Search NASASearch

SEARCH · Search NASA

Results for “WASTE STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

377 records · Page 8

Oxidation Chemistry of Bicarbonate and Peroxybicarbonate: Implications for Carbonate Management in Energy Storage

Carbonate formation presents a major challenge to energy storage applications based on low-temperature CO 2 electrolysis and recyclable metal–air batteries. While direct electrochemical oxidation of (bi)carbonate represents a straightforward route for carbonate management, knowledge of the feasibility and mechanisms of direct oxidation is presently lacking. Herein, we report the isolation and characterization of the bis(triphenylphosphine)iminium salts of bicarbonate and peroxybicarbonate, thus enabling the examination of their oxidation chemistry. Infrared spectroelectrochemistry combined with time-resolved infrared spectroscopy reveals that the photoinduced oxidation of HCO 3 – by an Ir(III) photoreagent results in the generation of the short-lived bicarbonate radical in less than 50 ns. The highly acidic bicarbonate radical undergoes proton transfer with HCO 3 – to furnish the carbonate radical anion and H 2 CO 3 , leading to the eventual release of CO 2 and H 2 O, thus accounting for the appearance of H 2 O and CO 2 in both electrochemical and photochemical oxidation experiments. Here, the back reaction of the carbonate radical subsequently oxidizes the Ir(II) photoreagent, leading to carbonate. In the absence of this back reaction, dimerization of the carbonate radical provides entry into peroxybicarbonate, which we show undergoes facile oxidation to O 2 and CO 2 . Together, the results reported identify tangible pathways for the design of catalysts for the management of carbonate in energy storage applications.

25 ENERGY STORAGE

Evaluation of Long-Term Storage Stability and Operational Efficiency of Rapid Cycle Amine Adsorbents

With the recent incorporation of Mars Extravehicular Activity (EVA) into the 2025 NASA roadmap, Rapid Cycle Amine (RCA) technology advancement within the Exploration Extravehicular Mobility Unit (xEMU) applies to both the upcoming Lunar Artemis missions and future human exploration of Mars. The incorporation of commercial spacesuit vendors to service NASA’s crewed-space programs since 2021 has increased the demand for regenerable, RCA-based carbon dioxide (CO2) and humidity control adsorbents. The regenerable RCA subunit is the most advanced, long-term solution for CO2 removal and humidity control, enabling both lunar and Martian EVAs. The adsorbent selected for use within the RCA unit must exhibit sufficient storage stability and operational efficiency for prolonged missions. As XploSafe worked to simultaneously develop both a recirculating sub-atmospheric test rig and adsorbents for the RCA system within the xEMU, several novel adsorbents were evaluated for long-term storage stability in support of future extended-duration missions. The chosen materials were periodically evaluated by nuclear magnetic resonance (NMR) spectroscopy, thermal desorption-coupled with gas chromatography/mass spectrometry (TD-GC/MS), and CO2 adsorption to assess long-term storage efficacy across various environmental storage conditions. NMR spectroscopy was utilized by extracting the active CO2 adsorbing chemical from the solid support with deuterated solvent and comparing the spectra over time for degradation and change. The solid adsorbents were also analyzed via TD-GC/MS to reveal any potential off-gassing chemicals over time. Additionally, XploSafe’s breakthrough test rig was utilized to dose the solid adsorbents with a 585 BTU/h metabolic rate flow-equivalent CO2 stream and monitored for 0–99% CO2 breakthrough. The performance metrics from the breakthrough analysis were compared over the storage study duration for CO2 removal and humidity control. Xplo-SA9T was evaluated for 24 months, whereas two additional adsorbent variants, MMPA-Sorbent and LPEI-Sorbent, were each evaluated for 12 months.

