Search NASA⌕ Search

SEARCH · Search NASA

Results for “air”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Influence of Air‐Sea CO 2 Disequilibrium on Carbon Sequestration by the Ocean's Biological Pump

Abstract The ocean's biological carbon pump (BCP) affects the Earth's climate by sequestering CO 2 away from the atmosphere for decades to millennia. One primary control on the amount of carbon sequestered by the biological pump is air‐sea CO 2 disequilibrium, which is controlled by the rate of air‐sea CO 2 exchange and the residence time of CO 2 in surface waters. Here, we use a data‐assimilated model of the soft tissue BCP to quantify carbon sequestration inventories and time scales from remineralization in the water column to equilibration with the atmosphere. We find that air‐sea CO 2 disequilibrium enhances the global biogenic carbon inventory by ∼35% and its sequestration time by ∼70 years compared to identical calculations made assuming instantaneous air‐sea CO 2 exchange. Locally, the greatest enhancement occurs in the subpolar Southern Ocean, where air‐sea disequilibrium increases sequestration times by up to 600 years and the biogenic dissolved inorganic carbon inventory by >100% in the upper ocean. Contrastingly, in deep‐water formation regions of the North Atlantic and Antarctic margins, where biological production creates undersaturated surface waters which are subducted before fully equilibrating with the atmosphere, air‐sea CO 2 disequilibrium decreases the depth‐integrated sequestration inventory by up to ∼150%. The global enhancement of carbon sequestration by air‐sea disequilibrium is particularly important for carbon respired in deep waters that upwell in the Southern Ocean. These results highlight the importance of accounting for air‐sea CO 2 disequilibrium when evaluating carbon sequestration by the biological pump and for assessing the efficacy of ocean‐based CO 2 removal methods.

Environmental Sciences & Ecology↗

Citywide indoor air sampling mirrors wastewater and clinical for environmental surveillance of respiratory viruses

Wastewater surveillance of respiratory pathogens can provide timely estimates of viral activity and disease trends in a population. Indoor air surveillance could be used similarly with some advantages but remains largely unvalidated at the community -scale. Here, an indoor air surveillance program was employed as part of public health environmental surveillance in Chicago, Illinois, USA. Ten air samplers were placed in healthcare and congregate living settings across the city. Weekly air samples were evaluated for influenza A, influenza B, respiratory syncytial virus, and SARS -CoV-2 over two respiratory virus seasons (2023 -2025). Citywide, aggregated air sample positivity and viral load were closely correlated with local clinical case and wastewater surveillance data across all respiratory viruses. Virus trends in air data often preceded clinical and wastewater, although this varied across pathogens and respiratory virus seasons. Further, whole -genome sequencing of SARS -CoV-2 showed close correlation of variant proportions across all datasets. At the building -scale, air samples obtained from a single sampling device provided efficient respiratory virus surveillance, with respiratory pathogen levels mirroring citywide clinical surveillance data. These data demonstrate that air surveillance can provide respiratory virus case and variant trend data at a building or community -scale, serving as an alternative or complementary tool for public health environmental surveillance.

Wilton, Rosemarie↗

ORGANIC RANKINE CYCLE TURBINE AND HEAT EXCHANGER SIZING FOR LIQUID AIR COMBINED CYCLE

Cryogenic energy storage offers several opportunities to design turbomachinery and other equipment for novel cycles. This paper presents the design and analysis of turbomachinery and heat exchangers for an Organic Rankine Cycle (ORC) subsystem for a hybrid energy storage concept. The Liquid Air Combined Cycle is an energy storage system that stores air at cryogenic conditions at times with high variable renewable energy to be dispatched along with a gas turbine to recover the exhaust heat. In order to re-vaporize the air, the liquid air is coupled with an ORC as an additional bottoming cycle. The ORC turbine is expected to expand the fluid with a pressure ratio of nearly 30 and a flow rate of approximately 45 kg/s. Sizing calculations for both a radial and axial turbine solution were performed over a range of speeds and stages to determine the optimal design point. The results show that either an axial (8- or 9-stage) or radial (four stages at two shaft speeds) turbine are capable of handling the pressure ratios. Further trades of the two configurations would be required to determine the best option. The ORC system also incorporates five heat exchangers to distribute heat, vaporize the liquid air, or recover exhaust heat from the gas turbine. Three heat exchangers were analyzed to understand the size of heat exchangers and pressure drop for the overall system. Different types of heat exchangers were explored for the different purposes, including plate-fin heat exchangers, gasketed plate heat exchangers and shell-in-tube heat exchangers. It was determined that the ORC recuperator, liquid-air vaporizer, and vaporized air pre-heater would be counter-flow heat exchangers using a gasketed plate design. Keywords: Energy Storage, Liquid Air Energy Storage, Organic Rankine Cycle

