Search NASA⌕ Search

SEARCH · Search NASA

Results for “arraying”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Performance of a gamma-ray tracking array: Characterizing the AGATA array using a 60 Co source

The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4 implementation of the device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Capture of Single Silver Nanoparticles in Nanopore Arrays Detected by Simultaneous Amperometry and Surface-Enhanced Raman Scattering

The attoliter volumes and confinement abilities of zero-dimensional nanopore-electrode arrays (NEAs) hold considerable promise for examining the behavior of single nanoparticles. In this work, we use surface-enhanced Raman scattering (SERS) in tandem with amperometry in order to monitor single Ag Raman-sentinel nanoparticles transported to and captured in single nanopores. To that end, highly ordered solid-state NEAs were fabricated to contain periodic arrays of nanopores, each housing a single recessed Au-ring electrode. These were used to electrostatically capture and trap single silver nanoparticles (AgNPs) functionalized with the electrochemically stable Raman reporter, 1,4-bis(2-methylstyryl)benzene (bis-MSB). Transport and capture of the bis-MSB-tagged AgNPs in the nanopores was followed by simultaneous amperometry and SERS signals characteristic of AgNP oxidation and enhanced Raman scattering by bis-MSB at silver–gold hot spots, respectively. The frequency and magnitude of oxidation-current spikes increased with stepwise increases in DC voltage, and characteristic bis-MSB SERS spectra were observed. Under AC excitation, on the other hand, two distinctly different types of SERS signals were observed, independent of frequency and amplitude: (1) strong, transient (<10 s) spectra and (2) slow (>100 s) monotonically diminishing spectra. We hypothesize that the former behavior results from AgNP aggregates, whereas the latter occurs as a result of multiple incomplete AgNP-oxidation events in succession. Here, these results show that attoliter-volume NEAs are competent for acquiring concurrent SERS spectra and for amperometry of single nanoparticles and that together these measurements can illuminate the collision dynamics of nanoparticles in confined environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tuning Electrogenerated Chemiluminescence Intensity Enhancement Using Hexagonal Lattice Arrays of Gold Nanodisks

Electrogenerated chemiluminescence (ECL) microscopy shows promise as a technique for mapping chemical reactions on single nanoparticles. The technique’s spatial resolution is limited by the quantum yield of the emission and the diffusive nature of the ECL process. To improve signal intensity, ECL dyes have been coupled with plasmonic nanoparticles, which act as nanoantennas. Here, we characterize the optical properties of hexagonal arrays of gold nanodisks and how they impact the enhancement of ECL from the coreaction of tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate and tripropylamine. Here, we find that varying the lattice spacing results in a 23-fold enhancement of ECL intensity because of increased dye-array near-field coupling as modeled using finite element method simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An integrated portable Raman sensor with nanofabricated gold bowtie array substrates for energetics detection

An integrated field-portable surface enhaned Raman scattering (SERS) sensing system has been developed and evaluated for quantitative analysis of energetics such as perchlorate (ClO4-) and trinitrotoluene (TNT) at environmentally-relevant concentrations and conditions. The detection system consists of a portable Raman spectrometer equipped with an optical fiber probe that is coupled with novel elevated gold bowtie nanostructural arrays as a sensitive and reproducible SERS substrate. Using the standard addition technique, we show that ClO4- and TNT can be quantified at concentrations as low as 0.66 mg/L (or ~6.6 M) and 0.20 mg/L (~0.9 M), respectively, in groundwater samples collected from selected military sites. This research represents the first step toward the development of a field SERS sensor which may permit rapid, in-situ screening and analysis for various applications including national security, chemical, biological and environmental detection.

