Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

CT imaging during microwave ablation: Analysis of spatial and temporal tissue contraction

Purpose: To analyze the spatial distribution and temporal development of liver tissue contraction during high-temperature ablation by using intraprocedural computed tomography (CT) imaging. Methods: A total of 46 aluminum fiducial markers were positioned in a 60 × 45 mm grid, in a single plane, around a microwave ablation antenna in each of six ex vivo bovine liver samples. Ablations were performed for 10 min at 100 W. CT data of the liver sample were acquired every 30 s during ablation. Fiducial motion between acquisitions was tracked in postprocessing and used to calculate measures of tissue contraction and contraction rates. The spatial distribution and temporal evolution of contraction were analyzed. Results: Fiducial displacement indicated that the zone measured postablation was 8.2 ± 1.8 mm (∼20%) smaller in the radial direction and 7.1 ± 1.0 mm (∼10%) shorter in the longitudinal direction than the preablation tissue dimension. Therefore, the total ablation volume was reduced from its preablation value by approximately 45%. Very little longitudinal contraction was noted in the distal portion of the ablation zone. Central tissues contracted more than 60%, which was near an estimated limit of ∼70% based on initial water content. More peripheral tissues contracted only 15% in any direction. Contraction rates peaked during the first 60 s of heating with a roughly exponential decay over time. Conclusions: Ablation zones measured posttreatment are significantly smaller than the pretreatment tissue dimensions. Tissue contraction is spatially dependent, with the greatest effect occurring in the central ablation zone. Contraction rate peaks early and decays over time.

60 APPLIED LIFE SCIENCES↗

Temporal changes in MRI appearance of the prostate after focal ablation

Purpose: The purpose of our study was to retrospectively evaluate and categorize temporal changes in MRI appearances of the prostate in patients who underwent focal therapy with MRI follow-up. Methods: The Institutional Review Board approved this retrospective study and waived the requirement for informed consent. Thirty-seven patients (median age 61; 48–70 years) with low-to-intermediate-risk, clinically organ-confined prostate cancer underwent focal ablation therapy from 2009 to 2014. Two radiologists reviewed post-treatment MRIs (n = 76) and categorized imaging features blinded to the time interval between the focal therapy and the follow-up MRI. Inter-reader agreement was assessed (kappa) and generalized linear regression was used to examine associations between an imaging feature being present/absent and days between ablation and MRI. Results: Inter-reader agreement on MRI features ranged from fair to substantial. Edema was found present at earlier times after ablation (median 16–25 days compared to MRIs without edema, median 252–514 days), as was rim enhancement of the ablation zone (18–22.5 days vs. 409–593 days), a hypointense rim around the ablation zone on T2-weighted images (53-57.5 days vs. 279–409 days) and the presence of an appreciable ablation cavity (48.5–60 days vs. 613–798 days, all p < 0.05). Enhancement of the ablation zone/scar (553–731 days vs. 61.5–162 days) and the formation of a T2-hypointense scar were found to be present on later MRI scans (514–553 days vs. 29–32 days, one reader). Conclusions: The MRI appearance of the prostate after focal ablation changes substantially over time. Identification of temporal patterns in the appearance of imaging features should help reduce image interpretation variability and errors when assessing post-therapeutic scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation dynamics in coiled wire-array Z-pinches

Experiments to study the ablation dynamics of coiled wire arrays were performed on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and on the COBRA generator at Cornell University's Laboratory of Plasma Studies (1 MA, 100 ns). The MAGPIE generator was used to drive coiled wires in an inverse array configuration to study the distribution of ablated plasma. Using interferometry to study the plasma distribution during the ablation phase, absolute quantitative measurements of electron line density demonstrated very high density contrasts between coiled ablation streams and inter-stream regions many millimetres from the wire. The measured density contrasts for a coiled array were many times greater than that observed for a conventional array with straight wires, indicating that a much greater axial modulation of the ablated plasma may be responsible for the unique implosion dynamics of coiled arrays. Experiments on the COBRA generator were used to study the complex redirection of plasma around a coiled wire that gives rise to the ablation structure exhibited by coiled arrays. Observations of this complex 3D plasma structure were used to validate the current model of coiled array ablation dynamics [Hall et al., Phys. Rev. Lett. 100, 065003 (2008)], demonstrating irrefutably that plasma flow from the wires behaves as predicted. Coiled wires were observed to ablate and implode in the same manner on both machines, indicating that current rise time should not be an issue for the scaling of coiled arrays to larger machines with fast current rise times.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulations of the ablative Rayleigh-Taylor instability in planar inertial-confinement-fusion targets using the FastRad3D code

