At least 145 records · Page 8

Adaptive Quantizer for Burst Synthetic-Aperture Radar

Adaptive quantizer for burst-mode synthetic-aperture radar reduces data rate of return signal. Device, called block floating-point quantizer (BFPQ) basically analog-to-digital converter that covers wide dynamic range and discards appropriate lower order bits. BFPQ is, in effect, digital approximator with automatic gain control. Moves floatingpoint marker binary representation of signal data in accordance with perceived dynamic range. Available step sizes thus limited to multiples of underlying smallest quantization step (represented by lowest order bit). Retains only first K most significant bits of signal; (L,K) BFPQ is one that does K-bit quantization of signal originally quantized to L bits. Quantization error simply difference between actual signal level and its binary approximation. Other potential applications for BFPQ include speech compression and picture data compression.

Joo, T. H.↗

Star field simulator

A Star Field Simulator has been developed to serve as a source of radiation for the ASTRO Star Tracker. The star tracker and simulator are components of a motion compensation test facility located at Marshall Space Flight Center in Huntsville, Alabama. Preflight tests and simulations using various levels of guide stars are performed in the test facility to establish performance of the motion compensation system before being used in a flight environment. The ASTRO Star Tracker operates over a wide dynamic range of irradiance corresponding to visual stellar magnitudes of -0.8 to 8. A minimum of three simulated guide stars with variable magnitudes are needed to fully test the Star Tracker performance under simulated mission conditions.

Source record↗

Antenna arraying of Voyager telemetry signals by symbol stream combining

Telemetry signals received from the Voyager 2 spacecraft at Deep Space Stations at Parkes and Canberra, Australia, on February 6, 1986, were combined by the method of symbol stream combining. This second demonstration of symbol stream combining followed the International Cometary Explorer (ICE) demonstration at Giacobini-Zinner encounter in September 1985. The Voyager demonstration was at a symbol rate of 43.2 ksymb/s, compared to 2 ksymb/s for ICE. Recording, playback, and combining at this higher rate were demonstrated. The average symbol signal-to-noise ratio (SNR) of the combined data was 2.84 dB, or 0.23 dB less than the sum of the SNRs of the two imput symbol streams. This 0.23 loss from ideal combining was due to use of 4-bit quantization of the input symbol stream and imperfect scaling. A practical implementation with 8-bit quantization could achieve combining losses of under 0.05 dB over a wide dynamic range of input signal levels.

Hurd, W. J.↗

Observations of the seasonal variability of soil moisture and vegetation cover over Africa using satellite microwave radiometry

Multispectral passive microwave data from the scanning multichannel microwave radiometer (SMMR) on the Nimbus-7 satellite were processed selectively for a 1 yr period over Africa. The data show a wide dynamic range of brightness temperature (180 to 290 K), corresponding to variations in surface features such as moisture, temperature, vegetation, roughness, and large-scale topography. It appears that soil moisture variability is detectable with the SMMR over large regions of Africa. To what extent roughness and vegetation affect this capability is not clear. The lowest SMMR frequency is C-band (6.6 GHz), thus any soil moisture sensitivity at this frequency would be much improved by a sensor at L-band (1 to 2 GHz) less affected by roughness and vegetation.

Njoku, Eni G.↗

Microphysics of the auroral acceleration region of other regions of the magnetosphere

Electric field and plasma measurements pertinent to the microphysics of the auroral acceleration region are reviewed. Observations in other regions of the magnetosphere, which appear to involve similar physical processes, are summarized in order to emphasize the requirement on Cluster instrumentation for wide dynamic range, high time resolution, time domain field, and particle measurements. It is suggested that the microphysics of current driven instabilities in the auroral acceleration region is duplicated in the high latitude boundary of the plasma sheet and that the macroscale structure of the tail is determined by this microphysics.

Mozer, F. S.↗

Phase Length Optical Phase-Locked-Loop Sensor

The invention is a device that provides a high resolution measurement of the change in optical phase length from the device optical system source to an optical reflector. The invention consists of a optical phase locked loop that uses a laser beam as a carrier of an intensity modulated energy source. The novelty of the invention appears to lie in the overall combination of elements which provide high resolution without loss of wide dynamic range. The invention does not depend on coherent reflection from a target, and thus can measure targets that do not have special preparation or corner reflectors. The use of carrier modulation achieves high resolution without the problems of high speed pulse duration systems. Thus the invention has the advantages of simplicity, low cost, and small size without sacrificing resolution.