Abu Hatab, Nahla A↗

Vertical Co 9 S 8 hollow nanowall arrays grown on a Celgard separator as a multifunctional polysulfide barrier for high-performance Li–S batteries

Lithium–sulfur (Li–S) batteries have been regarded as one of the most promising next-generation energy-storage devices, due to their low cost and high theoretical energy density (2600 W h kg -1 ). However, the severe dissolution of lithium polysulfides (LiPSs) and the fatal shuttle effect of the sulfur cathode seriously hinder the practical applications of Li–S batteries. To address such issues, we present here, for the first time, a novel metal organic framework (MOF)-derived Co 9 S 8 nanowall array with vertical hollow nanoarchitecture and high electrical conductivity, which is grown in situ on a Celgard separator (Co 9 S 8 –Celgard) via a feasible and scalable liquid-reaction approach, as an efficient barrier for LiPSs in Li–S batteries. Benefiting from the direct in situ growth of vertical Co 9 S 8 hollow nanowall arrays as a multifunctional polar barrier, the Co 9 S 8 –Celgard separator possesses large surface area, excellent mechanical stability, and particularly strong LiPS-trapping ability via chemical and physical interactions. With these advantages, even with a pure sulfur cathode with a high sulfur loading of 5.6 mg cm -2 , the Li–S cells with the Co 9 S 8 –Celgard separator exhibit outstanding electrochemical performance: the initial specific capacity is as high as 1385 mA h g -1 with a retention of 1190 mA h g -1 after 200 cycles. The cells deliver a high capacity of 530 mA h g -1 at a 1C rate (1675 mA g -1 ) even after an impressive number of 1000 cycles with an average capacity fade of only 0.039% per cycle, which is promising for long-term cycling application at high charge/discharge current densities, and pouch-type Li–S cells with the Co 9 S 8 –Celgard separator display excellent cycling performance. When the optimized cathode with the sulfur loading in well-designed yolk–shelled carbon@Fe 3 O 4 (YSC@Fe 3 O 4 ) nanoboxes is employed, the cell with Co 9 S 8 –Celgard delivers a high initial capacity of 986 mA h g -1 at a 1C rate with a capacity retention as high as 83.2% even after a remarkable number of 1500 cycles. In conclusion, this work presents a strategy to grow on the separator a multifunctional polar interlayer with unique nanoarchitecture and high conductivity to chemically and physically trap the LiPSs, thus significantly enhancing the performance of Li–S batteries.

25 ENERGY STORAGE↗

Comparison of polystyrene scintillator fiber array and monolithic polystyrene for neutron imaging and radiography

The neutron imaging diagnostic at the National Ignition Facility has been operating since 2011 generating neutron images of deuterium-tritium (DT) implosions at peak compression. The current design features a scintillating fiber array, which allows for high imaging resolution to discern small-scale structure within the implosion. In recent years, it has become clear that additional neutron imaging systems need to be constructed in order to provide 3D reconstructions of the DT source and these additional views need to be on a shorter line of sight. As a result, there has been increased effort to identify new image collection techniques that improve upon imaging resolution for these next generation neutron imaging systems, such as monolithic deuterated scintillators. This work details measurements performed at the Weapons Neutron Research Facility at Los Alamos National Laboratory that compares the radiographic abilities of the fiber scintillator with a monolithic scintillator, which may be featured in a future short line of sight neutron imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Superlattice-Like Stacking Fault Array in Ion-Irradiated GaN

Controlling defects in crystalline solids is of technological importance for realizing desirable material properties. Irradiation with energetic particles is useful for designing the spatial distribution and concentration of defects in materials. Here, we performed ion irradiation into hexagonal GaN with the wurtzite structure and demonstrated the spontaneous formation of superlattice-like stacking fault arrays. It was found that the modulation period can be controlled by varying the irradiation conditions and subsequent thermal treatments.

