Search NASA⌕ Search

SEARCH · Search NASA

Results for “alternative”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Exploring Novel Configuration Designs Alternatives for Lazy Wave Submarine Power Cables

Floating offshore wind turbines require a complex integrated design to balance the platform response and station-keeping requirements in a highly dynamic environment. Dynamic subsea power cables are one of the critical components that have to be considered in detail to ensure both extreme, as well as repeated operational conditions do not exceed the cable design limits. This paper presents the design feasibility limits of a 66kV dynamic cable for a lazy wave configuration. The work explores an innovative staggered cable configuration that has the potential to provide additional compliance in shallow water conditions. Both configurations are evaluated using the motions of a representative floating wind platform under development for deployment in relatively shallow water depth of 150m. The assessment was conducted using the hydrodynamic software Orcaflex, incorporating a range of design inputs and design variations. Key parameters analysed include cable curvature and effective tension and bending stress. The alternative cable configuration provides a more gradual crossing of the water column, which would allow to support increased platform excursions in shallow water depths. The design uses a combined buoyancy and bend protection element, offering designers additional options for challenging operational conditions. The paper will be of interest to designers and developers of floating wind projects, providing a comparative assessment between the conventional lazy wave configuration and an innovative alternative that enables larger cable and mooring excursion envelopes in challenging conditions.

16 TIDAL AND WAVE POWER↗

A Bilevel Approach for Identifying the Worst Contingencies for Nonconvex Alternating Current Power Systems

We address the bilevel optimization problem of identifying the most critical attacks to an alternating current (AC) power flow network. The upper-level binary maximization problem consists of choosing an attack that is treated as a parameter in the lower-level defender minimization problem. Instances of the lower-level global minimization problem by themselves are NP-hard due to the nonconvex AC power flow constraints, and bilevel solution approaches commonly apply a convex relaxation or approximation to allow for tractable bilevel reformulations at the cost of underestimating some power system vulnerabilities. Our main contribution is to provide an alternative branch-and-bound algorithm whose upper bounding mechanism (in a maximization context) is based on a reformulation that avoids relaxation of the AC power flow constraints in the lower-level defender problem. Lower bounding is provided with semidefinite programming (SDP) relaxed solutions to the lower-level problem. We establish finite termination with guarantees of either a globally optimal solution to the original bilevel problem, or a globally optimal solution to the SDP-relaxed bilevel problem which is included in a vetted list of upper-level attack solutions, at least one of which is a globally optimal solution to the bilevel problem. We demonstrate through computational experiments applied to IEEE case instances both the relevance of our contribution, and the effectiveness of our contributed algorithm for identifying power system vulnerabilities without resorting to convex relaxations of the lower-level problem. We conclude with a discussion of future extensions and improvements.

97 MATHEMATICS AND COMPUTING↗

Two-Level Sketching Alternating Anderson Acceleration for Complex Physics Applications

We present a novel two-level sketching extension of the Alternating Anderson–Picard (AAP) method for accelerating fixed-point iterations in challenging single- and multiphysics simulations governed by discretized PDEs. Our approach combines a static, physics-based projection that reduces the least-squares (LS) problem to the most informative field (e.g., via Schur-complement insight) with a dynamic, algebraic sketching stage driven by a backward stability analysis under Lipschitz continuity. We introduce inexpensive estimators for stability thresholds and cache-aware randomized selection strategies to balance computational cost against memory access overhead. The resulting algorithm solves reduced LS systems in place, minimizes memory footprints, and seamlessly alternates between low-cost Picard updates and Anderson mixing. Implemented in Julia, our two-level sketching AAP achieves up to 50% time-to-solution reductions compared to standard Anderson acceleration—without degrading convergence rates—on benchmark problems including Stokes, 𝑝-Laplacian, bidomain, and Navier–Stokes formulations at varying problem sizes. These results demonstrate the method’s robustness, scalability, and potential for integration into high-performance scientific computing frameworks. Our implementation is available open source in the AAP.jl library.