Heyman, Joseph S.↗

The velocity structure and turbulence at the center of the Orion Nebula

Using the Coude Feed System of the Kitt Peak National Observatory at its highest possible dispersion and a CCD detector with wide dynamic range it was possible to examine in detail the radial and turbulent velocities of the Orion Nebula at the seeing limit. For the first time, multiple components of the spectral lines were resolved and the Gaussian profiles fit to them. Using four different observing runs, two circular areas 2 minutes in diameter were observed, the first centered on the theta sup 1 Orionis and the second centered on theta sup 2 Orionis. The velocity resolution of 1 km/s combined with the angular resolution of 2 seconds allowed observation in detail at line splitting as well as the location and measurement of high internal motions, about -50 km/s with respect to the bulk of ionized matter. Because over 900 different positions were measured, modern statistical techniques were used for the analysis of turbulence, so that the dispersion relation and the structure function could be calculated and compared with predictions of the Kolmogorov theory. The random motions showed correlation with spatial separation, as expected for turbulence; but comparison with predictions of the classical theory for nebular turbulence showed poor agreement. If Kolmogorov theory applies, then the energy must be input at many scales.

Castaneda, Hector O.↗

Preliminary results from the NASA/JPL multifrequency, multipolarization synthetic aperture radar

A brief description is given of the three-frequency polarimetric synthetic-aperture radar built and tested at the Jet Propulsion Laboratory. The radar has the capability to simultaneously acquire fully polarimetric data at P-, L-, and C-bands from a DC-8 airborne platform. The radar has an instantaneous data rate of approximately 2.1 Gb/s and has selectable record rates between 80-240 Mb/s. The system has a wide dynamic range featuring 8-b analog-to-digital converters and full digital floating-point processing. The processing is accomplished offline on a minicomputer system assisted by an array processor. Sample images are presented.

Held, Daniel N.↗

Spatial compression of Seasat SAR imagery

The results of a study of techniques for spatial compression of synthetic-aperture-radar (SAR) imagery are summarized. Emphasis is on image-data volume reduction for archive and online storage applications while preserving the image resolution and radiometric fidelity. A quantitative analysis of various techniques, including vector quantization (VQ) and adaptive discrete cosine transform (ADCT), is presented. Various factors such as compression ratio, algorithm complexity, and image quality are considered in determining the optimal algorithm. The compression system requirements are established for electronic access of an online archive system based on the results of a survey of the science community. The various algorithms are presented and their results evaluated considering the effects of speckle noise and the wide dynamic range inherent in SAR imagery. The conclusion is that although the ADCT produces the best signal-to-distortion-noise ratio for a given compression ratio, the two-level tree-searched VQ technique is preferred due to its simplicity of decoding and near-optimal performance.

Chang, C. Y.↗

The Hubble Space Telescope high speed photometer

The Hubble Space Telescope will provide the opportunity to perform precise astronomical photometry above the disturbing effects of the atmosphere. The High Speed Photometer is designed to provide the observatory with a stable, precise photometer with wide dynamic range, broad wavelenth coverage, time resolution in the microsecond region, and polarimetric capability. Here, the scientific requirements for the instrument are examined, the unique design features of the photometer are explored, and the improvements to be expected over the performance of ground-based instruments are projected.

Vancitters, G. W., Jr.↗

Theory and applications of optical fiber lever sensors

The evolution of optical fiber lever concepts is illustrated leading to several designs found useful in air and water applications. In particular, this technology has led to the development of underwater detectors of the pressure and pressure gradient kind. In addition, an optical microphone with features not found in condenser microphones has been utilized in the measurement of pressure fluctuations in high speed boundary layers requiring sensors of small size, extended bandwidth, wide dynamic range, and high temperature capability. Finally, similar concepts have been applied to the design of scale model acoustic arrays intended for acoustic imaging applications in the megahertz frequency range.

Cuomo, F. W.↗

Solid-state thin-film memistor for electronic neural networks

This paper reports on a tungsten-oxide-based, nonvolatile, electrically reprogrammable, variable resistance device as an analog synaptic memory connection for electronic neural networks. A voltage controlled, reversible injection of H(+) ions in electrochromic thin films of WO3 is utilized to modulate its resistance. A hygroscopic thin film of Cr2O3 is the source of H(+) ions. The resistance of the device can be tailored and stabilized over a wide dynamic range (about 4 orders of magnitude), and the programming speed is modulated by the control voltage. The suitability of such a device in terms of its response speed, reversibility, stability, and cyclability for its use in electronic neural networks is discussed.

