Search NASA⌕ Search

SEARCH · Search NASA

Results for “Weather Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Application of a Genetic Algorithm to the Optimization of a Mesoscale Model for Emergency Response

Besides solving the equations of momentum, heat, and moisture transport on the model grid, mesoscale weather models must account for subgrid-scale processes that affect the resolved model variables. These are simulated with model parameterizations, which often rely on values preset by the user. Such “free” model parameters, along with others set to initialize the model, are often poorly constrained, requiring that a user select each from a range of plausible values. Finding the values to optimize any forecasting tool can be accomplished with a search algorithm, and one such process—the genetic algorithm (GA)—has become especially popular. As applied to modeling, GAs represent a Darwinian process: an ensemble of simulations is run with a different set of parameter values for each member, and the members subsequently judged to be most accurate are selected as “parents” who pass their parameters onto a new generation. At the U.S. Department of Energy’s Savannah River Site in South Carolina, we are applying a GA to the Regional Atmospheric Modeling System (RAMS) mesoscale weather model, which supplies input to a model to simulate the dispersion of an airborne contaminant as part of the site’s emergency response preparations. An ensemble of forecasts is run each day, weather data are used to “score” the individual members of the ensemble, and the parameters from the best members are used for the next day’s forecasts. As meteorological conditions change, the parameters change as well, maintaining a model configuration that is best adapted to atmospheric conditions. Significance Statement We wanted to develop a forecasting system by which a weather model is run over the Savannah River Site each day and repeatedly adjusted according to how well it performed the previous day. To run the model, a series of values (parameters) must be set to control how the model will calculate winds, temperatures, and other desired variables. Each day the model was run several times using different combinations of these parameters and later compared with observed meteorological conditions. Parameters that produced the most accurate forecasts were preferentially reused to create the forecasts for the next day. The process was tested for the summer of 2020 and exhibited lower errors than forecasts produced by the model using default values of the parameters.

54 ENVIRONMENTAL SCIENCES↗

De-Risking Large-Scale PV Systems Through Data Analytics

Large-scale photovoltaic system performance analysis is being conducted within the US Department of Energy's-sponsored PV Fleet Performance Data Initiative. This collaboration with commercial PV system owners collects and evaluates PV field performance data, and provides reports on aggregated results. Drawing on over 2200 sites across the US and over 24,000 separate PV inverters we have collected in excess of 8.3 gigawatts (GW) of performance data, representing 6-7% of the entire US installed PV capacity. A mixture of utility-scale and large commercial systems are represented, averaging 4.1 megawatts (MW) in size and 5 years in age. Initial results show average system degradation rates at -0.75% / year, which is slightly higher than historically reported module-level values of -0.5%/year. We also found that the availability of systems averaged 97.7%, which is lower than the typical 99% uptime assumed by many project economic forecasts. Given these results, we compared monthly performance with expected production values, based on satellite weather data and a simple PVWatts performance model. We found that systems were performing within 10% of monthly expectation over 90% of the time, with a fleet average vs expected monthly value of 0.994. We also evaluated the impact of extreme weather events on system performance, and found a range of short-term and longer-term performance effects ranging from grid outage, system downtime, module damage and accelerated long-term degradation rate.

analysis↗

Determining circuit model parameters from operation data for PV system degradation analysis: $\mathrm{PVPRO}$

Physics-based circuit parameters like series and shunt resistance are essential to provide insights into the degradation status of photovoltaic (PV) arrays. However, calculating these parameters typically requires a full current-voltage characteristic (I-V curve), the acquisition of which involves specific measurement devices and costly methods. Thus, I-V curves of the PV system level are often not available. Here this paper proposes a methodology (PVPRO) to estimate these I-V curve parameters using only operation (string-level DC voltage and current) and weather data (irradiance and temperature). PVPRO first performs multi-stage data pre-processing to remove noisy data. Next, the time-series DC data are used to fit an equivalent circuit single-diode model (SDM) to estimate the circuit parameters by minimizing the differences between the measured and estimated values. In this way, the time evolutions of the SDM parameters are obtained. We evaluate PVPRO on synthetic datasets and find an excellent estimation of both SDM and the key I-V parameters (e.g., open-circuit voltage, short-circuit current, maximum power, etc.) with an average relative error of 0.55%. The performance, especially the extracted degradation rate of parameters, is robust to various measurement noises and the presence of faults. In addition, PVPRO is applied to a 271 kW PV field system. The relative error between the real and estimated operation voltage and current is less than 1%, suggesting that degradation trends are well captured. PVPRO represents a promising open-source tool to extract the time-series degradation trends of key PV parameters from routine operation data.

