134 records · Page 8

Identification of mechanisms driving heterogeneous void growth in ductile aluminum

Void growth plays a central role in ductile fracture, yet the specific mechanisms that control this remain obscure. Classical models, such as those proposed by Rice and Tracey in 1969, are able to capture average rates of void growth, but cannot capture the heterogeneity of individual void growth. Building on recent work, the present study employs laboratory-based diffraction contrast tomography and in-situ x-ray computed tomography to investigate the effect of grain structure and other microstructural factors on void growth in an Al-2219 alloy. Crystal plasticity finite element (CP-FE) modeling is used alongside experimental data to evaluate the contributions of local mechanical states, grain orientation, grain size, and neighboring microstructural features. No strong linear relationships are found with any of the considered descriptors and void growth rate. Potential complex nonlinear relationships are explored with the use of a random forest regression model, which identifies initial void volume, void aspect ratio, local normal stress state, local shear stress state, and local equivalent plastic strain (EQPS) as features that most improve void growth rate predictions. The combination of these analyses suggests that these features should be prioritized to improve models of void growth.

Diffraction contrast tomography (DCT)↗

Geochemical Changes in Response to CO 2 Injection in a CO 2 -EOR Complex in Northern Michigan (Volume II.1)

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. The report describes the geochemical monitoring program under MRCSP to use stable and radiogenic isotope geochemistry in concert with analysis of general geochemical parameters of fluids and gases and analysis of core samples to determine geochemical processes occurring in the reef structure because of CO 2 injection. Specifically, brine and gas samples were collected and analyzed to determine changes occurring between reefs prior to and following CO 2 injection. The analytical results for general geochemical parameters were modeled with chemical equilibrium models to determine if the injection of CO 2 resulted in the mineral dissolution or precipitation. Finally, core samples were collected and analyzed to determine if there was evidence of dissolution features or mineral precipitation.

01 COAL, LIGNITE, AND PEAT↗

Photovoltaic Cable Connectors: A Comparative Assessment of the Present State of the Industry [Slides]

The consequences of failure for balance of systems (BoS) components (such as PV cable connectors) include offline module string(s); low system voltage; arc, ground, insulation, and over-temperature faults; triggered fuse(s); system shutdown; and fire. The degradation modes for connectors are studied here through an industry survey and its subsequent examination, which are compared to field-degraded specimens. 117 specimens were obtained from a variety of locations and climates or accelerated tests. A failure analysis for connectors from PV installations was developed (and applied to 54 specimens) including nondestructive examinations (photography, a custom resistance-current scan, and X-ray computed tomography) and destructive examinations (featuring milling of the external plastic, extraction of the internal convolute spring, and potting and polishing in cross-section). Surface and through-thickness composition of the metal pins and springs was quantified using scanning electron microscopy with energy-dispersive X-ray spectroscopy. Fourier-transform infrared spectroscopy was used to verify the base polymer materials and compare the chemical structure of the connector body, bushing, end nut, and o-ring. Thermogravimetric analysis and differential scanning calorimetry were used to further verify the degradation of the same polymeric components. Updated from 2023 NIST/UL Workshop on Photovoltaic Materials Durability (website: https://events.ul.com/WPMogn?rt=aAuoWsl4E0KaORLCMeOgfA) and 2024 PVRW workshop (https://pvrw.nrel.gov/past-proceedings).

14 SOLAR ENERGY↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

One thousand soils for molecular understanding of belowground carbon cycling

While significant progress has been made in understanding global carbon (C) cycling, the mechanisms regulating belowground C fluxes and storage are still uncertain. New molecular technologies have the power to elucidate these processes, yet we have no widespread standardized implementation of molecular techniques. To address this gap, we introduce the Molecular Observation Network (MONet), a decadal vision from the Environmental Molecular Sciences Laboratory (EMSL), to develop a national network for understanding the molecular composition, physical structure, and hydraulic and biological properties of soil and water. These data are essential for advancing the next generation of multiscale Earth systems models. In this paper, we discuss the 1000 Soils Pilot for MONet, including a description of standardized sampling materials and protocols and a use case to highlight the utility of molecular-level and microstructural measurements for assessing the impacts of wildfire on soil. While the 1000 Soils Pilot generated a plethora of data, we focus on assessments of soil organic matter (SOM) chemistry via Fourier-transform ion cyclotron resonance-mass spectrometry and microstructural properties via X-ray computed tomography to highlight the effects of recent fire history in forested ecosystems on belowground C cycling. We observed decreases in soil respiration, microbial biomass, and potential enzyme activity in soils with high frequency burns. Additionally, the nominal oxidation state of carbon in SOM increased with burn frequency in surface soils. This results in a quantifiable shift in the molecular signature of SOM and shows that wildfire may result in oxidation of SOM and structural changes to soil pore networks that persist into deeper soils.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.