Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray fluorescence (XRF)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advances in X-ray Instruments to Support Mars Sample Return

The Mars 2020 Perseverance rover is currently collecting drill cores of ancient igneous and sedimentary rock in and around Jezero crater for potential transport to Earth. These samples from the martian surface will enable detailed mineralogical, geochemical, and petrological measurements to characterize ancient depositional and diagenetic environments, quantitatively age-date the samples, and identify the building blocks for life or evidence for life itself. Furthermore, these drill cores are especially precious because they may represent the most pristine samples from the martian surface and our best chance at identifying martian life, as future sample return missions may be conducted by humans that can introduce biological contaminants to the samples. Because of the importance of these samples, we must take great care in their handling, curation, and preliminary analyses so that they are preserved for scientific measurements for decades to come. In-situ measurements by Perseverance have identified minerals that further warrant special treatment of the returned samples. Hydrated sulfate carbonate, swelling clay minerals, and oxychlorine salts are extremely sensitive to changes in temperature and relative humidity. The structures of hydrated sulfates and oxychlorine minerals, in particular, readily change when exposed to different conditions, meaning the mineral assemblage of the as-returned samples may be lost if the samples aren’t handled properly. Characterizing the as-returned mineral assemblage, particularly of the salts, is essential for reconstructing past aqueous conditions and habitability. To characterize the as-returned mineral assemblage, the samples must be analyzed rapidly before phase changes occur and/or under controlled conditions (e.g., within a glove box). Significant recent advances in X-ray instrumentation for robotic exploration of the solar system have resulted in high-resolution miniaturized instruments that would provide mineralogical, geochemical, and petrological information on the returned martian samples without degradation of the mineral assemblage. Here, we describe a combined X-ray diffractometer/X-ray fluorescence spectrometer (XRD/XRF), an X-ray computed tomographic (XCT) instrument, and a scanned beam XRF mapping instrument that could be used in a glove box so that the martian samples remain under controlled conditions.

E. B. Rampe↗

Stardust Interstellar Preliminary Examination V: XRF Analyses of Interstellar Dust Candidates at ESRF ID13

Here, we report analyses by synchrotron X-ray fluorescence microscopy of the elemental composition of eight candidate impact features extracted from the Stardust Interstellar Dust Collector (SIDC). Six of the features were unambiguous tracks, and two were crater-like features. Five of the tracks are so-called midnight tracks that is, they had trajectories consistent with an origin either in the interstellar dust stream or as secondaries from impacts on the Sample Return Capsule (SRC). In a companion paper reporting synchrotron X-ray diffraction analyses of ISPE candidates, we show that two of these particles contain natural crystalline materials: the terminal particle of track 30contains olivine and spinel, and the terminal particle of track 34 contains olivine. Here, we show that the terminal particle of track 30, Orion, shows elemental abundances, normalized to Fe, that are close to CI values, and a complex, fine-grained structure. The terminal particle of track 34, Hylabrook, shows abundances that deviate strongly from CI, but shows little fine structure and is nearly homogenous. The terminal particles of other midnight tracks, 29 and 37, had heavy element abundances below detection threshold. A third, track28, showed a composition inconsistent with an extraterrestrial origin, but also inconsistent with known spacecraft materials. A sixth track, with a trajectory consistent with secondary ejecta from an impact on one of the spacecraft solar panels, contains abundant Ce and Zn. This is consistent with the known composition of the glass covering the solar panel. Neither crater-like feature is likely to be associated with extraterrestrial materials. We also analyzed blank aerogel samples to characterize background and variability between aerogel tiles. We found significant differences in contamination levels and compositions, emphasizing the need for local background subtraction for accurate quantification.

Stardust↗

MapX: An In Situ, Full-Frame X-Ray Spectroscopic Imager for the Biogenic Elements

