Search NASA⌕ Search

SEARCH · Search NASA

Results for “atomic frequency standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phase modulation for reduced vibration sensitivity in laser-cooled clocks in space

The standard interrogation technique in atomic beam clocks is square-wave frequency modulation (SWFM), which suffers a first order sensitivity to vibrations as changes in the transit time of the atoms translates to perceived frequency errors. Square-wave phase modulation (SWPM) interrogation eliminates sensitivity to this noise.

frequency standard frequency modulation phase modu↗

Frequency shifts in a rubidium frequency standard due to coupling to another standard

Highly reliable timing system, such as used on board satellites, may incorporate a hot standby atomic clock besides the active one. RF couplings between them may affect the performance of the active clock. The effect of such couplings between two rubidium atomic clocks was investigated, and it was found that they will add an oscillatory term to the Allan Variance of the active clock, degrading its frequency stability, and that under certain circumstances they may also shift the active clock's operating frequency. These two effects are discussed in detail, and the level of isolation required to render them negligible is established.

Jaduszliwer, Bernardo↗

Light shift measurements in a Cesium Fountain without the use of mechanical shutters

We present measurements confirming operation of a cesium fountain frequency standard with light shift below 10^-15 (and with evidence suggesting it is several orders of magnitude below this level) but without the use of mechanical shutters. Suppression of the light shift is realized using a master-slave laser configuration by reducing the overall optical power delivered to the physics package as well as spoiling the injection of the slave, causing it to lase far off resonance (1-2 nm) as proposed by the authors several years ago [l]. In the absence of any mitigation, this (AC Stark) shift, due to near-resonant laser light reaching the atoms during their microwave interrogation period, is the largest shift in such frequency standards (2x10^-11 for Our fountain). Mechanical shutters provided adequate light attenuation but have been prone to failure.

light shift measurements↗

Frequency standards from industry over the next 25 years

Present and possible future performance for many of the existing and new commercial frequency standards is presented here. Recent progress in the gas cell atomic standards with regards to size and cost is significant and considerable improvement is expected. Cesium beam standards will benefit in stability and accuracy from optical pumping. Cooled hydrogen masers will offer extremely good stability. Advances in trapped ion and cesium fountain technologies make them good high performance candidates for the future. The quartz oscillator field is more mature and consequently performance improvements for the future are going to be less spectacular. Oscillators stabilized to GPS will have many applications. Recent performance of cooled microwave dielectric resonator oscillators is very good and they offer the promise of serving as flywheel oscillators for advanced performance atomic standards.

Cutler, Leonard S.↗

Frequency standard stability for Doppler measurements on-board the shuttle

The short and long term stability characteristics of crystal and atomic standards are described. Emphasis is placed on crystal oscillators because of the selection which was made for the shuttle baseline and the complexities which are introduced by the shuttle environment. Attention is given, first, to the definitions of stability and the application of these definitions to the shuttle system and its mission. Data from time domain measurements are used to illustrate the definitions. Results of a literature survey to determine environmental effects on frequency reference sources are then presented. Finally, methods of standard frequency dissemination over radio frequency carriers are noted as a possible means of measuring absolute accuracy and long term stability characteristics during on one way Doppler equipment.

Harton, P. L.↗

Next Generation JPL Ultra-Stable Trapped Ion Atomic Clocks

Over the past decade, trapped ion atomic clock development at the Jet Propulsion Laboratory (JPL) has focused on two directions: 1) new atomic clock technology for space flight applications that require strict adherence to size, weight, and power requirements, and 2) ultra-stable atomic clocks, usually for terrestrial applications emphasizing ultimate performance. In this paper we present a new ultra-stable trapped ion clock designed, built, and tested in the second category. The first new standard, L10, will be delivered to the Naval Research Laboratory for use in characterizing DoD space clocks.

Naval Research Laboratory (NRL)↗

Higher Pole Linear Traps for Atomic Clock Applications

We investigate experimentally and theoretically higher pole linear ion traps for frequency standard use. We have built a 12-pole trap and have successfully loaded ions into it from a linear quadrupole trap. By solving the Boltzmann equation describing large ion clouds where space charge interactions are important, we show that clock frequency changes due to ion number fluctuations are much smaller in ion clocks based multipole traps than comparable clocks based on quadrupole linear traps.