14 SOLAR ENERGY↗

Quantifying and simulating the weather forecast uncertainty for advanced building control

Weather forecast uncertainty is unavoidable despite technological advancements. Accurately quantifying and modelling this uncertainty is essential for developing and comparing advanced building controllers. In this study, we present a structured approach using a first-order autoregressive model (AR(1)) to model uncertainty in ambient temperature and global solar irradiation (GHI) forecasts. We analyzed weather data from four cities and employed Jensen–Shannon divergence (JSD) to evaluate the similarity between synthetic and actual forecast errors. The average JSD values for temperature are 0.027 (Berkeley), 0.021 (Leuven), 0.018 (Berlin), and 0.008 (Oslo), and for GHI, the average JSD values are 0.016 (Berkeley), 0.058 (Leuven), and 0.013 (Berlin). The low JSD values indicate a high similarity between the synthetic and real forecast error distributions. Further, our approach successfully generates synthetic weather forecasts that mirror the statistical properties of actual forecasts. The implementation of our method for uncertain forecast generation is being added to the BOPTEST framework.

54 ENVIRONMENTAL SCIENCES↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evapotranspiration of advanced perennial bioenergy grasses produced on marginal land in the U.S. Midwest

The production of dedicated energy crops for biofuel and co-products can help develop a sustainable and viable bioeconomy under a changing climate. The co-production of perennial bioenergy and commodity crops in an agricultural landscape has the potential to reduce greenhouse gas emissions and provide numerous ecosystem services. However, as production of advanced, higher-yielding cultivars occurs, their impact on water resources needs to be considered. Estimates of evapotranspiration (ET) of perennial grasses compared to commodity crops are not always consistent in the literature. In this study, ET was estimated using an energy-balance model with Landsat satellite imagery and ground-based weather data to compare the large-scale production of advanced switchgrass cultivars (‘Independence’, ‘Liberty’, and ‘Carthage’), predecessor cultivars (‘Shawnee’ and ‘Sunburst’), and other perennial grasses (big bluestem and a low-diversity mixture) to corn grown continuously on marginal soils in the U.S. Midwest. Results showed significant differences in ET between corn and perennial grass treatments at four of the five field sites. However, differences between crop treatments were not consistent across sites, nor were the differences between advanced and predecessor switchgrass varieties. Production year played a large role in daily and cumulative ET across all sites. Differences in crop biomass yield between establishment and post-establishment years may contribute to these interannual differences. Site and interannual variations in precipitation and temperature may also be major contributing factors. Overall, the results of this study indicate that differences in ET between perennial bioenergy grasses and corn are likely dependent upon location of production and weather conditions.

09 BIOMASS FUELS↗

Machine Learning Emulation of Spatial Deposition from a Multi-Physics Ensemble of Weather and Atmospheric Transport Models

In the event of an accidental or intentional hazardous material release in the atmosphere, researchers often run physics-based atmospheric transport and dispersion models to predict the extent and variation of the contaminant spread. These predictions are imperfect due to propagated uncertainty from atmospheric model physics (or parameterizations) and weather data initial conditions. Ensembles of simulations can be used to estimate uncertainty, but running large ensembles is often very time consuming and resource intensive, even using large supercomputers. In this paper, we present a machine-learning-based method which can be used to quickly emulate spatial deposition patterns from a multi-physics ensemble of dispersion simulations. We use a hybrid linear and logistic regression method that can predict deposition in more than 100,000 grid cells with as few as fifty training examples. Logistic regression provides probabilistic predictions of the presence or absence of hazardous materials, while linear regression predicts the quantity of hazardous materials. The coefficients of the linear regressions also open avenues of exploration regarding interpretability—the presented model can be used to find which physics schemes are most important over different spatial areas. A single regression prediction is on the order of 10,000 times faster than running a weather and dispersion simulation. However, considering the number of weather and dispersion simulations needed to train the regressions, the speed-up achieved when considering the whole ensemble is about 24 times. Ultimately, this work will allow atmospheric researchers to produce potential contamination scenarios with uncertainty estimates faster than previously possible, aiding public servants and first responders.

