Search NASA⌕ Search

SEARCH · Search NASA

Results for “acquisition function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nonlinear drought plasticity reveals intraspecific diversity in a dominant grass species

Abstract Intraspecific diversity of dominant species in native plant communities can modulate ecosystem function under both optimal and stressful conditions. Yet, few genotype by environment interaction studies quantify differences in the shape of plasticity functions or phenotypic breakpoints across genotypes in natural populations. Using three genotypes with a history of drought selection, we performed a greenhouse study on the dominant tallgrass prairie species Andropogon gerardii . We investigated phenotypic plasticity and recovery differences among genotypes across a water availability gradient, measuring growth‐related, instantaneous and cumulative phenotypes. To further understand genotype by environment effects, we quantified plasticity functions and breakpoints among genotypes. Like other studies, we found strong evidence for phenotypic and plasticity differences among genotypes. However, we also found nonlinear plasticity functions and breakpoints were common across phenotypes, especially relative growth rates, biomass allocation and root architecture. Drought selected genotypes were also more likely to flower during recovery, but all genotypes were resilient to drought across treatments. We demonstrate that plasticity functions may help explain intraspecific diversity, patterns of selection and nonlinear community responses to more variable rainfall within an experimental population. In particular, plasticity functions can help disentangle drought/variability tolerance versus acquisitive strategies. A better understanding of intraspecific diversity in this grass species will provide more mechanistic insight into its ability to buffer ecosystem changes and provide resiliency in the tallgrass prairie under future droughts. A free Plain Language Summary can be found within the Supporting Information of this article.

Hoffman, Ava M.↗

Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-12: Toward Patient-Specific 4DCT Reconstruction Using Adaptive Velocity Binning

Purpose: While 4DCT provides organ/tumor motion information, it often samples data over 10–20 breathing cycles. For patients presenting with compromised pulmonary function, breathing patterns can change over the acquisition time, potentially leading to tumor delineation discrepancies. This work introduces a novel adaptive velocity-modulated binning (AVB) 4DCT algorithm that modulates the reconstruction based on the respiratory waveform, yielding a patient-specific 4DCT solution. Methods: AVB was implemented in a research reconstruction configuration. After filtering the respiratory waveform, the algorithm examines neighboring data to a phase reconstruction point and the temporal gate is widened until the difference between the reconstruction point and waveform exceeds a threshold value—defined as percent difference between maximum/minimum waveform amplitude. The algorithm only impacts reconstruction if the gate width exceeds a set minimum temporal width required for accurate reconstruction. A sensitivity experiment of threshold values (0.5, 1, 5, 10, and 12%) was conducted to examine the interplay between threshold, signal to noise ratio (SNR), and image sharpness for phantom and several patient 4DCT cases using ten-phase reconstructions. Individual phase reconstructions were examined. Subtraction images and regions of interest were compared to quantify changes in SNR. Results: AVB increased signal in reconstructed 4DCT slices for respiratory waveforms that met the prescribed criteria. For the end-exhale phases, where the respiratory velocity is low, patient data revealed a threshold of 0.5% demonstrated increased SNR in the AVB reconstructions. For intermediate breathing phases, threshold values were required to be >10% to notice appreciable changes in CT intensity with AVB. AVB reconstructions exhibited appreciably higher SNR and reduced noise in regions of interest that were photon deprived such as the liver. Conclusion: We demonstrated that patient-specific velocity-based 4DCT reconstruction is feasible. Image noise was reduced with AVB, suggesting potential applications for low-dose acquisitions and to improve 4DCT reconstruction for irregular breathing patients. The submitting institution holds research agreements with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Radiation-Hardened Circuitry Using Mask-Programmable Analog Arrays. Final Report

As the recent accident at Fukushima Daiichi so vividly demonstrated, telerobotic technologies capable of withstanding high radiation environments need to be readily available to enable operations, repair, and recovery under severe accident scenarios where human entry is extremely dangerous or not possible. Telerobotic technologies that enable remote operation in high dose rate environments have undergone revolutionary improvement over the past few decades. However, much of this technology cannot be employed in nuclear power environments due the radiation sensitivity of the electronics and the organic insulator materials currently in use. This is the final report of the activities involving the NEET 2 project Radiation Hardened Circuitry Using Mask-Programmable Analog Arrays. We present a detailed functional block diagram of the proposed data acquisition system, the thought process leading to technical decisions, the implemented system, and the tested results from the systems. This system will be capable of monitoring at least three parameters of importance to nuclear reactor monitoring: temperature, radiation level, and pressure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INFORMATION: Special Report on "Selected Department of Energy Program Efforts to Implement the American Recovery and Reinvestment Act"