John R Tidwell

Jumpstart Opportunities to Unleash Leadership in Energy Storage (JOULES)

Current-generation Li-ion batteries with cobalt- and nickel-containing cathodes and graphite anodes are approaching performance and cost limits. In this program, 24M Technologies, Inc. (24M) is teaming with the Massachusetts Institute of Technology (MIT) and University of Michigan (UM) to develop low cost and fast charging sodium metal batteries with good low-temperature performance and high energy density, building upon previous work performed under ARPA-E programs. Key achievements include optimization of solid electrolyte and anode current collector, optimized cathode active materials, development of high-performance electrolyte formulations, and integration of these components into full cells. The cell design incorporates (1) an ultra-thick cathode (>9 mAh/cm 2 ) comprising advanced cobalt-free, sodium cathode active material, (2) advanced fast-charging electrolyte (up to 12 mS/cm) developed using machine learning and automated high-throughput screening technology by UM, and (3) ceramic modified separator that enable smooth Na transport and deposition, developed at MIT, enabling a high-energy density anode-free configuration and maximizing the energy density of sodium batteries. The team has successfully combined these approaches to sodium chemistry and paved the way to meeting the fast-charging, high-energy density, and low-cost requirements of next-generation drone, electric vertical take-off and -landing, and electric vehicle batteries. Performance for anode-free sodium cells developed under this program is more powerful than the commercial Li-ion batteries. The final deliverable cell design has achieved over 300 Wh/kg and volumetric energy density above 800 Wh/L (Table 1). Additionally, the team has achieved over (1) a lifetime of 340 cycles, (2) 80% capacity retention at -20 °C (compared 25 °C), and (3) the ability to fast charge to 80% SOC in 20 minutes.

25 ENERGY STORAGE

Nuclear Safety [Vol. 29, No. 3, July-September 1988]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 259 Fifteenth Water Reactor Safety Information Meeting by E. G. Silver; CONTROL AND INSTRUMENTATION: 284 Reliability Technology to Improve and/or Maintain Emergency Diesel Generator Performance by S. Karimian and J. H. Taylor, 293 A Noise Diagnostics System for Operator Advice by G. Hessel, P. Liewers, P. Schumann, W. Schmitt, and F.-P. Weiss; PLANT SAFETY FEATURES: 307 A Passive Containment System for Advanced Light-Water Reactors by O. B. Falls, Jr., and F. W. Kleimola; ENVIRONMENTAL EFFECTS: 318 Data Base Construction for a Computerized Radiological Risk Investigation System by L. M. Hively, J. E. Nyquist, J. L. Bledsoe, and A. L. Sjoreen, 326 Erratum to "Radiation Hormesis and Nuclear Safety," Vol. 29, No. 1; OPERATING EXPERIENCES: 327 Operational Safety Experience and Passive Safety Testing at the Fast Flux Text Facility by Q. L. Baird, J. L. Rathbun, D. D. Stepnewski, R. L. Stover, and A. E. Waltar, 344 Backfilling of Independent Residual Heat Removal Systems in West Germany and Switzerland by G. Eckert and Y. Salomon, 353 Reactor Shutdown Experience Compiled by J. W. Cletcher, 356 Selected Safety-Related Events Compiled by G. A. Murphy, 363 Operating U.S. Power Reactors Compiled by E. G. Silver; RECENT DEVELOPMENTS: 384 General Administrative Activities Compiled by E. G. Silver, 390 Reports, Standards, and Safety Guides by D. S. Queener, 395 Status of Power-Reactor Projects Undergoing Licensing Review Compiled by E. G. Silver, 400 Proposed Rule Changes as of Mar. 31,1988; ANNOUNCEMENTS: 283 International ENS/ANS Conference on Thermal Reactor Safety "NUCSAFE 88", 317 Northwestern University Short Course on Radiation Safety, 407 Second International Seminar on Small- and Medium-Sized Nuclear Reactors, 407 International Workshop on New Developments in Occupational Dose Control and ALARA Implementation at Nuclear Power Plants and Similar Facilities, 408 Fourth International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-4), 404 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)

