Search NASA⌕ Search

SEARCH · Search NASA

Results for “X RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

THE RADIATIVE X-RAY AND GAMMA-RAY EFFICIENCIES OF ROTATION-POWERED PULSARS

We present a statistical analysis of the X-ray luminosity of rotation-powered pulsars and their surrounding nebulae using the sample of Kargaltsev and Pavlov, and we complement this with an analysis of the {gamma}-ray emission of Fermi-detected pulsars. We report a strong trend in the efficiency with which spin-down power is converted to X-ray and {gamma}-ray emission with characteristic age: young pulsars and their surrounding nebulae are efficient X-ray emitters, whereas in contrast old pulsars are efficient {gamma}-ray emitters. We divided the X-ray sample in a young ({tau}{sub c} < 1.7 x 10{sup 4} yr) and old sample and used linear regression to search for correlations between the logarithm of the X-ray and {gamma}-ray luminosities and the logarithms of the periods and period derivatives. The X-ray emission from young pulsars and their nebulae are both consistent with L{sub X}{proportional_to} P-dot{sup 3}/P{sup 6}. For old pulsars and their nebulae the X-ray luminosity is consistent with a more or less constant efficiency {eta}{identical_to}L{sub X}/ E-dot{sub rot}{approx}8x10{sup -5}. For the {gamma}-ray luminosity we confirm that L{sub {gamma}} {proportional_to} {radical}E-dot{sub rot}. We discuss these findings in the context of pair production inside pulsar magnetospheres and the striped wind model. We suggest that the striped wind model may explain the similarity between the X-ray properties of the pulsar wind nebulae and the pulsars themselves, which according to the striped wind model may both find their origin outside the light cylinder, in the pulsar wind zone.

79 ASTRONOMY AND ASTROPHYSICS↗

Revealing structural evolution of PbS nanocrystal catalysts in electrochemical CO 2 reduction using in situ synchrotron radiation X-ray diffraction

We investigated the structural evolution of PbS catalysts under electrochemical CO 2 reduction reaction (eCO 2 RR) conditions using an in situ synchrotron radiation X-ray diffraction (SR-XRD) technique. The PbS catalyst with an initial form of size-tunable nanocrystals (NCs) performed efficiently in the electrochemical conversion of CO 2 to formate with a record-high mass activity (MA) of 52.2 ± 5.2 mA mg Pb -1 at -1.2 V and 74.9 ± 4.7 mA mg Pb -1 at -1.4 V vs. the reversible hydrogen electrode (RHE). In situ SR-XRD analyses revealed that PbS NCs underwent rapid structural transformation to Pb thin films during the eCO 2 RR, providing the real catalytic surface for the eCO 2 RR. Such a structural change is complex, with PbS first being converted to PbCO 3 and the latter species being further reduced to Pb. This work highlights the importance of understanding environmental impacts on the instability of nanocatalysts under eCO 2 RR conditions and the need for designing more robust electrocatalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The radiation-tolerant x-ray monitor

A vacuum photoelectric detector (monitor) (VPD) designed for plasma tomography, megnetohydrodynamics monitoring, and imaging with the help of thermal x-ray radiation on the ITER facility is described. Laboratory experiments demonstrate that VPD has high sensitivity to thermal x rays and low sensitivity to hard gamma rays and neutrons. The results of tests of a prototype of this monitor on a {sup 60}Co source of gamma rays, on nuclear reactor and its calibration using radiation from an x-ray tube, and tests of its serviceability on the T-10 facility are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-photon double ionization of atoms in attosecond x-ray radiation fields

We consider two-photon double ionization of helium with 100, 200, and 400 eV excess energy for the two ejected electrons, corresponding to photon energies of 89.5, 139.5, and 239.5 eV, respectively. We focus on the case of ultrashort pulses (two oscillations of the field) and develop an approach to calculate the two-photon transition matrix elements within the lowest order of the time-dependent perturbation theory. One of the major difficulties in calculating such amplitudes is the infinite summation over a complete set of intermediate states. In the subfemtosecond regime, however, this summation can be performed accurately by means of the closure approximation. This results in a simple expression for the two-photon amplitude that contains a dipole term and a quadrupole term. The dipole term can be clearly associated to a process in which each electron absorbs a photon whereas the quadrupole term is associated to a process in which one electron absorbs two photons and ejects the second one by collision. We analyze in detail how the relative weight of both processes influences the behavior of the electron energy and angular distributions. In particular we study how the shape of these distributions changes with the amount of electron correlations taken into account in both initial and final states. For 100 eV excess energy, our results for the electron energy distribution are compared with those obtained by solving the time-dependent Schroedinger equation. All these results unveil the crucial role of electron correlations in this transient regime of ionization which is neither sequential nor direct.