The American Recovery and Reinvestment Act of 2009 (Recovery Act) was enacted on February 17, 2009, to jumpstart the economy by creating or saving millions of jobs, spurring technological advances in health and science, and investing in the Nation's energy future. The Department of Energy received over $32.7 billion in Recovery Act funding for various science, energy, and environmental programs and initiatives. As of November 2009, the Department had obligated $18.3 billion of the Recovery Act funding, but only $1.4 billion had been spent. The Department's Offices of Energy Efficiency and Renewable Energy, Fossil Energy, Environmental Management, Science, and Electricity Delivery and Energy Reliability received the majority of funding allocated to the Department, about $32.3 billion. Obligating these funds by the end of Fiscal Year 2010, as required by the Recovery Act, and overseeing their effective use in succeeding years, represents a massive workload increase for the Department's programs. The effort to date has strained existing resources. As has been widely acknowledged, any effort to disburse massive additional funding and to expeditiously initiate and complete projects increases the risk of fraud, waste and abuse. It is, therefore, important for the Department's program offices to assess and mitigate these risks to the maximum extent practicable. In this light, we initiated this review as an initial step in the Office of Inspector General's charge to determine whether the Department's major program offices had developed an effective approach for identifying and mitigating risks related to achieving the goals and objectives of the Recovery Act. The Department's program offices included in our review identified risks and planned mitigation strategies that, if successfully implemented and executed, should help achieve the goals and objectives of the Recovery Act. While each office identified risks unique to its respective areas of responsibility, there were a number of risks shared in common. These included the mechanical and substantive requirements related to the award and distribution of funds; program and project performance monitoring; and, program and project execution activities. In particular, the offices self-identified common risks such as: (1) The inability to award and distribute funds in a timely manner to achieve the goals of the Recovery Act; (2) The sufficiency of monitoring procedures and resources to, among other things, prevent and detect fraud, waste and abuse throughout the performance period of financial assistance awards and contracts; and (3) The inherent cost, schedule and performance risks associated with first-of-a-kind, innovative research and demonstration projects. Our review confirmed that the Department had begun to implement a number of strategies designed to mitigate these and other program-specific risks. Our testing, however, identified challenges to the effective implementation of these mitigation strategies that need to be addressed if the Department is to meet the goals and objectives established by the Recovery Act. At the time of our review: (1) Program staffing resources, critical to the success of all other mitigation strategies, remained inadequate both in numbers and qualifications (certifications and training) for positions in procurement and acquisition, project management, and monitoring and oversight functions; (2) Performance measures for achieving Recovery Act goals such as distributing funds in an expeditious manner had not always been established and included in performance plans, and, in financial assistance and contract documents; and (3) Programs had not consistently demonstrated that previously reported deficiencies, identified through audits, inspections, investigations and other oversight activities, had been considered in designing mitigation strategies for the Recovery Act related risks. As we noted in our Special Report on the American Recovery and Reinvestment Act at the Department of Energy (OAS-RA-09-01, March 2009) these sorts of deficiencies, which were described in the March 2009 report, had adversely impacted the success of earlier Departmental projects. We concluded that consideration of these previously encountered internal control weaknesses was essential if the Department was to avoid the same or similar problems in executing the Recovery Act programs/projects. During the course of our audit we identified other internal control weakness indicators. When brought to their attention by the Office of Inspector General audit staff, program officials acted promptly to address these problems by modifying or improving their risk mitigation strategies. For instance, we found that the Office of Energy Efficiency and Renewable Energy, responsible for $16.8 billion in Recovery Act program activities, took steps to strengthen its merit review process to avoid potential conflict of interest concerns.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory and commercialization partner the Aquila Group.

