Search NASA⌕ Search

SEARCH · Search NASA

Results for “Xe(OF)2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Effect of Ion Irradiation on Amorphous and Crystalline Ge–Se and Their Application as Phase Change Temperature Sensor

Research on phase change materials is predominantly focused on their application as memory devices or for temperature control which requires low phase change temperature. The Ge–Se binary chalcogenide glass system with its wide glass-forming region is a potential candidate for high-temperature and high-radiation phase change applications. In this study, the concept of employing Ge x Se 100– x glasses to monitor high temperature (450–528 °C) using the phase change effect, is reported. Materials selection, device structure, and performance of prototype sensors are analyzed. In addition, the effect of heavy ion irradiation by Xe ions with energies of 200, 600, and 1000 keV (fluence ≈10 14 cm –2 ) on the Ge x Se 100– x ( x = 30, 33, 40) thin films and phase change devices is studied. The irradiation effect on the amorphous and crystalline structure of the thin films is evaluated by Raman spectroscopy and X-ray diffraction (XRD). Although the changes in the structural units of amorphous films are negligible, in crystalline films orthorhombic-GeSe 2 crystals are found to be most affected by irradiation and a new phase, orthorhombic GeSe is found in the thin films after irradiation. The performance of a sensor with an active film of Ge 40 Se 60 is also shown as an example.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microsized Pore Structure Determination in EPDM Rubbers Using High-Pressure 129 Xe NMR Techniques

Microsized pore parameters, such as pore size and distance between pores in a series of model EPDM rubbers, were determined in situ under the pressure of 500 psi using 129 Xe nuclear magnetic resonance (NMR) techniques: spin–lattice (T 1 ) and spin–spin (T 2 ) relaxation measurements, pulsed-field gradient (PFG) NMR, and two-dimensional exchange spectroscopy (2D EXSY). The T 1 /T 2 (>>1) ratio for the xenon confined in the pores is larger than that for nonconfined free xenon. This suggests that almost the entire pore surface interacts with xenon atoms like a closed pore. While these pores still connect each other through very narrow diffusion/exchange channels, it is possible to observe the echo decay in PFG-NMR and cross-peaks in 2D EXSY. The results show that both diffusion (D pore ≈ 2.1 × 10 –10 m 2 /s) and exchange (exchange rate, τ exch = a few tens of milliseconds) of xenon between a pore within the material and outer surface are prolonged. The exchange distances (l), which correspond to the xenon gas penetration depth, were estimated to be 70–100 μm based on the measured diffusion coefficients and exchange rate (1/τ exch ). NMR diffraction analysis reveals that pore size (a) and pore distance (b) are on the order of magnitude of micrometers and tens of micrometers, while the diffusion coefficients of xenon gas in the diffusion channels (D eff ) are about 10 –8 m 2 /s. Overall, this study suggests that the pores with a few micrometers connected through very narrow flowing channels with the length of several tens of micrometers are developed 70 to 100 μm below the rubber surface. Furthermore, the overall steady-state diffusion of xenon is slower, approximately 2 orders of magnitudes, than the diffusion in the channel between the pores. Finally, the pore and exchange distances correlated with the composition of rubbers showed that the properties of EPDM rubber as a high-pressure gas barrier could be improved by reducing the size of cracks and the depth of gas penetration by the addition of both carbon black and silica fillers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

UNESE Phase 2: Injection and measurement of gaseous tracers at U-12p Tunnel

In June 2018 radioactive ( 37 Ar and 127 Xe) and stable (SF 6 ) tracers were injected into the chimney of the Disko Elm underground nuclear explosion, located in the U-12p tunnel complex. After the injection sampling was performed from locations within the tunnel, a borehole drilled from the surface, and from the surface of the mesa. Additionally, the 127 Xe activity within the chimney was continuously monitored for two months after the injection. While none of the injected radiotracers were detected in the monitoring borehole, elevated levels of 39 Ar (an activation product produced by underground nuclear explosions) were detected and quantified in each sample.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mars - Regolith adsorption and the relative concentrations of atmospheric rare gases

Laboratory measurements of Kr and Xe adsorption on samples of ground montmorillonite, limonite and basalt at -77 C have been performed. Results suggest that (1) most degassed martian Xe could be adsorbed on a regolith with a large effective surface area, and (2) if this is the case the elemental composition of martian nonradiogenic rare gas (counting that in the regolith) may be virtually identical to that of ordinary chondrites.

