Search NASA⌕ Search

SEARCH · Search NASA

Results for “XENON LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High pressure gas scintillation drift chambers with wave-shifter fiber readout. II

Results from a prototype high-pressure xenon gas scintillation drift chamber using a novel wave-shifter fiber readout scheme are presented. The primary scintillation light yield was measured to be one photon per 76 + or - 12 eV deposited energy. Initial results on the chamber are presented for two-interaction separation (less than 4 mm in the drift direction and about 7 mm orthogonal to the drift); for position resolution (less than 400 microns rms in the plane orthogonal to the drift direction); and for energy resolution (less than 6 percent FWHM at 122 keV).

Parsons, A.↗

A High Resolution Liquid Xenon Imaging Telescope for 0.3-10 MeV Gamma Ray Astrophysics: Construction and Initial Balloon Flights

The results achieved with a 3.5 liter liquid xenon time projection chamber (LXe-TPC) prototype during the first year include: the efficiency of detecting the primary scintillation light for event triggering has been measured to be higher than 85%; the charge response has been measured to be stable to within 0.1% for a period of time of about 30 hours; the electron lifetime has been measured to be in excess of 1.3 ms; the energy resolution has been measured to be consistent with previous results obtained with small volume chambers; X-Y gamma ray imaging has been demonstrated with a nondestructive orthogonal wires readout; Monte Carlo simulation results on detection efficiency, expected background count rate at balloon altitude, background reduction algorithms, telescope response to point-like and diffuse sources, and polarization sensitivity calculations; and work on a 10 liter LXe-TPC prototype and gas purification/recovery system.

Aprile, Elena↗

A data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time-dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple mode

Accelerator Physics (physics.acc-ph)↗

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss↗

A process of stellar nucleosynthesis which mimicks mass fractionation in P-xenon

The combination of the O-shell theory of Heymann and Dziczkaniec and the supernova theory of Woosley and Howard clearly identifies the astrophysical sites for the formation of the anomalous light Xe component in carbonaceous chondrites. These sites are the O- and Ne-shells, and possibly C-shell of a massive star. Most of the Xe-124 and Xe-126 are formed in the O-shell during hydrostatic core silicon-burning, when a seed of heavy nuclei is exposed to an effective temperature near T9 = 2.0. Xe-128 is formed via Ba-128 in the O-shell, but the amounts appear too small to satisfy the deduced Xe-128/Xe-124 and Xe-128/Xe-126 yield ratios from the chondrites. However, substantial amounts of Xe-128 can be formed in the adjacent Ne- and C-shells during the explosion. The formation of Ba-128 in the O-shell would increase if the (gamma, alpha) photodisintegration rate in Ba-128 is actually smaller than calculated by Woosley and Howard. Lewis et al. have proposed that the anomalous light Xe component is mass-fractionated normal Xe. It is in this sense that the process of stellar nucleosynthesis of the present paper mimicks mass-fractionation.

Heymann, D.↗

Low-Energy Sputtering Studies of Boron Nitride with Xenon Ions

Sputtering of boron nitride with xenon ions was investigated using secondary ion (SIMS) and secondary neutral (SNMS) mass spectrometry. The ions generated from the ion gun were incident on the target at an angle of 50' with respect to the surface'normal. The energy of ions ranged from 100 eV to 3 keV. A flood electron gun was used to neutralize the positive charge build-up on the target surface. The intensities of sputtered neutral and charged particles, including single atoms, molecules, and clusters, were measured as a function of ion energy. Positive SIMS spectra were dominated by the two boron isotopes whereas BN- and B- were the two major constituents of the negative SIMS spectra. Nitrogen could be detected only in the SNMS spectra. The intensity-energy curves of the sputtered particles were similar in shape. The knees in P-SIMS and SNMS intensity-energy curves appear at around I keV which is significantly higher that 100 to 200 eV energy range at which knees appear in the sputtering of medium and heavy elements by ions of argon and xenon. This difference in the position of the sputter yield knee between boron nitride and heavier targets is due to the reduced ion energy differences. The isotopic composition of secondary ions of boron were measured by bombarding boron nitride with xenon ions at energies ranging from 100 eV to 1.5 keV using a quadrupole mass spectrometer. An ion gun was used to generate the ion beam. A flood electron gun was used to neutralize the positive charge buildup on the target surface. The secondary ion flux was found to be enriched in heavy isotopes at lower incident ion energies. The heavy isotope enrichment was observed to decrease with increasing primary ion energy. Beyond 350 eV, light isotopes were sputtered preferentially with the enrichment increasing to an asymptotic value of 1.27 at 1.5 keV. The trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.

Ray, P. K.↗

Heat dissipation in controlled environment enclosures through the application of water screens

The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPF's. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper is on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglass) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infrared wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12%) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented here demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study. The amounts and proportions of long-wave and short-wave radiation in a plant growth chamber are dependent on lamp type, lamp combination, presence of a thermal barrier, the type of thermal barrier between the lamps and the plant growing area and the overall construction and design of the chamber. It is important, therefore, in reporting results of controlled environment studies, to adequately describe both the details of the lighting system used and the characteristics of the radiation produced by that system, so results of different studies can be adequately evaluated and compared.

