Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray beams & optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Determination of the efficiency of a proportional counter for detecting X-rays

A parallel beam of X-rays (approximately monoenergetic) passing through a rectangular slit and scattering from two flat mirrors comprise the X-ray test. The two mirrors are arranged in a periscope geometry so that the final reflected beam is parallel to the incident beam but displaced laterally by given amount. One of the detectors used to intercept the reflected X-rays is a one dimensional gas-filled proportional counter which is sensitive to the position (in 1 dimension) at which the X-rays are incident within its detecting "window". The total length of the anode wire of the proportional counter is 120 mm and this length can be divided electronically into a maximum of 1,024 parts. Hence, the output of an experimental run would be the number of incident X-rays that registered on each of the 1,024 channels. Each channel would represent an X-ray at a different spatial location and, hence, at a different scattering angle. In order to look at a wider range of scattering angles, the detector is placed on an optical table which can be rotated.

Williams, A. C.↗

Quantifying uncertainty in uranium concentration measurements via K-edge densitometry

This study quantifies the uncertainty in uranium concentration predictions of fluoride and chloride-based salts within a steel pipe using K-edge densitometry. Modeling and simulation was conducted with the Monte Carlo N-Particle Transport (MCNP) code. The quality of of this technique’s prediction in a pipe requires proper characterization of the pipe’s thickness, which is dependent on the source size and axial offset from the pipe centerline. The thickness was determined as either the center-line thickness seen by the X-ray source or an average value determined through random sampling. Generally, the predicted concentrations were slightly better at lower offset with the random sampling thickness and using the center-line thickness for the highest offsets. For a line-beam source and varying axial offsets, the relative error of concentration was within 1% of the true value but uncertainty increased by 2 orders of magnitude. Similarly, for no axial offset, the relative error was significantly less than 1% while no trend for uncertainty was found. However, at the largest possible offset for a given source size, the concentrations become erroneous and greater than the allowable 1% relative error. Furthermore, high offsets tended to increase the variance of the transmission spectra by 3 orders of magnitude.

Characterization and Analytical Technique↗

Optical imaging spectroscopy

During the recent solar maximum the combination of imaging and spectroscopy in the visible part of the spectrum became a powerful tool for observational study of flares primarily because of the development of two-dimensional charge-coupled-device (CCD) arrays. In combination with appropriate new operational methods, this has led to the ability to observe, for the first time, the preflare and impulsive-phase physical processes associated with spatially resolved features of flare loops. As a result of concurrent theoretical developments, modeling progressed from an empirical to a physical level. This made it possible to interpret imaging spectra in terms of coronal pressure and heat flux, particle beam heating, chromospheric evaporation, and explosive chromospheric dynamics at the footpoints of flare loops. There is clear potential for further advances in the near future, taking advantage of improvements in digital recording speed (approx. 10-fold), number of photosensitive elements per array (approx. 10-fold), real-time data pre-reduction (potentially 10- to 100-fold), and using multiple CCD arrays. By the time of the next solar maximum imaging spectroscopy is expected to achieve spatial resolution or approx. arc 1 arc s, temporal resolution or approx. 5 s, and simultaneous critically-sampled spectroscopy of several lines and continua. As a result, continued increase in our understanding of the physical processes and configurations of solar flares in the chromosphere, temperature minimum region, and photosphere can be anticipated. Even greater progress toward a more global understanding of flares will obviously come about when simultaneous optical, X-ray, and gamma-ray imaging spectroscopy are possible.

Canfield, R. C.↗

Evidence of electron microbunching in laser-driven modulated downramp injection and prospects for beam-driven implementation