Environmental Molecular Sciences Laboratory↗

A VIRTUAL SKY WITH EXTRAGALACTIC H I AND CO LINES FOR THE SQUARE KILOMETRE ARRAY AND THE ATACAMA LARGE MILLIMETER/SUBMILLIMETER ARRAY

We present a sky simulation of the atomic H I-emission line and the first 10 {sup 12}C{sup 16}O rotational emission lines of molecular gas in galaxies beyond the Milky Way. The simulated sky field has a comoving diameter of 500 h {sup -1} Mpc; hence, the actual field of view depends on the (user-defined) maximal redshift z {sub max}; e.g., for z {sub max} = 10, the field of view yields approx4 x 4 deg{sup 2}. For all galaxies, we estimate the line fluxes, line profiles, and angular sizes of the H I and CO-emission lines. The galaxy sample is complete for galaxies with cold hydrogen masses above 10{sup 8} M {sub sun}. This sky simulation builds on a semi-analytic model of the cosmic evolution of galaxies in a LAMBDA cold dark matter (LAMBDACDM) cosmology. The evolving CDM distribution was adopted from the Millennium Simulation, an N-body CDM simulation in a cubic box with a side length of 500 h {sup -1} Mpc. This side length limits the coherence scale of our sky simulation: it is long enough to allow the extraction of the baryon acoustic oscillations in the galaxy power spectrum, yet the position and amplitude of the first acoustic peak will be imperfectly defined. This sky simulation is a tangible aid to the design and operation of future telescopes, such as the Square Kilometre Array, Large Millimeter Telescope, and Atacama Large Millimeter/Submillimeter Array. The results presented in this paper have been restricted to a graphical representation of the simulated sky and fundamental dN/dz analyses for peak flux density limited and total flux limited surveys of H I and CO. A key prediction is that H I will be harder to detect at redshifts z approx> 2 than predicted by a no-evolution model. The future verification or falsification of this prediction will allow us to qualify the semi-analytic models.

79 ASTRONOMY AND ASTROPHYSICS↗

DISTANCE AND KINEMATICS OF THE RED HYPERGIANT VY CMa: VERY LONG BASELINE ARRAY AND VERY LARGE ARRAY ASTROMETRY

We report astrometric results of phase-referencing very long baseline interferometry observations of 43 GHz SiO maser emission toward the red hypergiant VY Canis Majoris (VY CMa) using the Very Long Baseline Array (VLBA). We measured a trigonometric parallax of 0.83 {+-} 0.08 mas, corresponding to a distance of 1.20{sup +0.13}{sub -0.10} kpc. Compared to previous studies, the spatial distribution of SiO masers has changed dramatically, while its total extent remains similar. The internal motions of the maser spots are up to 1.4 mas yr{sup -1}, corresponding to 8 km s{sup -1}, and show a tendency for expansion. After modeling the expansion of maser spots, we derived an absolute proper motion for the central star of {mu}{sub x} = -2.8 {+-} 0.2 and {mu}{sub y} = 2.6 {+-} 0.2 mas yr{sup -1} eastward and northward, respectively. Based on the maser distribution from the VLBA observations, and the relative position between the radio photosphere and the SiO maser emission at 43 GHz from the complementary Very Large Array observations, we estimate the absolute position of VY CMa at mean epoch 2006.53 to be {alpha}{sub J2000} = 07{sup h}22{sup m}58.{sup s}3259 {+-} 0.{sup s}0007, {delta}{sub J2000} = -25 Degree-Sign 46'03.''063 {+-} 0.''010. The position and proper motion of VY CMa from the VLBA observations differ significantly with values measured by the Hipparcos satellite. These discrepancies are most likely associated with inhomogeneities and dust scattering the optical light in the circumstellar envelope. The absolute proper motion measured with VLBA suggests that VY CMa may be drifting out of the giant molecular cloud to the east of it.