74 ATOMIC AND MOLECULAR PHYSICS↗

CaCO 3 Crystallite Evolution during CaO Carbonation: Critical Crystallite Size and Rate Constant Measurement by In-Situ Synchrotron Radiation X-ray Powder Diffraction

In this work, the evolution of the CaCO 3 crystalline phase during the CaO–CO 2 reaction was investigated by means of in situ synchrotron radiation X-ray powder diffraction performed at the Advanced Photon Source (APS) facilities of the Argonne National Laboratory. CO 2 absorption experiments were carried out in a high temperature reaction capillary with a controlled atmosphere of pure carbon dioxide (CO 2 partial pressure of 1 bar) and in the temperature range between 450 and 750 °C, using CaO-based sorbents obtained by calcination of commercial calcium carbonate. The Rietveld refinement method was applied to estimate the average size of the CaCO 3 crystallites formed during a carbonation time of 20 min, as a function of the carbonation temperature and of the initial calcination conditions. Local maxima were observed in the CaCO 3 crystallite size versus time curves and were identified as the critical CaCO 3 crystallite sizes, marking the transition between the first fast carbonation stage and the second reaction stage controlled by product-layer diffusion. A relationship between this parameter and the reaction temperature, as well as with the initial (at the beginning of carbonation) CaO crystallite size, were found. The CaCO 3 critical crystallite sizes were used to estimate the active surface areas of the CaO sorbent particles where CaCO 3 crystals form and grow. Here, the computed active surface areas were utilized to calculate the kinetic parameters of the surface carbonation reaction: a reaction rate constant of 4.41 × 10 –4 mol/m 2 s, with zero-activation energy, was obtained.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of Soft X-Ray Radiation in a Compact Free-Electron Laser with Harmonic Multiplication

Single-pass free-electron lasers (FELs) with harmonic multiplication in the X-ray range are studied theoretically with the objective of producing intense radiation with the minimum possible FEL length, beam energy, and seed laser frequency. A cascade FEL with a two-frequency undulator for electron bunching at wavelengths of higher harmonics is proposed. The dynamics of radiation power in a FEL with harmonic multiplication cascades is investigated based on a well-proven phenomenological FEL model that covers all major losses for each harmonic in each FEL cascade. The effect of the beam quality on X-ray generation in a FEL is examined. It is demonstrated that electron beams with energy spread σ{sub e} ≤ 0.0002 are required for efficient use of harmonics in a cascade X-ray FEL. The evolution of power of harmonics in several cascade FELs at wavelengths of ~2–3 nm with multiplication of seed harmonics at a wavelength of 13.51 nm (Mo/Si reflection peak) and 11.43 nm (MoRu/Be reflection peak) is studied. It is demonstrated that the power increases to ~1 GW at a FEL length up to 40 m. In addition, the operation of multicascade FELs with a seed F{sub 2} excimer 157-nm UV laser and harmonics of lasers with CO{sub 2} and C{sub 2}H{sub 2} at 30 nm with a beam of electrons with an energy of ~0.6 GeV and a current of ~1 kА is studied. The power of the modeled X-ray radiation of these FELs at λ = 2.5 and 3.3 nm increases to ~0.5 GW at ~30 m.