Plasma accelerators can generate high-energy, high-brightness electron beams over centimeter-scale distances, offering novel pathways to compact x-ray free-electron lasers. Generating beams pre-bunched at the desired radiation wavelength would significantly enhance longitudinal coherence and reduce saturation length. Plasma density-modulated downramp injection offers an in-situ way to generate such beams with nanometer-scale bunching. Here we report the first experimental evidence of this mechanism in a laser-driven wakefield accelerator, showing that modulated density downramps generate modulated electron energy spectra absent in unmodulated cases. Particle-in-cell simulations reproduce these observations and reveal bunching factors of 0.05 at 0.4 μm, with a compression factor of approximately 7. Building on this demonstration, we propose a beam-driven implementation for FACET-II to generate multi-GeV beams pre-bunched at hundreds of nanometers wavelength, with sub-micrometer emittance, kiloampere peak current, and sub-percent slice energy spread. Two-stage magnetic compression enables tunable bunching from optical to extreme ultraviolet wavelengths while achieving peak currents exceeding 100 kA. Coherent transition radiation calculations confirm diagnostic feasibility. This approach offers a promising path towards compact, high-energy pre-bunched electron sources for advanced photon science applications.

electron microbunching↗

Evaluating Brightness and Stability of Cathodoluminescence from Colloidal Semiconductor Nanocrystals

Cathodoluminescence offers promise as a technique for correlation of atomic structure with electronic structure at the level of individual nanoparticles or even defects, with the ability to analyze complex nanostructures at length-scales far below those typically available to optical spectroscopy. Unlike other forms of electron microscopy, cathodoluminescence offers direct insights into the electronic structure of the visualized sample. Despite reports more than 10 years ago of individual nanoparticle cathodoluminescence, effective cathodoluminescence collection from colloidal semiconductor materials is relatively rare and remains challenging due to the instability of materials under the conditions of electron beam irradiation. In this work, to clarify the roadblocks for cathodoluminescence analysis of colloidal nanocrystals, we attempt a comprehensive study of the cathodoluminescence properties of semiconductor quantum shells, which have a thin concentric CdSe shell surrounding CdS nanoparticles, then surrounded by a further concentric CdS shell. These same materials were recently demonstrated to show promising scintillation performance in radioluminescence measurements, including high brightness (up to 100 ph/keV) and excellent durability. Comparative quantum yield measurements are designed to assess the brightness of semiconductor nanocrystal films, which show that the quantum shells are much less bright under electron irradiation compared to X-ray photons. Instability of CL emission is assigned to charging effects on the samples—and not thermal effects—through a series of voltage, current, dwell time, and atmospheric pressure experiments.

cathodoluminescence↗

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects↗

Accurate measurement of porosity size and morphology in aluminium alloy laser welds

Conventional two-dimensional optical microscopy is the most common tool for capturing and quantifying keyhole collapse porosity and other defects formed during the laser welding of aluminium alloys. This approach is of limited utility since only a single longitudinal or transverse metallographic cross-section, comprising only a small fraction of the overall weld volume, can be extracted or analysed at a time. X-ray computed tomography tools, on the other hand, enable three-dimensional visualisation and analysis of porosity and defects to be made across the full weld volume. When comparing these two measurement techniques, two-dimensional microscopy tools significantly underestimated the fraction of defects present within the weld at levels between 50% and 80%. Three-dimensional x-ray computed tomography tools also provide a means for accurately characterising the location, size and morphology of irregularly shaped defects. By categorising the defect shapes using a Zingg's shape analysis, in which the distribution of defect morphologies could be quantified as disk, rod and spherical shapes, a transition in defect morphology moving from stationary beam to oscillating beam welds was detected and quantified.

36 MATERIALS SCIENCE↗

Advanced optical instruments technology

The science objectives for proposed NASA missions for the next decades push the state of the art in sensitivity and spatial resolution over a wide range of wavelengths, including the x-ray to the submillimeter. While some of the proposed missions are larger and more sensitive versions of familiar concepts, such as the next generation space telescope, others use concepts, common on the Earth, but new to space, such as optical interferometry, in order to provide spatial resolutions impossible with other concepts. However, despite their architecture, the performance of all of the proposed missions depends critically on the back-end instruments that process the collected energy to produce scientifically interesting outputs. The Advanced Optical Instruments Technology panel was chartered with defining technology development plans that would best improve optical instrument performance for future astrophysics missions. At this workshop the optical instrument was defined as the set of optical components that reimage the light from the telescope onto the detectors to provide information about the spatial, spectral, and polarization properties of the light. This definition was used to distinguish the optical instrument technology issues from those associated with the telescope, which were covered by a separate panel. The panel identified several areas for optical component technology development: diffraction gratings; tunable filters; interferometric beam combiners; optical materials; and fiber optics. The panel also determined that stray light suppression instruments, such as coronagraphs and nulling interferometers, were in need of general development to support future astrophysics needs.