Younkin, Jim↗

Advancing the Authenticatable Container Tracking System (ACTS)

The Authenticatable Container Tracking System (ACTS) is an extensible secure container tag that can be used to optimize chain-of-custody monitoring for packaged nuclear materials as they are being stored, processed, and transported. Based on the ultra–low power TI MSP430 mixed-signal microcontroller, ACTS is an active device that uses an almost-universal core platform that can be appropriately configured with expansion modules to provide the application-specific data acquisition, data logging, container sealing, and communications functions needed for 21st century material accountancy, monitoring, and tracking applications. This core architecture enables appropriately designed modules to be easily interfaced to the basic system, providing an integration path for current and new technologies. ACTS contains a built-in set of sensors and supports an expansion bus for up to six additional communications, tracking, authentication, encryption, sealing, location, or sensing modules that may enhance the monitoring and tracking of designated containers for specific applications. To date, testing has used an IEEE 802.15.4-2011 ultra-wideband–compliant wireless transceiver module that has additional capabilities for indoor positioning and proximity location. Proximity-based location (i.e., where an ACTS tag knows where it is relative to other ACTS tags) will be explored as a continuity-of-knowledge mechanism to determine unauthorized movement of containers in storage arrays of many items. Partners for this system are Oak Ridge National Laboratory, Argonne National Laboratory, Savannah River National Laboratory, Pacific Northwest National Laboratory, and commercialization partner the Aquila Group.

Younkin, James↗

Non-growing season plant nutrient uptake controls Arctic tundra vegetation composition under future climate

Abstract Plant growth and distribution in high-latitude tundra ecosystems is strongly limited by nutrient availability and is critical for quantifying centennial-scale carbon-climate interactions. However, land model representations of plant–nutrient interactions are uncertain, leading to poor comparisons with high-latitude observations. Although it has been recognized for decades in the observational community that plants continue to acquire nutrients well past when aboveground activity has ceased, most large-scale land models ignore this process. Here we address the role tundra plant nutrient acquisition during the non-growing season (NGS) has on centennial-scale vegetation growth and dynamics, with a focus on shrub expansion. We apply a well-tested mechanistic model of coupled plant, microbial, hydrological, and thermal dynamics that explicitly represents nutrient acquisition based on plant and microbial traits, thereby allowing a prognostic assessment of NGS nutrient uptake. We first show that the model accurately represents observed seasonality of NGS plant nutrient uptake in a northern Alaskan tundra site. Applying the model across the North America tundra indicates that NGS nutrient uptake is consistent with observations and ranges between ∼5% and 50% of annual uptake, with large spatial variability and dependence on plant functional type. We show that NGS plant nutrient acquisition strongly enhances modeled 21 st century tundra shrub growth and expansion rates. Our results suggest that without NGS nutrient uptake, total shrub aboveground dominance would be ∼50% lower, limited primarily by their inability to grow tall enough to maximize their inherent capacity for light competition. Evergreen shrubs would be more strongly affected because of their relatively lower capacity for nutrient remobilization and acquisition compared to deciduous shrubs. Our results highlight the importance of NGS plant and soil processes on high-latitude biogeochemistry and vegetation dynamics and motivate new observations and model structures to represent these dynamics.

54 ENVIRONMENTAL SCIENCES↗

Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography

Purpose: The purpose of this work is to propose a cost function with regularization to iteratively reconstruct attenuation, phase, and scatter images simultaneously from differential phase contrast (DPC) acquisitions, without the need of phase retrieval, and examine its properties. Furthermore this reconstruction method is applied to an acquisition pattern that is suitable for a DPC tomographic system with continuously rotating gantry (sliding window acquisition), overcoming the severe smearing in noniterative reconstruction. Methods: We derive a penalized maximum likelihood reconstruction algorithm to directly reconstruct attenuation, phase, and scatter image from the measured detector values of a DPC acquisition. The proposed penalty comprises, for each of the three images, an independent smoothing prior. Image quality of the proposed reconstruction is compared to images generated with FBP and iterative reconstruction after phase retrieval. Furthermore, the influence between the priors is analyzed. Finally, the proposed reconstruction algorithm is applied to experimental sliding window data acquired at a synchrotron and results are compared to reconstructions based on phase retrieval. Results: The results show that the proposed algorithm significantly increases image quality in comparison to reconstructions based on phase retrieval. No significant mutual influence between the proposed independent priors could be observed. Further it could be illustrated that the iterative reconstruction of a sliding window acquisition results in images with substantially reduced smearing artifacts. Conclusions: Although the proposed cost function is inherently nonconvex, it can be used to reconstruct images with less aliasing artifacts and less streak artifacts than reconstruction methods based on phase retrieval. Furthermore, the proposed method can be used to reconstruct images of sliding window acquisitions with negligible smearing artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