Robust and tunable oxide nanoscrolls for solar-driven H 2 generation and storage

Hydrogen gas is a promising alternative to fossil fuels due to its high energy output and environmentally safe byproducts. Various morphologies of photocatalytic materials have been explored for high-efficiency H 2 production, for instance, quasi-1D nanoscroll structures that provide a larger surface-to-volume ratio. Recently, we predicted layer-by-layer formation of stable oxide nanoscrolls directly from dichalcogenide precursors, eliminating the need for costly formation of two-dimensional oxides for a roll-up synthesis of nanoscrolls. Here, in this study, we evaluate the suitability of those oxide nanoscroll materials—MoO 3 , WO 3 , PdO 2 , HfO 2 , and GeO 2 —for solar-driven photocatalytic H 2 production and storage. Using excited state theory coupled with Bethe–Salpeter equation simulations, we discern their electronic and optical properties as a function of interlayer scroll spacing and find them to be highly conducive for solar-driven photocatalysis. Additionally, using ab initio molecular dynamics simulations, we show that they are also suitable for H 2 storage as the nanoscrolls exhibit an effective trapping of hydrogen, even in the presence of defects and vacancies in the oxides. This work thus demonstrates the discovery of robust and tunable oxide nanoscrolls as materials for advancing solar-driven hydrogen technologies.

Chemical compounds

Assessing the Adhesion of Nanofibrous PVDF-HFP as Passive Thermal Control Coatings for the Extraterrestrial Storage of Cryogenic Propellants

Cryogenic propellant passive thermal management techniques in space are essential complements to active thermal management methods, helping reduce absolute dependence on the latter. Particularly, materials with superior optical properties (high solar reflectance and infrared emittance) would be beneficial for passive thermal control to reject most of the incident solar radiation and enhance thermal emission from the storage tank, leading to self-cooling. We developed a nanofibrous, porous passive thermal control material by electrospinning polyvinylidene fluoride-co-hexafluoropropylene (PVDF-HFP) co-polymer onto an aluminum foil substrate. The material exhibits a very high solar reflectance (>99%) and infrared emittance (~86%) when characterized in the ultraviolet-visible-near infrared and mid-infrared wavelengths. This study focuses on the adhesion of the nanofibrous PVDF-HFP to the substrate. We incorporated in-lab fabricated and commercial adhesives, under normal room conditions, between the nanofibers and the aluminum foil substrate to improve their adhesion. Some samples were also exposed to space-like conditions – vacuum and thermal cycling, to investigate their effects on the strengths of adhesives. Subsequently, adhesion peel tests were conducted on all the samples to assess the peel strengths of the bonds. Peel test strengths after space environment conditioning of the adhesives were generally higher than those observed in the pristine, unaged samples. The results are discussed in this study.

Chieloka Ibekwe

Cation-Diffusive Carbon Interlayers Stabilize Na Metal and Double the Current in Na-S Redox-Flow Batteries for Grid-Scale Energy Storage

The sodium-sulfur nonaqueous redox-flow batteries (Na-S NARFBs) using earth-abundant elements are highly attractive due to the low material cost and improved energy density for grid-scale energy storage. However, the low current performance, poor Na0/Na+ redox kinetics, and Na dendrite growth pose severe challenges. We introduce cation-diffusive layers (CDLs): thin and Na+ affinitive interlayers at the Na anode that direct Na+ transport and stabilize Na deposition. Benchmarking three archetypal materials—carbon paper (CP), glass microfiber paper (GF), and foam—across Na-Na and Na-Cu, and Na-S cells identifies CP as the optimum. CP reduces symmetric cell overpotential by more than 70%, achieves 98% Na plating-stripping efficiency, and doubles the Na-S cell current density from 0.5 to 1.0 mA cm−2 without sacrificing capacity or efficiency. Ex situ electrochemical and SEM/XPS analysis, combined with molecular dynamics (MD) studies, reveal that electron-rich carbon fibers disperse supporting salt aggregates, enrich near-surface Na+ density, and create ion transport pathways for fast Na0/Na+ exchange while mitigating membrane degradation. Because of the ion-centric mechanism, CDLs can be generalized to other metal-anode designs. Further, this work establishes CDL design rules—cationic affinity and appropriate micro/nanostructure—as a simple, scalable route to high-current, durable metal-anode flow batteries.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Effect of Oxidizing Impurities on the Corrosion Behavior of Structural Alloys Exposed to MgCl 2 Molten Salt Vapor

