Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wearable device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive wireless sensors have applications in structural health monitoring and medical health monitoring. Doctors can take wireless blood pressure measurements inside arteries to monitor the progression of heart disease. Glaucoma patients can use this technology to monitor the pressure in their eyes to track the progression of the disease.

Dick, Jacob↗

High-specific-power flexible transition metal dichalcogenide solar cells

Abstract Semiconducting transition metal dichalcogenides (TMDs) are promising for flexible high-specific-power photovoltaics due to their ultrahigh optical absorption coefficients, desirable band gaps and self-passivated surfaces. However, challenges such as Fermi-level pinning at the metal contact–TMD interface and the inapplicability of traditional doping schemes have prevented most TMD solar cells from exceeding 2% power conversion efficiency (PCE). In addition, fabrication on flexible substrates tends to contaminate or damage TMD interfaces, further reducing performance. Here, we address these fundamental issues by employing: (1) transparent graphene contacts to mitigate Fermi-level pinning, (2) MoO x capping for doping, passivation and anti-reflection, and (3) a clean, non-damaging direct transfer method to realize devices on lightweight flexible polyimide substrates. These lead to record PCE of 5.1% and record specific power of 4.4 W g −1 for flexible TMD (WSe 2 ) solar cells, the latter on par with prevailing thin-film solar technologies cadmium telluride, copper indium gallium selenide, amorphous silicon and III-Vs. We further project that TMD solar cells could achieve specific power up to 46 W g −1 , creating unprecedented opportunities in a broad range of industries from aerospace to wearable and implantable electronics.

42 ENGINEERING↗

Conductive Ink with Circular Life Cycle for Printed Electronics

Electronic waste carries energetic costs and an environmental burden rivaling that of plastic waste due to the rarity and toxicity of the heavy-metal components. Recyclable conductive composites are introduced for printed circuits formulated with polycaprolactone (PCL), conductive fillers, and enzyme/protectant nanoclusters. Circuits can be printed with flexibility (breaking strain ≈80%) and conductivity (≈2.1 × 10 4 S m -1 ). These composites are degraded at the end of life by immersion in warm water with programmable latency. Approximately 94% of the functional fillers can be recycled and reused with similar device performance. The printed circuits remain functional and degradable after shelf storage for at least 7 months at room temperature and one month of continuous operation under electrical voltage. Here, the present studies provide composite design toward recyclable and easily disposable printed electronics for applications such as wearable electronics, biosensors, and soft robotics.

36 MATERIALS SCIENCE↗

Dielectric Engineering of ZnO@ZIF‐8 for High‐Performance Triboelectric Nanogenerators and Self‐Powered Humidity Sensors

Porous metal oxide–metal-organic framework (MO x @MOF) hybrids offer synergistic effects that enhance surface charge density, electronic structure, and textural properties, making them ideal for self-powered sensing applications. Here, uniform, and pinhole-free ternary porous ZnO–PTFE@ZIF-8 hybrid films are developed on room-temperature co-sputtered ZnO–polytetrafluoroethylene (PTFE) composite films, where ZnO serves as a self-sacrificial precursor to precisely regulate ZIF-8 (Zn-MeIm 2 ) growth through solvothermal methods. The resulting TENG achieves a high output power density of 0.67 mW cm −2 , attributed to the synergistic effects of fluorine-rich PTFE and methyl-functionalized ZIF-8, which enhance surface charge density and dielectric response. By tuning PTFE content in the ZnO–PTFE composite, the dielectric constant and triboelectric output is optimized. The ZP60@ZIF-8-based device also demonstrates excellent humidity sensing performance, with a wide detection range (20–99% RH) and ultrahigh sensitivity (R V % of 19 900%, R I % of 19 325% at 99% RH). These results position ZP@ZIF-8-based TENGs as promising platforms for next-generation self-powered sensors and smart wearable electronics.

