Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Virtual Diagnostic Suite for Electron Beam Prediction and Control at FACET-II

We discuss the implementation of a suite of virtual diagnostics at the FACET-II facility currently under commissioning at SLAC National Accelerator Laboratory. The diagnostics will be used for the prediction of the longitudinal phase space along the linac, spectral reconstruction of the bunch profile, and non-destructive inference of transverse beam quality (emittance) while using edge radiation at the injector dogleg and bunch compressor locations. These measurements will be folded into adaptive feedbacks and Machine Learning (ML)-based reinforcement learning controls to improve the stability and optimize the performance of the machine for different experimental configurations. In this paper we describe each of these diagnostics with expected measurement results that are based on simulation data and discuss progress towards implementation in regular operations.

Emma, Claudio (ORCID:0000000247191831)↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Beam impedance and heating analysis of the diagnostic stripline

In this work the heat transfer analysis has been performed for the stripline kicker, design of which is used at many accelerator facilities as a part of the transverse bunch-by-bunch feed-back system, including NSLS-II. The experimental data of the electrode temperature have been collected from a special diagnostic stripline designed with six infrared view ports. The temperature analysis is based on the power loss calculations and the loss factor computed by the 3-D electromagnetic simulation code GdfidL. To estimate the power loss, we analyze the real part of the longitudinal impedance and the loss factor for two different regimes. We use the ANSYS finite element code to correlate the temperature with the power loss. Lambertson and Shafer formalisms of the longitudinal and transverse beam impedances are discussed for the simplified stripline geometries. The required characteristic impedances and the geometric factors are determined analytically for the simplified geometries and compared with the results for the designed stripline geometry using the 2-D POISSON code by solving the Laplace’s equation in two dimensions. Lambertson’s equations are compared with numerical results. We introduce the frequency range, within which we can apply the analytical approach.

43 PARTICLE ACCELERATORS↗

Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics

A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize those properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. As a result, the improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.

43 PARTICLE ACCELERATORS↗

Geant4 Simulations on Faraday Cup Design for PIP-II Laser Wire Scanner System

The Proton Improvement Plan-II (PIP-II) accelerator upgrade at Fermilab represents a groundbreaking leap forward in high-energy physics research. This ambitious initiative involves enhancing Fermilab's accelerator complexby replacing the current linear accelerator (linac) with awarm front end (WFE) capable of accelerating H- beamsup to 2.1 MeV. Subsequently, a superconducting linac further accelerates these beams up to 800 MeV. To preciselymeasure the transverse beam profile, a combination of traditional wire scanners at the WFE section and Laser wirescanners along the superconducting linac are planned forimplementation. This investigation is centered on refiningthe Faraday cup design for the PIP-II Laser wire scannersby utilizing GEANT4, a Monte Carlo simulation toolkit.Leveraging this method enables a comprehensive analysisof particle trajectories, energy deposition, secondary particle emission, backscattering, etc., facilitating optimizationthrough adjustments to cup geometries, materials, andplacement to maximize its efficacy in beam diagnostics.

43 PARTICLE ACCELERATORS↗

Revealing the three-dimensional structure of microbunched plasma-wakefield-accelerated electron beams

Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Opportunities for Space Station wave experiments

The solar terrestrial observatory (STO) concept is discussed as well as Space Station accommodations for STO. Instruments for the initial STO which can be used to excite and detect waves include the electrodynamic tether, waves in space plasmas, space experiments with particle accelerators, vehicle charge and potential experiments, recoverable plasma diagnostics package, magnetospheric multiprobes, and theoretical and experimental beam plasma physics. An example is given of a typical campaign mode of operation which is appropriate for active experiments.

Shawhan, Stanley D.↗

Demonstration of Autonomous Emittance Characterization at the Argonne Wakefield Accelerator

Transverse beam emittance plays a key role in the performance of high-brightness accelerators. Characterizing beam emittance is often carried out using a quadrupole scan, which fits beam matrix elements to experimental measurements using first-order beam dynamics. Despite its simplicity at face value, this procedure is difficult to automate due to practical limitations. Key issues that must be addressed include maintaining beam size measurement validity by keeping beams within the radius of diagnostic screens, ensuring that measurement fitting produces physically valid results, and accurately characterizing emittance uncertainty. We describe a demonstration of the Bayesian exploration technique towards solving this problem at the Argonne Wakefield Accelerator, enabling a turn-key, autonomous quadrupole scan tool that can be used to quickly measure beam emittances at various locations in accelerators with limited operator input.

Roussel, Ryan↗

Enhanced Beam Diagnostics with Existing BPPMs via GPU-powered Multi-Particle Simulation

This research aims to utilize the multi-particle code, High-Performance Simulator (HPSim), to realistically model the Side-Coupled-Cavity Linac (CCL) lattice of the LANSCE accelerator. This new model would allow us to predict the beam’s bunch length (the longitudinal spread), which is unavailable for individual accelerating modules or only accessible at the end of the linac. However, a correct bunch length is critical for the high-energy beam transport after the CCL. Its impact would be most significant in the Proton Storage Ring (PSR), where we should be able to reduce losses for the circulating beam. The PSR is scheduled to have a 25% current increase for the neutron spallation target upgrade at the Lujan Center. A highly bunched beam would be necessary to reduce the particle losses and lower the radiation levels produced from the ring. A realistic HPSim model with >1M macro-particles can help tackle the beam losses at the sub-percent level. This new work would also create a realistic surrogate model for future machine learning projects.

43 PARTICLE ACCELERATORS↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗

Measurement and Control of Beam Energy at the Fermilab 400 MeV Transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped of the extra electrons to become protons. Tuning Linac is performed using diagnostics to ensure stable intensity and energy while minimizing uncontrolled particle loss. I have been revisiting diagnostics in the Linac in order to understand their signals and to ensure their data is reliable. I revisited Beam Loss Monitors (BLMs) for the loss data confidence. For the confidence of energy data there were two approaches. The first approach was time-of-flight measurements using Beam Position Monitors (BPMs) and beam velocity stripline pick-up that provides beam phase data. The second approach used the relation between beam position data from BPMs and dispersion values from MAD-X simulation to calculate energy. Our goal after understanding the data from the Linac diagnostics and finding the data reliable is to control the L inac parameters using Machine Learning techniques to increase the reliability and quality of beam delivered from Linac.

43 PARTICLE ACCELERATORS↗

Real-Time Data Acquisition and Processing System for MHz Repetition Rate Image Sensors

An electro-optic detector is one of the diagnostic setups used in particle accelerators. It employs an electro-optic crystal to encode the longitudinal beam charge profile in the spectrum of a light pulse. The charge distribution is then reconstructed using data captured by a fast spectrometer. The measurement repetition rate should match or exceed the machine bunching frequency, which is often in the range of several MHz. A high-speed optical line detector (HOLD) is a linear camera designed for easy integration with scientific experiments. The use of modern FPGA circuits helps in the efficient collection and processing of data. The solution is based on Xilinx 7-Series FPGA circuits and implements a custom latency-optimized architecture utilizing the AXI4 family of interfaces. HOLD is one of the fastest line cameras in the world. Thanks to its hardware architecture and a powerful KALYPSO sensor from KIT, it outperforms the fastest comparable commercial devices.

MicroTCA↗