Fanale, F. P.↗

Large inert-gas thrusters

Using present technology as a starting point, performance predictions were made for large thrusters. The optimum beam diameter for maximum thruster efficiency was determined for a range of specific impulse. This optimum beam diameter varied greatly with specific impulse, from about 0.6 m at 3000 seconds (and below) to about 4 m at 10,000 seconds with argon, and from about 0.6 m at 2,000 seconds (and below) to about 12 m at 10,000 seconds with Xe. These beams sizes would require much larger thrusters than those presently available, but would offer substantial complexity and cost reductions for large electric propulsion systems.

Kaufman, H. R.↗

Near Earth Asteroid Human Mission Possibilities Using Nuclear Thermal Rocket (NTR) Propulsion

The NTR is a proven technology that generates high thrust and has a specific impulse (Isp (is) approximately 900 s) twice that of today's best chemical rockets. During the Rover and NERVA (Nuclear Engine for Rocket Vehicle Applications) programs, twenty rocket reactors were designed, built and ground tested. These tests demonstrated: (1) a wide range of thrust; (2) high temperature carbide-based nuclear fuel; (3) sustained engine operation; (4) accumulated lifetime; and (5) restart capability - all the requirements needed for a human mission to Mars. Ceramic metal fuel was also evaluated as a backup option. In NASA's recent Mars Design reference Architecture (DRA) 5.0 study, the NTR was selected as the preferred propulsion option because of its proven technology, higher performance, lower launch mass, versatile vehicle design, simple assembly, and growth potential. In contrast to other advanced propulsion options, NTP requires no large technology scale-ups. In fact, the smallest engine tested during the Rover program - the 25 klbf 'Pewee' engine is sufficient for a human Mars mission when used in a clustered engine configuration. The 'Copernicus crewed NTR Mars transfer vehicle design developed for DRA 5.0 has significant capability that can enable reusable '1-year' round trip human missions to candidate near Earth asteroids (NEAs) like 1991 JW in 2027, or 2000 SG344 and Apophis in 2028. A robotic precursor mission to 2000 SG344 in late 2023 could provide an attractive Flight Technology Demonstration of a small NTR engine that is scalable to the 25 klbf-class engine used for human missions 5 years later. In addition to the detailed scientific data gathered from on-site inspection, human NEA missions would also provide a valuable 'check out' function for key elements of the NTR transfer vehicle (its propulsion module, TransHab and life support systems, etc.) in a 'deep space' environment prior to undertaking the longer duration Mars orbital and landing missions that would follow. The initial mass in low Earth orbit required for a mission to Apophis is approximately 323 t consisting of the NTR propulsion module ((is) approximately 138 t), the integrated saddle truss and LH2 drop tank assembly ((is) approximately 123 t), and the 6-crew payload element ((is) approximately 62 t). The later includes a multi-mission Space Excursion Vehicle (MMSEV) used for close-up examination and sample gathering. The total burn time and required restarts on the three 25 klbf 'Pewee-class' engines operating at Isp (is) approximately 906 s, are approximately 76.2 minutes and 4, respectively, well below the 2 hours and 27 restarts demonstrated on the NERVA eXperimental Engine, the NRX-XE. The paper examines the benefits, requirements and characteristics of using NTP for the above NEA missions. The impacts on vehicle design of HLV payload volume and lift capability, crew size, and reusability are also quantified.