Warrington, I. J.↗

Isotopic Enrichment of Boron in the Sputtering of Boron Nitride with Xenon Ions

An experimental study is described to measure the isotopic enrichment of boron. Xenon ions from 100 eV to 1.5 keV were used to sputter a boron nitride target. An ion gun was used to generate the ion beam. The ion current density at the target surface was approximately 30 microA/sq cm. Xenon ions impinged on the target surface at 50 deg angle to the surface normal. Since boron nitride is an insulator, a flood electron gun was used in our experiments to neutralize the positive charge buildup on the target surface. The sputtered secondary ions of boron were detected by a quadrupole mass spectrometer. The spectrometer entrance aperture was located perpendicular to the ion beam direction and 10 mm away from the target surface. The secondary ion flux was observed to be enriched in the heavy isotopes at lower ion energies. The proportion of heavy isotopes in the sputtered secondary ion flux was found to decrease with increasing primary ion energy from 100 to 350 eV. Beyond 350 eV, light isotopes were sputtered preferentially. The light isotope enrichment factor was observed to reach an asymptotic value of 1.27 at 1.5 keV. This trend is similar to that of the isotopic enrichment observed earlier when copper was sputtered with xenon ions in the same energy range.

Ray, P. K.↗

Direct nuclear pumping of a helium-xenon laser

Experiments attempting to achieve laser excitation by direct interaction of nuclear reaction products (fission fragments) with the lasing media are reported. Laser output followed reactor power surge by 50 microsec, the neutron thermalization time. The light output exhibited a threshold for onset and termination of laser action. The observed light output was shown to be caused by stimulated emission, because the signal disappeared when the totally reflecting (flat) mirror at one end of the apparatus was covered. Fission fragments were shown to be responsible for the stimulated emission, because the laser output disappeared when the U-235 liner was covered by an aluminum foil.

Helmick, H. H.↗

Laboratory evaluation of Fecker and Loral optical IR PWI systems

A previous flight test of two electro-optical pilot warning indicators, using a flashing xenon strobe and silicon detectors as cooperative elements, pointed out several design deficiencies. The present laboratory evaluation program corrected these faults and calibrated the sensitivity of both systems in azimuth elevation and range. The laboratory tests were performed on an optical bench and consisted of three basic components: (1) a xenon strobe lamp whose output is monitored at the indicator detector to give pulse to pulse information on energy content at the receiver; (2) a strobe light attenuating optical system which is calibrated photometrically to provide simulated range; and (3) a positioning table on which the indicator system under study is mounted and which provides spatial location coordinates for all data points. The test results for both systems are tabulated.

Gorstein, M.↗

Energy resolution of the LZ detector for high-energy electronic recoils

The LUX-ZEPLIN (LZ) detector is a dual-phase liquid xenon time projection chamber (TPC) installed at the Sanford Underground Research Facility (Lead, South Dakota) at a depth of 1478 meters. Although the main objective of LZ is the direct detection of dark matter, its low background environment allows for the search of other rare processes, such as the neutrinoless double beta decay of xenon isotopes 134 Xe and 136 Xe with the respective Q-values of 826 keV and 2458 keV. The sensitivity of the detector to these decays is directly determined by the energy resolution, which, in turn, is degraded by non-uniformities in detector response. In this work, we present a novel method to correct, in the data, the non-uniformity of the light collected by an array of photosensors in a scintillation detector. This method is based on the knowledge of the light response functions of individual photosensors. With these techniques, we report, at a very early phase of the detector operations, a state-of-the-art energy resolution (σ/μ) of (0.67 ± 0.01)% at 2614 keV for the fiducial volume of 5.6 tonnes of liquid xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comments on 'Extinct radioactivities: Trapped residuals of presolar grains'

It has recently been suggested that extinct I-129 and Pu-244 were trapped in primitive-solar-nebula ('presolar') grains and decayed into radiogenic Xe-129 and fission Xe before the grains were incorporated into meteorite bodies. This idea is reconsidered in light of the thermal and metamorphic history of meteorites. The criteria that parent and daughter species should never separate and that minerals or grains containing the anomalous xenon should not be subjected to temperatures exceeding 500 C are applied to iron meteorites, achondrites, and chondrites to determine whether presolar grains could be the carriers of rare-gas anomalies to meteorites. The results strongly indicate that the xenon anomaly could not have originated in presolar grains. Other difficulties with the presolar-grain model are discussed, including insufficiently small grain sizes, large variations in Xe-129/I-127 ratios in various meteorites, and apparently unrealistic meteorite formation times and locations.

