Search NASA⌕ Search

SEARCH · Search NASA

Results for “astronomical detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Expected scientific performance of the three spectrometers on the extreme ultraviolet explorer

The expected in-orbit performance of the three spectrometers included on the Extreme Ultraviolet Explorer astronomical satellite is presented. Recent calibrations of the gratings, mirrors and detectors using monochromatic and continuum EUV light sources allow the calculation of the spectral resolution and throughput of the instrument. An effective area range of 0.2 to 2.8 sq cm is achieved over the wavelength range 70-600 A with a peak spectral resolution (FWHM) of 360 assuming a spacecraft pointing knowledge of 10 arc seconds (FWHM). For a 40,000 sec observation, the average 3 sigma sensitivity to a monochromatic line source is 0.003 photons/sq cm s. Simulated observations of known classes of EUV sources, such as hot white dwarfs, and cataclysmic variables are also presented.

Vallerga, J. V.↗

The future of large format HgCdTe arrays for astronomy

Rockwell has developed the 256 x 256 Near Infrared Camera and Multi-Object Spectrometer 3 (NICMOS3) FPA for the Hubble Space Telescope under funding from NASA through the University of Arizona. Since 1989, dozens of science grade devices have been delivered to astronomers throughout the world for ground based infrared observations. These devices have excellent sensitivity at 77 K with mean dark currents of 0.1 e(-)/s, noise of 25 e(-), and quantum efficiency of 55-70%. Pixel yields as high as 99.9% have been achieved. Our present plans are to develop a 1024 x 1024 focal plane array (FPA) with 2.5 micron cutoff and make it available to astronomers. Such large arrays are made possible by the advances in detector material size (3 in. diameter producible alternative to CdTe for epitaxy (PACE-I) wafers), multiplexer advances (ability to verify the design in detail and availability of advanced foundries), and novel hybridization and reliability approaches.

Vural, K.↗

Laboratory Astrophysics White Paper

Laboratory astrophysics and complementary theoretical calculations are the foundations of astronomical and planetary research and will remain so for many generations to come. From the level of scientific conception to that of the scientific return, it is our understanding of the underlying processes that allows us to address fundamental questions regarding the origins and evolution of galaxies, stars, planetary systems, and life in the cosmos. In this regard, laboratory astrophysics is much like detector and instrument development at NASA and NSF; these efforts are necessary for the astronomical research being funded by the agencies. The NASA Laboratory Astrophysics Workshop met at the University of Nevada, Las Vegas (UNLV) from 14-16 February, 2006 to identify the current laboratory data needed to support existing and future NASA missions and programs in the Astrophysics Division of the Science Mission Directorate (SMD). Here we refer to both laboratory and theoretical work as laboratory astrophysics unless a distinction is necessary. The format for the Workshop involved invited talks by users of laboratory data, shorter contributed talks and poster presentations by both users and providers that highlighted exciting developments in laboratory astrophysics, and breakout sessions where users and providers discussed each others' needs and limitations. We also note that the members of the Scientific Organizing Committee are users as well as providers of laboratory data. As in previous workshops, the focus was on atomic, molecular, and solid state physics.

Brickhouse, Nancy↗

Four-year Cosmology Large Angular Scale Surveyor (CLASS) Observations: On-sky Receiver Performance at 40, 90, 150, and 220 GHz Frequency Bands

The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1° ≲ θ ≤ 90° with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been operational at the CLASS site in the Atacama desert since 2016 June, 2018 May, and 2019 September, respectively. We show that the noise-equivalent power measured by the detectors matches the expected noise model based on on-sky optical loading and lab-measured detector parameters. Using Moon, Venus, and Jupiter observations, we obtain power to antenna temperature calibrations and optical efficiencies for the telescopes. From the CMB survey data, we compute instantaneous array noise-equivalent-temperature sensitivities of 22, 19, 23, and 71 $\mu {{\rm{K}}}_{\mathrm{cmb}}\sqrt{{\rm{s}}}$ for the 40, 90, 150, and 220 GHz frequency bands, respectively. These noise temperatures refer to white noise amplitudes, which contribute to sky maps at all angular scales. Future papers will assess additional noise sources impacting larger angular scales.