42 ENGINEERING↗

Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars

The Moon to Mars eXploration Systems and Habitation (M2M X-Hab) 2024 Academic Innovation Challenge features a project titled “Intelligent Devices/Equipment/Instruments (IDEI) for Enabling Crew Health and Performance on Mars”. The project calls for the development of prototype IDEIs “that could be used for implementing integrated system health management for Crew Health and Performance (CHP) required for crew living on Mars for extended periods of time”. Thus, the deliverable for the project is not only a prototype exercise device, but also an ontology that provides insight into the best ways to exercise on Mars. To that end, we on the BLiSS team, supported by advisors from industry and academia, set out to ideate an exercise ontology and demonstrate its effectiveness through a functional prototype. To achieve the stakeholders’ requests, the device must operate semi-autonomously, must be an analog for an extant exercise device on Earth, and must provide quantitative information about the exercise and the device’s own state of health. Here, we define “semi-autonomous” as referring to the fact that while the system should be as autonomous as possible, there are some processes that the system cannot fulfill on its own. These include, but are not limited to, user identification, physical exercise reconfiguration, and wearable sensor placement.

llyana Smith↗

A Printed Microscopic Universal Gradient Interface for Super Stretchable Strain‐Insensitive Bioelectronics

Abstract Stretchable electronics capable of conforming to nonplanar and dynamic human body surfaces are central for creating implantable and on‐skin devices for high‐fidelity monitoring of diverse physiological signals. While various strategies have been developed to produce stretchable devices, the signals collected from such devices are often highly sensitive to local strain, resulting in inevitable convolution with surface strain‐induced motion artifacts that are difficult to distinguish from intrinsic physiological signals. Here all‐printed super stretchable strain‐insensitive bioelectronics using a unique universal gradient interface (UGI) are reported to bridge the gap between soft biomaterials and stiff electronic materials. Leveraging a versatile aerosol‐based multi‐materials printing technique that allows precise spatial control over the local stiffnesses with submicron resolution, the UGI enables strain‐insensitive electronic devices with negligible resistivity changes under a 180% uniaxial stretch ratio. Various stretchable devices are directly printed on the UGI for on‐skin health monitoring with high signal quality and near‐perfect immunity to motion artifacts, including semiconductor‐based photodetectors for sensing blood oxygen saturation levels and metal‐based temperature sensors. The concept in this work will significantly simplify the fabrication and accelerate the development of a broad range of wearable and implantable bioelectronics for real‐time health monitoring and personalized therapeutics.

Song, Kaidong [Department of Aerospace and Mechani↗

High Mobility, High Carrier Density SnSe 2 Field‐Effect Transistors with Ultralow Subthreshold Swing and Gate‐Controlled Photoconductance Switching

2D and layered semiconductors are considered as promising electronic materials, particularly for applications that require high carrier mobility and efficient field-effect switching combined with mechanical flexibility. To date, however, the highest mobility has been realized primarily at low carrier concentration. Here, it is shown that few-layer/multilayer SnSe 2 gated by a solution top gate combines very high room-temperature electron mobility (up to 800 cm 2 V −1 s −1 ), along with large on-off current ratios (>10 5 ) and a subthreshold swing below the thermodynamic limit (50 mV per decade) in field-effect devices, at exceptionally large sheet carrier concentrations of ≈10 13 cm −2 . Observed mobility enhancements upon partial depletion of the channel point to near-surface defects or impurities as the mobility-limiting scattering centers. Under illumination, the resulting gap states give rise to gate-controlled switching between positive and negative photoconductance. The results qualify SnSe 2 as a promising layered semiconductor for flexible and wearable electronics, as well as for the realization of advanced approaches to photodetection.

36 MATERIALS SCIENCE↗

Dynamic disulfide bond networks enable self-healable and mechanically resilient intrinsically stretchable organic solar cells