The ablative Rayleigh-Taylor (RT) instability is a central issue in the performance of laser-accelerated inertial-confinement-fusion targets. Historically, the accurate numerical simulation of this instability has been a challenging task for many radiation hydrodynamics codes, particularly when it comes to capturing the ablatively stabilized region of the linear dispersion spectrum and modeling ab initio perturbations. Here, we present recent results from two-dimensional numerical simulations of the ablative RT instability in planar laser-ablated foils that were performed using the Eulerian code FastRad3D. Our study considers polystyrene, (cryogenic) deuterium-tritium, and beryllium target materials, quarter- and third-micron laser light, and low and high laser intensities. An initial single-mode surface perturbation is modeled in our simulations as a small modulation to the target mass density and the ablative RT growth-rate is calculated from the time history of areal-mass variations once the target reaches a steady-state acceleration. By performing a sequence of such simulations with different perturbation wavelengths, we generate a discrete dispersion spectrum for each of our examples and find that in all cases the linear RT growth-rate γ is well described by an expression of the form γ=α [kg/(1+ϵ kLm)]1/2−βkVa, where k is the perturbation wavenumber, g is the acceleration of the target, Lm is the minimum density scale-length, Va is the ablation velocity, and ϵ is either one or zero. The dimensionless coefficients α and β in the above formula depend on the particular target and laser parameters and are determined from two-dimensional simulation results through the use of a nonlinear curve-fitting procedure. While our findings are generally consistent with those of Betti et al. (Phys. Plasmas 5, 1446 (1998)), the ablative RT growth-rates predicted in this investigation are somewhat smaller than the values previously reported for the same target and laser parameters. It is speculated that differences in the equation-of-state and opacity models are largely responsible for the discrepancy. Resolution of this issue awaits the development of better experimental diagnostics capable of measuring small-wavelength (5–20 μm) perturbation growth due to the ablative RT instability in the linear regime.

Bates, J. W. (ORCID:0000000188087240)↗

Physics of picosecond pulse laser ablation

This study investigates the physical processes involved in picosecond pulse (20-28 ps FWHM) laser ablation of Al 6061, 316L stainless steel, and undoped crystalline Si ($\langle$100$\rangle$) over a range of laser wavelength (355 nm and 1064 nm) and fluence (0.1-40 J/cm 2 ). Experimental measurements of material ablation rate show enhanced removal at the 355 nm wavelength, primarily due to laser-plasma interaction (LPI) within the ablative plume that approaches an order of magnitude increase over the measured removal at 1064 nm. A transition in the ablation rate at 355 nm is identified around ~10 J/cm 2 above which the removal efficiency increases by a factor of two to three. Multi-physics radiation hydrodynamic simulations, considering LPI effects and utilizing a novel mixed-phase equation of state model, show that the transition in ablation efficiency is due to the onset of melt ejection through cavitation, where laser-driven shock heating sets the depth of melt penetration and the ensuing release wave from the ablation surface drives cavitation through the imposition of tensile strain within the melt. High-speed pump-probe imaging of the ejecta and ejecta collection studies, as well as scanning electron microscopy of the ablation craters, support the proposed cavitation mechanism in the higher fluence range. The ablation process is vitally influenced by LPI effects and the thermophysical properties of the material.