Observational cosmology↗

Infrared charge-injection-device array performance at low background

Low-background tests of a 1 x 32 Si:Bi charge-injection-device (CID) IR detector are carried out to evaluate its feasibility for space-based astronomical observations. Optimum performance is obtained at a temperature of 11 K. The sensitivity is found to compare well with that of discrete extrinsic silicon photoconductors. The measured sensitivity and the apparent absence of anomalous effects make extrinsic silicon CID arrays very promising for astronomical applications.

Mccreight, C. R.↗

Integrated Arrays Of Infrared Detectors

Report presents overview of technology of integrated arrays of infrared detectors. Covers arrays now available and those under development. Gives examples of astronomical images illustrating potential of infrared arrays for scientific investigations.

Goebel, J. H.↗

Digital array scanned interferometers for astronomy

Investigations are reported of digital array scanned interferometers (DASI) with silicon CCD array detectors to define the operational capabilities of a mapping (polarimetric) spectrometer for astronomical applications based on these instruments. For spectral mapping, spatially resolved spectra using a cylindrical lens to image in the interferometers's redundant coordinate are given. The signal-to-noise characteristics of the Fourier transformed data are demonstrated with regard to the effects of a rectangular sampling function, spectral multiplexing and the pixel-to-pixel variation of the CCD array. These data indicate that DASIs can offer simple, versatile (polarization) mapping spectrometers suitable for spectral mapping observations from the ultraviolet to the infrared of extended sources at variable spatial resolution, particularly where long term stable operation is essential, as for spacecraft instruments.

Smith, Wm. Hayden↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

Independent Testing of JWST Detector Prototypes

The Independent Detector Testing Laboratory (IDTL) is jointly operated by the Space Telescope Science Institute (STScI) and the Johns Hopkins University (JHU), and is assisting the James Webb Space Telescope (JWST) mission in choosing and operating the best near-infrared detectors. The JWST is the centerpiece of the NASA Office of Space Science theme, the Astronomical Search for Origins, and the highest priority astronomy project for the next decade, according to the National Academy of Science. JWST will need to have the sensitivity to see the first light in the Universe to determine how galaxies formed in the web of dark matter that existed when the Universe was in its infancy (z is approximately 10-20). To achieve this goal, the JWST Project must pursue an aggressive technology program and advance infrared detectors to performance levels beyond what is now possible. As part of this program, NASA has selected the IDTL to verify comparative performance between prototype JWST detectors developed by Rockwell Scientific (HgCdTe) and Raytheon (InSb). The IDTL is charged with obtaining an independent assessment of the ability of these two competing technologies to achieve the demanding specifications of the JWST program within the 0.6-5 micron bandpass and in an ultra-low background (less than 0.01 e(-)/s/pixel) environment. We describe results from the JWST Detector Characterization Project that is being performed in the LDTL. In this project, we are measuring first-order detector parameters, i.e. dark current, read noise, QE, intra-pixel sensitivity, linearity, as functions of temperature, well size, and operational mode.

Figer, Donald F.↗

Development of doped-germanium photoconductors for astronomical observations at wavelengths from 30 to 120 micrometers

Technology was developed for production of doped-germanium detectors which have optimized performance in the 30- to 120-micrometer wavelength range and are capable of achieving the objectives of the Infrared Astronomy Satellite space mission. The work of this phase was divided into the following major tasks: (1) growth of Ge:Ga crystals from high-purity starting material with Ga concentrations different from that previously produced, and development of a zone leveling method to produce a uniform Ga doping concentration; (2) growth of uncompensated Ge:Be crystals from high-purity starting material with a range of Be concentrations between 10 to the 14th power and 10 to the 16th power atoms/cubic cm; (3) evaluation of crystals by means of Hall effect and resistance measurements as a function of temperature; (4) fabrication and test of detectors made from both Ge:Be and Ge:Ga crystals to determine the relative performance between different crystals. Correlation of detector test data with material evaluation data and analysis of how to further optimize detector performance.

Bratt, P. R.↗

New measurement of the Fano factor of mercuric iodide

It is pointed out that mercuric iodide (HgI2) shows great promise as a high-resolution X-ray detector for use in X-ray astronomy. Development of mercuric iodide for astronomical work has required investigation of the temperature dependence of the HgI2 crystal parameters such as leakage current, resolution, and mobility of the charge carriers. The first studies in connection with these investigations have led to a new value of the Fano factor of 0.19 + or - 0.03. The best value previously reported was 0.27 measured at room temperature. The new upper limit of 0.19 for the HgI2 Fano factor was determined by cooling the HgI2 crystal and preamp to -20 C. It is concluded that room-temperature energy resolution of HgI2 is not limited by charge generation statistics but rather by collection efficiency.