A 32-channel photon counting module with embedded auto/cross-correlators for real-time parallel fluorescence correlation spectroscopy

Fluorescence correlation spectroscopy (FCS) is a well-established technique to study binding interactions or the diffusion of fluorescently labeled biomolecules in vitro and in vivo. Fast FCS experiments require parallel data acquisition and analysis which can be achieved by exploiting a multi-channel Single Photon Avalanche Diode (SPAD) array and a corresponding multi-input correlator. This paper reports a 32-channel FPGA based correlator able to perform 32 auto/cross-correlations simultaneously over a lag-time ranging from 10 ns up to 150 ms. The correlator is included in a 32 × 1 SPAD array module, providing a compact and flexible instrument for high throughput FCS experiments. However, some inherent features of SPAD arrays, namely afterpulsing and optical crosstalk effects, may introduce distortions in the measurement of auto- and cross-correlation functions. We investigated these limitations to assess their impact on the module and evaluate possible workarounds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biomarker Mapping on Skin Tape Strips Using MALDI Mass Spectrometry Imaging

Keratinocyte organization and biochemistry are important in forming the skin’s protective barrier. Intrinsic and extrinsic factors can affect skin barrier function at the cellular and molecular levels. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometric imaging, a technique which combines both molecular aspects and histological details, has proven to be a valuable method in various disciplines including pharmacology, dermatology and cosmetology. It typically requires ex vivo samples, prepared following frozen tissue sectioning. This paper demonstrates the feasibility of performing MALDI analysis on tape strips collected non-invasively on skin. The aim is to obtain molecular imaging of corneocytes on tapes towards novel biological insights. Tapes were collected from two skin sites (volar forearm and cheek) of human volunteers. Ten molecules relating to skin barrier function were detected with a single mode of acquisition at high spatial resolution with a 7 T MALDI-Fourier transform ion cyclotron resonance (FTICR) instrument. The method sensitivity was adequate to create molecular maps which could be overlaid on transmission microscopy images of the same area of the tape. Analysis of the molecular distributions from tapes at the two skin sites was consistent with the known skin properties of the two sites, confirming the validity of the observations. Hierarchical clustering analysis was used to differentiate corneocyte populations based on their molecular profiles. Furthermore, morphological analysis provided a new way of considering statistical populations of corneocytes on the same tape, rather than measuring a single averaged value, providing additional useful information relating to their structure-function relationship. .

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NSLS-II: Turn-by-Turn BPM Data Analysis – A Use Case Approach

A modern ring-based light source is a complex dynamic system for which the design is guided by a realistic computer model with predictable results. State-of-the-arts beam requirements translate into tight engineering tolerances. So, quality assurance for the equipment, e.g. ring magnets, girder system, power supplies, RF system, etc. is crucial to deliver on the design goals for the beam quality. For a streamlined commissioning and an effective approach for integration of insertion devices, the latter being an activity that is typically on-going for the entire life cycle of the facility, it is equally important to be able to calibrate the beam dynamics design model against the real system and pursue e.g. “gap analysis”, linear and nonlinear optics corrections, improvements to the baseline design, etc. In particular, for high-end insertion devices. Conceptually, it can be thought of as pursuing Model-Based and Adaptive Control; instead of “flying blind”. A straightforward approach is to use a pinger, a ~30 cm long hor/ver kicker that can kick the beam to about 1 mrad in each plane [1-2] and a Turn-by-Turn BPM data acquisition system that records the betatron motion on a Turn-by-Turn basis. Examples include: ALS, SLS, DIAMOND, and SOLEIL. We first outline how to measure the Beam Impulse Response (BIR) function and related Beam Transfer Function (BTF) with a Turn-by-Turn BPM data acquisition system and a pinger. In particular, how to obtain the amplitude and phase of the spectral components in the betatron spectrum with high precision by using signal processing. We also quantify how the impact of noise affects the accuracy of the measurements.