A dynamic disulfide network introduced into donor/acceptor blends enables room-temperature self-healing and mechanical resilience in intrinsically stretchable organic solar cells, achieving performance recovery after high mechanical strain. The development of intrinsically stretchable organic solar cells (IS-OSCs) faces significant challenges in balancing mechanical durability and optoelectronic performance. Conventional π-conjugated polymer-based donor/acceptor blend films often exhibit limited stretchability and irreversible performance degradation under mechanical strain. To address these limitations, we propose a novel self-healable donor/acceptor blended film with a dual-network morphology, achieved by incorporating a dynamic disulfide bond-based crosslinked network into the bulk-heterojunction film. The resulting thin films demonstrate a power conversion efficiency (PCE) of 16.39% in rigid OSC devices and a fracture strain of 15.6%. Remarkably, the IS-OSCs retain 80% of their initial PCE under 30% strain and exhibit performance recovery after multiple stretch-release cycles at 40% strain through a room-temperature self-healing process. This work provides a proof-of-concept for highly stretchable and durable IS-OSCs, offering valuable insights for advancing the field of wearable energy systems, adaptive solar textiles, and sustainable electronics.

Yang, Wenyu↗

Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate

Abstract Many health diagnostic systems demand noninvasive sensing of respiratory rate, respiratory volume, and heart rate with high user comfort. Previous methods often require multiple sensors, including skin-touch electrodes, tension belts, or nearby off-the-body readers, and hence are uncomfortable or inconvenient. This paper presents an over-clothing wearable radio-frequency sensor study, conducted on 20 healthy participants (14 females) performing voluntary breathing exercises in various postures. Two prototype sensors were placed on the participants, one close to the heart and the other below the xiphoid process to couple to the motion from heart, lungs and diaphragm, by the near-field coherent sensing principle. We can achieve a satisfactory correlation of our sensor with the reference devices for the three vital signs: heart rate ( r = 0.95), respiratory rate ( r = 0.93) and respiratory volume ( r = 0.84). We also detected voluntary breath-hold periods with an accuracy of 96%. Further, the participants performed a breathing exercise by contracting abdomen inwards while holding breath, leading to paradoxical outward thorax motion under the isovolumetric condition, which was detected with an accuracy of 83%.

60 APPLIED LIFE SCIENCES↗

Programmable soft valves for digital and analog control

In soft devices, complex actuation sequences and precise force control typically require hard electronic valves and microcontrollers. Existing designs for entirely soft pneumatic control systems are capable of either digital or analog operation, but not both, and are limited by speed of actuation, range of pressure, time required for fabrication, or loss of power through pull-down resistors. Using the nonlinear mechanics intrinsic to structures composed of soft materials—in this case, by leveraging membrane inversion and tube kinking—two modular soft components are developed: a piston actuator and a bistable pneumatic switch. These two components combine to create valves capable of analog pressure regulation, simplified digital logic, controlled oscillation, nonvolatile memory storage, linear actuation, and interfacing with human users in both digital and analog formats. Three demonstrations showcase the capabilities of systems constructed from these valves: 1) a wearable glove capable of analog control of a soft artificial robotic hand based on input from a human user’s fingers, 2) a human-controlled cushion matrix designed for use in medical care, and 3) an untethered robot which travels a distance dynamically programmed at the time of operation to retrieve an object. This work illustrates pathways for complementary digital and analog control of soft robots using a unified valve design.

42 ENGINEERING↗

Additive manufacturing and applications of nanomaterial-based sensors

Nanoscale materials possess distinct physical and chemical attributes including size-dependent properties, quantum confinement, high surface-to-volume ratio, and superior catalytic activity. These unique qualities enable sensors with high sensitivity, robustness, and fast time response. As the emergence of the Internet of Things (IoT) demands increased production of sensors, it also provides an impetus for concentrated nanomaterial-based sensor research. Meanwhile, additive manufacturing (AM) of nanomaterial-based sensors is critical to bridge the gap between one-off, lab-scale fabrication and cost-effective, industrial-scale production with high reproducibility. By applying the design flexibility and cost savings of AM techniques, a new generation of nanomaterial-based sensing platforms can be integrated with IoT devices in the consumer space. Furthermore, emergent research in human-machine interfaces, food safety, and point-of-care diagnostics will be expedited by the development of sensors that can be printed with irregular form factors. In this Review, the relative strengths and weaknesses of printed sensor systems based on zero-, one-, and two-dimensional nanomaterials are discussed. In addition, sensors enabled by printable soft nanomaterials, heterostructures, and nanocomposites are surveyed due to their synergistic advantages for wearable healthcare monitoring and soft robotics. Lastly, a roadmap for the next decade of research on this topic is provided.

