Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerometers accelerometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

137 records · Page 8

Phaeton Mast Dynamics: On-Orbit Characterization of Deployable Masts

The PMD instrument is a set of three custom-designed triaxial accelerometer systems designed specifically to detect and characterize the modal dynamics of deployable masts in orbit. The instrument was designed and built as a payload for the NuSTAR spacecraft, but it is now sponsored by the Air Force Research Laboratory's DSX project. It can detect acceleration levels from 1 micro gram to 0.12g over a frequency range of 0.1Hz to 30Hz, the results of which can support future modeling and designing of deployable mast structures for space. This paper details the hardware architecture and design, calibration test and results, and current status of the PMD instrument.

Phaeton Mast Dynamics (PMD)↗

An Overview of the Source Physics Experiment at the Nevada National Security Site (SPE-N)

Understanding the changes in seismic energy as it travels from the near field to the far field is the ultimate goal in monitoring for explosive events of interest. This requires a clear understanding of explosion phenomenology as it relates to seismic, infrasound, and acoustic signals. Although there has been much progress in modeling these phenomena, this has been primarily based in the empirical realm. As a result, the logical next step in advancing the seismic monitoring capability of the United States is to conduct field tests that can expand the predictive capability of the physics-based modeling currently under development. The Source Physics Experiment at the Nevada National Security Site (SPE-N) is the first step in this endeavor to link the empirically based with the physics-based modeling. This is a collaborative project between National Security Technologies (NSTec), Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), the Defense Threat Reduction Agency (DTRA), and the Air Force Technical Applications Center (AFTAC). The test series require both the simple and complex cases to fully characterize the problem, which is to understand the transition of seismic energy from the near field to the far field; to understand the development of S-waves in explosives sources; and how anisotropy controls seismic energy transmission and partitioning. The current series is being conducted in a granite body called the Climax Stock. This location was chosen for several reasons, including the fairly homogenous granite; the location of previous nuclear tests in the same rock body; and generally the geology has been well characterized. The simple geology series is planned for 7 shots using conventional explosives in the same shot hole surrounded by Continuous Reflectometry for Radius vs. Time Experiment (CORRTEX), Time of Arrival (TOA), Velocity of Detonation (VOD), down-hole accelerometers, surface accelerometers, infrasound, and a suite of seismic sensors of various frequency bands from the near field to the far field. This allows for the use of a single test bed in the simple geology case instead of multiple tests beds to obtain the same results. The shots are planned at various depths to obtain a Green’s function, scaled-depth of burial data, nominal depth of burial data and damage zone data. SPE1-N was conducted in May 2011 as a 220 lb (100 kg) TNT equivalent calibration shot at a depth of 180 ft (55 m). SPE2-N was conducted in October 2011 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m). SPE3-N was conducted in July 2012 as a 2200 lb (1000 kg) TNT equivalent calibration shot at a depth of 150 ft (46 m) in the damaged zone. Over 400 data channels were recorded for each of these shots and data recovery was about 95% with high signal to noise ratio. Once the simple geology site data has been utilized, a new test bed will be developed in a complex geology site to test these physics based models. Ultimately, the results from this project will provide the next advances in the science of monitoring to enable a physics-based predicative capability.

Source record↗

Preliminary efforts toward development of data handling and analysis software for unsteady flow measurements: An application for aeroelastic transonic flow configurations

A few years ago the Structural Dynamics Division at LaRC started ambitious experimental research efforts known as the Benchmark Models Program. The primary objective of this program was to provide experimental data that may serve as a calibration source for computational fluid dynamics (CFD) efforts that deal with aeroelastic unsteady flow configurations. It also focuses on the understanding of complex flow phenomenon associated with unsteady flow developments. The overall plan for the program has been described by Bennett, including a presentation of initial test results of flutter of a rigid wing mounted on flexible supports. An example of a test model employed to measure the dynamic response along with corresponding pressure distributions is shown. This model incorporates eighty pressure transducers distributed along two spanwise stations. In addition, the models are equipped with four accelerometers and two strain gages. The data handling system for the Benchmark Model Program is under development. Several interactive computer routines designed for the user interface, dynamic memory allocation, unsteady flow measurements data extraction, and further data processing were developed. To present a few examples of measured data, the unsteady pressure distributions and the wing model dynamic response were plotted.