97 MATHEMATICS AND COMPUTING↗

SU-D-207A-04: Use of Gradient Echo Plural Contrast Imaging (GEPCI) in MR-Guided Radiation Therapy: A Feasibility Study Targeting Brain Treatment

Purpose: To implement the Gradient Echo Plural Contrast Imaging(GEPCI) technique in MRI-simulation for radiation therapy and assess the feasibility of using GEPCI images with advanced inhomogeneity correction in MRI-guided radiotherapy for brain treatment. Methods: An optimized multigradient-echo GRE sequence (TR=50ms;TE1=4ms;delta-TE=4ms;flip angle=300,11 Echoes) was developed to generate both structural (T1w and T2*w) and functional MRIs (field and susceptibility maps) from a single acquisition. One healthy subject (Subject1) and one post-surgical brain cancer patient (Subject2) were scanned on a Philips Ingenia 1.5T MRI used for radiation therapy simulation. Another healthy subject (Subject3) was scanned on a 0.35T MRI-guided radiotherapy (MR-IGRT) system (ViewRay). A voxel spread function (VSF) was used to correct the B0 inhomogeneities caused by surgical cavities and edema for Subject2. GEPCI images and standard radiotherapy planning MRIs for this patient were compared focusing the delineation of radiotherapy target region. Results: GEPCI brain images were successfully derived from all three subjects with scan times of <7 minutes. The images derived for Subjects1&2 demonstrated that GEPCI can be applied and combined into radiotherapy MRI simulation. Despite low field, T1-weighted and R2* images were successfully reconstructed for Subject3 and were satisfactory for contour and target delineation. The R2* distribution of grey matter (center=12,FWHM=4.5) and white matter (center=14.6, FWHM=2) demonstrated the feasibility for tissue segmentation and quantification. The voxel spread function(VSF) corrected surgical site related inhomogeneities for Subject2. R2* and quantitative susceptibility map(QSM) images for Subject2 can be used to quantitatively assess the brain structure response to radiation over the treatment course. Conclusion: We implemented the GEPCI technique in MRI-simulation and in MR-IGRT system for radiation therapy. The images demonstrated that it is feasible to adopt this technique in radiotherapy for structural delineation. The preliminary data also enable the opportunity for quantitative assessment of radiation response of the target region and normal tissue.

60 APPLIED LIFE SCIENCES↗

Methanobactin and the Link between Copper and Bacterial Methane Oxidation

Methanobactins (mbs) are low-molecular-mass (<1,200 Da) copper-binding peptides, or chalkophores, produced by many methane-oxidizing bacteria (methanotrophs). These molecules exhibit similarities to certain iron-binding siderophores but are expressed and secreted in response to copper limitation. Structurally, mbs are characterized by a pair of heterocyclic rings with associated thioamide groups that form the copper coordination site. One of the rings is always an oxazolone and the second ring an oxazolone, an imidazolone, or a pyrazinedione moiety. The mb molecule originates from a peptide precursor that undergoes a series of posttranslational modifications, including (i) ring formation, (ii) cleavage of a leader peptide sequence, and (iii) in some cases, addition of a sulfate group. Functionally, mbs represent the extracellular component of a copper acquisition system. Consistent with this role in copper acquisition, mbs have a high affinity for copper ions. Following binding, mbs rapidly reduce Cu 2+ to Cu 1+ . In addition to binding copper, mbs will bind most transition metals and near-transition metals and protect the host methanotroph as well as other bacteria from toxic metals. Several other physiological functions have been assigned to mbs, based primarily on their redox and metal-binding properties. Here, we examine the current state of knowledge of this novel type of metal-binding peptide. We also explore its potential applications, how mbs may alter the bioavailability of multiple metals, and the many roles mbs may play in the physiology of methanotrophs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transconvolution and the virtual positron emission tomograph-A new method for cross calibration in quantitative PET/CT imaging