36 MATERIALS SCIENCE↗

Direct writing of PVBVA/Ti 3 C 2 T x (MXene) triboelectric nanogenerators for energy harvesting and sensing applications

Triboelectric nanogenerators (TENGs) have gained recognition for their potential to convert mechanical energy into electrical energy, making them attractive for applications in healthcare, robotics, and human-device interfaces. However, many TENG devices rely on fluorinated polymers for high charge generation and involve complex fabrication processes, which limit their practicality and environmental sustainability. Here, we developed an eco-friendly composite of poly (vinyl butyral-co-vinyl alcohol-co-vinyl acetate) (PVBVA) and Ti 3 C 2 T x MXene for extrusion printing onto aluminum foil substrates, enabling the additive manufacturing of TENGs. Experimental results indicate that integrating 5.5 mg mL -1 of MXene (P-MX 5.5) into PVBVA resulted in a power density of 760 mW·m -2 , with simultaneous improvements in open-circuit voltage (129 %) and short-circuit current (250 %), demonstrating enhanced charge transfer efficiency. Beyond aluminum foil-based devices, we further explored the fully printed P-MX 5.5 TENG by utilizing silver ink electrodes, eliminating the need for aluminum foil. This fully printed, flexible TENG was successfully used for real-time human motion sensing, demonstrating its ability to detect activities such as walking, running, knee bending, and jumping. Collectively, our additively manufactured and sustainable PVBVA-MXene TENG composites, including both aluminum-based and fully printed versions, show promise for future energy harvesters, sensors, wearable electronics, healthcare, and robotic applications.

Additive manufacturing↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

Providing adequate carbon dioxide (CO2) washout is essential to the reduction of risk in performing suited operations. Long term CO2 exposure can lead to symptoms such as headache, lethargy, dizziness, and in severe cases can lead to unconsciousness and death. Thus maintaining adequate CO2 washout in both ground testing and during in flight EVAs is a requirement of current and future suit designs. It is necessary to understand the inspired CO2 of suit wearers such that future requirements for space suits appropriately address the risk of inadequate washout. Testing conducted by the EVA Physiology Laboratory at the NASA Johnson Space Center aimed to characterize a method for noninvasively measuring inspired oronasal CO2 under pressurized suited conditions in order to better inform requirements definition and verification techniques for future CO2 washout limits in space suits. Prior work conducted by the EPL examined several different wearable, respirator style, masks that could be used to sample air from the vicinity surround the nose and mouth of a suited test subject. Previously published studies utilized these masks, some being commercial products and some novel designs, to monitor CO2 under various exercise and flow conditions with mixed results for repeatability and/or consistency between subjects. Based on a meta-analysis of those studies it was decided to test a nasal cannula as it is a commercially available device that is placed directly in the flow path of the user as they breathe. A nasal cannula was used to sample air inhaled by the test subjects during both rest and exercise conditions. Eight subjects were tasked with walking on a treadmill or operating an arm ergometer to reach target metabolic rates of 1000, 2000, and 3000 BTU/hr. Suit pressure was maintained at 4.3 psid for all tests, with supply flow rates of 6, 4, and 2 actual cubic feet per minute depending on the test condition. Each test configuration was conducted twice with subjects breathing either through their nose only, or however they felt comfortable. By restricting breathing through a single orifice, we are able to more accurately define exactly what flow stream the sampled CO2 is taken from. Oronasal CO2 was monitored using real time infrared gas analyzers fed via sample tubes connected to the nasal cannula within the suit. Two additional sampling tubes were placed at the head and chin of the test subject, in an effort to capture CO2 concentrations across the entire flow stream of the Mark-III vent system (flow path is head to neck). Metabolic rate was calculated via the exhaust CO2 concentration and used to adjust subject workload on either the treadmill or arm ergometer until the target was reached. Forward work will aim to characterize the historically accepted minimum ppCO2 in suit during EVA by repeating this study in the Extravehicular Mobility Unit (EMU) space suit. This will help to define washout requirements for future suits, be they NASA (e.g. Z-2) or Commercial Crew designed. Additionally it is important to determine the functional consequences of CO2 exposure during EVA. Severe CO2 symptoms are a result of very high concentration, acute exposures. While long term, low concentration exposures have been shown to result in slight cognitive decline, symptoms resolve upon quickly returning to nominal concentrations and it remains unknown the impact that minor deficits in cognitive performance can have on EVA performance.