Barnafi, Nicolas [University of Chile, Santiago]↗

HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) v.6.1

SAND2025-11565O HyRAM+ (Hydrogen Plus Other Alternative Fuels Risk Assessment Models) is a tool for conducting quantitative risk assessment (QRA) in transportation systems. HyRAM+ contains validated, simplified release behavior models, engineering models, and generic data relevant to hydrogen installations. HyRAM+’s platform integrates models and data to conduct QRA on user-defined hydrogen or other alternative fuel systems. The software will enable the international safety research community to add validated models to the HyRAM+ platform for use in QRAs. HyRAM (hydrogen-only) versions 1.0 to 3.1 were developed by Sandia for the Department of Energy (DOE) Hydrogen and Fuel Cell Technologies Office. The following agencies contributed to the development of HyRAM+ version 4.0 regarding the addition of methane (natural gas) and propane models: the DOE Vehicle Technologies Office and the Department of Transportation Pipeline and Hazardous Material Safety Administration. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Groth, Katrina [Sandia National Lab. (SNL-NM), Alb↗

Alternatives to MARVEL Power Conversion -- Comparison of Stirling Engine Thermal Efficiency and Design to Other Power Conversion Cycles

PRESENTATION for CONFERENCE PAPER: The Microreactor Applications, Research, Validation, and Evaluation (MARVEL) Reactor is a small liquid-metal thermal reactor that will be built at the Idaho National Laboratory to demonstrate design and operating processes for microreactors, microgrid integration, and process heat applications. Power conversion in the MARVEL design is provided by Stirling engines, which have disadvantages in nuclear environments. Compared to Stirling engine performance, some alternative power cycles can increase power production when coupled to a liquid-metal thermal reactor. In this paper, the thermal efficiency of MARVEL’s power production with Stirling engines is compared to the thermal efficiency of power production with MARVEL and alternative power cycles. Those cycles include a superheated Rankine cycle, open and closed Brayton cycles, and a supercritical carbon dioxide cycle. All cycles (except the Stirling engines) were modeled with an intermediate helium loop to meet MARVEL’s principal design criteria. All models are simple designs with conservative assumptions for consistent comparison. Detailed optimization will depend largely on reactor location and application, and the relative merit of each cycle is discussed for different environmental conditions. The study informs significant early decisions on power cycle design and economics for deployment of advanced microreactors as they move from theory and concept to execution.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FIU Project1: Chemical Process Alternatives for Radioactive Waste [Slides]

"The U.S. DOE Hanford Site has the largest number of high-level waste (HLW) storage tanks and the largest volume of HLW in the United States. The safe storage, retrieval, treatment, and disposal of approximately 53 million gallons of highly toxic, high-level radioactive waste stored in Hanford’s 177 underground tanks are a national priority. Retrieval and treatment of waste from these tanks pose a considerable challenge. Florida International University has been conducting research on several promising alternative processes and technologies that can be applied to address several technology gaps in the current waste retrieval and conditioning plans. Specifically, FIU has been involved in: the evaluation of non-metallic materials in the waste transfer system, evaluation of alternative HLW instrumentation for in-tank applications and the development of technologies to assist in the inspection of tank bottoms at Hanford."

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Where Have All of the Electrons Gone? Understanding the Role of Alternative Electron Flow and O 2 Reduction in Balancing Cellular Redox (Final Technical Report)