Pryor, Owen↗

Extending the Air and Moisture Leakage Calculator to add Residential Buildings and Additional Commercial Buildings

The DOE Windows and Building Envelope Research and Development Roadmap for Emerging Technologies shows that in 2010, infiltration was responsible for 4 quads of space conditioning primary energy use in the residential and commercial sectors. The relative contribution of air leakage in building heating and cooling load is increasing with improvement in the thermal resistance of building envelopes. Advanced air barrier technologies and construction practices have been developed to reduce air leakage in buildings. However, limited information on the impact of air barrier technologies on energy consumption and the durability of buildings has hindered their adoption. In the past Oak Ridge National Laboratory (ORNL), the National Institute of Standards and Technology (NIST), Air Barrier Association of America (ABBA), and U.S.-China Clean Energy Research Center for Building Energy Efficiency (CERC-BEE) collaborated to develop an online calculator that estimates the potential energy and cost savings in major U.S., Canadian and Chinese cities from improvement in air tightness in commercial buildings. In 2018–2019, the calculator was expanded to add moisture transfer calculations given that air leakage through the building envelope can have a significant impact on moisture transfer and associated impacts. In this study, the calculator is expanded further by adding data for two additional commercial buildings (strip mall and primary school) and a residential building. The team investigated the impact of airtightness on energy consumption and moisture transfer of the added buildings. The study includes the analysis of air tightness in 52 major cities in the U.S. and 5 cities in Canada.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Passenger cabin air distribution system and method of using

A passenger cabin air distribution system includes a ventilation system and an ejector-diffuser. The ventilation system is operable to provide a conditioned air. The ejector-diffuser is positioned to receive a flow of the conditioned air from the ventilation system. The ejector-diffuser includes an induction unit and a diffuser section. The induction unit includes a secondary inlet in communication with a cabin air from a passenger cabin and is configured to mix the flow of the conditioned air with an induced flow of the cabin air into a mixed air. The diffuser section includes a discharge to eject the mixed air to the passenger cabin. The diffuser section is shaped to provide for efficient mixing with low backpressure in order to maintain the low motive pressure in the nozzle.

42 ENGINEERING↗

Personal Interventions for Reducing Exposure and Risk for Outdoor Air Pollution: An Official American Thoracic Society Workshop Report

Poor air quality affects the health and wellbeing of large populations around the globe. Although source controls are the most effective approaches for improving air quality and reducing health risks, individuals can also take actions to reduce their personal exposure by staying indoors, reducing physical activity, altering modes of transportation, filtering indoor air, and using respirators and other types of face masks. A synthesis of available evidence on the efficacy, effectiveness, and potential adverse effects or unintended consequences of personal interventions for air pollution is needed by clinicians to assist patients and the public in making informed decisions about use of these interventions. To address this need, the American Thoracic Society convened a workshop in May of 2018 to bring together a multidisciplinary group of international experts to review the current state of knowledge about personal interventions for air pollution and important considerations when helping patients and the general public to make decisions about how best to protect themselves. From these discussions, recommendations were made regarding when, where, how, and for whom to consider personal interventions. In addition to the efficacy and safety of the various interventions, the committee considered evidence regarding the identification of patients at greatest risk, the reliability of air quality indices, the communication challenges, and the ethical and equity considerations that arise when discussing personal interventions to reduce exposure and risk from outdoor air pollution.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

An Overview of Policies Influencing Air Pollution from the Electricity Sector in Central Asia