43 PARTICLE ACCELERATORS↗

Synchrotron Vacuum Ultraviolet Light and Soft X-Ray Radiation Effects on Aluminized Teflon FEP Investigated

Since the Hubble Space Telescope (HST) was deployed in low Earth orbit in April 1990, two servicing missions have been conducted to upgrade its scientific capabilities. Minor cracking of second-surface metalized Teflon FEP (DuPont; fluorinated ethylene propylene) surfaces from multilayer insulation (MLI) was first observed upon close examination of samples with high solar exposure retrieved during the first servicing mission, which was conducted 3.6 years after deployment. During the second HST servicing mission, 6.8 years after deployment, astronaut observations and photographic documentation revealed significant cracks in the Teflon FEP layer of the MLI on both the solar- and anti-solar-facing surfaces of the telescope. NASA Goddard Space Flight Center directed the efforts of the Hubble Space Telescope MLI Failure Review Board, whose goals included identifying the low-Earth-orbit environmental constituent(s) responsible for the cracking and embrittling of Teflon FEP which was observed during the second servicing mission. The NASA Lewis Research Center provided significant support to this effort. Because soft x-ray radiation from solar flares had been considered as a possible cause for the degradation of the mechanical properties of Teflon FEP (ref. 1), the effects of soft xray radiation and vacuum ultraviolet light on Teflon FEP were investigated. In this Lewisled effort, samples of Teflon FEP with a 100-nm layer of vapor-deposited aluminum (VDA) on the backside were exposed to synchrotron radiation of various vacuum ultraviolet and soft x-ray wavelengths between 18 nm (69 eV) and 0.65 nm (1900 eV). Synchrotron radiation exposures were conducted using the National Synchrotron Light Source at Brookhaven National Laboratory. Samples of FEP/VDA were exposed with the FEP surface facing the synchrotron beam. Doses and fluences were compared with those estimated for the 20-yr Hubble Space Telescope mission.

Dever, Joyce A.↗

Polarization Studies of CdZnTe Detectors Using Synchrotron X-ray Radiation

High densities of impurities and defects lead to severe charge-carrier trapping that can be major issues in assuring the high performance of CZT detectors. For some medical-imaging applications, the typical X-ray flux can be very high. Under such high irradiation conditions, the trapped charge builds up inside the detector affecting its stability. This phenomenon generally is termed the polarization effect. We conducted detailed studies on polarization in CZT crystals employing a highly collimated synchrotron X-ray radiation source available at Brookhaven's National Synchrotron Light Source (NSLS). We were able to induce polarization effects by irradiating specific areas within the detector. These measurements allowed us to make, for the first time, a quantitative comparison between areas where polarization is induced, and the electron- and hole-collection X-ray maps obtained at low flux, where no polarization is induced. We discuss the results of these polarization studies.

43 PARTICLE ACCELERATORS↗

Non-thermal fluence threshold for femtosecond pulsed x-ray radiation damage in perovskite complex oxide epitaxial heterostructures

Intense hard x-ray pulses from a free-electron laser induce irreversible structural damage in a perovskite oxide epitaxial heterostructure when pulse fluences exceed a threshold value. The intensity of x-ray diffraction from a 25-nm thick epitaxial BiFeO 3 layer on a SrTiO 3 (STO) substrate measured using a series of pulses decreases abruptly with a per-pulse fluence of 2.7 x 10(6) photons mu m -2 at a photon energy of 9.7 keV but remains constant for 1.3 x 10 6 photons mu m -2 or less. The damage resulted in the destruction of the BiFeO 3 thin film within the focal spot area and the formation of a deep cavity penetrating into the STO substrate via the removal of tens of nanometers of material per pulse. The damage threshold occurs at a fluence that is insufficient to heat the absorption volume to the melting point. The morphology of the ablated sample is consistent with fracture rather than melting. Together, these results indicate that the damage occurs via a nonthermal process consistent with ultrafast ionization of the absorption volume.