The corrosion behavior of structural alloys SS304 and IN617 when exposed to vapors of MgCl 2 molten salt at 764 °C for 100 h in an argon atmosphere was investigated as a function of the level of oxidizing impurities (e.g., NaOH) present in the salt. Increasing the concentration of oxidizing impurities in the salt caused an increase in corrosion in both structural alloys, as measured by Cr depletion layers. A poorly adhered oxide scale layer containing Mg, Al, and Cr was observed on the surface of the metals, and local attack was observed as well. The Ni-based IN617 showed lower Cr depletion and less scale formation than the Fe-based SS304. These results demonstrate that oxidizing impurities in the molten salt will impact the vapor phase corrosion for structural members exposed to the molten salt headspace. This finding is highly relevant for understanding the effects of the vapor phase in molten salt applications, including molten salt thermal energy storage, molten salt nuclear reactors, and molten salt electrochemistry.

25 ENERGY STORAGE

Advanced-Research-on-Integrated-Energy-Systems-Based Analysis to Support Resilient System Upgrades: Energy to Communities Energyshed In-Depth Partnership with Molokai, Hawaii

The Molokai, Hawaii, Energy to Communities (E2C) Energyshed project represents a collaborative effort between the National Laboratory of the Rockies, Shake Energy Collaborative, the Molokai Clean Energy Hui, Sustainable Molokai, and Ho'ahu Energy Cooperative Molokai to advance Molokai's Community Energy Resilience Action Plan (CERAP). Supported by Hawaiian Electric Company and the Hawaii State Energy Office, the initiative aims to develop a community-defined portfolio of renewable energy solutions that enhance energy resilience while aligning with the Hawaiian Electric Integrated Grid Plan (IGP) and Molokai's energy goals. Phase 1 focused on technical analyses and community engagement to co-design feasible energy scenarios. Challenges such as grid upgrades, storage sizing, and inverter ride-through standards were addressed to align technical and operational requirements with community preferences. The project equips Molokai with actionable data and insights to implement energy initiatives while ensuring resilient and culturally informed solutions. Future efforts aim to finalize project designs, secure interconnection agreements, and deploy energy projects that reflect community priorities and technical feasibility.

24 POWER TRANSMISSION AND DISTRIBUTION

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]

Commercial and Industrial Energy Procurement in Nigeria: A Consumer's Guidebook

Across Africa, countries have incorporated a variety of new energy sources into their energy mix to account for increasing demand. In Nigeria, electricity consumption per capita has grown nearly 50% in the past 20 years. To address rising demand for energy in Nigeria, the country has passed several recent policies and regulations aimed at increasing energy generation across the country, improving the country's transmission infrastructure, and ensuring that electricity reliably reaches end users, including commercial and industrial (C&I) customers. This guidebook is designed for C&I customers in Nigeria to use in the consideration of procuring such onsite, captive energy systems to supplement their energy needs. Each section of this guidebook touches on a step of the procurement process and details the relevant stakeholders, processes, and data needed to make decisions during that step.

14 SOLAR ENERGY

Elimination of detrimental grain boundary segregation in garnets

Garnet Li 7 La 3 Zr 2 O 12 electrolyte is considered a key enabler of solid-state batteries with Li metal electrodes, but the grain boundaries impair its performance. To date, the understanding of grain boundary structures and its impact on performance remains elusive. Here, we show that element segregation at Li 7 La 3 Zr 2 O 12 grain boundaries critically governs Li transport and nucleation. During conventional sintering, Al, Ta, and La segregate at grain boundaries, locally depleting Li and creating space-charge layers that lower total ionic conductivity. Simultaneously, this segregation leads to higher electronic conductivity along grain boundaries, which promotes Li nucleation at grain boundary edges with increased risk of dendrite formation. The underlying mechanism of segregation is governed by both thermodynamic driving forces and diffusion kinetics. Building on this understanding, we develop a strategy to achieve segregation-free grain boundaries through a rapid sintering protocol that utilizes the onset of solid-state softening. This approach yields transparent, polycrystalline Li 7 La 3 Zr 2 O 12 with negligible grain boundary impedance and enhanced dendrite tolerance. By elucidating the structural origins and electrochemical consequences of grain boundary segregation, this work provides a guidance for the rational optimization of solid electrolytes.

Energy - Storage