Borowski, Stanley↗

Possible octupole deformation of 208 Pb and the ultracentral v 2 to v 3 puzzle

Recent measurements have established the sensitivity of ultracentral heavy-ion collisions to the deformation parameters of nonspherical nuclei. In the case of 129 Xe collisions, a quadrupole deformation of the nuclear profile led to an enhancement of elliptic flow in the most central collisions. In 208 Pb collisions a discrepancy exists in similar centralities, where either elliptic flow is overpredicted or triangular flow is underpredicted by hydrodynamic models; this is known as the v 2 -to-v 3 puzzle in ultracentral collisions. Motivated by low-energy nuclear structure calculations, we consider the possibility that 208Pb nuclei could have a pear-shape deformation (octupole), which has the effect of increasing triangular flow in central PbPb collisions. Using the recent data from ALICE and ATLAS, we reexamine the v 2 -to-v 3 puzzle in ultracentral collisions, including new constraints from recent measurements of the triangular cumulant ratio v 3 {4}/v 3 {2} and comparing two different hydrodynamic models. We find that while an octupole deformation would slightly improve the ratio between v 2 and v 3 , it is at the expense of a significantly worse triangular flow cumulant ratio. In fact, the latter observable prefers no octupole deformation, with β 3 ≲ 0.0375 for 208 Pb, and is therefore consistent with the expectation for a doubly-magic nucleus even at top collider energies. Furthermore, the v 2 -to-v 3 puzzle remains a challenge for hydrodynamic models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural Damage and Recrystallization Response of Garnet Crystals to Intense Electronic Excitation

Here, the susceptibility to irradiation-induced damage, the fundamental mechanism of the relaxation kinetics, and the corresponding recrystallization effect related to the cation radius ratio are comprehensively investigated for Y 3 Al 5 O 12 and Gd 3 Ga 5 O 12 garnet crystals under 645 MeV Xe 35+ irradiation with different fluences of 5 × 10 11 –3 × 10 12 ions cm –2 . Regarding different lattice distortion and swelling levels, the observed microstructure transformations to disordered and amorphous phases, and corresponding hillock dimensions, consistently confirm that Gd 3 Ga 5 O 12 has a higher susceptibility to radiation damage than Y 3 Al 5 O 12 . Combined with iTS model calculations, although Y 3 Al 5 O 12 has higher atomic temperature and energy deposition than Gd 3 Ga 5 O 12 under the same ion velocity and electronic energy loss, the relatively high thermal conductivity and specific heat coefficient of Y 3 Al 5 O 12 crystals enhance the conduction and dissipation of deposition energy, and Gd 3 Ga 5 O 12 , with a higher cation-radius-ratio (r A /r B ), is more easily damaged to amorphous phase due to the less favorable kinetics of ordering and recovery of a melted track region to the crystalline phase. Additionally, the significant bandgap modification in spectral ranges of 5.88–6.75 eV for Y 3 Al 5 O 12 and 4.83–5.41 eV for Gd 3 Ga 5 O 12 , and the enhancement of defect-assisted-related luminescence are achieved, providing a basis to design novel optoelectronic devices in microelectronics fields.

36 MATERIALS SCIENCE↗

Focused ion beam milling of polycrystalline diamond

Focused ion beam (FIB) technology has a large potential for precise milling of ultrahard materials such as diamond. However, studies of the sputtering of diamond with ion species and energies relevant to the FIB technology are scarce. Here, we report a systematic study of the sputtering of polycrystalline diamond surfaces with ion beams in a wide range of ion energies (2 - 30 keV), incident beam angles (0 - 80°), and ion masses (N, O, Ar, and Xe). Results show that the sputter yield is relatively insensitive to ion energy but strongly depends on the ion species and incident beam angles. Bombardment with O ions results in sputter yields that are significantly larger than ballistic predictions due to chemical etching effects. Characteristic surface ripples develop for oblique beam incidence angle irradiation. The critical beam tilt angle for the onset of ripple formation and the wavelength of the ripples depend on ion species and energies. Ripples appear to suppress ion reflection at high beam tilt angles and, hence, a peak in the sputter yield angular dependence. In conclusion, these results have direct implications for the development of process parameter maps for high-precision ion-beam milling of diamond.