79 ASTRONOMY AND ASTROPHYSICS↗

Submillimeter array and very large array observations in the hypercompact H II region G35.58-0.03

The formation of hypercompact (HC) H II regions is an important stage in massive star formation. Spectral line and continuum observations can explore its dynamic conditions. We present high angular resolution observations carried out with the Submillimeter Array (SMA) and the Very Large Array (VLA) toward the HC H II region G35.58-0.03. With the 1.3 mm SMA and 1.3 cm VLA, we detected a total of about 25 transitions of 8 different species and their isotopologues (CO, CH{sub 3}CN, SO{sub 2}, CH{sub 3}CCH, OCS, CS, H, and NH{sub 3}). G35.58-0.03 consists of an HC H II core with electron temperature T{sub e}{sup ∗}≧5500 K, emission measure EM ≈1.9 × 10{sup 9} pc cm{sup –6}, local volume electron density n{sub e} = 3.3 × 10{sup 5} cm{sup –3}, and a same width of radio recombination line FWHM ≈ 43.2 km s{sup –1} for both H30α and H38β at its intrinsic core size ∼3714 AU. The H30α line shows evidence of an ionized outflow driving a molecular outflow. Based on the derived Lyman continuum flux, there should be an early-type star equivalent to O6.5 located inside the H II region. From the continuum spectral energy distribution from 3.6 cm, 2.0 cm, 1.3 cm, 1.3 mm and 0.85 mm to 0.45 mm, we distinguished the free-free emission (25% ∼ 55%) from the warm dust component (75% ∼ 45%) at 1.3 mm. The molecular envelope shows evidence of infall and outflow with an infall rate of 0.05 M {sub ☉} yr{sup –1} and a mass loss rate of 5.2 × 10{sup –3} M {sub ☉} yr{sup –1}. The derived momentum (∼0.05 M {sub ☉} km s{sup –1}) is consistent between the infalling and outflowing gas per year. It is suggested that the infall is predominant and the envelope mass of dense core is increasing rapidly, but the accretion in the inner part might already be halted.

79 ASTRONOMY AND ASTROPHYSICS↗

Searches for large-scale anisotropy in the arrival directions of cosmic rays detected above energy of 10{sup 19} eV at the Pierre Auger observatory and the telescope array

Spherical harmonic moments are well-suited for capturing anisotropy at any scale in the flux of cosmic rays. An unambiguous measurement of the full set of spherical harmonic coefficients requires full-sky coverage. This can be achieved by combining data from observatories located in both the northern and southern hemispheres. To this end, a joint analysis using data recorded at the Telescope Array and the Pierre Auger Observatory above 10{sup 19} eV is presented in this work. The resulting multipolar expansion of the flux of cosmic rays allows us to perform a series of anisotropy searches, and in particular to report on the angular power spectrum of cosmic rays above 10{sup 19} eV. No significant deviation from isotropic expectations is found throughout the analyses performed. Upper limits on the amplitudes of the dipole and quadrupole moments are derived as a function of the direction in the sky, varying between 7% and 13% for the dipole and between 7% and 10% for a symmetric quadrupole.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for correlations between the arrival directions of IceCube neutrino events and ultrahigh-energy cosmic rays detected by the Pierre Auger Observatory and the Telescope Array

This study presents the results of different searches for correlations between very high-energy neutrino candidates detected by IceCube and the highest-energy cosmic rays measured by the Pierre Auger Observatory and the Telescope Array. We first consider samples of cascade neutrino events and of high-energy neutrino-induced muon tracks, which provided evidence for a neutrino flux of astrophysical origin, and study their cross-correlation with the ultrahigh-energy cosmic ray (UHECR) samples as a function of angular separation. We also study their possible directional correlations using a likelihood method stacking the neutrino arrival directions and adopting different assumptions on the size of the UHECR magnetic deflections. Finally, we perform another likelihood analysis stacking the UHECR directions and using a sample of through-going muon tracks optimized for neutrino point-source searches with sub-degree angular resolution. No indications of correlations at discovery level are obtained for any of the searches performed. The smallest of the p-values comes from the search for correlation between UHECRs with IceCube high-energy cascades, a result that should continue to be monitored.

79 ASTRONOMY AND ASTROPHYSICS↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