Microbial life exploits microscale disequilibria at boundaries where valence, chemical potential, pH, Eh, etc. vary on a length scale commensurate with the organisms themselves - tens to hundreds of micrometers. These disequilibria can exist within cracks or veins in rocks and ice, at inter- or intra-crystalline boundaries, at sediment/water or sediment/atmosphere interfaces, or even within fluid inclusions trapped inside minerals. The detection of accumulations of the biogenic elements C,N,O,P,S at appropriate concentrations on or in a mineral/ice substrate would constitute permissive evidence of extant life, but context is also required. Does the putative biosignature exist in a habitable environment? Under what conditions of P, T, and chemical potential was the host mineralogy formed? MapX is an arm-deployed contact instrument that directly images the biogenic elements C, N, O, P, S, as well as the cations of the rock-forming minerals (Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe) and important anions such as Cl, Fl. The instrument provides element images having ≤100 micron lateral spatial resolution over a 2.5 cm X 2.5 cm area, as well as quantitative XRF spectra from ground-selected or instrument-selected Regions of Interest (ROI) on the sample. Quantitative XRF spectra from ROI can be translated into mineralogies using ground- or instrument-based algorithms. Either an X-ray tube source (X-ray fluorescence) or a radioisotope source such as 244-Cm (alpha-particle and gamma-ray fluorescence) can be used, and characteristic X-rays emitted from the sample are imaged onto an X-ray sensitive CCD through an X-ray MicroPore Optic (MPO). As a fluorescent source, 244-Cm is highly desirable in a MapX instrument intended for life detection since high-energy alpha-particles are unrivaled in fluorescence yield for the low-Z elements. The MapX design as well as baseline performance requirements for a MapX instrument intended for life detection/identification of habitable environments will be presented.

micro-XRF spectrometer↗

Methods for identification and verification using vacuum XRF system

Apparatus and methods in which one or more elemental taggants that are intrinsically located in an object are detected by x-ray fluorescence analysis under vacuum conditions to identify or verify the object's elemental content for elements with lower atomic numbers. By using x-ray fluorescence analysis, the apparatus and methods of the invention are simple and easy to use, as well as provide detection by a non line-of-sight method to establish the origin of objects, as well as their point of manufacture, authenticity, verification, security, and the presence of impurities. The invention is extremely advantageous because it provides the capability to measure lower atomic number elements in the field with a portable instrument.

Schramm, Fred↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

INL CRMO XRF Special Report No. 3: INL CRMO XRF Calibration Methods for the Analysis of Ceramics and Brick

This report details the analytical methods used by the Idaho National Laboratory Cultural Resource Management Office to characterize ceramic and brick artifacts using X-ray fluorescence spectrometry. More specifically, this report provides details on instrumentation, analysis times, and matrix-specific calibration protocols for ceramic materials. Calibration curves were developed to adjust raw instrumental output for 13 elements using a suite of reference standards made from historic brick borrowed from the Yale Peabody Museum. Calibration curves were validated by plotting predicted values against published reference values for the calibration set as well as a certified soil reference standard (SRM 2711a).

36 MATERIALS SCIENCE↗

Nanoscale elemental and morphological imaging of nitrogen-fixing cyanobacteria

Nitrogen-fixing cyanobacteria bind atmospheric nitrogen and carbon dioxide using sunlight. This experimental study focused on a laboratory-based model system, Anabaena sp., in nitrogen-depleted culture. When combined nitrogen is scarce, the filamentous prokaryotes reconcile photosynthesis and nitrogen fixation by cellular differentiation into heterocysts. To better understand the influence of micronutrients on cellular function, 2D and 3D synchrotron X-ray fluorescence mappings were acquired from whole biological cells in their frozen-hydrated state at the Bionanoprobe, Advanced Photon Source. To study elemental homeostasis within these chain-like organisms, biologically relevant elements were mapped using X-ray fluorescence spectroscopy and energy-dispersive X-ray microanalysis. Higher levels of cytosolic K + , Ca 2+ , and Fe 2+ were measured in the heterocyst than in adjacent vegetative cells, supporting the notion of elevated micronutrient demand. P-rich clusters, identified as polyphosphate bodies involved in nutrient storage, metal detoxification, and osmotic regulation, were consistently co-localized with K + and occasionally sequestered Mg 2+ , Ca 2+ , Fe 2+ , and Mn 2+ ions. Machine-learning-based k-mean clustering revealed that P/K clusters were associated with either Fe or Ca, with Fe and Ca clusters also occurring individually. In accordance with XRF nanotomography, distinct P/K-containing clusters close to the cellular envelope were surrounded by larger Ca-rich clusters. The transition metal Fe, which is a part of nitrogenase enzyme, was detected as irregularly shaped clusters. The elemental composition and cellular morphology of diazotrophic Anabaena sp. was visualized by multimodal imaging using atomic force microscopy, scanning electron microscopy, and fluorescence microscopy. This paper discusses the first experimental results obtained with a combined in-line optical and X-ray fluorescence microscope at the Bionanoprobe.