Thakoor, S.↗

Vibration environment - Acceleration mapping strategy and microgravity requirements for Spacelab and Space Station

In order to define the acceleration requirements for future Shuttle and Space Station Freedom payloads, methods and hardware characterizing accelerations on microgravity experiment carriers are discussed. The different aspects of the acceleration environment and the acceptable disturbance levels are identified. The space acceleration measurement system features an adjustable bandwidth, wide dynamic range, data storage, and ability to be easily reconfigured and is expected to fly on the Spacelab Life Sciences-1. The acceleration characterization and analysis project describes the Shuttle acceleration environment and disturbance mechanisms, and facilitates the implementation of the microgravity research program.

Martin, Gary L.↗

Image gathering and digital restoration for fidelity and visual quality

The fidelity and resolution of the traditional Wiener restorations given in the prevalent digital processing literature can be significantly improved when the transformations between the continuous and discrete representations in image gathering and display are accounted for. However, the visual quality of these improved restorations also is more sensitive to the defects caused by aliasing artifacts, colored noise, and ringing near sharp edges. In this paper, these visual defects are characterized, and methods for suppressing them are presented. It is demonstrated how the visual quality of fidelity-maximized images can be improved when (1) the image-gathering system is specifically designed to enhance the performance of the image-restoration algorithm, and (2) the Wiener filter is combined with interactive Gaussian smoothing, synthetic high edge enhancement, and nonlinear tone-scale transformation. The nonlinear transformation is used primarily to enhance the spatial details that are often obscurred when the normally wide dynamic range of natural radiance fields is compressed into the relatively narrow dynamic range of film and other displays.

Huck, Friedrich O.↗

CARS Temperature Measurements in a Hypersonic Propulsion Test Facility

Nonintrusive diagnostic measurements were performed in the supersonic reacting flow of the Hypersonic Propulsion Test Cell 2 at NASA-Langley. A Coherent Anti-stokes Raman Spectroscopy (CARS) system was assembled specifically for the test cell environment. System design considerations were: (1) test cell noise and vibration; (2) contamination from flow field or atmospheric borne dust; (3) unwanted laser or electrically induced combustion (inside or outside the duct); (4) efficient signal collection; (5) signal splitting to span the wide dynamic range present throughout the flow field; (6) movement of the sampling volume in the flow; and (7) modification of the scramjet model duct to permit optical access to the reacting flow with the CARS system. The flow in the duct was a nominal Mach 2 flow with static pressure near one atmosphere. A single perpendicular injector introduced hydrogen into the flow behind a rearward facing step. CARS data was obtained in three planes downstream of the injection region. At least 20 CARS data points were collected at each of the regularly spaced sampling locations in each data plane. Contour plots of scramjet combustor static temperature in a reacting flow region are presented.

Jarrett, Olin, Jr.↗

High background photon counting lidar

Photon counting with lidar returns is usually limited to low light levels, while wide dynamic range is achieved by counting for long times. The broad emission spectrum of inexpensive high-power semiconductor lasers makes receiver filters pass too much background light for traditional photon counting in daylight. Very high speed photon counting is possible, however, at more than 500 MHz which allows the construction of eyesafe lidar operating in the presence of bright clouds. Detector improvements are possible to count to 20 GHz producing a single shot dynamic range of ten decades.

Lentz, W. J.↗

Lidar receivers for picosecond remote sensing

The lidars of picosecond resolution are an attractive tool for remote probing of some highly dynamic objects like sea subsurface waters, small-scale turbulences in the atmosphere, etc. The picosecond lasers are suitable illuminating sources, but the main restrictions are due to the lack of proper receiving methods, combining the both high temporal and amplitude resolution, good sensitivity, short integration time, and wide dynamic range. The methods for short pulse measurements are not suitable for picosecond lidars, operating at low level, with highly dynamic signals. The streak-cameras are of high cost, lower sensitivity, and lower dynamic range (approximately 10(exp 3)). Because of the background, the single quantum regime in photomultipliers (PMT) is ineffective. The sampling of highly dynamic optical signals with resolution less than or equal to 1ns is a serious problem, limiting the application of the high speed PMT-MCP (microchannel plate) in the picosecond lidar systems. The goal of this work is to describe the use of a new photodetection technique which combines the picosecond resolution with the high amplitude resolution, dynamic range, and sensitivity.

Stoyanov, D. V.↗