36 MATERIALS SCIENCE↗

CdTe Timepix detectors for single-photon spectroscopy and linear polarimetry of high-flux hard x-ray radiation

Single-photon spectroscopy of pulsed, high-intensity sources of hard X-rays — such as laser-generated plasmas — is often hampered by the pileup of several photons absorbed by the unsegmented, large-volume sensors routinely used for the detection of high-energy radiation. Detectors based on the Timepix chip, with a segmentation pitch of 55 μm and the possibility to be equipped with high-Z sensor chips, constitute an attractive alternative to commonly used passive solutions such as image plates. In this report, we present energy calibration and characterization measurements of such devices. The achievable energy resolution is comparable to that of scintillators for γ spectroscopy. Moreover, we also introduce a simple two-detector Compton polarimeter setup with a polarimeter quality of (98 ± 1)%. Finally, a proof-of-principle polarimetry experiment is discussed, where we studied the linear polarization of bremsstrahlung emitted by a laser-driven plasma and found an indication of the X-ray polarization direction depending on the polarization state of the incident laser pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intermolecular correlations of liquid and glassy CS 2 studied by synchrotron radiation x-ray diffraction

How is the orientation of molecular liquids ordered on cooling? What are the basic structures of molecular glasses, e.g., close to the crystalline structure or some special structures such as icosahedral cluster? These are long-standing questions in liquid and glass physics. Here, we have constructed a novel cryostat to prepare simple molecular glasses by vapor deposition and performed in situ synchrotron radiation x-ray diffraction experiments. The glassy state of a simple molecule CS 2 , which cannot be vitrified by normal liquid quenching, was successfully prepared with this instrument, and its diffraction data were collected in a wide Q-range of 0.16–25.7 Å -1 with a high-energy diffractometer at BL04B2, SPring-8. The diffraction data of liquid CS 2 were also recorded in a wide temperature range of 160–300 K. These diffraction data were analyzed with molecular dynamics simulations and reverse Monte Carlo modelings to investigate orientational correlation. From the obtained 3D structure models, the orientational correlation between neighboring CS 2 molecules was investigated quantitatively as a function of temperature. At room temperature, the parallel and T-shaped arrangements are preferred for the nearest neighbor correlation. On cooling, these arrangements are developed gradually, and its rate became prominent below the melting temperature (162 K). In the glassy state, the slipped-parallel arrangement is dominant as well as the T-shaped arrangement. Both arrangements appear in the CS 2 crystal, indicating that the structure of glassy CS 2 is close to that of crystalline CS 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Double-Crystal Rocking Curve Simulation Using 2D Spectral Angular Diagrams of X-Ray Radiation

A new approach to numerical simulation of double-crystal rocking curves is proposed. This approach is based on the use of experimental spectral angular diagrams of X-ray intensity distribution. Special calculation algorithms, which take into account the instrumental function of X-ray diffractometer and possible effects of dispersion and Bragg reflection asymmetry, have been developed and applied. A specific feature of the proposed approach is the possibility of visualizing the 2D spectral angular diagram of X-ray beam after its interaction with each element of the scheme. The approach makes it possible to perform calculations for a wide range of radiation sources (from an X-ray tube with any anode to a synchrotron radiation source) and X-ray optical elements (slits and monochromators). A comparison of simulation results and experimental data for a Si(110) crystal sample has confirmed adequacy of the proposed approach and its applicability for simulating diffraction patterns recorded in real experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Copper uptake, intracellular localization, and speciation in marine microalgae measured by synchrotron radiation X-ray fluorescence and absorption microspectroscopy

Metal toxicity to aquatic organisms depends on the speciation of the metal and its binding to the critical receptor site(s) (biotic ligand) of the organism. The intracellular nature of the biotic ligand for Cu in microalgal cells was investigated using the high elemental sensitivity of microprobe synchrotron radiation X-ray fluorescence (SR-XRF) and X-ray absorption near-edge spectroscopy (XANES). The marine microalgae, Ceratoneis closterium , Phaeodactylum tricornutum , and Tetraselmis sp. were selected based on their varying sensitivities to Cu (72-h 50% population growth inhibitions of 8–47 μg Cu/L). Intracellular Cu in control cells was similar for all three species (2.5–3.2 × 10–15 g Cu/cell) and increased 4-fold in C. closterium and Tetraselmis sp. when exposed to copper, but was unchanged in P. tricornutum (72-h exposure to 19, 40, and 40 μg Cu/L, respectively). Whole cell microprobe SR-XRF identified endogenous Cu in the central compartment (cytoplasm) of control (unexposed) cells. After Cu exposure, Cu was colocated with organelles/granules dense in P, S, Ca, and Si and this was clearly evident in thin sections of Tetraselmis sp. XANES indicated coexistence of Cu(I) and Cu(II) in control and Cu-exposed cells, with the Cu ligand (e.g., phytochelatin) in P. tricornutum different from that in C. closterium and Tetraselmis sp. Here, this study supports the hypothesis that Cu(II) is reduced to Cu(I) and that polyphosphate bodies and phytochelatins play a significant role in the internalization and detoxification of Cu in marine microalgae.