Anabaena sp↗

MapX An In Situ, Full-frame X-Ray Spectroscopic Imager for Planetary Science and Astrobiology

Microbial life exploits micron-scale disequilibria at boundaries where valence, chemical potential, pH, Eh, etc. vary on a length scale commensurate with the organisms - 10's to 100's of microns. The detection of accumulations of the biogenic elements C,N,O,P,S at appropriate concentrations on or in a mineral/ice substrate would constitute permissive evidence of extant life, but context is also required. Does the putative biosignature exist under habitable conditions? Under what conditions of P, T, and chemical potential was the host mineralogy formed? MapX is an in situ robotic spacecraft instrument that images the biogenic elements C, N, O, P, S, as well as the cations of the rock-forming minerals (Na, Mg, Al, Si, K, Ca, Ti, Cr, Mn, Fe) and important anions such as Cl, Fl. MapX provides element maps with less than or equal to100 microns resolution over a 2.5 cm X 2.5 cm area, as well as quantitative XRF spectra from ground- or instrument-selected Regions of Interest (ROI). XRF spectra are converted to mineralogies using ground- or instrument-based algorithms. Either X-ray tube or radioisotope sources such as 244Cm (Alpha-particle and gamma- ray fluorescence) can be used. Fluoresced sample Xrays are imaged onto an X-ray sensitive CCD through an X-ray MicroPore Optic (MPO). The MapX design as well as baseline performance requirements for a MapX instrument intended for life detection / identification of habitable environments will be presented.

Astrobiology↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

Elemental composition of the Martian surface

The Viking landers carried X-ray fluorescence spectrometers (XRFS) to the surface of Mars for direct in-situ measurements of the elemental composition of samples that could be acquired by the surface sampler scoops. A total of 21 samples at two landing sites were acquired and analyzed. In this review, the constraints imposed on the design and operation of the XRFS; the accuracy and precision limitations of XRF; and the interpretation of the results are discussed. The latter includes relevance of the investigation to Martian geological processes, SNC meteorites, the formation and history of Mars, and future mission objectives/capabilities.

Clark, Benton C.↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

CHEMIN: A Mineralogical Dust Analyzer for the Odyssey Mission to Comet Kopff

The Odyssey spacecraft will be launched in June 2006 and will rendezvous with periodic Comet Kopff in September 2009. Odyssey will initially perform slow flybys of the active Kopff nucleus at distances between 500 and 100 km, and will then be placed in orbit around the nucleus at altitudes between 200 and 50 km. Odyssey's scientific payload of seven instruments includes CHEMIN, a mineralogical dust analyzer, which will make the first direct measurements of the crystal structure and elemental composition of cometary dust. CHEMIN will simultaneously perform X-ray Diffraction and X-ray Fluorescence (XRD/XRF) of individual 1-100 micron dust particles collected passively as the spacecraft is immersed in the comet's coma. The instrument has the geometry of a microfocus X-ray camera, with a postage stamp-sized energy-discriminating CCD in place of the film, and a miniature Cu target X-ray tube as the X-ray source. The CHEMIN flight instrument will weigh less than 2 kg., will have a total volume of about 1 liter, and will operate on 3 watts of power. Individual analyses will require 1-2 hours. XRD maxima from 5 to 65 degrees two-theta will be collected, encompassing definitive peaks for all known minerals. XRF data will be simultaneously collected for elements C through U. The instrument has sufficient resolution to allow Rietveld refinement of the diffraction data. Rock types as complex as basalt have been quantitatively analyzed using a CHEMIN laboratory prototype. Selected examples of diffraction experiments performed on more than 30 minerals and rock types by the CHEMIN laboratory prototype will be discussed.

Blake, David↗

Probing the Mechanism of Selective Phosphate Adsorption from Wastewater Using Aqueous and Synchrotron X-ray Characterization

Ion exchange shows promise for recovering phosphate from wastewater as value-added products, but requires high phosphate selectivity to compete with conventional treatment. Hybrid anion exchange (HAIX) resins, which contain non-selective basic functional groups and selective iron oxide nanoparticles (FeOnp), can effectively remove phosphate from wastewater. However, knowledge gaps remain regarding the mechanisms of phosphate selectivity and influence of competing ions, hindering needed efforts to model adsorption dynamics and design scalable adsorption processes for varying wastewaters. To address these gaps, we integrated aqueous-phase adsorption analysis with solid-phase, synchrotron-based X-ray characterization; this integration facilitated elucidation of the distribution and speciation of iron, phosphate, and competing anions on HAIX resins. We compared a quaternary ammonium-functionalized HAIX resin (SBA) to a tertiary amine version (WBA) to determine the role of functional groups. X-ray radiography revealed differences in FeOnp speciation (goethite vs. ferrihydrite) and distribution (peripheral vs. homogeneous) between the resins, resulting in varied phosphate affinity and intraparticle diffusion resistance. Using micro-X-ray fluorescence (μ-XRF) and micro-X-ray absorption near-edge structure (μ-XANES) spectroscopy, we identified differences in where and how phosphate binds across resin types and wastewaters. Across wastewater compositions, FeOnp sites in WBA contribute more to phosphate adsorption than in SBA, possibly due to variations in Fe distribution and speciation. Phosphate adsorption densities calculated from quantitative μ-XRF maps matched those from aqueous analysis, demonstrating the effectiveness of this integrated approach. Altogether, results demonstrate the use of synchrotron-based X-ray characterization for investigating adsorption mechanisms and advance HAIX as a phosphate recovery technology from complex wastewaters.