36 MATERIALS SCIENCE↗

Percutaneous Radiofrequency Lung Ablation Combined with Transbronchial Saline Injection: An Experimental Study in Swine

To evaluate the efficacy of radiofrequency lung ablation with transbronchial saline injection. The bilateral lungs of eight living swine were used. A 13-gauge bone biopsy needle was inserted percutaneously into the lung, and 1 ml of muscle paste was injected to create a tumor mimic. In total, 21 nodules were ablated. In the saline injection group (group A), radiofrequency ablation (RFA) was performed for 11 nodules after transbronchial saline injection under balloon occlusion with a 2-cm active single internally cooled electrode. In the control group (group B), conventional RFA was performed for 10 nodules as a control. The infused saline liquid showed a wedge-shaped and homogeneous distribution surrounding a tumor mimic. All 21 RFAs were successfully completed. The total ablation time was significantly longer (13.4 {+-} 2.8 min vs. 8.9 {+-} 3.5 min; P = 0.0061) and the tissue impedance was significantly lower in group A compared with group B (73.1 {+-} 8.8 {Omega} vs. 100.6 {+-} 16.6 {Omega}; P = 0.0002). The temperature of the ablated area was not significantly different (69.4 {+-} 9.1{sup o}C vs. 66.0 {+-} 7.9{sup o}C; P = 0.4038). There was no significant difference of tumor mimic volume (769 {+-} 343 mm{sup 3} vs. 625 {+-} 191 mm{sup 3}; P = 0.2783). The volume of the coagulated area was significantly larger in group A than in group B (3886 {+-} 1247 mm{sup 3} vs. 2375 {+-} 1395 mm{sup 3}; P = 0.0221). Percutaneous radiofrequency lung ablation combined with transbronchial saline injection can create an extended area of ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Ablation of High Intensity Focused Ultrasound with Microbubbles: An Experimental Study on Rabbit Hepatic VX2 Tumors

Purpose: This study was designed to assess the enhanced effect of high intensity focused ultrasound (HIFU) ablation with microbubbles on rabbit hepatic VX2 tumors and to compare the detection sensitivity of CEUS and CECT to determine the residual viable tissue after ablation of HIFU. Methods: Forty rabbits with hepatic VX2 tumors were randomly separated into two groups (20 animals per group) before HIFU ablation. A bolus of 0.2 mL of saline or a microbubble-based ultrasound (US) contrast agent was injected intravenously to group I rabbits and group II rabbits, respectively. The HIFU ablation procedure was started 15 s after the injection. Tumors were examined with grayscale contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) immediately before and after HIFU ablation. Histopathologic assessment was performed immediately after treatment imaging. Results: Before ablation, intense contrast enhancement during arterial phase was observed at the whole tumors or the periphery of the tumors by CEUS and CECT. Lower HIFU energy was used in group II than in group I (P < 0.001). Histopathologic assessment revealed local residual viable tumor tissues due to incomplete ablation in 47.4% (9/19) of tumors in group I and 10% (2/20) of tumors in group II (P < 0.05). The concordance rate of CEUS (90.9%) with histopathology on residual tumor detection was higher than that of CECT (27.3%, P < 0.05). Conclusions: Introduction of the microbubble agent enhances HIFU therapeutic efficacy. CEUS proves to have high sensitivity in assessment of residual viable rabbit VX2 tumor after HIFU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Percutaneous Irreversible Electroporation Lung Ablation: Preliminary Results in a Porcine Model

Objective: Irreversible electroporation (IRE) uses direct electrical pulses to create permanent 'pores' in cell membranes to cause cell death. In contrast to conventional modalities, IRE has a nonthermal mechanism of action. Our objective was to study the histopathological and imaging features of IRE in normal swine lung. Materials and Methods: Eleven female swine were studied for hyperacute (8 h), acute (24 h), subacute (96 h), and chronic (3 week) effects of IRE ablation in lung. Paired unipolar IRE applicators were placed under computed tomography (CT) guidance. Some applicators were deliberately positioned near bronchovascular structures. IRE pulse delivery was synchronized with the cardiac rhythm only when ablation was performed within 2 cm of the heart. Contrast-enhanced CT scan was performed immediately before and after IRE and at 1 and 3 weeks after IRE ablation. Representative tissue was stained with hematoxylin and eosin for histopathology. Results: Twenty-five ablations were created: ten hyperacute, four acute, and three subacute ablations showed alveolar edema and necrosis with necrosis of bronchial, bronchiolar, and vascular epithelium. Bronchovascular architecture was maintained. Chronic ablations showed bronchiolitis obliterans and alveolar interstitial fibrosis. Immediate post-procedure CT images showed linear or patchy density along the applicator tract. At 1 week, there was consolidation that resolved partially or completely by 3 weeks. Pneumothorax requiring chest tube developed in two animals; no significant cardiac arrhythmias were noted. Conclusion: Our preliminary porcine study demonstrates the nonthermal and extracellular matrix sparing mechanism of action of IRE. IRE is a potential alternative to thermal ablative modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Intraoperative Nerve Monitoring in Preventing Thermal Damage to the “Nerve at Risk” During Image-Guided Ablation of Tumors