36 MATERIALS SCIENCE↗

Mixed metal vapor phase matching for third-harmonic generation

Phase matching for frequency tripling of 1.06 microns is demonstrated in a homogeneous mixture of sodium and magnesium vapor. The ratio of Mg to Na vapor pressures required for phase matching is 2:1. This ratio is about 1/75 of that required to phase match Na with Xe.

Bloom, D. M.↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest Results from the CUORE Experiment

Abstract The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for $$0\nu \beta \beta $$ 0 ν β β decay that has been able to reach the one-tonne mass scale. The detector, located at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, consists of an array of 988 $${\mathrm{TeO}}_{2}$$ TeO 2 crystals arranged in a compact cylindrical structure of 19 towers. CUORE began its first physics data run in 2017 at a base temperature of about 10 mK and in April 2021 released its $$3{\mathrm{rd}}$$ 3 rd result of the search for $$0\nu \beta \beta $$ 0 ν β β , corresponding to a tonne-year of $$\mathrm{TeO}_{2}$$ TeO 2 exposure. This is the largest amount of data ever acquired with a solid state detector and the most sensitive measurement of $$0\nu \beta \beta $$ 0 ν β β decay in $${}^{130}\mathrm{Te}$$ 130 Te ever conducted . We present the current status of CUORE search for $$0\nu \beta \beta $$ 0 ν β β with the updated statistics of one tonne-yr. We finally give an update of the CUORE background model and the measurement of the $${}^{130}\mathrm{Te}$$ 130 Te $$2\nu \beta \beta $$ 2 ν β β decay half-life and decay to excited states of $${}^{130}\mathrm{Xe}$$ 130 Xe , studies performed using an exposure of 300.7 kg yr.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for the Chiral Magnetic Effect with charge-dependent azimuthal correlations in Xe–Xe collisions at s NN = 5.44 TeV

Charge-dependent two- and three-particle correlations measured in Xe–Xe collisions at $\sqrt{s_{NN}}$ = TeV are presented. Results are obtained for charged particles in the pseudorapidity range |η| and transverse momentum interval 02. ≤ p T < GeV/c for different collision centralities. The three-particle correlator γ αβ ≡ $\langle$cos(φ α + φ β - 2Ψ a )$\rangle$, calculated for different combinations of charge sign α and β, is expected to be sensitive to the presence of the Chiral Magnetic Effect (CME). Its magnitude is similar to the one observed in Pb–Pb collisions in contrast to a smaller CME signal in Xe–Xe collisions than in Pb–Pb collisions predicted by Monte Carlo (MC) calculations including a magnetic field induced by the spectator protons. These observations point to a large non-CME contribution to the correlator. Furthermore, the charge dependence of γ αβ can be described by a blast wave model calculation that incorporates background effects and by the Anomalous Viscous Fluid Dynamics model with values of the CME signal consistent with zero. The Xe–Xe and Pb–Pb results are combined with the expected CME signal dependence on the system size from the MC calculations including a magnetic field to obtain the fraction of CME contribution in γ αβ , $f$ CME . The CME fraction is compatible with zero for the 30% most central events in both systems and then becomes positive. This yields an upper limit of 2% (3%) and 25% (32%) at 95% (99.7%) confidence level for the CME signal contribution to γ αβ in the 0–70% Xe–Xe and Pb–Pb collisions, respectively.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higher Throughput, Lower Cost Processing of Flexible Perovskite Solar Cells by Photonic Curing