The electricity sector is a substantial source of air pollution and associated health problems in Central Asia and elsewhere. Fossil-fueled power plants emit a wide variety of harmful pollutants and their chemical precursors. The pollutants with the greatest health impacts are particulate matter and ozone. Once released into the atmosphere, there is no practical way to remove air pollutants, which means that policies designed to improve air quality have to limit the pollutants before release. However, tackling such pollution is challenging, particularly in developing economies, due to the need to provide electricity as a basic necessity for citizens and as an engine of economic growth. This report provides examples of policies impacting air pollution from the electricity sector in the Central Asian countries of Kazakhstan, Kyrgyzstan, Tajikistan, Turkmenistan, and Uzbekistan. It is a partner publication to an earlier report that addressed policies in South Asia. As with the South Asia report, information on policies in some countries was difficult to locate; therefore, this is not a comprehensive study, but rather an overview or "scan" of the sector that includes examples of: (1) policies that directly regulate air quality by limiting emissions from specific point sources (by restricting operating hours, for instance); and (2) indirect policies that incentivize or disincentivize polluting activities, such as policies to encourage fuel switching to or from cleaner renewable resources. Note that this report was prepared before the Russia-Ukraine conflict and therefore doesn't address consequences of that war for Central Asia. The report finds: (1) That Central Asian countries typically have relatively few policy instruments available for regulating national air emissions; (2) That many countries, especially those that have a mismatch between seasonal demand and resource availability, could improve energy security and reduce air pollution through increased cross-border electricity trade; (3) That some countries have seemingly contradictory policies (promoting both coal and renewables, for instance). This report is also available in Russian: https://www.nrel.gov/docs/fy23osti/85192.pdf.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Iron-Decorated Carbon Aerogel for Rechargeable Flow and Flexible Zn–Air Batteries

Mechanically stable and foldable air cathodes with exceptional oxygen reduction reaction (ORR) and oxygen evolution reaction (OER) activities are key components of wearable metal-air batteries. Herein, a directional freeze-casting and annealing approach is reported for the construction of a 3D honeycomb nanostructured, N,P-doped carbon aerogel incorporating in situ grown FeP/Fe 2 O 3 nanoparticles as the cathode in a flexible Zn-air battery (ZAB). The aqueous rechargeable Zn-air batteries assembled with this carbon aerogel exhibit a remarkable specific capacity of 648 mAh g -1 at a current density of 20 mA cm -2 with a good long-term durability, outperforming those assembled with commercial Pt/C+RuO 2 catalyst. Furthermore, such a foldable carbon aerogel with directional channels can serve as a freestanding air cathode for flexible solid-state Zn-air batteries without the use of carbon paper/cloth and additives, giving a specific capacity of 676 mAh g -1 and an energy density of 517 Wh kg -1 at 5 mA cm -2 together with good cycling stability. This work offers a new strategy to design and synthesize highly effective bifunctional air cathodes to be applied in electrochemical energy devices.

25 ENERGY STORAGE↗

Highly Active and Durable Air Electrodes for Reversible Protonic Ceramic Electrochemical Cells Enabled by an Efficient Bifunctional Catalyst

The commercialization of reversible protonic ceramic electrochemical cells is hindered by the lack of highly active and durable air electrodes exposed to high concentration of steam under operating conditions. We report findings that dramatically enhance the electrocatalytic activity and stability of a conventional (La 0.6 Sr 0.4 ) 0.95 Co 0.2 Fe 0.8 O 3-δ (LSCF) air electrode by a multiphase catalyst coating composed of a conformal Pr 1-x Ba x CoO 3-δ thin film and exsolved BaCoO 3-δ nanoparticles, are reported. At 600 °C, the catalyst coating decreases the polarization resistance of the LSCF air electrode by a factor of 25 (from 1.09 to 0.043 Ω cm 2 ) in air and the degradation rate by two orders of magnitude (from 1.0 × 10 -2 to 1.8 × 10 -4 Ω cm2 h -1 in humidified air with 30 vol% H2O). Further, a single cell with the catalyst-coated LSCF air electrode at 600 °C demonstrates a high peak power density of 1.04 W cm -2 in the fuel cell mode and a high current density of 1.82 A cm -2 at 1.3 V in the electrolysis mode. The significantly enhanced performance of the LSCF air electrode is attributed mainly to the high rate of surface oxygen exchange, fast surface proton diffusion, and the rapid H 2 O and O 2 dissociation on the catalysts.