Finaish, Fathi↗

Development of Unsteady Pressure-Sensitive Paint Application on NASA Space Launch System

The key measurement to acquire for understanding unsteady flow is surface pressure. Unsteady Pressure-Sensitive Paint (uPSP) is an emerging optical technique used in wind tunnel testing to measure fluctuating surface pressures. Recently, tests were conducted on NASA’s Space Launch System in NASA Ames Research Center’s Unitary Plan Wind Tunnel to determine the aeroacoustics environment and assist in developing the buffet forcing functions. Unsteady PSP data was collected during this test campaign. Steady state PSP data, infrared thermography, shadowgraph, accelerometer data, and dynamic pressure transducer data were also collected. In all 50 TB of data were collected during the three days of testing. During these three days of testing, a repeating transonic and supersonic alpha sweep condition was acquired. This paper presents these two wind tunnel conditions and examines how the temperature influences the PSP data. In the first large demonstration of uPSP in 2015 on an NESC-, AETC-sponsored wind tunnel test, lifetime PSP results highlighted the influence the model temperature had on the PSP data. A best practice of heat soaking the model before acquiring calibration images was followed during the test campaign presented in this paper. An infrared thermography camera and thermocouples were installed in the model to collect more details of the model surface temperature. Data processing schemes for uPSP are still in development but will be briefly presented here as well.

Roozeboom, Nettie H.↗

An Overview of the Mars Reconnaissance Orbiter (MRO) Science Mission

The Mars Reconnaissance Orbiter (MRO) is the latest addition to the suite of missions on or orbiting Mars as part of the NASA Mars Exploration Program. Launched on 12 August 2005, the orbiter successfully entered Mars orbit on 10 March 2006 and finished aerobraking on 30 August 2006. Now in its near-polar, near-circular, low-altitude (approximately 300 km), 3 p.m. orbit, the spacecraft is operating its payload of six scientific instruments throughout a one-Mars-year Primary Science Phase (PSP) of global mapping, regional survey, and targeted observations. Eight scientific investigations were chosen for MRO, two of which use either the spacecraft accelerometers or tracking of the spacecraft telecom signal to acquire data needed for analysis. Six instruments, including three imaging systems, a visible-near infrared spectrometer, a shallow-probing subsurface radar, and a thermal-infrared profiler, were selected to complement and extend the capabilities of current working spacecraft at Mars. Whether observing the atmosphere, surface, or subsurface, the MRO instruments are designed to achieve significantly higher resolution while maintaining coverage comparable to the current best observations. The requirements to return higher-resolution data, to target routinely from a low-altitude orbit, and to operate a complex suite of instruments were major challenges successfully met in the design and build of the spacecraft, as well as by the mission design. Calibration activities during the seven-month cruise to Mars and limited payload operations during a three-day checkout prior to the start of aerobraking demonstrated, where possible, that the spacecraft and payload still had the functions critical to the science mission. Two critical events, the deployment of the SHARAD radar antenna and the opening of the CRISM telescope cover, were successfully accomplished in September 2006. Normal data collection began 7 November 2006 after solar conjunction. As part of its science mission, MRO will also aid identification and characterization of the most promising sites for future landed missions, both in terms of safety and in terms of the scientific potential for future discovery. Ultimately, MRO data will advance our understanding of how Mars has evolved and by which processes that change occurs, all within a framework of identifying the presence, extent, and role of water in shaping the planet s climate over time.

astronomical instruments↗

Orbiter Aerodynamic Acceleration Flight Measurements in the Rarefied-Flow Transition Regime