PurposeTo assess feasibility of intraoperative neurophysiologic monitoring (IONM) during image-guided, percutaneous thermal ablation of tumors.Materials and MethodsFrom February 2009 to October 2013, a retrospective review of all image-guided percutaneous thermal ablation interventions using IONM was performed and data was compiled using electronic medical records and imaging studies.ResultsTwelve patients were treated in 13 ablation interventions. In 4 patients, real-time feedback from the monitoring neurologist was used to adjust applicator placement and ablation settings. IONM was technically feasible in all procedures and there were no complications related to monitoring or ablation. All nerves at risk remained intact and of the 11 patients who could be followed, none developed new nerve deficit up to a minimum of 2 months after ablation.ConclusionIONM is safe and feasible for use during image-guided thermal ablation of tumors in the vicinity of nerves. Outcomes in this study demonstrate its potential utility in image-guided ablation interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Results of Ultrasonography-Guided Percutaneous Radiofrequency Ablation in Hyperparathyroid Patients in Whom Surgery Is Not Feasible

BackgroundThe aim of the study was to evaluate the results of ultrasonography (US)-guided percutaneous radiofrequency ablation (RFA) in hyperparathyroid patients who refused surgery or had high surgical risks.Patients and MethodsFive patients with hyperparathyroidism (HPT) underwent US-guided RFA for a single hyperfunctioning parathyroid lesion. Post-ablation serum calcium and parathormone (PTH) assays were performed. All patients underwent imaging studies 6 months after the ablation to visualize the post-ablation change in the size of the treated parathyroid lesions.ResultsAll patients were normocalcemic on the post-ablation 1st day and 6th month. The post-ablation PTH levels were normal in three patients but remained elevated in two patients. The size of the parathyroid lesion was ≥30 mm in the two patients with elevated PTH, whereas the lesion was smaller than 30 mm in those with normal post-ablation PTH values.ConclusionAlthough this is a limited case series, it demonstrates the potential feasibility of RFA for HPT. Benefits were achieved particularly in patients with small parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared laser ablation of poly(vinylidene fluoride): The Loss of HF

The mechanism and kinetics of infrared laser ablation of poly(vinylidene fluoride) (PVDF) in vacuum have been investigated to understand how this can be used as a polymer processing technology. The laser heats the surface and initiates decomposition of macromolecules in the molten polymer layer which rapidly leads to production of an ablative flow of polymer decomposition products. There is only a short induction period of up to 2 s before ablation begins. After the initial period, the rate of mass loss increases linearly with the time of laser exposure. Spherical particles with an average diameter of about 100 nm are formed on the surface of the powder coating obtained by laser ablation. Here, the particle distribution ranges from 50 nm to 300 nm. The main gaseous product of ablation is HF from dehydrofluorination. A second important ablation process is the formation of gaseous carbenes generated during secondary reactions. Proposed ablation reactions due to laser-induced thermal dehydrofluorination occur in two stages. In the first stage, a double bond appears in PVDF due to direct loss of HF. Subsequent detachment of HF leads to the appearance of both triple bonds and cumulene bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct reuse of graphite and lithium nickel manganese cobalt oxide (NMC) recovered from ultrafast-laser ablation debris in Li-ion battery electrodes