Trivedi, B. M. P.↗

Ultralow Energy Electron Attachment at Sub-Millielectron Volt Resolution

The technique of rare-gas photoionization has been extended by use of direct laser ionization to electron energies epsilon in the range 0-100 meV, with a resolution Delta(epsilon) of 0.4-0.5 meV (FWHM). Tunable UV light at (Lambda)276 nm is produced using a pulsed Nd:YAG laser and nonlinear mixing techniques. The beam is frequency tripled in a pulsed jet of xenon. The VUV radiation, tunable at (Lambda)92 nm, is then used to photoionize Xe at its 2P(sub 1/2) threshold (single-photon ionization). The photoelectrons produced interact with admixed target gas to generate negative ions through the s-wave capture process. Recent results in electron attachment to SF(sub 6) will be reported which show resonance structure at the opening of the ground-state vibrational channels. This structure corresponds to the process of vibrational excitation + attachment, which is superimposed on the underlying s-wave (direct) capture process. It should be a general phenomenon, present in a wide variety of zero-energy electron attaching molecules.

Chutjian, A.↗

Understanding spectral dependance of laser-induced damage precursors in dielectric materials (Abbreviated report_23-ERD-006)

High peak and average power laser systems are typically limited by the handling fluence of the optical components. In particular, the multilayer dielectric coatings are known to be much lower operational fluence than the more ideal bulk materials. In this project we proposed and succeeded in probing different established classes of damage prone precursors at different wavelengths to understand their fundamental laser damage response as a function of wavelength. This study helped to shed light on the fundamental physics of the non-linear precursors that govern laser damage phenomena for ns-regime pulsed laser damage. In this study, we utilized the onsite coating capabilities (VPL, IBS coating lab) to purposefully generate laser damage-prone precursors in hafnia-based coatings (both single and multi-layer coatings). Specifically, we engineered coatings with craze lines initiated by nodules, generated coatings with our xenon-based coating process to suppress nanobubble formation and generated hafnia coatings under controlled oxygen flow conditions to study hafnia sub-oxides and oxygen flow dependance. In these studies we found that craze lines are rife with precursors that are sensitive to ultra-violet light but not to infrared light; we found that the removal of nanobubbles helps with all wavelengths tested, but is most impactful for ultra-violet light; we also found that ultra-violet laser damage performance of hafnia is closely matched to oxygen flow rate, while the infrared performance may be slightly better at lower flow rates. During this LDRD we also successfully stood up a new laser damage testing capability, namely a wavelength agile damage test station to study the spectral response of known laser-induced damage precursors. This is a unique and important capability for Lawrence Livermore National Lab, allowing us to understand the spectral response of materials under high intensity irradiation and damage. This is a vital tool to understand non-linear optical response at wavelengths that we have previously been unable to test at.

36 MATERIALS SCIENCE↗

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

Optical Signature Analysis of Tumbling Rocket Bodies via Laboratory Measurements

The NASA Orbital Debris Program Office has acquired telescopic lightcurve data on massive intact objects, specifically spent rocket bodies, in order to ascertain tumble rates in support of the Active Debris Removal (ADR) task to help remediate the LEO environment. Rotation rates are needed to plan and develop proximity operations for potential future ADR operations. To better characterize and model optical data acquired from ground-based telescopes, the Optical Measurements Center (OMC) at NASA/JSC emulates illumination conditions in space using equipment and techniques that parallel telescopic observations and source-target-sensor orientations. The OMC employs a 75-watt Xenon arc lamp as a solar simulator, an SBIG CCD camera with standard Johnson/Bessel filters, and a robotic arm to simulate an object's position and rotation. The light source is mounted on a rotary arm, allowing access any phase angle between 0 -- 360 degrees. The OMC does not attempt to replicate the rotation rates, but focuses on how an object is rotating as seen from multiple phase angles. The two targets studied are scaled (1:48), SL-8 Cosmos 3M second stages. The first target is painted in the standard government "gray" scheme and the second target is primary white, as used for commercial missions. This paper summarizes results of the two scaled rocket bodies, each rotated about two primary axes: (a) a spin-stabilized rotation and (b) an end-over-end rotation. The two rotation states are being investigated as a basis for possible spin states of rocket bodies, beginning with simple spin states about the two primary axes. The data will be used to create a database of potential spin states for future works to convolve with more complex spin states. The optical signatures will be presented for specific phase angles for each rocket body and shown in conjunction with acquired optical data from multiple telescope sources.

Cowardin, H.↗

High power laser apparatus and system

A high-power, continuous-wave laser was designed for use in power transmission and energy-collecting systems, and for producing incoherent light for pumping a laser material. The laser has a high repetitive pulsing rate per unit time, resulting in a high-power density beam. The laser is composed of xenon flash tubes powered by fast-charging capacitors flashed in succession by a high-speed motor connected to an automobile-type distributor.

Evans, J. C., Jr.↗

Xenon and other noble gases in shergottites

The isotopic composition of the xenon component trapped in EETA 79001's lithologies B and C has been determined, and other noble gases were measured in some samples. The Xe component was found to have light isotope ratios indistinguishable from those of the terrestrial atmosphere. The trapped component has a Xe-129/Xe-132 ratio of about 2.4, and is enhanced in Xe-134 and Xe-136 relative to the terrestrial atmosphere or the average carbonaceous chondrite. Similarities between values for Ar-40/Ar-36, Xe-129/Xe-132, and N-15/N-14 and the corresponding Martian atmospheric values suggest Martian origin of the trapped gases.

Swindle, T. D.↗