Film boiling heat transfer to water drops on a flat plate.
Mass evaporation rate and heat transfer coefficients for water drops supported by own superheated vapor over flat plate
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mass evaporation rate and heat transfer coefficients for water drops supported by own superheated vapor over flat plate
The operational and thermal performance of a variety of solar systems are described. The Solar Cooling System was installed in a hotel at St. Thomas, U. S. Virgin Islands. The system consists of the evacuated glass tube collectors, two 2500 gallon tanks, pumps, computerized controller, a large solar optimized industrial sized lithium bromide absorption chiller, and associated plumbing. Solar heated water is pumped through the system to the designed public areas such as lobby, lounges, restaurant and hallways. Auxiliary heat is provided by steam and a heat exchanger to supplement the solar heat.
Barlow (this meeting) has identified two potential source craters for the martian meteorite ALH84001. The craters are at 11.7 deg S, 243.3 deg W (Mare Tyrrhenum site) and 14.0 deg S, 343.5 deg W (Sinus Sabaeus site). As noted by Barlow, both craters lie in the heavily cratered terrain (HCT) and are adjacent to fluvial valleys, Here I explore the fluvial history of these areas based upon the surrounding valley morphology. The most prominent valley network at the Sabaeus site is Evros Vallis. This wide, flat-floored valley is approximately 600 km long with an average width of 2.5 km and a depth of 220 m. The eroded volume of the entire Evros network is approximately 6 x 10(exp 11) cc. This is typical for networks located in the heavily cratered terrain (e.g. Warrego and Parana Valles). Evros is also an isolated valley system. No similar networks are found in the surrounding terrain. Thus it is unlikely that Evros formed as a result of widespread rainfall. A localized water source, such as discharge of a hydrothermal system or localized melting of snowfall, seems more consistent Previous modeling has demonstrated that only hydrothermal systems associated with high permeability subsurfaces can discharge sufficient water to form a valley network. The bulk of the discharge from such systems is consequently low temperature, slightly heated water Precipitation of calcium carbonate by low temperature fluids is consistent with most interpretations of the geochemistry of ALH84001. Available imagery at the Tyrrhenum site is of lesser quality. While eroded units of the HCT are nearby, there are no comparable well developed valley networks at this site. Erosion is instead manifested predominantly as gullies on slopes. This style of erosion suggests that water was not present at this site for the length of time as at the more integrated Sabaeus site. The superposition of fluidized ejecta blankets suggests however that ground water or ground ice was still present at this locality fairly recently, if the chosen crater is indeed correct.
Experimental diffusion freezeout rates in a gas loaded heat pipe are presented and compared with predictions of an analysis and computer program published earlier. The experimental approach was to pivot a heat pipe on knife edges and use an analytical mass balance to measure the rate of mass migration within the pipe. Diffusion freezeout rates in a water heat pipe were measured as a function of the condenser sink temperature and the condenser-to-sink thermal conductance. Measured rates varied between 19 and 270 mg/hr and yielded 64 to 99 percent agreement with predicted values. These results indicated that the analysis and computer program for predicting the behavior of gas loaded heat pipes are useful tools for designing such systems.
The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.
Module uses phase change heat absorbing wax to reduce peak temperatures, increasing electrical efficiency. Wax makes module more cost effective than conventional thermomodules by also storing thermal energy for air and water heating.
A supercritical water oxidation system (SCWOS) offers several advantages for a lunar base environmental control/life support system (ECLSS) compared to an ECLSS based on Space Station technology. In supercritically heated water (630 K, 250 atm) organic materials mix freely with oxygen and undergo complete combustion. Inorganic salts lose solubility and precipitate out. Implementation of SCWOS can make an ECLSS more efficient and reliable by elimination of several subsystems and by reduction in potential losses of life support consumables. More complete closure of the total system reduces resupply requirements from the earth, a crucial cost item in maintaining a lunar base.
Discussion at the final design review meeting on the solar heating and hot water system for the multi-purpose Senior Center is presented. Schematics of the system are included.
Information necessary to evaluate the design of a solar space heating and hot water system is reported. System performance specifications, the design data brochure, the system description, and other information pertaining to the design are included.