Acceleration data taken from the Orbital Acceleration Research Experiment (OARE) during reentry on STS-62 have been analyzed using calibration factors taken on orbit. This is the first Orbiter mission which collected OARE data during the Orbiter reentry phase. The data examined include the flight regime from orbital altitudes down to about 90 km which covers the free-molecule-flow regime and the upper altitude fringes of the rarefied-flow transition into the hypersonic continuum. Ancillary flight data on Orbiter position, orientation, velocity, and rotation rates have been used in models to transform the measured accelerations to the Orbiter center-of-gravity, from which aerodynamic accelerations along the Orbiter body axes have been calculated. Residual offsets introduced in the measurements by unmodeled Orbiter forces are identified and discussed. Direct comparisons are made between the OARE flight data and an independent micro-gravity accelerometer experiment, the High Resolution Accelerometer Package (HiRAP), which also obtained flight data on reentry during the mission down to about 95 km. The resulting OARE aerodynamic acceleration measurements along the Orbiter's body axis, aid the normal to axial acceleration ratio in the free-molecule-flow and transition-flow regimes are presented and compared with numerical simulations from three direct simulation Monte Carlo codes.

Blanchard, Robert C.↗

RL-34 ring laser gyro laboratory evaluation for the Deep Space Network antenna application

The overall results of this laboratory evaluation are quite encouraging. The gyro data is in good agreement with the system's overall pointing performance, which is quite close to the technical objectives for the Deep Space Network (DSN) application. The system can be calibrated to the levels required for millidegree levels of pointing performance, and initialization performance is within the required 0.001 degree objective. The blind target acquisition performance is within a factor of two of the 0.0001 degree objective, limited only by a combination of the slow rate (0.5 deg/sec) and the existing production quantization logic (0.38 arc-sec/pulse). Logic circuitry exists to better this performance such that it will better the objective by 50 percent. Representative data with this circuitry has been provided for illustration. Target tracking performance is about twice the one millidegree objective, with several factors contributing. The first factor is the bias stability of the gyros, which is exceptional, but will limit performance to the 0.001 and 0.002 degree range for long tracking periods. The second contributing factor is the accelerometer contributions when the system is elevated. These degrade performance into the 0.003 to 0.004 degree range, which could be improved upon with some additional changes. Finally, we have provided a set of recommendations to improve performance closer to the technical objectives. These recommendations include gyro, electronics, and system configurational changes that form the basis for additional work to achieve the desired performance. In conclusion, we believe that the RL-34 ring laser gyro-based advanced navigation system demonstrated performance consistent with expectations and technical objectives, and it has the potential for even further enhancement for the DSN application.

Source record↗

PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS

The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel bar reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.

36 MATERIALS SCIENCE↗

Variable Acceleration Force Calibration System (VACS)

Conventionally, force balances have been calibrated manually, using a complex system of free hanging precision weights, bell cranks, and/or other mechanical components. Conventional methods may provide sufficient accuracy in some instances, but are often quite complex and labor-intensive, requiring three to four man-weeks to complete each full calibration. To ensure accuracy, gravity-based loading is typically utilized. However, this often causes difficulty when applying loads in three simultaneous, orthogonal axes. A complex system of levers, cranks, and cables must be used, introducing increased sources of systematic error, and significantly increasing the time and labor intensity required to complete the calibration. One aspect of the VACS is a method wherein the mass utilized for calibration is held constant, and the acceleration is changed to thereby generate relatively large forces with relatively small test masses. Multiple forces can be applied to a force balance without changing the test mass, and dynamic forces can be applied by rotation or oscillating acceleration. If rotational motion is utilized, a mass is rigidly attached to a force balance, and the mass is exposed to a rotational field. A large force can be applied by utilizing a large rotational velocity. A centrifuge or rotating table can be used to create the rotational field, and fixtures can be utilized to position the force balance. The acceleration may also be linear. For example, a table that moves linearly and accelerates in a sinusoidal manner may also be utilized. The test mass does not have to move in a path that is parallel to the ground, and no re-leveling is therefore required. Balance deflection corrections may be applied passively by monitoring the orientation of the force balance with a three-axis accelerometer package. Deflections are measured during each test run, and adjustments with respect to the true applied load can be made during the post-processing stage. This paper will present the development and testing of the VASC concept.