Nutrient recovery↗

Initial analysis of “stone” size Ryugu samples: current status

As a part of the initial analysis of the Ryugu samples, we perform a variety of analyses of millimeter-sized "stones". Our goals are to elucidate the entire formation process of C-type asteroid Ryugu from the viewpoint of petrology and mineralogy ande obtain necessary information by sample analysis, and then simulate the formation of Ryugu based on the evidencef obtained rom sample analysis. Eighteen stones (8 from Room A and 10 from Room C) were received from the ISAS curation facility on June 1, 2021, and brought into a fully nitrogen-displaced glove box at Tohoku University. At the same time, we also received the powder samples from Room A and Room C. To completely block the atmosphere from leaking into the container, all samples were put in the sample transport containers prepared by ISAS, transferred from the main chamber to the glovebox at ISAS, and then all containers were completely sealed in plastic bags with moisture and oxygen absorbers. No moisture or oxygen was detected when the bags were opened in the glove box at Tohoku University, so it was confirmed that there was no exposure to the atmosphere during transport. To date, a number of analyses have been carried out successfully and almost on schedule. The analysis started with the measurement of reflectance spectra, which are sensitive to atmospheric oxidation, hydroxylation, and adsorbed water. The visible, near-infrared, and mid-infrared reflectance spectra were measured while the samples were kept airtight. The spectra of powder samples and stone samples (as aggregates and as single stone) were successfully obtained. A major feature of the stone team's analysis is the use of synchrotron radiation facilities around the world. Since this analysis is non-destructive, stone samples whose reflectance spectra were measured were sent to KEK, SPring-8, ESRF (France), SOLEIL (France), DESY (Germany), and APS (USA). Using these synchrotron radiation facilities, high spatial resolution and sensitivity XRD, STXM, XANES, CT [1], IR-CT, FT-IR [2, 3], XRF, and Mössbauer analyses were performed. Most of the analyses were carried out under air-tight conditions on the stone samples and the particulates separated from the stone samples. These analyses allowed us to determine the three-dimensional distribution of minerals and elements, redox state, density and porosity of the stone samples. Furthermore, as a characteristic analysis of the stone team, light elemental analysis using negative Muon was performed at the MLF facility of J-PARC with an exceptionally long allocation of machine time. This is the only non-destructive method to measure the concentration of light elements in the whole (not the surface) of stone samples. Because the characteristic X-rays produced by muon irradiation are much higher in energy than the fluorescent X-rays produced by X-ray irradiation, there is little effect of self-absorption by the sample, and therefore, the concentration of light elements such as carbon, oxygen, and Na in the entire "stone" sample can be determined. Some stone samples are currently being measured for heat and strength physical properties in order to understand the physical properties of asteroid Ryugu. The data obtained from these measurements are useful for interpreting the remote-sensing data data taken from the surface layer of the asteroid Ryugu [4-7]. It is also important for understanding the behavior of the Ryugu material during impact events. The surfaces of many stone samples were observed by electron microscopy and other techniques, especially on natural “flat” surfaces formed on 5 stomes. As a result, characteristric mineral aggregates formed by the reactions with water and characteiristic impact features were observed on some of the samples. Based on the observations of surfaces and the synchrotron measurements of the whole stones, important objects such as characteristic structures and specific crystal aggregates for understanding the formation history of the asteroid were identified, and these parts were separated from the stone samples using an Xe beam (pFIB) and analyzed by various methods including transmission electron microscopy and synchrotron radiation analysis. Many stone samples, from which important objects have been separated, are embedded in epoxy resin and cut to produce many polished sections. Electron microscopy and spectroscopic measurements of the polished surfaces are being carried out to reveal the detailed mineralogical properties and elemental distribution inside the stone samples. In the fall, machine time for synchrotron radiation will begin, and we plan to analyze single crystals and characteristic objects separated from the stone samples.