97 MATHEMATICS AND COMPUTING↗

Smart-DS: Synthetic Models for Advanced, Realistic Testing: Distribution Systems and Scenarios

The explosion of new ideas for distributed energy resources and advanced distribution grid algorithms faces a critical challenge: how can one effectively develop and evaluate these breakthrough technologies without an adequate set of power systems network, load, and resource data to test against? Today's open test systems, particularly for distribution systems, are tiny and incomplete; and though with enough effort, obtaining utility data under NDA can overcome scale challenges, the results can't be openly shared, preventing fair comparison. The Smart-DS project-led by NREL in partnership with MIT, Universidad Pontificia Comillas, CYME, and EDD-is working to overcome this gap by generating multiple large-scale, open, synthetic, distribution systems that are realistic but not real. These datasets go beyond a single medium voltage feeder (~1000 customers) to cover entire metropolitan areas and their surrounds with up to hundreds of feeders and millions of customers, complete with low voltage customer connections and high voltage sub-transmission. This scale allows adequate testing and analysis of not just local controls and advanced DERs, but also multiple substation interactions, optimized switching, full-scale distribution-OPF, and more. To accompany these datasets, the project is also building a rich set of scenario generation tools that can be used for distribution and transmission systems alike. This includes automated, spatially aware access to world-class, high-resolution solar, wind, and weather data: forward looking generation mixes: and highly configurable DER, load, climate, outage, control-scheme, and other scenarios. We will also highlight DiTTo, an exciting open-source, multi-way distribution dataset transformation tool for many-to-many format translation with scenario, merge/split, and many other manipulation capabilities.

DERs↗

Multi-criteria thermal resilience certification scheme for indoor built environments during heat waves

With climate change, the indoor built environment is expected to significantly influence the occupant's safety and well-being. A novel multi-criteria thermal resilience certification scheme for indoor built environments during extreme heat events is proposed in this paper. The certification scheme considers overheating, thermal comfort, heat stress, and hygrothermal discomfort in built environments. These criteria are quantified using key performance indicators like indoor overheating degree, hours of exceedance, wet-bulb globe temperature, and heat index, respectively. This scheme is developed based on existing best practices like standards, rating systems, and literature. The scheme is implemented on a benchmark building energy performance model for detached post-World War II dwellings in Belgium as a case study using weather data measured from the City of Brussels. The indoor overheating in the reference dwelling is assessed with a static threshold of 27 °C for the bedrooms and adaptive thresholds for other areas. The analysis found that the building performance is within the defined threshold levels throughout the heat wave duration for all criteria. Therefore, the reference dwelling got a maximum attainable score of four points and is rated five-star for thermal resilience during heat waves. The proposed certification scheme is intended as a standardized framework and highlights the need for further revisions in building performance policies and guidelines.

Climate change↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Evaluation of hybrid evaporative-vapor compression air conditioners for different global climates

Currently, a majority of global residential air-conditioning requirements are met using cooling systems based on the vapor compression cycle (VCC). To meet the future demand for space cooling and to reduce the corresponding environmental impact, there is a need for alternative cooling systems which require less resources and exhibit a higher coefficient of performance (COP). One of proposed alternatives is called the hybrid evaporative-vapor compression (HEVC) cycle, which utilizes adiabatic latent cooling in combination with the VCC. In this paper, we conducted a feasibility analysis of a HEVC system by comparing its performance to that of VCC for various global climates. To accomplish this, we developed and validated models to simulate the performance of residential VCC and HEVC systems. ASHRAE weather data and design conditions were then used to compare the performance of the two systems. In general, HEVC systems are best suited for hot arid climates with energy reduction greater than 20%. Conversely, humid climates are not suitable for HEVC adoption due to degraded performance of evaporative coolers in these climates. In addition to comparing the energy savings from HEVC systems, it is also critical to analyze their water consumption. Generally, climates that benefit the most from HEVC technology tend to also experience water scarcity issues. Thus, both the energy savings and water consumption of HEVC systems must be analyzed to guide the discussion on their adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Deep Reductions in Energy Storage Costs on Highly Reliable Wind and Solar Electricity Systems.