Norcross, J.↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗

Medical Signal-Conditioning and Data-Interface System

A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

Braun, Jeffrey↗

Market Survey 2020: Commercial Clinical Decision Support Systems and Wellness Tools

For long-duration, deep space exploration missions, current methods for managing and supporting crew health and medical conditions will be unsuitable. Communication and data transmission lags will necessitate the use of a sophisticated clinical decision support system (CDSS) that will tailor diagnosis and treatment guidance that is context-sensitive for anticipated astronaut health, wellness, and medical conditions. A variety of clinical decision support (CDS) and wellness tools (WT) are currently available in the commercial market and a broad-brush survey of this market can provide an initial impression of the current state of the art which, in turn, can inform the roadmap of NASA deep space CDSS development and associated requirements. Such a survey was undertaken during the first six months of 2020 using directed convenience sampling to obtain information provided by vendors on their websites; both commercially available CDS and WT (such as those used to track and monitor nutrition, exercise, and sleep) were included. Areas assessed were item type (e.g., software/application, device); primary purpose of the item (e.g., diagnostic support, nutrition tracking); additional purposes (if any); reported features, capabilities, and functionality; setting of use (e.g., inpatient, outpatient); intended user (e.g., clinician, patient); location and sources of data/information used or produced by the item; integration with patient electronic health record (EHR); compliance with interoperability ontologies and standards (e.g., Health Level 7 [HL7], Systematized Nomenclature of Medicine – Clinical Terminology [SNOMED-CT]); and whether the item is knowledge-based (derived from research findings) or non-knowledge-based (derived through artificial intelligence, machine learning, advanced probability and statistics), among others. Ninety-seven (97) vendor websites describing 196 CDS and 73 WT (269 total) were reviewed and coded. The primary purpose of the majority of CDS reviewed is diagnosis or diagnosis/treatment/drug decision support—targeted for clinician use— and the primary purpose of the majority of WT reviewed is the monitoring of different health metrics, most often through the use of a biosensor device (e.g., blood pressure)—targeted for patient use. Very few CDS or WT appear to comply with major international interoperability standards or can be integrated with a patient’s EHR data. None consider contextual factors, such as conditions of the physical environment (e.g., CO2 levels). The majority of CDS and WT reviewed are non-knowledge, cloud- or web-based applications or software. Forty-three (43) major findings were identified and the implications those findings have for NASA will be discussed. Example major findings include: CDS-WT capabilities range from diagnosis to treatment applications, CDS-WT may be wearable or non-wearable and are technologically advanced and only a few CDS-WT tools referenced compliance to ensure interoperability, among other findings. Recommendations will also be offered that will help to address ExMC Gap, Medical-701: Enhance medical capabilities within an exploration medical system.

market survey↗

Application of Bioengineering in Space Exploration - Sleep Study System

Bioengineering has spread roots far and wide among the needs of space exploration. The field creates many of paths to generate information from a variety of sources. One such source is the astronauts on the International Space Station (ISS). As of now the investigation is focused on the quality of sleep of crew members during a long duration flight. Our team is investing time into a piece of hardware’s comfort, waste, and operability. The hardware was not originally designed for space; therefore, the device must be modified to function at a optimal level in space. The design not made for space has generated some ailments, such as discomfort and decreased mobility. A function of the internship was to produce designs that would manage the wires to increase mobility and comfort. The wires excess slack was reduced by the part that was designed. The piece was adjustable, so the patient may adjust the system to their comfort and space compatible material was used. This product will help control the direction and length of the wires, thereby aiding in comforting the patient. This multifaceted design may be used in future for all other wire management for wearable biomedical sensor on orbit.

Biomedical↗