I234T, Na V 1.7/I848T, and Na V 1.7/S241T in order of their positions in the amino acid sequence within the S4-S5 linkers. Introduction of these IEM mutations into the ancestral bacterial sodium channel Na V Ab recapitulated the pathogenic gain-of-function of these mutants by inducing a negative shift in the voltage dependence of activation and slowing the kinetics of inactivation. Remarkably, our structural analysis reveals a common mechanism of action among the three mutations, in which the mutant threonine residues create new hydrogen bonds between the S4-S5 linker and the pore-lining S5 or S6 segment in the pore module. Because the S4-S5 linkers couple voltage sensor movements to pore opening, these newly formed hydrogen bonds would stabilize the activated state substantially and thereby promote the 8 to 18 mV negative shift in the voltage dependence of activation that is characteristic of the Na V 1.7 IEM mutants. Our results provide key structural insights into how IEM mutations in the S4-S5 linkers may cause hyperexcitability of Na V 1.7 and lead to severe pain in this debilitating disease.

60 APPLIED LIFE SCIENCES↗