36 MATERIALS SCIENCE↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance evaluation of an air conditioning system based on quasi isothermal dehumidifcation

This work presents a first study of novel air conditioning system based on quasi isothermal dehumidification combined with dew-point evaporative cooling through the Maisotsenko cycle (M-Cycle). The dehumidification process is realized in desiccant coated heat exchanger with heat rejection system. The key idea behind the solution is to maximize the cooling effectiveness by creating favourable conditions for dehumidification and evaporative cooling process. This is achieved by rejecting the heat of sorption in the desiccant system and providing cold and dry air for M-Cycle air cooler, which allows the system to be powered by using low-grade heat energy at 50 °C. The analysis is performed on the basis of experimentally validated numerical models of each component combined in a unified model of the system. The goal of the study is to determine the performance of the solution under different operational conditions. In addition two types of M-Cycle air coolers (i.e. cross-flow and regenerative unit) are compared to establish which unit is more suitable as the source of cooling energy for the system. It was established that proposed system is able to provide comfortable room parameters (supply air temperature equal 17 °C and humidity ratio equal 0.010 kg/kg-da) for outdoor air temperatures ranging from 28 to 36 °C and outdoor air humidity ranging from 0.010 to 0.018 kg/kg-da. This means that the proposed solution is able to provide comfortable conditions in temperate and humid climates. Results also indicate that the system consisting of the regenerative M-Cycle HMX allows better cooling load management, offers higher thermal Coefficient of Performance (COP th ) and uses less water compared to the system with the cross-flow HMX. However, the system with cross-flow heat and mass exchanger (HMX) has a relatively greater electrical Coefficient of Performance (COP el ) in most cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Analysis and Limiting Parameters of Cross-flow Membrane-based Liquid-desiccant Air Dehumidifiers

We report that to dehumidify a humid air stream, existing air conditioning (AC) systems substantially overcool the outdoor humid air below its dew point, thereby significantly reducing energy efficiency. Directly capturing humidity, membrane-based liquid-desiccant dehumidification systems separate sensible and latent cooling (SSLC) loads and thus offer a promising pathway for a high-performance AC solution. Design of an energy-efficient SSLC-AC system, however, rests largely on detailed understating of the dehumidification process. While some studies have identified the dehumidification process mainly depends on membrane characteristics, other studies have argued that the process is limited by desiccant liquid or alternatively air thermo-hydraulic physics for typical humid climate conditions. The present study examines performance and physics of the membrane-based liquid-desiccant dehumidification process over a wide range of climate conditions through a novel 3D, two-phase, multi-species CFD model. Decoupling the thermodynamic and hydraulic effects, the study reveals that the dehumidification rate is a linear function of the water vapor pressure potential ($J=α ΔP$) summarizing the system's thermodynamic state. The slope of the curve (i.e., α) depends on hydraulic transport characteristics of the membrane pores, air stream, and desiccant solution. More importantly, it was found that the air dehumidification process is mainly limited by the air-side transport physics for thin liquid-desiccant films and commonly used porous superhydrophobic membranes. Additionally, results show that, depending on ambient/desiccant conditions and physical dehumidifier characteristics, energy effectiveness and dehumidification rate vary from 13 to 34% and from 0.13 to 1.4 g m -2 s -1 , respectively. Therefore, the present study allows to efficiently design future SSLC-based AC systems exhibiting high performance energy metrics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A novel transient infrared imaging method for non-intrusive, low-cost, fast, and accurate air leakage detection in building envelopes

Air leakage through the building envelope in the U.S. accounts for about four quads of energy annually, costing approximately $40 billion per year. However, a high-fidelity and non-intrusive method to detect air leakage has not been demonstrated to date. Here, in this paper, we propose a novel non-intrusive and low-cost method called Transient Infrared (IR) Imaging (TIRI) that can rapidly and accurately identify air leakage locations and relative rates on building envelopes. When the interior and exterior temperatures are different, and a small internal pressure pulse is created by HVAC, the temperature at locations with air leakages will change rapidly, while the areas without a leakage do not change. Based on a heat transfer model, we have derived the temperature change as a function of time after the HVAC is turned on. By tracking the temperature change, which depends on leakage rate and size, we have obtained the air leakage map in the case studies. Using an exterior door as an example, we took transient IR images in different seasons and different times of the day, and successfully obtained the leakage map in all the scenarios. Successfully obtained the air leakage map even when the indoor-outdoor air temperature difference is as small as 2 °C. We have also realized a detection speed of 10s and demonstrated that this method also worked for windows, which have mirror-like IR reflections. Our TIRI method will accelerate the improvement of airtightness in buildings, save building energy, and help reduce greenhouse gas emissions.