The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.
The feasibility of directly converting solar energy for crew water heating on the Space Station Freedom (SSF) and other human-tended missions such as a geosynchronous space station, lunar base, or Mars spacecraft was investigated. Computer codes were developed to model the systems, and a proof-of-concept thermal vacuum test was conducted to evaluate system performance in an environment simulating the SSF. The results indicate that a solar water heater is feasible. It could provide up to 100 percent of the design heating load without a significant configuration change to the SSF or other missions. The solar heater system requires only 15 percent of the electricity that an all-electric system on the SSF would require. This allows a reduction in the solar array or a surplus of electricity for onboard experiments.
The climate of Mars has been more similar to that of Earth than has the climate of any other planet in our Solar System. But Mars still provides a valuable alternative example of how planetary processes and environments can affect the potential presence of life elsewhere. For example, although Mars also differentiated very early into a core, mantle and crust, it then evolved mostly if not completely without plate tectonics and has lost most of its early atmosphere. The Martian crust has been more stable than that of Earth, thus it has probably preserved a more complete record of its earliest history. Orbital observations determined that near-surface water was once pervasive. Orbiters have identified the following diverse aqueous sedimentary deposits: layered phyllosilicates, phyllosilicates in intracrater fans, plains sediments potentially harboring evaporitic minerals, deep phyllosilicates, carbonate-bearing deposits, intracrater clay-sulfate deposits, Meridiani-type layered deposits, valles-type layered deposits, hydrated silica-bearing deposits, and gypsum plains. These features, together with evidence of more vigorous past geologic activity, indicate that early climates were wetter and perhaps also somewhat warmer. The denser atmosphere that was required for liquid water to be stable on the surface also provided more substantial protection from radiation. Whereas ancient climates might have favored habitable environments at least in some localities, clearly much of the Martian surface for most of its history has been markedly less favorable for life. The combination of dry conditions, oxidizing surface environments and typically low rates of sedimentation are not conducive to the preservation of evidence of ancient environments and any biota. Thus a strategy is required whereby candidate sites are first identified and then characterized for their potential to preserve evidence of past habitable environments. Rovers are then sent to explore the most promising candidates. The Mars Exploration Rover (MER) Opportunity revealed that water once flowed to the surface across the vast Meridiani plains, creating saline lakes whose waters were roiled by ancient winds that also sculptured their salt deposits into sand dunes. Opportunity then drove more than 30 km to explore even older deposits on a crater rim. MER Spirit found evidence that thermal waters (heated by volcanism or by impacts?) altered rocks to create sulfate salts, and siliceous sinters. These discoveries indicate that an early hydrological cycle apparently sustained precipitation, streams and lakes. Liquid water participated in rock weathering reactions, such as iron and sulfur oxidation, that created distinctive weathering regimes. Volcanism, impacts, groundwater and ice interacted at least locally. Redox chemical energy from volcanism, hydrothermal activity and weathering of crustal materials would have been available for any life. Thus conditions might have supported life in the past, at least locally. The main objective of the Mars Science Laboratory (MSL) Curiosity rover is to determine the extent to which Gale crater hosted environments capable of supporting microbial life. The rover has already found stream gravels as well as sediments that might have been deposited in an ancient lake. The rover is now traversing to Mt. Sharp, a 5 km-high mound that is located on the crater floor and that exhibits layered sedimentary rocks having diverse minerals (sulfates and clays) that apparently formed in the presence of liquid water. This rock sequence was deposited over an extended time period in diverse potentially habitable watery environments. Curiosity is poised to characterize a a well-preserved rock record of hundreds of millions of years of diverse environments and profound climate change.
The preliminary design review on the development of two prototype solar heating and hot water systems is presented. The information contained in this report includes system certification, system functional description, system configuration, system specification, system performance and other documents pertaining to the progress and the design of the system. This system, which is intended for use in the normal single-family residence, consists of the following subsystems: collector, storage, control, transport, and Government-furnished Site Data Acquisition.