Here we demonstrate that debris collected from the ultrafast-laser ablation of graphite anodes can be directly reused in a lithium-ion battery with little to no negative effects on electrochemical performance. Further, we show that while post-ablation NMC (LiNi 0.33 Mn 0.33 Co 0.33 O) cathode debris will require additional processing before being incorporated into an electrode, its critical materials (nickel, manganese, and cobalt) are not lost during ablation and can be recovered for recycling. Pre- and post-ablation materials are characterized with a suite of diagnostics, including SEM, TEM, X-ray CT, EDS, and XRD, to study changes in material morphology, composition and crystal structure. Graphite exhibited little to no morphological or compositional changes and a slight annealing of its crystal structure. NMC underwent profound morphological and crystallographic changes, but retained its elemental composition. Finally, post-ablation materials were re-manufactured into electrodes and cycled vs lithium metal. Graphite showed equal or better capacity and Coulombic efficiency compared to pre-ablation electrodes, while the post-ablation NMC exhibited severely reduced electrochemical performance. Furthermore, we discuss the outlook for application of this work to advanced manufacturing lines that produce next-generation, laser-patterned electrodes.

25 ENERGY STORAGE↗

A plasma model combined with an improved two-temperature equation for ultrafast laser ablation of dielectrics

It remains a big challenge to theoretically predict the material removal mechanism in femtosecond laser ablation. To bypass this unresolved problem, many calculations of femtosecond laser ablation of nonmetals have been based on the free electron density distribution without the actual consideration of the phase change mechanism. However, this widely used key assumption needs further theoretical and experimental confirmation. By combining the plasma model and improved two-temperature model developed by the authors, this study focuses on investigating ablation threshold fluence, depth, and shape during femtosecond laser ablation of dielectrics through nonthermal processes (the Coulomb explosion and electrostatic ablation). The predicted ablation depths and shapes in fused silica, by using (1) the plasma model only and (2) the plasma model plus the two-temperature equation, are both in agreement with published experimental data. The widely used assumptions for threshold fluence, ablation depth, and shape in the plasma model based on free electron density are validated by the comparison study and experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparisons of kinetic ablation models for the capillary discharge

The properties of kinetic ablation models are considered in this paper. The widely used kinetic ablation model (model-K) only considers monatomic vapor. A revised model (model-Z) was introduced by taking into account the polyatomic vapor's internal degrees of freedom, as well as the temperature dependence of the average particle mass. In this work, both temperature and pressure dependence of average particle mass and the specific heat ratio {gamma} are taken into account, producing an improved version of model-Z (denoted model-Z{sup *}). Ablation data calculated by model-K and model-Z* for two typical capillary materials are presented. Compared to model-K, model-Z* predicts an increased ablation rate at lower plasma temperature and higher plasma density, and a decreased rate for the opposite conditions. Finally, based on the plasma parameters in a typical discharge cycle, all three models are used to calculate the time-dependent ablation rate and the integrated ablated mass. It is found that the main difference between their results arises because of the different average particle masses near the wall surface, and model-Z* is the most accurate for the discharge cycle considered. Further, it is found that the ablation parameters are highly sensitive to the pressure, in particular, through the pressure dependence of average particle mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-tracer spectroscopy diagnostics of temperature profile in the conduction layer of a laser-ablated plastic foil

A technique that combines the diagnostics of electron temperature history and the measurements of ablation velocity with two-tracer x-ray spectroscopy has been developed for diagnosing the temperature profiles in the thermal conduction layers of laser-ablated plastic foils. The electron temperature in the plastic ablator was diagnosed using the isoelectronic line ratios of Al Ly{alpha} line to Mg Ly{alpha} line, emitted from a tracer layer of Al/Mg mixture buried under the ablator. The ablation velocity was inferred from the time delay between the onset time of x-ray line emissions from Al and Mg tracer layers buried at two depths in the ablator, respectively. From the measured electron temperatures and ablation velocity, the electron temperature profile in the conduction layer was inferred. The measured temperature profile was compared with the simulated one and reasonable agreement was found.

36 MATERIALS SCIENCE↗