The objectives of this SETO project are to explore whether photonic curing can be used to perform annealing in perovskite solar cell (PSC) fabrication, and if so, whether it can enable high-throughput PSC manufacturing. The successful outcome of the project will reduce manufacturing cost towards realizing the SETO goal of the Levelized cost of electricity (LCOE) $0.03/kWh by 2030. The project is a collaboration between Hsu’s group at the University of Texas at Dallas (UTD) and NovaCentrix, an Austin TX based company that pioneered the PulseForge® photonic curing tools and has expertise in applying this technology to printed electronics. Thin-film synthesis typically involves a thermal annealing step to convert from precursors to final material phases, to obtain the desired crystalline phase, or to improve materials structural or electrical properties. However, thermal annealing typically requires high temperatures that are incompatible with inexpensive plastic substrates and annealing times lasting tens-to-hundreds of minutes, making it incompatible with roll-to-roll (R2R) manufacturing at a desirable web speed. Photonic curing uses a flash Xe lamp to deliver short (20 µs to 100 ms) but high intensity (up to 50 kW/cm 2 ) pulses of broadband light (200 – 1500 nm) to the sample. It has been successfully applied to sinter printed metal nanoparticle inks into conductive patterns. This project aimed to extend the applications of photonic curing to convert halide perovskite films and transparent metal oxide transport layers. Despite the interruption by COVID-19, we have achieved significant accomplishments to establish photonic curing as a viable technology for the high-throughput manufacturing of PSCs. (1) We demonstrated that photonic curing can convert both metal oxide transport layer and halide perovskite absorber in the PSCs and successfully made flexible PSCs on Corning Willow glass® (WG)/ indium tin oxide (ITO) substrates without any thermal annealing steps. These photonically cured devices achieve performance comparable to conventional thermally annealed devices but were fabricated with a total processing time reduced by six orders of magnitude. We also show that photonic curing can achieve desirable web speed (up to 26 m/min) and large-area uniformity. (2) By establishing photonic curing processing phase spaces for the perovskite, we show that the longer pulses are more forgiving in small variation in the photonic curing conditions, making it more suitable for R2R manufacturing. (3) Our results clearly illustrated the importance of improving mechanical and optical properties of transparent electrodes on flexible substrates. (4) We also performed fundamental studies that elucidate the interactions between perovskite absorber and metal oxide transport layer that can undermine the PSC stability. Five refereed journal papers in top journals (ACS Energy Letters, npj Flexible Electronics, ACS Applied Energy Materials, Materials Advances, and Frontiers in Energy Research), one conference proceeding (PVSC-47), six conference presentations (PVSC and Materials Research Society meetings), and a Ph.D. dissertation (Trey B. Daunis) were produced under this project. Energy Materials Corporation (EMC) has forecast that with a 1.5 m wide web moving at a web speed of 30 m/min, R2R processing of PSC could provide up to 4 GW/year for a single R2R assembly line. Replacing thermal annealing with photonic curing, as demonstrated by the accomplishments of this project, is necessary to realize such an energy production goal.

14 SOLAR ENERGY↗

Carbon and nitrogen in Type 2 supernova diamonds

Abundant diamonds found in meteorites seem either to have condensed within supernova interiors during their expansions and coolings or to have been present around those explosions. Either alternative allows implantation of Xe-HL prior to interstellar mixing. A puzzling feature is the near normalcy of the carbon isotopes, considering that the only C-rich matter, the He-burning shell, is pure C-12 in that region. That last fact has caused many to associate supernova carbon with C-12 carbon, so that its SUNOCONS have been anticipated as very C-12-rich. We show that this expectation is misleading because the C-13-rich regions of Type 2's have been largely overlooked in this thinking. We here follow the idea that the diamonds nucleated in the C-12-rich He shell, the only C-rich site for nucleation, but then attached C-13-rich carbon during turbulent encounters with overlying C-13-rich matter. That is, the initial diamonds continued to grow during the same collisional encounters that cause the Xe-HL implantation. Instead of interacting with the small carbon mass having 13/12 = 0.2 in the upper He zone, however, we have calculated the remnants of the initial H-burning core, which left behind C-13-rich matter as it receded during core hydrogen burning. Howard et al. described why the velocity mixing would be essential to understanding the implantation of both the Xe-H and Xe-L components. Velocity mixing is now known to occur from the X-ray and gamma-ray light curves of supernova 1987A. Using the stellar evolution code developed at Goettingen, we calculated at Clemson the evolution of a grid of massive stars up to the beginning of core He burning. We paid attention to all H-burning reactions throughout the star, to the treatment of both convection and semiconvection, and to the recession of the outer boundary of the convective H-burning core as the star expands toward a larger redder state. This program was to generate a careful map of the CNO isotope distribution as He burning begins. Our result for the 30 solar mass star is shown.