Solar heating and a hot water system installed in an elementary school in Portsmouth, Virginia are examined. The building is zoned into four heating/cooling areas. Each area is equipped with an air handling unit that is monitored and controlled by central control and monitoring system. The solar system for the building uses a collector area of 3,630 sq. ft. of flat plate liquid collectors, and a 6,000 gallon storage tank. System descriptions, maintenance reports, detailed component specifications, and design drawings to evaluate this solar system are reported.
Polymer matrix composites offer the promise of reducing the mass and increasing the performance of future heat rejection systems. With lifetimes for heat rejection systems reaching a decade or more in a micrometeoroid environment, use of multiple heat pipes for fault tolerant design is compelling. The combination of polymer matrix composites and heat pipes is of particular interest for heat rejection systems operating on the lunar surface. A technology development effort is under way to study the performance of two radiator demonstration units manufactured with different polymer matrix composite face sheet resin and bonding adhesives, along with different titanium-water heat pipe designs. Common to the two radiator demonstration units is the use of high thermal conductivity fibers in the face sheets and high thermal conductivity graphite saddles within a light weight aluminum honeycomb core. Testing of the radiator demonstration units included thermal vacuum exposure and thermal vacuum exposure with a simulated heat pipe failure. Steady state performance data were obtained at different operating temperatures to identify heat transfer and thermal resistance characteristics. Heat pipe failure was simulated by removing the input power from an individual heat pipe in order to identify the diminished performance characteristics of the entire panel after a micrometeoroid strike. Freeze-thaw performance was also of interest. This paper presents a summary of the two radiator demonstration units manufactured to support this technology development effort along with the thermal performance characteristics obtained to date. Future work will also be discussed.
Chlorofluorocarbons (CFC's) in the atmosphere are believed to present a major environmental problem because they are able to interact with and deplete the ozone layer. NASA has been mandated to replace chlorinated solvents in precision cleaning, cleanliness verification, and degreasing of aerospace fluid systems hardware and ground support equipment. KSC has a CFC phase-out plan which provides for the elimination of over 90 percent of the CFC and halon use by 1995. The Materials Science Laboratory and KSC is evaluating four analytical methods for the determination of nonvolatile residues removal by water: (1) infrared analyses using an attenuated total reflectance; (2) surface tension analyses, (3) total organic content analyses, and (4) turbidity analyses. This research project examined the ultrasonic-turbidity responses for 22 hydrocarbons in an effect to determine: (1) if ultrasonics in heated water (70 C) will clean hydrocarbons (oils, greases, gels, and fluids) from aerospace hardware; (2) if the cleaning process by ultrasonics will simultaneously emulsify the removed hydrocarbons in the water; and (3) if a turbidimeter can be used successfully as an analytical instrument for quantifying the removal of hydrocarbons. Sixteen of the 22 hydrocarbons tested showed that ultrasonics would remove it at least 90 percent of the contaminated hydrocarbon from the hardware in 10 minutes or less giving a good ultrasonic-turbidity response. Six hydrocarbons had a lower percentage removal, a slower removal rate, and a marginal ultrasonic-turbidity response.
Constant-density two-dimensional axisymmetric equations are presented for the diffusing flow of a class of self-controlled heat pipes. The analysis is restricted to the vapor space. Condensation of the vapor is related to its mass fraction at the wall by the gas kinetic formula. The Karman-Pohlhausen integral method is applied to obtain approximate solutions. Solutions are presented for a water heat pipe with neon control gas.
The solar energy system, Elcam San Diego, was designed to supply domestic hot water heating for a single family residence located in Encinitas, California. System description, performance assessment, operating energy, energy savings, maintenance, and conclusions are presented. The system is a 'Sunspot' two tank cascade type, where solar energy is supplied to either a 66 gallon preheat tank (solar storage) or a 40 gallon domestic hot water tank. Water is pumped directly from one of the two tanks, through the 65 square feet collector array and back into the same tank. Freeze protection is provided by automatically circulating hot water from the hot water tank through the collectors and exposed plumbing when freezing conditions exist. Auxiliary energy is supplied by natural gas. Analysis is based on instrumented system data monitored and collected for one full season of operation.