42 ENGINEERING↗

Humidity’s impact on greenhouse gas emissions from air conditioning

We report that the increasing need to cool the air in our built environment is both a cause and an effect of climate change. Air conditioning accounts for a large portion of global greenhouse gas emissions today, which we estimate at 3.9%; however, the role that humidity plays in these emissions is often overlooked. Here, we show that the emissions associated with reducing air humidity (i.e., removing water vapor from air) are larger than emissions associated with reducing air temperature (i.e., cooling air). We calculate these emissions for today and 2050 and show how dramatically humidity-related emissions will increase with rising cooling demand around the world. We also calculate the minimum separation energy for removing water vapor from air and find that this is at least an order of magnitude less than the processes used today.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LA100 Equity Strategies. Chapter 11: Truck Electrification for Improved Air Quality and Health

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This report focuses on truck electrification as a means to improve air quality and health in traffic and air quality disadvantaged communities. It also identifies potential strategies to more equitably distribute air quality benefits from electrification of trucks, defined here as heavy-duty vehicles over 8,500 pounds (lbs) gross vehicle weight. Specifically, NREL analyzed 1) baseline air pollutant emissions, 2) emissions reductions associated with incremental increases in electrification of three types of heavy-duty trucks in 2035, and 3) resultant changes to air pollutant concentrations for selected census tracts along major roadways in disadvantaged and non-disadvantaged communities for comparison. In addition, NREL analyzed the impact of estimated pollutant concentrations on several health effects and the distribution of those health effects by disadvantaged community status. NREL's analysis is complemented by a University of California Los Angeles (UCLA) analysis of air quality benefits from transportation electrification, which included light-duty vehicles (Chapter 15) and evaluated regional air-quality changes across Los Angeles. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mass transfer coefficients, kL, and air-CO2 ingassing rates in 3.4 m2 and 1-acre raceway ponds.

The US DOE 2016 Billion Ton Update (Langholtz 2016) projected that CO2 in flue-gas from power plants or similar sources would limit U.S. algal biofuel potential to under 5 billion gallons gasoline equivalent (gge) per year, due to lack of sufficient land, water and other requirements near such flue gas sources. 2nd generation carbon capture technologies are proposed to overcome this constraint (Davis 2017), and could expand this resource potential nearly 10-fold, assuming CO2 costs near the future, 2025 DOE NETL, goal of $40/metric ton CO2. An alternative pathway is the direct uptake of air CO2 into the algal ponds through an increase in the air-CO2 transfer rate resulting from the reaction of CO2 with hydroxide ions. However, such a ‘chemical enhancement’ in mass transfer depends on a high pH in the culture, and, by extension, the ability of microalgae to maintain high rates of carbon assimilation under such conditions. Abiotic experiments characterized the air-CO2 mass-transfer rate in 1-acre and 3.4 m2 raceway ponds as a function of pH, with rates approaching 10 g C/m2-day at pH 12 in the brackish water tested, equivalent to a biomass productivity potential of near 20 g AFDW/m2-day (@ 0.47 g C/g AFDW). The mass transfer rate was found to be nearly independent of the mass-transfer coefficient, indicating that at turbulence levels achievable in typical raceway ponds, the system is reaction rate, rather than diffusion limited. In biotic trials with an unknown green microalga, biomass productivity in ponds receiving CO2 from only direct surface air-CO2 exchange averaged 5 +/- 0.5 g AFDW/m2-day in August - September central California conditions, about half-that of experimental controls fertilized with supplemental CO2. pH in the air-only treatment reached a maximum of 10.5, supporting a model predicted air-CO2 ingassing rate between 2-3 g C/m2-day, consistent with the observed biomass carbon assimilation rate. Results suggest that unique alkaliphilic strains are required if reliant on direct in-pond air-CO2 transfer for algal inorganic carbon supply, and that reaching an economically viable biomass productivity will require strains that thrive at pH 11 and above.

09 BIOMASS FUELS↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