Shao, Mike↗

Particle Beam Acceleration Using 3 Petawatt Laser Pulses

The Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) is presently operational at the Gerard Mourou Center for Ultrafast Optical Science (CUOS) at the University of Michigan. ZEUS is a significant upgrade of the previous high power laser systems at CUOS and consists of two beamlines thatoperate in perfect synchronization. The 500 TW beamline became operational in 2023, 2 PW operation started in 2025 and full 3 PW power levels will be available in 2026. It is presently the highest power laser system in the US. In this grant the high field science group at CUOS has leveraged this unique high power laser facility to investigate laser wake field acceleration (LWFA) in ultra-high power laser plasma interactions and have shown how this can scale for future electron–positron colliders at high energy. The dual beam experimental configuration enables flexibility for many frontier experiments in laser-driven acceleration research, in particular, enabling extended channelling/acceleration experiments, positron generation/acceleration experiments and proof-of-principle transverse pumping “dephasingless” electron acceleration experiment and theory. LWFA may be able to miniaturize particle accelerators for high energy physics and also enable new sources of ultrafast, extreme brightness and precise x-rays for a wide variety of applications. In laser wake field acceleration, an electron bunch “surfs” on the electron plasma wave (the “wake field”) generated by the ponderomotive force of an intense laser. The plasma wave has a strong longitudinal electric field that stays in phase with the relativistic driver. A relativistic charged particle may, therefore, remain in phase with the accelerating field over long distances and gain ultra-relativistic energies. The accelerating electric field strength that the plasma wave can support can be many orders of magnitude higher than that of conventional accelerators, which makes laser wakefield acceleration an exciting prospect as an advanced accelerator concept. In this research project we have investigated the scaling of this mechanism to laser powers of 2 PW and have measured the x-ray emission and radio frequency emission resulting from the acceleration process. We have also performed theoretical investigation of mechanisms to scale laser driven accelerators to much higher energy using dephasingless acceleration processes.

43 PARTICLE ACCELERATORS↗

Use of particle beams for lunar prospecting

A key issue in choosing the appropriate site for a manned lunar base is the availability of resources, particularly oxygen and hydrogen for the production of water, and ores for the production of fuels and building materials. NASA has proposed two Lunar Scout missions that would orbit the Moon and use, among other instruments, a hard X-ray spectrometer, a neutron spectrometer, and a Ge gamma ray spectrometer to map the lunar surface. This passive instrumentation will have low resolution (tens of kilometers) due to the low signal levels produced by natural radioactivity and the interaction of cosmic rays and the solar wind with the lunar surface. This paper presents the results of a concept definition effort for a neutral particle beam lunar mapper probe. The idea of using particle beam probes to survey asteroids was first proposed by Sagdeev et al., and an ion beam device was fielded on the 1988 Soviet probe to the Mars moon Phobos. During the past five years, significant advances in the technology of neutral particle beams (NPB) have led to a suborbital flight of a neutral hydrogen beam device in the SDIO-sponsored BEAR experiment. An orbital experiment, the Neutral Particle Beam Far Field Optics Experiment (NPB-FOX) is presently in the preliminary design phase. The development of NPB accelerators that are space-operable leads one to consider the utility of these devices for probing the surface of the Moon using gamma ray, X-ray, and optical/UV spectroscopy to locate various elements and compounds. We consider the utility of the NPB-FOX satellite containing a 5-MeV particle beam accelerator as a probe in lunar orbit. Irradiation of the lunar surface by the particle beam will induce secondary and back scattered radiation from the lunar surface to be detected by a sensor that may be co-orbital with or on the particle beam satellite platform, or may be in a separate orbit. The secondary radiation is characteristic of the make-up of the lunar surface. The size of the spot irradiated by the beam is less than 1 km wide along the ground track of the satellite, resulting in the potential for high resolution. The fact that the probe could be placed in polar orbit would result in global coverage of the lunar surface. The orbital particle beam probe could provide the basis for selection of sites for more detailed prospecting by surface rovers.