Rhew, Ray D.↗

Comments on SEE: Comparative Advantages and and Experimental Consequences

The Satellite Energy Exchange experiment measures the periodic, near-miss encounters between a sheppard satellite and a small test body (satellite) in approximately the same orbit about a primary. Several important experimental requirements have been chosen to enhance capabilities: (a) The satellite be flown in a sun-synchronous orbit at an altitude of about 1350 Km, (b) Passive temperature system stabilized by spacecraft axial rotation with sunshade baffles at the end of the spacecraft, (c) Test bodies with different material composition be available for experiments, (d) The containment spacecraft fly about the sheppard mass in a zero-g environment whereas the test bodies, experience average zero-g environment over an orbital period, (e) Primary attitude and station-keeping uses magnetic field alignment plus micro-Newton thrusters such as Field Emission Electric Propulsion, and (f) Very low power (nW) laser tracking systems minimize impulse delivered to test bodies. With the above conditions, SEE has the capabilities: (1) Long duration (several years life-time) flight experiment (2) Long-term, active (with historical time record), self-calibration of satellite mass distribution (capsule geodesy) over lifetime of the spacecraft. (3) Novel passive thermal stabilization systems designed to attain cryogenic temperatures around 78K. (4) Novel spacecraft stabilization systems. (5) Ability to measure G to 1 part in 10(exp 6-7) depending on ultimate duration of experiment. (6) Ability to place limits on both temporal and spacial variations on G. (7) Ability to set experimental limits on the Post Newtonian parameters (PPN) alpha(2) and zeta(2). (8) Ability to measure (or place limits on) the non Einsteinian eccentricity of the Earth-Sun system (and the parameter alpha(1)) for long duration flight. (9) Ability to measure Delta((dot)-G)/G to 1 part in 10(exp 12-13). The MiniSTEP, competes in a limited way with Project SEE. It is designed to improve the measurement of the equivalence principle by seven orders of magnitude using active, low temperature (1.8 K) cooling for SQUID based, differential superconducting circuits. The experiment consists of a small cylinder concentrically located within a larger cylinder at its null gravitational point. The satellite is operated in zero-g mode using four differential accelerometers consisting to two test bodies of different material composition. The SQUIDS are needed to measure test body motion to precisions of 10(exp -18) over a four orbit period. The entire satellite moves in a very precise zero-g mode since the accelerometers are rigidly attached to the satellite. This limits the experiment to an approximately six month due to limitations on helium storage used in cryogenic cooling and thrust control to maintain the zero-g operation.

Smalley, Larry L.↗

Comparison of sleep parameters from wrist-worn ActiGraph and Actiwatch devices

Abstract Sleep and physical activity, two important health behaviors, are often studied independently using different accelerometer types and body locations. Understanding whether accelerometers designed for monitoring each behavior can provide similar sleep parameter estimates may help determine whether one device can be used to measure both behaviors. Three hundred and thirty one adults (70.7 ± 13.7 years) from the Baltimore Longitudinal Study of Aging wore the ActiGraph GT9X Link and the Actiwatch 2 simultaneously on the non-dominant wrist for 7.0 ± 1.6 nights. Total sleep time (TST), wake after sleep onset (WASO), sleep efficiency, number of wake bouts, mean wake bout length, and sleep fragmentation index (SFI) were extracted from ActiGraph using the Cole–Kripke algorithm and from Actiwatch using the software default algorithm. These parameters were compared using paired t-tests, Bland–Altman plots, and Deming regression models. Stratified analyses were performed by age, sex, and body mass index (BMI). Compared to the Actiwatch, the ActiGraph estimated comparable TST and sleep efficiency, but fewer wake bouts, longer WASO, longer wake bout length, and higher SFI (all p < .001). Both devices estimated similar 1-min and 1% differences between participants for TST and SFI (β = 0.99, 95% CI: 0.95, 1.03, and 0.91, 1.13, respectively), but not for other parameters. These differences varied by age, sex, and/or BMI. The ActiGraph and the Actiwatch provide comparable absolute and relative estimates of TST, but not other parameters. The discrepancies could result from device differences in movement collection and/or sleep scoring algorithms. Further comparison and calibration is required before these devices can be used interchangeably.

Liu, Fangyu (ORCID:0000000315541478)↗