Ricker, G. R.↗

Germanium blocked-impurity-band detector arrays - Unpassivated devices with bulk substrates

We have fabricated and characterized six-element monolithic arrays of Ge:Ga blocked-impurity-band detectors, with threshold wavelength 220 microns, peak quantum efficiency 14 percent, detective quantum efficiency 9 percent, dark current 300 e(-)/s, and response uniformity better than 4 percent. The devices are described very well by the standard model of blocked-impurity-band detectors and appear to satisfy many of the requirements of low-background astronomical instruments.

Watson, Dan M.↗

X-ray Polarimetry with an Active-Matrix Pixel Proportional Counter

We report the first results from an X-ray polarimeter with a micropattern gas proportional counter using an amorphous silicon active matrix readout. With 100% polarized X-rays at 4.5 keV, we obtain a modulation factor of 0.33+/- 0.03, confirming previous reports of the high polarization sensitivity of a finely segmented pixel proportional counter. The detector described here has a geometry suitable for the focal plane of an astronomical X-ray telescope. Amorphous silicon readout technology will enable additional extensions and improvements.

Black, J. K.↗

Characterization of skipper CCDs for cosmological applications

We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise &sigma; 0.18 e - rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photodiodes for Astronomical Stellar Radiometry

The theory of photodiodes and their application to radiometric measurements is reviewed. Some suggestions concerning photodiode detectors for use in stellar radiometric measurements are given. Quantum efficiency, linear response characteristics, and noise current values of silicon photodiodes are considered.

Schaefer, A. R.↗

Evaluation of Rockwell HgCdTe arrays for astronomical use

The 32 x 32 HgCdTe array manufactured by Rockwell International was proven to be a highly competitive detector type for use at wavelengths shorter than 2.5 microns. The goal of a K=+16 sky survey using this array attached to the Steward Observatory Transit Telescope is clearly within reach. The detector material exhibits high quantum efficiency and low dark currents indicating that its usefulness may extend beyond its use with a CCD readout on groundbased telescopes.

Lebofsky, M. J.↗

X-Ray Detector Research at MSFC for Space Applications

NASA's Vision for Space Exploration has specific goals aimed at exploring the Solar System. This vision, under presidential mandate includes landing humans on the moon before the end of the next decade, paving the way for eventual journeys to Mars and beyond. The first missions to the moon will be in the form of both Orbiters and Landers, with the goal of paving the way for human return. One of the instruments we are currently working on,in collaboration with Brookhaven National Laboratory, is a lunar orbiter fluorescent x-ray spectrometer to finely map the light elements (down to Carbon) on surface of the moon. Funded NASA s Planetary Instrument Definition and Development Program the instrument is based on silicon drift detector arrays read out by custom ASICs. These offer the promise of high spectral resolution, necessary for resolving weak lines against a strong background continuum, and very low power requirements, necessary for large areas (greater than 500 square centimeters) required for future lunar missions. Further, the inherent radiation hardness of these detectors makes them ideal candidates for exploring the Jovian system, where the harsh radiation environment from Jupiter s radiation belts creates unfavorable detector conditions. Looking beyond our solar system, in the hard x-ray regime (20-80keV.), we are studying Cadmium-Zinc-Telluride pixilated detectors as feasible candidates for focal plane detectors of a hard x-ray telescope. This energy region bridges the gap between thermal and non-thermal x-ray emission from astronomical sources, will allow us to better understand supernovae nucleosynthesis (such as through the Ti-44 lines at 68keV and 78keV), Active Galactic Nuclei and other compact objects, more completely. The detectors that we are characterizing are 2mm in thickness and are pixilated with a 16x16 array of 300 micrometer pitch pixels (50micometer gap). These detectors are designed at Rutherford Appleton Laboratory, material is from eV Products, and polymer flip-chip assembly was performed by a commercial vendor. An energy resolution of 2.0% at 60keV (or better) should allow us to sufficiently distinguish lines of interest from background continuum, and the detector spatial resolution should be fine enough to over-sample the focal spot from the x-ray focusing optics by about a factor of two. Full technical details of these developments will be presented.

Gaskin, Jessica↗