Toepfer, A. J.↗

Molecular beam epitaxy of superconducting zirconium nitride on GaN substrates

Epitaxial integration of metals and semiconductors can enable enhanced performance and novel functionality. Achieving such pristine interfaces with superconducting materials is of increasing interest for quantum devices and detectors, but the experimental demonstration remains challenging, given the very limited studies on single crystalline systems. To expand the potential materials for these systems, this work explores the deposition of zirconium nitride superconducting thin films on GaN substrates at various temperatures using molecular beam epitaxy. A general trend of decreasing superconducting critical temperature is observed as the deposition temperature is reduced. The optical properties reveal a transition from metallic to dielectric behavior with colder deposition. The plasma frequency of the metallic films is also observed to be a function of growth temperature. These results pave the way for the integration of a highly tunable metal nitride with a well-established semiconductor system.

36 MATERIALS SCIENCE↗

Errors in reconstruction of dichroic X-ray orientation tomography due to polarization rotation of the incident beam

Dichroic X-ray tomography is a technique in which the crystal orientation or magnetization of a sample is resolved in three dimensions. The best-known uses of this technique are for observation of magnetic moments via circular dichroism, using left- and right-handed circularly polarized X-ray beams. Another variant uses linear dichroism to resolve the crystal orientation. In both these techniques, it is assumed that the absorption of X-rays along a path inside a material can be computed as a line integral of a local absorption coefficient along the ray path. For linear dichroism, this assumption is inaccurate because the polarization of the beam changes along the propagation direction when the optic axis of the material is not aligned along the polarization. In this work, a finite-element Maxwell solver is used to simulate tomography and reconstructions. The propagation effect can lead to significant errors in the reconstructed orientations. These errors may be mitigated by taking data at additional angles or by operating at energies at which the dichroism is weak. An iterative approach is proposed which may allow accurate reconstruction with fewer data than would otherwise be required.

X-ray linear dichroism↗

The importance of shear on the collective charge transport in CDWs revealed by an XFEL source

Charge transport in materials has an impact on a wide range of devices based on semiconductor, battery, or superconductor technology. Charge transport in sliding charge density waves (CDW) differs from all others in that the atomic lattice is directly involved in the transport process. To obtain an overall picture of the structural changes associated to the collective transport, the large coherent x-ray beam generated by an x-ray free-electron laser (XFEL) source was used. The CDW phase can be retrieved over the entire sample from diffracted intensities using a genetic algorithm. For currents below threshold, increasing shear deformation is observed in the central part of the sample while longitudinal deformation appears above threshold when shear relaxes. Shear thus precedes longitudinal deformation, with relaxation of one leading to the appearance of the other. Moreover, strain accumulates on surface steps in the sliding regime, demonstrating the strong pinning character of these surface discontinuities. The sliding process of nanometric CDW involves macroscopic sample dimensions.

36 MATERIALS SCIENCE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Impact of Arsenic- and Indium-Terminated InGaAs Stressors on Carrier Confinement, Strain, Defects, and Transport Properties of Tensile-Strained Ge

Device-quality tensile-strained Ge (ε-Ge) grown on a large bandgap semiconductor with superior electrical and optical carrier confinement is essential for group-IV-based optoelectronics. Properties of ε-Ge active layers synthesized on In 0.24 Ga 0.76 As buffers with two different surface terminations─arsenic-rich and indium-rich─were experimentally demonstrated, highlighting the factors not considered in theoretical calculations. High-resolution X-ray diffraction and Raman spectroscopy analyses of these ε-Ge/In 0.24 Ga 0.76 As heterostructures confirmed the fully strained (1.6%) and partially relaxed (0.82%) nature of the ε-Ge bonded with arsenic-terminated (Ge As-terminated ) and indium-terminated (Ge In-terminated ) In 0.24 Ga 0.76 As stressors, respectively. High-resolution cross-sectional transmission electron microscopy showed a coherent, sharp, and fully strained ε-Ge/In 0.24 Ga 0.76 As heterointerface in the Ge As-terminated heterostructure, whereas microtwin defects were present in the Ge In-terminated heterostructure. These heterostructures were further characterized by evaluating the minority carrier lifetimes, high for Ge As-terminated (525 ns) and low for Ge In-terminated (69 ns), using the photoconductive decay technique. Moreover, band alignment was constructed using X-ray photoelectron spectroscopy, where the Ge As-terminated heterostructure revealed that both holes and electrons were confined within the ε-Ge active layer as a type-I band alignment with ΔE V, As-terminated = 0.22 eV and ΔE C,As-terminated = 0.38 eV. On the other hand, the Ge In-terminated heterostructure exhibited a type-II band alignment with ΔE V,In-terminated = – 0.02 eV and ΔE C,In-terminated = 0.53 eV. Furthermore, the magnetotransport properties revealed high mobility (321 cm 2 /(V s)) with single-electron transport in Ge As-terminated heterostructure and low mobility (3.34 cm 2 /(V s)) with multihole transport in the Ge In-terminated heterostructure. Therefore, preferring the ε-Ge on the arsenic-rich surface of In 0.24 Ga 0.76 As stressor over the indium-rich surface during material synthesis offers device-quality materials with high carrier lifetime and superior carrier confinement, which can provide an opportunity to fabricate efficient group-IV-based optoelectronic devices.