54 ENVIRONMENTAL SCIENCES↗

X-ray radiation effects in multilayer epitaxial graphene

We characterize multilayer graphene grown on C-face SiC before and after exposure to a total ionizing dose of 12 Mrad(SiO{sub 2}) using a 10 keV x-ray source. While we observe the partial peeling of the top graphene layers and the appearance of a modest Raman D-peak, we find that the electrical characteristics (mobility, sheet resistivity, free carrier concentration) of the material are mostly unaffected by radiation exposure. Combined with x-ray photoelectron spectroscopy data showing numerous carbon-oxygen bonds after irradiation, we conclude that the primary damage mechanism is through surface etching from reactive oxygen species created by the x-rays.

36 MATERIALS SCIENCE↗

Effect of X-Ray Radiation on the Optical Properties of Photorefractive Bismuth-Silicate Crystals

The results of investigations of the optical-absorption spectra of bismuth-silicate (Bi{sub 12}SiO{sub 20}) single crystals are presented. The band-gap width and the characteristic Urbach energy are determined. The effect of preliminary X-ray irradiation on the behavior of the experimental spectral dependences and the values of the characteristic parameters induced by the bismuth-silicate defect structure is established.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

(Cd,Mg)Te crystals for picosecond-response optical-to-x-ray radiation detectors

We demonstrate a photodetector sensitive to both optical and x-ray picosecond pulses based on our in-house grown cadmium magnesium telluride (Cd,Mg)Te single crystal. Specifically, we developed In-doped Cd0.96Mg0.04Te material and discuss its femtosecond optical photoresponse, as well as the detector performance, such as <100-pA dark current and up to 0.22-mA/W responsivity for 780-nm wavelength optical radiation. The detector exposed to Ti fluorescence (K alpha) x-ray pulses at 4.5 keV, generated by a free-electron laser beam with the central energy of 9.8 keV and <100 fs pulse width, exhibited readout-electronics-limited 200-ps full-width-at-half-maximum photoresponse, demonstrating that it is suitable for coarse timing in free-electron laser x-ray/optical femtosecond pump–probe spectroscopy applications.

Instruments & Instrumentation↗

Bone Implant Interface Investigation by Synchrotron Radiation X-Ray Microfluorescence

Zinc is known to play a relevant role in growth and development; it has stimulatory effects on in vitro and in vivo bone formation and an inhibitory effect on in vitro osteoclastic bone resorption. The inorganic component of the bone tissue is nonstoichiometric apatite; changes in the composition of hidroxyapatite are subject of studies in order to improve the tissue response after implantation. The objective of this study was to investigate the effect of 0.5% zinc-containing hydroxyapatite in comparison to hydroxyapatite on osseous repair of rabbit's tibia. Cylinders (2x6 mm) of both materials were produced according to the specification of the International Organization for Standardization. Ethics Commission on Teaching and Research in Animals approved this project (HUAP-195/06). Fifteen White New Zealand rabbits were submitted to general anesthesia and two perforations (2 mm) were made in each tibia for implantation of zinc-containing hydroxyapatite cylinders (left tibia) and hydroxyapatite cylinders (right tibia). After 1, 2 and 4 weeks, the animals were killed and one fragment of each tibia with the cylinder was collected and embedded in a methacrylate-based resin and cut into slices (approx200 {mu}m thickness), parallel to the implant's long axis with a precision diamond saw for Synchrotron Radiation X-ray Microfluorescence investigation. The accomplishment of the standard procedures helped the planning, execution and the comparative analysis of the results. The chemical and physical properties of the biomaterials were modified after its implantation and the incorporation of zinc. Both materials are biocompatible and promote osteoconduction and favored bone repair.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