Tomoki Nakamura↗

Combined Backscatter Moessbauer Spectrometer and X Ray Fluorescence analyzer (BaMS/XRF) for planetary surface materials

A backscatter Moessbauer spectrometer (BaMS) with included x ray fluorescence (XRF) capability for the Mars Environment Survey (MESUR) Mission, which has been proposed by NASA for 1998, is being developed. The instrument will also be suitable for other planetary missions such as those to the Moon, asteroids, and other solid solar-system objects. The BaMS would be unique for MESUR in providing information about iron mineralogy in rocks, clays, and other surface materials, including relative proportions of iron-bearing minerals. It requires no sample preparation and can identify all the normal oxidation states of iron (3+, 2+, 0). Thus, BaMS is diagnostic for weathering and other soil-forming processes. Backscatter design allows the addition of XRF elemental analysis with little or no modification. The BaMS/XRF instrument complements the thermal analyzer with evolved gas analyzer (TA-EGA) and the alpha-proton x-ray spectrometer (APXS) proposed (along with BaMS) for geochemical analysis on MESUR.

Agresti, D. G.↗

Root size and soil physicochemical properties drive microscale spatial patterns of Fe and As retention in the rice rhizosphere

Background and Aims: Radial oxygen loss from rice roots in flooded soils oxidizes and precipitates dissolved Fe(II), Mn(II), and As(III) into mixed Fe(III), Mn(III/IV), and As(V) as root plaque and in the rhizosphere soil. It is unknown how different soils and root sizes impact the spatial extent of Fe and As retention outside the root. Methods: We imaged cross-sections of 90 roots from 6 different soils using synchrotron μXRF imaging followed by k-means clustering and elliptical averaging to distinguish bulk soil, rhizosphere, plaque, and roots based on As and Fe patterns. Results: We found preferential As retention in the plaque and rhizospheres of most roots except small (< 0.45 mm) roots in silty soils with low P or high As. In contrast, clayey soils had similar As-Fe correlations across plaque, rhizosphere, and bulk soil. Large (> 0.45 mm) roots often had no oxidized rhizosphere region. We obtained an extensive dataset of 256 As and 155 Mn synchrotron μXANES measurements, which revealed that rhizosphere and plaque As was mainly inorganic As(V) and As(III), and Mn oxidation state varied between soils but not between belowground locations. Conclusion: Small roots in coarse-textured soils were less likely to have As retention in the plaque or rhizosphere compared to large roots and fine-textured soils. Furthermore, the unique and extensive data in this study provides new insight into soil and root size impacts on As retention in the rhizosphere. It is essential to investigate a representative number of samples to draw conclusions from XRF imaging.

36 MATERIALS SCIENCE↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Multimodal, microspectroscopic speciation of legacy phosphorus in two US mid-Atlantic agricultural soils

To understand phosphorus (P) mobility in agricultural soils and its potential environmental risk, it is essential to directly measure solid phase P speciation. Often, bulk P K-edge X-ray absorption near edge structure (XANES) spectroscopy followed by linear combination fitting (LCF) is utilized to determine the solid P phases in soil. However, this method may limit results to only a few major phases. Additionally, XANES spectra for different P species may have very similar features, leading to an over- or underestimate of their contribution to LCF. Here, an improved P speciation by pairing multimodal microbeam-X-ray fluorescence (µ-XRF) mapping coupled with µ-XANES (microbeam-X-ray absorption near edge structure) analysis to directly speciate major and minor P phases on the micron scale is provided. We combined maps of both tender (P, sulfur, aluminum, and silicon) and hard energy (calcium, iron [Fe], and manganese) elements to evaluate the elemental co-locations with P. To better account for uncertainty assigning XANES peaks to individual compounds, a more quantitative fingerprinting by “spectral feature analysis” was completed. With this analysis, an R-factor is reported for the fit. These results were compared to traditional LCF. Pre-edge fitting results revealed the presence of a two-component pre-edge feature for phosphate adsorbed to ferrihydrite. Additionally, phytate co-precipitated with ferrihydrite (Phytate-Fe-Cop) had a pre-edge feature, indicating direct association with Fe. Lastly, a unique P species associated with manganese oxide was identified in the soil via multimodal mapping and µ-XANES. These results allow for better prediction of P dissolution and mobility.

36 MATERIALS SCIENCE↗