An informed understanding of the fundamentals of light-driven electron transfer reactions in photoautotrophic organisms is necessary to enable improved photosynthetic efficiencies for the production of renewable fuels and novel biomaterials. To obtain high photosynthetic yields, light energy must be efficiently coupled to the fixation of CO 2 . Sub-optimal environmental conditions and metabolic routing (caused by blocks in biosynthetic routes) can severely impact the conversion of light energy to biomass and lead to reactive oxygen production, which in turn can cause cellular damage and productivity losses. Hence, plants, algae, and photosynthetic bacteria have evolved a network of alternative outlets to sustain the flow of photosynthetically derived-electrons. Our research was focused on the nature and integration of these outlets. The data obtained in this project will inform efforts to rationally engineer crop plants and algae to improve photosynthetic yields by enhancing electron transfer reactions to CO 2 reduction and targeted biomass accumulation. A major project research thrust was focused on identifying and quantifying the flow of photosynthetic reductant through electron transfer circuits that result in the light-dependent reduction of O 2 . New energy management strategies were identified that are used when normal carbon assimilation pathways are compromised due to nutrient deprivation, and/or by a reduction in starch synthesis/carbon storage, all conditions resulting in highly reduced intracellular redox pools. The green alga Chlamydomonas reinhardtii, and likely many other algae, have multiple O 2 -reducing pathways that play critical roles in maintaining cellular metabolic balance and scavenging electrons that could potentially cause cellular damage, which in some instances leads to reduced photosynthetic yields but increased fitness. We explored the activities of three essential outlets associated with Chlamydomonas reinhardtii photosynthetic electron transport: (1) reduction of O 2 to H 2 O through Flavodiiron proteins (FLVs) and (2) Plastid Terminal Oxidases (PTOX), and (3) the synthesis of starch. Real-time measurements of O 2 exchange demonstrated that FLVs immediately engage during dark to light transitions, allowing electron transport when the CBBC is not fully activated. Under these conditions, we quantified, for the first time, maximal FLV activity and its overall capacity to direct photosynthetic electrons towards O 2 reduction. However, when starch synthesis is compromised, a greater proportion of electrons is directed toward O 2 reduction through the FLVs, while PTOX, which is sensitive to the PQ pool redox state, is activated. This suggests, that starch synthesis has an important role in priming/regulating CBBC and electron transport. We also identified a biological ‘switch’ in the green alga Chlamydomonas reinhardtii that reversibly restricts photosynthetic electron transport (PET) at the cytochrome b 6 f complex when reductant and ATP generated by PET are in excess of the capacity of carbon metabolism to utilize these products; we specifically show a restriction at this switch when sta6 mutant cells, which cannot synthesize starch, are limited for nitrogen (growth inhibition) and subjected to a dark to light transition. This restriction causes diminished electron flow to PSI, which prevents PSI photodamage, and the plastid alternative oxidase (PTOX) becomes fully activated, serving as an electron valve that dissipates excitation energy absorbed by PSII, thereby lessening PSII photoinhibition. Furthermore, illumination of the cells following the dark acclimation gradually diminishes the restriction at the switch. Future engineering of these switches may allow more effective electron transfer to lipid (biofuel) pathways and diminish the number of electrons “wasted” in the reduction of O 2 to water. Lastly, we explored metabolic routing of electrons during algal fermentation and discovered multiple novel pathways that are activated when the preferred anoxic routes are blocked. These provide valuable products (e.g. lactate, glycerol) that can be used in broad portfolio of biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Cost Analysis Framework for Comparing AC and DC Design Alternatives for Building Electrical Distribution Systems

In recent years, in response to the changing nature of building load, direct current (DC) distribution systems for buildings have been proposed as alternatives to traditional alternating current (AC) systems. DC distribution offers a closer match to the types of loads and generation sources found in modern buildings, the majority of which use DC electricity internally either natively or as a power conditioning stage. The proposed benefits of DC distribution compared to AC distribution within buildings include higher efficiency, lower installation cost, lower operating cost, higher reliability, improved communication and control, and simplicity. Most recent DC distribution research has focused on quantifying the efficiency advantage of DC distribution over AC distribution. However, energy savings alone do not guarantee cost savings; a more complete cost accounting is required to establish financial benefit. This report provides a framework for cost analysis and comparison of building electrical distribution systems, including common variants for both AC and DC distribution systems. The framework includes all major cost categories, including up-front costs (capital, installation labor, soft costs) and long-term costs (energy, operations and maintenance).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies of Alternative Ventilation Configurations to Mitigate Airborne Exposure Risks in Office Spaces