We use 36 years (1980-2015) of hourly weather data over the contiguous United States (CONUS) to assess the impact of low-cost energy storage on highly reliable electricity systems that use only variable renewable energy (VRE; wind and solar photovoltaics). Even assuming perfect transmission of wind and solar generation aggregated over CONUS, energy storage costs would need to decrease several hundred-fold from current costs (to ~$1/kWh) in fully VRE electricity systems to yield highly reliable electricity without extensive curtailment of VRE generation. The role of energy storage changes from high-cost storage competing with curtailment to fill short-term gaps between VRE generation and hourly demand to near-free storage serving as seasonal storage for VRE resources. Energy storage faces "double penalties" in VRE/storage systems: with increasing capacity, (1) the additional storage is used less frequently and (2) hourly electricity costs would become less volatile, thus reducing price arbitrage opportunities for the additional storage.

14 SOLAR ENERGY↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Performance assessment of a real water source heat pump within a hardware-in-the-loop (HIL) testing environment

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while also maintaining the thermal comfort of building occupants. As the pivotal point between building electricity consumption and indoor thermal comfort, high-efficiency electrical vapor-compression heat pumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on heat pump operation and performance when subjected to different weather conditions, building loads, and grid requests calls for investigation and verification via experimental testing with actual heat pumps integrated with real-time building and grid responses. This study introduces a Water-Source Heat Pump (WSHP) Hardware-in-The-Loop (HIL) Test Facility that is the first of its kind. This testbed utilizes a 2-ton variable speed water-to-air heat pump that is capable of interacting with a virtual environment currently comprised of an EnergyPlus (E+) building simulation, an agent-based occupant behavioral model, and a single U-tube ground-loop heat exchanger (GLHE) model. Detailed descriptions of the testbed’s physical design and operation, virtual environment, as well as their mutual communication is provided. An uncertainty analysis is also performed under manufacturer specified heating and cooling design conditions. This analysis shows that the total load across the WSHP’s demand side heat exchanger, i.e., the sum of its latent and sensible components, can be measured with a relative uncertainty of ± 10.4% and ± 3.6% in cooling and heating mode respectively. The WSHP’s coefficient of performance (COP) can be measured with relative uncertainties of ± 10.4% in cooling mode, and ± 3.7% in heating mode. A preliminary 24-h experimental demonstration is then performed utilizing the DOE prototype small commercial office building model in E+. The simulation takes place in Atlanta, GA on the date of 08/26/15 from 12:00 AM to 11:59 PM using TMY3 weather data. Here, the results from this demonstration show that over the course of this experiment the simulated outputs of zone dry-bulb temperature, zone humidity ratio, and WSHP inlet water temperature can be tracked by testbed emulators up to a root mean squared error (RMSE) of ± 0.27 °C, ± 0.376 g/kg, and ± 0.85 °C respectively. The WSHP’s dynamic behavioral characteristics and performance are also captured, and correspond well with the authors’ previous understanding of heat pump efficiency as a function of evaporator and condenser fluid inlet conditions respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Rear-Side Irradiance Simulation of Field PV Modules

Assessing the durability of photovoltaic (PV) module backsheet is critical to increasing module lifetime. Historically, laboratory-based accelerated testing has insufficient in predicting large-scale failures of commercial polymeric materials. Additionally, there is growing concern that standard condition tests do not reflect non-uniformities in field exposure, and that certain modules experience more severe degradation due to their location. Anisotropy in field exposures is installation-dependent and reflects different levels of exposure to irradiance due to mounting geometry, ground surface albedo, and climatic zone. "Bificial_Radiance" [1], simulates the amount of reflected irradiance on the Polyethylene Naphthalate (PEN) backsheet of a PV array located in Maryland. In our work, site specific weather data are gathered for the entire length of exposure for the modules. The total full-spectrum dose for the incident irradiance on the backsheet was then determined. The simulation results are integrated with historical field survey data to better understand real orld outdoor degradation.

backsheet↗