36 MATERIALS SCIENCE↗

Workshop on Impulsive Solar Flares, 2nd, University of New Hampshire, Durham, Sept. 26-28, 1988, Proceedings

Papers on impulsive solar flares are presented, covering topics such as the optical properties of impulsive flares, soft X-ray spectroscopy of solar flares, the energy release process in impulsive bursts, high-velocity evaporation and a high-speed shock wave during the impulsive phase of the April 24, 1984 flare, nonpotential magnetic fields at sites of gamma-ray flares, and meter-decimeter and microwave radio observations of solar flares. Other topics include rise times in solar radio bursts, removal of the gradual component in analyses of solar impulsive bursts, ion and relativistic electron transport in solar flares, neutrons and gamma-ray emission on June 3, 1982, emission characteristics of three intense solar flares in cycle 21, and solar flare gamma-ray observations with the Hinotori satellite. Additional topics include spectra of relativistic solar proton ground-level events recorded in Antarctica, a 153-d periodicity in the occurrence of solar flares producing energetic interplanetary electrons, a search for solar neutron response in neutron monitor data, neutral beams in two-ribbon flares and in the geomagnetic tail, beam heating in solar flares, and solar flare gamma-ray line shapes.

Source record↗

Fanaroff-Riley I galaxies as the parent population of BL Lacertae objects. II - Optical constraints

The hypothesis is investigated that BL Lacertae objects are a subset of Fanaroff-Riley (FR) I galaxies dominated by beamed emission from a relativistic jet aligned with the line of sight. It is found that FR I galaxies, although of low radio luminosity, are bright optical galaxies. If the beaming hypothesis is correct, the optical luminosity function of BL Lac objects, including the effect of the host galaxy, can be approximated by a double power law with a given differential index. New estimates of the number counts of BL Lac objects are made which constrain their local number density for L(B) greater than about 6 x 10 to the 43rd ergs/s to be in the range 110-720/cu Gpc. The corresponding ratio between the total number densities of BL Lac objects and FR I galaxies is 0.003 to 0.02. This limits the Lorentz factor of the optical emission to the range 8-20, larger than that of the X-ray emitting plasma and roughly of the same order as the radio Lorentz factor.

Padovani, Paolo↗

The growth and characterization of Al(x)Ga(1-x)As/Ge heterostructures

The effects of the growth temperature and the Al(x)Ga(1-x)As layer thickness on the structural, optical, and electrical properties of Al(x)Ga(1-x)As/Ge heterostructures grown for photovoltaic applications were investigated using different-thickness (between 1 micron and 5 microns) Al(x)Ga(1-x)As layers grown by MOCVD in the temperature range between 660 and 780 C. Results obtained from double-crystal X-ray rocking curve measurements, electron beam induced current, cross-sectional TEM, Raman spectroscopy, SIMS, and steady-state and time-resolved photoluminescence measurements are presented. It was found that the highest minority carrier lifetime, 2.41 ns, was obtained for T(G) = 780 C, but the lowest interfacial recombination velocity, 1.6 x 10 exp 4, was obtained at 660 C.

Choi, S. W.↗