Clayton, Donald D.↗

Impact of Glass Irradiation on Laser-induced Breakdown Spectroscopy Diagnostics in the Visible and NIR Range

Increased absorption of optical materials arising from the exposure to ionizing radiation must be accounted for to accurately analyze the laser-induced breakdown spectroscopy (LIBS) data retrieved from high-radiation environments. We evaluate this effect on a specifc example that mimics the diagnostics placed within a gas-cooled fast reactor coolant stream. Analysis is performed on the LIBS data measured with 1% Xe gas in an ambient He environment and the measured optical absorption from the gamma- and neutron-irradiated low-OH fused silica and sapphire glasses. No significant change in the number of shots required to reach a 3σ detection level was observed up to 10 Mrad gamma dose and exposure to a 1.7×10 17 n/cm 2 neutron fluence. In contrast, the spectral dependence of absorption results in either a systematic overestimation or underestimation of line intensity ratios, depending on the line of interest selected for analysis. Moreover, if lines from different spectral regions are used to create Boltzmann plots, this attenuation also leads to statistically significant changes in the calculated temperatures for calculations using Xe II lines only, lowering them from 8000±610 K to 6800±810 K for the case of exposure to the 1.7×10 17 n/cm 2 flux, and broadening the temperature range required for a 95% confidence interval. In the case of measuring the Xe spectrum, these effects may be mitigated using only the longer-wavelength spectral region, where radiation-attenuation is relatively small, or through analysis using the iterative Saha-Boltzmann method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron Cooling in NICA Acceleration Complex

The Nuclotron-based Ion Collider fAcility (NICA) is under assembling at JINR. NICA will provide colliding beams for study of hot strongly interacting baryonic matter and spin physics. The NICA injection complex includes a tandem of 2 superconducting synchrotrons: Booster (up to 600 MeV/u) and Nuclotron (up 3.9 GeV/u fully stripped heavy ions). Since the start of injection complex commissioning in 2020 its four Runs were carried out. To the present time the beams of He, Fe, C and Xe were accelerated. Booster electron cooling was first used for cooling of continuous Fe¹⁴⁺ beam at the energy of 3.2 MeV/u in Run II. In the last Run we demonstrated longitudinal cooling of Xe²⁸⁺ in the presence of RF voltage at the Booster injection energy. This regime is required for accumulation in Booster the intensity required for Collider operation. The cooling enabled a 2 times intensity increase of slow extracted beam from Nuclotron. Optimization of Booster electron cooling for beam accumulation will be carried out in the next Run. Another (high voltage) electron cooling system will be used in the NICA Collider rings for ion accumulation in a barrier bucket and consecutive bunch formation.

43 PARTICLE ACCELERATORS↗

Early Career Award: Single Molecule Fluorescence Imaging for a Background-Free Neutrinoless Double Beta Decay Search

This project aimed to develop a suite of novel technologies targeted at detecting individual barium ions produced in neutrinoless double beta decays of 136 Xe, as part of the NEXT program of gaseous xenon detectors. We realized novel molecules which could sense Ba 2+ ions in dry conditions; new microscopy techniques operable in dry noble gases, including the required operating conditions of xenon at 10 bar pressure; and new radiofrequency ion transport methods (developed both theoretically and experimentally) that can transport ions in dense xenon gas. Together, these developments represent a major advance toward a background-free neutrinoless double beta decay experiment based on single molecule fluorescence imaging of Ba 2+ daughter ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