The objective of this study was to evaluate the impact of alternative ventilation configurations on airflow patterns and potential exposure risks in office spaces. Two existing conference rooms at Sandia NM were modeled using Computational Fluid Dynamics (CFD) simulations to characterize airflow patterns and potential airborne exposure risks in well-mixed and once-through (through-flow) ventilation conditions. Multiple scenarios were studied to evaluate the impact of occupancy, Plexiglass barriers, and a modified-return airflow configuration. Experimental and visualization tests were also conducted to validate the well-mixed and through-flow models and findings. The simulations demonstrated that the modified-return airflow configuration that promoted through-flow conditions reduced pathogen concentrations within the space compared to the well-mixed airflow configuration; occupancy reduction only reduced the number of exposed individuals, and Plexiglass barriers had almost no effect. The experimentally measured air speeds at nine anemometer locations generally matched the simulated airflow velocities, and a fog-purge visualization test was also consistent with simulated results of plume movement and dissipation. The visualization tests demonstrated improvements in air change rate with the modified return, which promoted through-flow conditions, versus the original well-mixed ventilation configuration. The results of this study demonstrate that minor modifications to a space that promote through-flow conditions can improve air quality and reduce pathogen concentrations. Additional airflow modeling and testing of alternative occupied space configurations are recommended to further inform room designs that mitigate airborne exposure risks for occupants.

42 ENGINEERING↗

The Schwarz Alternating Method for the Seamless Coupling of Nonlinear Reduced Order Models and Full Order Models

Projection-based model order reduction allows for the parsimonious representation of full order models (FOMs), typically obtained through the discretization of a set of partial differential equations (PDEs) using conventional techniques (e.g., finite element, finite volume, finite difference methods) where the discretization may contain a very large number of degrees of freedom. As a result of this more compact representation, the resulting projection-based reduced order models (ROMs) can achieve considerable computational speedups, which are especially useful in real-time or multi-query analyses. One known deficiency of projection-based ROMs is that they can suffer from a lack of robustness, stability and accuracy, especially in the predictive regime, which ultimately limits their useful application. Another research gap that has prevented the widespread adoption of ROMs within the modeling and simulation community is the lack of theoretical and algorithmic foundations necessary for the “plug-and-play” integration of these models into existing multi-scale and multi-physics frameworks. This paper describes a new methodology that has the potential to address both of the aforementioned deficiencies by coupling projection-based ROMs with each other as well as with conventional FOMs by means of the Schwarz alternating method [41]. Leveraging recent work that adapted the Schwarz alternating method to enable consistent and concurrent multiscale coupling of finite element FOMs in solid mechanics [35, 36], we present a new extension of the Schwarz framework that enables FOM-ROM and ROM-ROM coupling, following a domain decomposition of the physical geometry on which a PDE is posed. In order to maintain efficiency and achieve computation speed-ups, we employ hyper-reduction via the Energy-Conserving Sampling and Weighting (ECSW) approach [13]. We evaluate the proposed coupling approach in the reproductive as well as in the predictive regime on a canonical test case that involves the dynamic propagation of a traveling wave in a nonlinear hyper-elastic material.

97 MATHEMATICS AND COMPUTING↗

Alternative Approaches to Traditional Net Energy Metering

Most jurisdictions in the United States originally implemented net energy metering (NEM) tariffs to support the deployment and interconnection of distributed generation (DG) resources (e.g., rooftop solar photovoltaic systems). Since then, NEM has proven effective in promoting adoption of DG resources. Recently, due to concerns about sufficient recovery of utilities’ revenue requirements and cost-shifting, there is increasing interest in—or statutory requirements to pursue—alternative compensation approaches, especially in U.S. states and territories with robust growth in distributed solar. Recent increases in other forms of distributed energy resources (DERs) that can potentially send power to the distribution grid (e.g., distributed battery energy storage system (BESS)) are further driving compensation reforms. This brief provides an overview of design elements associated with alternative approaches to traditional NEM, summarizes common arguments for and against them, and identifies implementation issues that utilities may need to address. Although this brief may be most useful in jurisdictions that are interested in or required to move beyond NEM, it is also applicable to those jurisdictions that have already done so—and are looking to further implement reforms to their existing compensation mechanisms. In the broadest sense, there are three primary tariff-related components when interconnecting a DER onto the local utility’s distribution system (adapted from Zinaman et al., 2017): 1. Metering and Billing Arrangements: How utilities measure and bill electricity consumption and production. 2. DER Export Tariff Design: The structure under which utilities compensate customers for electricity they export to the grid. 3. Consumption Tariff Design: The structure under which customers pay for electricity they consume from the grid. When implementing changes to any of these primary tariff-related components, there are likely implications for a utility’s metering system, billing system, and other technology systems. Where applicable, this brief explicitly identifies such implementation challenges.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator: Third Quarter 2022