Purpose: Positron emission tomography (PET)/computed tomography (CT) measurements on small lesions are impaired by the partial volume effect, which is intrinsically tied to the point spread function of the actual imaging system, including the reconstruction algorithms. The variability resulting from different point spread functions hinders the assessment of quantitative measurements in clinical routine and especially degrades comparability within multicenter trials. To improve quantitative comparability there is a need for methods to match different PET/CT systems through elimination of this systemic variability. Consequently, a new method was developed and tested that transforms the image of an object as produced by one tomograph to another image of the same object as it would have been seen by a different tomograph. The proposed new method, termed Transconvolution, compensates for differing imaging properties of different tomographs and particularly aims at quantitative comparability of PET/CT in the context of multicenter trials. Methods: To solve the problem of image normalization, the theory of Transconvolution was mathematically established together with new methods to handle point spread functions of different PET/CT systems. Knowing the point spread functions of two different imaging systems allows determining a Transconvolution function to convert one image into the other. This function is calculated by convolving one point spread function with the inverse of the other point spread function which, when adhering to certain boundary conditions such as the use of linear acquisition and image reconstruction methods, is a numerically accessible operation. For reliable measurement of such point spread functions characterizing different PET/CT systems, a dedicated solid-state phantom incorporating {sup 68}Ge/{sup 68}Ga filled spheres was developed. To iteratively determine and represent such point spread functions, exponential density functions in combination with a Gaussian distribution were introduced. Furthermore, simulation of a virtual PET system provided a standard imaging system with clearly defined properties to which the real PET systems were to be matched. A Hann window served as the modulation transfer function for the virtual PET. The Hann's apodization properties suppressed high spatial frequencies above a certain critical frequency, thereby fulfilling the above-mentioned boundary conditions. The determined point spread functions were subsequently used by the novel Transconvolution algorithm to match different PET/CT systems onto the virtual PET system. Finally, the theoretically elaborated Transconvolution method was validated transforming phantom images acquired on two different PET systems to nearly identical data sets, as they would be imaged by the virtual PET system. Results: The proposed Transconvolution method matched different PET/CT-systems for an improved and reproducible determination of a normalized activity concentration. The highest difference in measured activity concentration between the two different PET systems of 18.2% was found in spheres of 2 ml volume. Transconvolution reduced this difference down to 1.6%. In addition to reestablishing comparability the new method with its parameterization of point spread functions allowed a full characterization of imaging properties of the examined tomographs. Conclusions: By matching different tomographs to a virtual standardized imaging system, Transconvolution opens a new comprehensive method for cross calibration in quantitative PET imaging. The use of a virtual PET system restores comparability between data sets from different PET systems by exerting a common, reproducible, and defined partial volume effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gaussian processes for autonomous data acquisition at large-scale synchrotron and neutron facilities

The execution and analysis of complex experiments are challenged by the vast dimensionality of the underlying parameter spaces. Although an increase in data-acquisition rates should allow broader querying of the parameter space, the complexity of experiments and the subtle dependence of the model function on input parameters remains daunting owing to the sheer number of variables. New strategies for autonomous data acquisition are being developed, with one promising direction being the use of Gaussian process regression (GPR). GPR is a quick, non-parametric and robust approximation and uncertainty quantification method that can be applied directly to autonomous data acquisition. We review GPR-driven autonomous experimentation and illustrate its functionality using real-world examples from large experimental facilities in the USA and France. We introduce the basics of a GPR-driven autonomous loop with a focus on Gaussian processes, and then shift the focus to the infrastructure that needs to be built around GPR to create a closed loop. Finally, the case studies we discuss show that Gaussian-process-based autonomous data acquisition is a widely applicable method that can facilitate the optimal use of instruments and facilities by enabling the efficient acquisition of high-value datasets.

36 MATERIALS SCIENCE↗

Measuring SNM Isotopic Distributions using FRAM

The first group of slides provides background information on the isotopic composition of plutonium. It is shown that 240 Pu is the critical isotope in neutron coincidence/multiplicity counting. Next, response function analysis to determine isotopic composition is discussed. The isotopic composition can be determined by measuring the net peak counts from each isotope and then taking the ratio of the counts for each isotope relative to the total counts for the element. Then FRAM (Fixed energy Response function Analysis with Multiple efficiencies) is explained. FRAM can control data acquisition, automatically analyze newly acquired data, analyze previously acquired data, provide information on the quality of the analysis, and facilitate analysis in unusual situations (non-standard energy calibrations, gamma rays from non-SNM isotopes, poor spectra (within limits)).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