Prestage, John D.↗

Photon-recoil and laser-focusing limits to Rydberg gate fidelity

Limits to Rydberg gate fidelity that arise from the entanglement of internal states of neutral atoms with the motional degrees of freedom due to the momentum kick from photon absorption and re-emission is quantified. This occurs when the atom is in a superposition of internal states but only one of these states is manipulated by visible or UV photons. The Schrödinger equation that describes this situation is presented and two cases are explored. In the first case, the entanglement arises because the spatial wave function shifts due to the separation in time between excitation and stimulated emission. For neutral atoms in a harmonic trap, the decoherence can be expressed within a sudden approximation when the duration of the laser pulses are shorter than the harmonic oscillator period. In this limit, the decoherence is given by simple analytic formulas that account for the momentum of the photon, the temperature of the atoms, the harmonic oscillator frequency, and atomic mass. In the second case, there is a reduction in gate fidelity because the photons causing absorption and stimulated emission are in focused beam modes. This leads to a dependence of the optically induced changes in the internal states on the center of mass atomic position. In the limit where the time between pulses is short, the decoherence can be expressed as a simple analytic formula involving the laser waist, temperature of the atoms, the trap frequency, and the atomic mass. These limits on gate fidelity are studied for the standard π-2π-π Rydberg gate and a protocol based on a single adiabatic pulse with a Gaussian envelope.

74 ATOMIC AND MOLECULAR PHYSICS↗

A marching method for calculating line and continuum radiation in high energy flow fields

A method is presented for calculating nongrey radiative fluxes and intensities in a highly ionized, low temperature plasma with extreme line broadening. The method was developed to study radiative heating phenomena in the mass-injected hypersonic shock-layer environments characteristic of outer planet atmospheric entry, although it is not limited to such studies. The radiative properties model assumed local thermodynamic equilibrium and used standard continuum and molecular band models. The atomic line model, however, used a frequency-marching method for the frequency integration, which not only accounted completely for line overlapping (reabsorption) effects, but compared favorably in economy with the best equivalent-width methods. An assessment of hydrogen line-far-wing treatments, with recommendations for engineering models, is also presented.

Bolz, C. W., Jr.↗

Flexible bulb large storage box hydrogen maser

The principal limitation on the accuracy of the hydrogen maser as a primary frequency standard has been the irreproducibility of the frequency shift caused by collisions of the radiating atoms with the walls of the vessel containing them. The flexible bulb-large storage box hydrogen maser allows correction for this wall shift within a single device, sidestepping the reproducibility problem, and reducing the frequency error from the wall shift to the level imposed by the device's stability. The principles of the device are discussed including the flexible bulb technique and the complications caused by a multiple region storage bulb. The stability of the device is discussed including a comparison with an ordinary hydrogen maser. Data is presented from a working flexible bulb-large storage box hydrogen maser demonstrating the feasibility of the device and showing some of its operating characteristics. The flexibility of the device is demonstrated by showing how the device's added degrees of freedom allow measurement of parameters unmeasurable in an ordinary hydrogen maser.

Reinhardt, V.↗

Characteristics of advanced hydrogen maser frequency standards

In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.

Peters, H. E.↗

An improved linear ion trap physics package

This article describes an improvement in the architecture of the physics package used in the Linear Ion Trap (LIT)-based frequency standard recently developed at JPL. This new design is based on the observation that ions can be moved along the axis of an LIT by applied dc voltages. The state selection and interrogation region can be separated from the more critical microwave resonance region where the multiplied local oscillator signal is compared with the stable atomic transition. This separation relaxes many of the design constraints of the present units. Improvements include increased frequency stability and a substantial reduction in size, mass, and cost of the final frequency standard.

Prestage, J. D.↗

Recent progress in the NASA-Goddard Space Flight Center atomic hydrogen standards program

At NASA Goddard Space Flight Center and through associated contractors, a broad spectrum of work is being carried out to develop improved hydrogen maser frequency standards for field use, improved experimental hydrogen maser frequency standards, and improved frequency and time distribution and measurement systems for hydrogen maser use. Recent progress in the following areas is reported: results on the Nr masers built by the Applied Physics Laboratory of Johns Hopkins University, the development of a low cost hydrogen maser at Goddard Space Flight Center, and work on a low noise phase comparison system and digitally phase locked crystal oscillator called the distribution and measurement system.

Reinhardt, V. S.↗

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