Electric vehicle (EV) charging infrastructure continues to rapidly change and grow. Using data from the U.S. Department of Energy's (DOE) Alternative Fueling Station Locator, this report provides a snapshot of the state of EV charging infrastructure in the United States in the third calendar quarter of 2022 (Q3 2022) by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with two different 2030 infrastructure requirement scenarios. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape of EV charging infrastructure. This is the eleventh report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory (NREL) publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

33 ADVANCED PROPULSION SYSTEMS↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator (Fourth Quarter 2022)

Electric vehicle (EV) charging infrastructure continues to rapidly change and grow. Using data from the U.S. Department of Energy's (DOE) Alternative Fueling Station Locator, this report provides a snapshot of the state of EV charging infrastructure in the United States in the fourth calendar quarter of 2022 (Q4 2022) by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with two different 2030 infrastructure requirement scenarios. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape of EV charging infrastructure. This is the twelfth report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory (NREL) publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

33 ADVANCED PROPULSION SYSTEMS↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator (First Quarter 2023)

Electric vehicle (EV) charging infrastructure continues to rapidly change and grow. Using data from the U.S. Department of Energy's Alternative Fueling Station Locator, this report provides a snapshot of the state of EV charging infrastructure in the United States in the first calendar quarter of 2023 by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with a 2030 infrastructure requirement scenario. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape of EV charging infrastructure. This is the thirteenth report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator: Second Quarter 2023

Electric vehicle (EV) charging infrastructure continues to rapidly change and grow. Using data from the U.S. Department of Energy's Alternative Fueling Station Locator, this report provides a snapshot of the state of EV charging infrastructure in the United States in the second calendar quarter of 2023 by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared with a 2030 infrastructure requirement scenario. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape of EV charging infrastructure. This is the fourteenth report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and National Renewable Energy Laboratory publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

33 ADVANCED PROPULSION SYSTEMS↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Electric Vehicle Charging Infrastructure Trends from the Alternative Fueling Station Locator (Third Quarter 2023)

Electric vehicle (EV) charging infrastructure continues to rapidly change and grow. Using data from the U.S. Department of Energy's (DOE's) Alternative Fueling Station Locator, this report provides a snapshot of the state of EV charging infrastructure in the United States in the third calendar quarter of 2023 (Q3 2023) by charging level, network, and location. Additionally, this report measures the current state of charging infrastructure compared to the infrastructure requirement scenario outlined in the National Renewable Energy Laboratory (NREL) report, The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure. This information is intended to help transportation planners, policymakers, researchers, infrastructure developers, and others understand the rapidly changing landscape of EV charging infrastructure. This is the fifteenth report in a series. Reports from previous quarters can be found in the Alternative Fuels Data Center (AFDC) and NREL publication databases, as well as the AFDC Charging Infrastructure Trends page (https://afdc.energy.gov/fuels/electricity_infrastructure_trends.html).

33 ADVANCED PROPULSION SYSTEMS↗

Cost Evaluation of Alternative Radioisotope Disposal Methods at the Livermore Site

The purpose of this cost evaluation was to investigate a hypothetical in which radioisotopes were no longer permitted in the City of Livermore sanitary sewer. Three alternative methods were proposed to determine estimated costs and compare current practice costs to the latter. An assumption from the initial steps of the analysis was significant cost savings would be found with the alternative methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